• Title/Summary/Keyword: 열/물질전달

Search Result 352, Processing Time 0.029 seconds

Numerical Study on Simultaneous Heat and Mass Transfer in a Falling Film of Water-Cooled Vertical Plate Absorber (수냉식 수직평판 흡수기의 액막 열 및 물질전달에 관한 수치적 연구)

  • Thanh-Tong Phan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.593-602
    • /
    • 2004
  • This paper is a study on the model of simultaneous heat and mass transfer process in the absorption of refrigerant vapor into a lithium bromide solution of water-cooled vertical plate absorber. The model can predict temperature and concentration profiles as well as the effect of Reynolds number on them. Also. the variations of the absorption heat and mass fluxes. and the heat and mass transfer coefficients have been investigated. The numerical result shows that the interface temperature and concentration decrease as film Reynolds number does. The absorption heat and mass fluxes, and the heat and mass transfer coefficients get their maximum values adjacent to the inlet solution. Analyses on a constant wall temperature condition have been also carried out to exam the reliability of the present numerical method by comparing to previous investigations.

Heat/mass transfer characteristics of arrays of impingement jets using effusion holes (유출홀을 사용한 배열충돌제트의 열/물질전달 특성)

  • Yoon, P.H.;Hwang, S.D.;Cho, H.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.125-131
    • /
    • 2000
  • The local heat/mass transfer coefficients for arrays of impinging circular air jets on a plane surface are determined by means of the naphthalene sublimation method. Spent fluid makes a crossflow in the confined space. The crossflow reduces heat/mass transfer at the small gap distance between the jet plate and impingement surface because of reentrainment of the spent fluid. The present study suggests a new exhaust system having effusion holes in the impinging jet plate. The spent air flow out after impingement just through effusion holes located in the upper plate. This system increases heat/mass transfer coefficients and uniformity for small gap distances$(H/d{\leq}2)$

  • PDF

HEAT/MASS TRANSFER CHARACTERISTICS IN ROTATING TWO-PASS SQUARE CHANNELS WITH $90^{\circ}$RIBS ($90^{\circ}$요철이 설치된 회전하는 정사각 이차 유로에서의 열/물질전달 특성)

  • Kim, Kyung-Min;Kim, Sang-In;Kim, Yun-Young;Rhee, Dong-Ho;Cho, Hyung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.436-441
    • /
    • 2003
  • The present study investigates heat/mass transfer characteristics in rotating two-pass ducts of three different aspect ratios with 90-ribbed surfaces. The results show that the flows generated by the 180-turn, rib turbulators, and duct rotation. The curvature of the 180-turn produces Dean vortices causing high heat/mass transfer in the turning region and in the upstream region of the second-pass. The rib turbulators disturb the main flow by producing reattachment and separation near the ribbed surfaces, and increase heat/mass transfer in the region between the ribs. As the rotation number increases, the heat/mass transfer discrepancy between the leading and the trailing surfaces become larger.

  • PDF

A Numerical Analysis of cleat and Mass Transfer on the Dehumidifier of Liquid Desiccant Cooling System (액체 건조제 냉각장치의 제습기에서 열 및 물질전달 수치해석)

  • Go, Gwang-Ho;O, Myeong-Do
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1756-1765
    • /
    • 2001
  • The heat and mass transfer process between the falling liquid desiccant(TEG) film and the air in counter flow at the dehumidifier of desiccant cooling system were investigated. The governing equations with appropriate boundary and interfacial conditions describing the physical problems were solved by numerical analysis. As a result, the effects of the design parameters and the outside air conditions on the rates of dehumidification and sensible cooling were discussed. The results of the dehumidification and sensible cooling rates were compared with those of the cross flow at the same conditions.

Heat and Mass Transfer Characteristics and Performance Evaluation of a Double-Tube Condenser for an Alternative Refrigerant (대체냉매의 2중관 응축기 열 및 물질전달과 성능평가)

  • 이상무;박병덕;소산번
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.468-476
    • /
    • 2002
  • This paper deals with heat and mass transfer characteristics and performance evaluation of a counter flow double-tube condenser for a multi-component refrigerant mixture. The local heat and mass transfer characteristics of ternary zeotropic refrigerant mixtures composed of HFC32/HFC125/HFC134a are evaluated for a counter flow double-tube condenser cooled by water. Then, the local values of vapor quality, thermodynamic states at bulk vapor, vapor-liquid interface and bulk liquid, heat flux and condensation mass flux are obtained. The heat exchange performance for ternary zeotropic refrigerant mixtures composed of HFC32/HFC125/HFC134a on the total pressure drop and the heat transfer characteristics are also compared with those for R404A, R410A, R502, R22, R32, Rl23 and R134a.

