• Title/Summary/Keyword: 열(물질)전달계수

Search Result 43, Processing Time 0.029 seconds

Measurement of Thermal Load in the Tip-Clearance Region of a Rotor Surface (팁간극 영역에서의 동익 표면 열부하 측정)

  • Lee, Sang-Woo;Kwon, Hyun-Goo;Park, Jin-Jae
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.187-192
    • /
    • 2003
  • The heat (mass) transfer characteristics in the tip-leakage flow region of a high-turning first-stage turbine rotor blade has been investigated by employing the naphthalene sublimation technique. The heat transfer data in the tip-leakage flow area for the tip clearance-to-span ratio, h/s, of 2.0% are compared with those in endwall three-dimensional flow region without tip clearance (h/s = 0.0 %). The result shows that the thermal load in the tip-leakage flow region for h/s = 2.0% is more severe than that in the endwall flow region for h/s = 0.0%. The thermal loads even at the leading and trailing edges for h/s = 2.0% are found larger than those for h/s = 0.0%. The tip-leakage flow results in heat transfer augmentations near the tip on both pressure and suction sides in comparison with the mid-span results.

  • PDF

Analysis of density diffusion analysis by Fick's laws in the human body (픽법에 의한 생체 내의 농도 확산 분석)

  • Che, Gyu-Shik
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.4
    • /
    • pp.657-664
    • /
    • 2012
  • One of the methods to transmit solute through solvent is diffusion. Various particles or molecules including several charged ions in the body diffuse from high density region to low density due to density difference or external electric field. This kind of mechanism is due to thermal motion of each solute molecules. These situations can be deployed using Fick's first and second laws that govern diffusion phenomena in the body. I analysis these diffusion status of material in the body using above mentioned Fick's laws and then implement them through illustration.

Two dimensional flow and heat/mass transfer characteristics in rectangular wavy duct with corrugation angle (2차 유동 영역에서 꺽임각 변화에 따른 주름진 사각 덕트에서의 열/물질전달 및 유동 특성)

  • Kwon, Hyun-Goo;Hwang, Sang-Dong;Cho, Hyung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2267-2272
    • /
    • 2007
  • The present study investigates the two dimensional flow and heat/mass transfer characteristics of wavy duct with various corrugation angles. For the heat/mass transfer coefficients, a naphthalene sublimation technique is used. Numerical analysis and wall pressure measurement show detailed two dimensional flow features. The corrugation angles change from 145$^{\circ}$ to 100$^{\circ}$. The operating Reynolds numbers based on the duct hydraulic diameter vary from 700 to 3,000. The duct aspect ratio maintains 7.3. On the pressure wall, strong flow mixing enhances heat/mass transfer coefficients at the front position. In addition, the rear side of pressure wall, the near of peak, is affected by the acceleration and the shedding of main flow. On the suction wall, however, flow separation and reattachment lead to the valley and the peak of heat/mass transfer coefficient. Also, highly increasing boundary layer at the suction wall affects the decrease of heat/masst transfer. As decreasing corrugation angles, the spanwise average Sherwood number increases and the peak or the valley positions of the local Sherwood number are varied.

  • PDF

Studies on the Shape Change of Trilobal Fibers in Melt Spinning

  • Jung, Il;Kim, Sang-Yong
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 1998.10a
    • /
    • pp.260-263
    • /
    • 1998
  • 섬유단면이 원형이 아닌 L, T, H, W, Y, I 등과 같은 모양을 가지는 이형단면 섬유(shaped fiber)는 그 모양으로 인해 원형단면 섬유와는 다른 광택, 마찰계수, 촉감, 굽힘강도 등을 가지고 여러 가지 용도로 쓰이고 있다. 이형단면 섬유의 용융방사시 같은 면적을 가진 원형단면 섬유와 비교해 증가된 표면적은 열과 물질 전달을 증가시키고 고화를 촉진한다. (중략)

  • PDF

A Study on the Laminar Flow Field and Heat Transfer Coefficient Distribution for Supercritical Water in a Tube (초임계상태의 물에 대한 관 내 층류유동장 및 열전달계수 분포특성에 관한 연구)

  • 이상호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.768-778
    • /
    • 2003
  • Numerical analysis has been carried out to investigate laminar convective heat transfer in a tube for supercritical water near the thermodynamic critical point. Fluid flow and heat transfer are strongly coupled due to large variations of thermodynamic and transport properties such as density, specific heat, viscosity, and thermal conductivity near the critical point. Heat transfer characteristics in the developing region of the tube show transition behavior between liquid-like and gas-like phases with a peak in heat transfer coefficient distribution near the pseudocritical point. The peak of the heat transfer coefficient depends on pressure and wall heat flux rather than inlet temperature and Reynolds number, Results of the modeling provide convective heat transfer characteristics including velocity vectors, temperature, and the properties as well as the heat transfer coefficient. The effect of proximity to the critical point is considered and a heat transfer correlation is suggested for the peak of Nusselt number in the tube.