Heat and Mass Transfer between Hot Waste Gas and Cold Water in a Direct Contact Heat Exchanger (직접접촉식 열교환기내에서 물과 배기가스의 직접접촉에 의한 열 및 물질전달)

  • 이금배
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.6
    • /
    • pp.1171-1178
    • /
    • 1992
  • An experiment was performed to describe the heat and mass transfer occurring between hot waste gas and cold water through direct contact in a direct contact heat exchanger. This model was then used to obtain an equation of overall heat transfer coefficent based on heat exchanger volume. The diffusion heat transfer rate is 2-3 times larger than the convection heat transfer rate as results of condensation of the water vapor contained in the waste gas. The boiler efficiency increases over 10%.

Characteristics of Bubble Mode in the Cylindrical Absorber for Heat Pump System (열펌프 시스템에서 원통형 흡수기 내 기포모드의 특성)

  • 이기봉;전병희;이재철;박찬진;김성현
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2000.11a
    • /
    • pp.199-204
    • /
    • 2000
  • 산업과 과학발달에 의해 더욱 물질적으로 풍요로워진 인류에게 에너지와 환경문제는 새로운 당면문제로 부각되고 있다. 특히 1992년 몬트리올 협정에서는 CFC 및 HCFC의 사용을 각각 1997과 2002년부터 전면 금지시키기로 하였고, 1997년에는 2008-2012년까지 전세계 온실가스 배출량을 5.2% 줄이는 것을 골자로 하는 교토 선언이 합의되었다. 이러한 상황을 타개하기 위한 많은 연구 중 흡수식 열펌프는 환경친화적인 자연냉매를 사용하는 열구동 시스템으로 다시 주목을 받고 있다. 특히 흡수식 열펌프의 구성요소 중 흡수에 의하여 고온의 열을 얻을 수 있는 흡수기에 효율적인 열·물질전달 모드를 적용함으로써 제품의 소형화와 에너지 손실 감소를 이루고 있다. 이에 본 연구에서는 새로운 흡수기 모드로 연구되고 있는 기포타입모드를 원통형 흡수기에 적용해 보고, 그 특성을 고찰해 보고자 하였다. 흡수기로 유입되는 ammonia gas와 용액을 cocurrnet 및 countercurrent로 흘려주었고, 높이에 따른 농도, 온도 및 압력을 측정·비교해 보았다.(중략)

  • PDF

A Numerical Study on Heat and Mass Transfer in a Falling Film of Vertical Plate Absorber Cooled by Air (공랭형 수직평판 흡수기 액막에서의 열 및 물질전달에 관한 수치적 연구)

  • 김선창;오명도;이재헌
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.4
    • /
    • pp.1071-1082
    • /
    • 1995
  • Numerical analyses have been performed to obtain the absorption heat and mass transfer coefficients and the absorption mass flux from a falling film of the LiBr aqueous solution which is cooled by cooling air. Heat flux at the wall is specified in terms of the heat transfer coefficient of cooling air and the cooling air temperature. Effects of operating conditions, such as the heat transfer coefficient, the cooling air temperature, the system pressure and the solution inlet concentration have been investigated in view of the local absorption mass flux and the total mass transfer rate. Effects of film thickness and film Reynolds number on the heat and mass transfer coefficients have been also estimated. Analyses for the constant wall temperature condition have been also carried out to examine the reliability of present numerical method by comparing with previous investigations.

Experimental Study on Heat and Mass Transfer Characteristics in bundles of horizontal absorption tubes (수평관군 흡수기의 열 및 물질 전달특성에 관한 실험적 연구)

  • 설원실;정용욱;문춘근;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.3
    • /
    • pp.113-120
    • /
    • 2000
  • On the absorber of absorption chiller/heater, LiBr solution at high concentration is sprinkled on a bundle of horizontal tube cooled by cooling water. In this case, the conditions of LiBr solution and cooling water have an influence on heat/mass transfer coefficient in this system. Therefor it is important to find optimal operation conditions of absorption chiller/heater to save energy. Heat and mass transfer coefficient increased with the increase of solution flow rate, and also heat and mass transfer rate increased but overall heat and mass transfer coefficient decreased by increasing the solution concentration within the experimental range. The superheating of the solution resulted in superior heat transfer character to a state of equilibrium from the point of heat flux and overall heat transfer coefficient.

  • PDF