Analysis of heat and mass transfer in a vertical tube absorber cooled by air (공랭형 수직원관 흡수기에서의 열 및 물질전달 해석)

  • Kim, Seon-Chang;O, Myeong-Do;Lee, Jae-Heon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.10
    • /
    • pp.3293-3303
    • /
    • 1996
  • Numerical analyses have been performed to estimate the absorption heat and mass transfer coefficients in absorption process of the LiBr aqueous solution and the total heat and mass transfer rates in a vertical tube absorber which is coolING ed by air. Axisymmetric cylindrical coordinate system was adopted to model the circular tube and the transport equations were solved by the finite volume method. Absorption behaviors of heat and mass transfer were analyzed through falling film of the LiBr aqueous solution contacted by water vapor in tube. Effects of film Reynolds number on heat and mass transfer coefficients have been also investigated. Especially, effects of tube diameter have been considered to observe the total heat and mass transfer rates through falling film along the tube. Based on the analysis it has been found that the total mass transfer rate increases rapidly in a region with low film Reynolds number(10 ~ 40) as the film Reynolds number increases, while decreases beyond that region. The total heat and mass transfer rates increase with increasing the tube diameter.

A New Approach to Obtain Time Series for Dynamic Water Quality Analysis (동적 수질분석을 위한 시계열 자료 획득 방안 제시)

  • Park, Chae-Il;Kim, Joong-Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1012-1016
    • /
    • 2006
  • 최근 오염총량관리제도를 위한 오염부하량의 관리문제가 대두되면서 이를 위한 수질분석의 중요성이 인식되고 있다. 그러나 시간적 변화를 가진 유입유량, 유입부하량 자료의 한계로 인하여 기준유량을 대상으로 하는 정적수질분석의 결과가 환경정책에 반영되고 있는 실정이며, 이는 하천유량의 변동과 강우 시 비점오염부하량을 무시한 지극히 제한된 분석에 국한되어 있다. 따라서 시간적 변화를 가진 동적수질분석의 결과가 정책에 반영되기 위해서는 자료의 확보가 우선이다. 본 연구에서는 월 별, 소유역 별 시계열 자료 확보를 위하여 합리적이고 사용이 용이한 방법을 제시하였다. 유출량의 경우, 기존의 비유량법과는 달리 저류효과를 고려한 토양수분 저류구조 Tank모형을 적용하여 장기간의 유출량을 산정하였고, 유출농도의 경우, 기존 인접유역의 동일 유달계수 적용과는 달리, 월 오염부하총량비와 유역오염부하 전달함수를 이용하여 월 별, 소유역 별, 수질변수 별 유출농도를 산정하였다. 산정된 유출량과 유출농도는 남강댐 상류유역 하천에서 WASP 모형을 가지고 동적수질분석을 하기 위하여 적용되었다. 그 결과 적절한 오염물질 농도곡선을 얻을 수 있었으며, 제안된 가정의 적용 가능성은 충분하였다.

  • PDF

An Experimental Study on Absorber with Spiral Tube in Absorption Heat Pump (흡수열펌프에서 나선형 관이 설치된 흡수기의 실험적 연구)

  • Min, Byong-Hun
    • Applied Chemistry for Engineering
    • /
    • v.21 no.1
    • /
    • pp.71-75
    • /
    • 2010
  • The efficient performance of absorber is of great importance for the absorption heat pump cycle. The experimental study of absorber with spiral tube of tangential feeding of liquid phase has been investigated using methanol-glycerine as a working fluid. The effect of change in absorber operating conditions was analyzed to improve the performance. The increase in solution flow rate and cooling flow rate positively affects the absorber performance while an increse in the solution concentration negatively affects the absorber performance. The results showed that mass absorption flux was in the range of $0.2{\sim}0.6kgm^{-2}sec^{-1}$, the solution heat transfer coefficient between 1.6 and $4.2kwm^{-2}K^{-1}$, the absorber thermal load from 0.9 to 1.5kw and the mass transfer coefficient from 0.9 to 1.7 m/sec.

Study on Effect of Increase in Inlet Temperature on Nafion Membrane Humidifier (입구온도 변화가 중공사형 나피온 막가습기의 성능에 미치는 영향에 대한 연구)

  • Hwang, Jun-Young;Chang, Hyo-Sun;Kang, Kyung-Tae;Kang, Heui-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.4
    • /
    • pp.361-369
    • /
    • 2011
  • The effect of an increase in the temperature of inlet air on the performance of a membrane humidifier for a PEMFC (Polymer Electrolyte Membrane Fuel Cell) vehicle was investigated both experimentally and numerically. A shell-and-tube type gas-to-gas humidifier with Nafion membrane was tested. The experimental result showed that water transfer varies nonlinearly with the temperature elevation. Numerical analysis based on detailed modeling was also conducted in simplified geometry of a single tube to explain this nonlinear behavior. The simulation revealed that the local water flux varies nonlinearly and dramatically along the tube. The analysis was based on the inverse relationship between the increase in temperature and decrease in relative humidity, both of which seriously affect the water conductivity of the membrane.

Experimental and Theoretical Study on Silica Gel Regeneration (실리카 젤의 재생에 관한 실험적 및 이론적 연구)

  • 고학균;정도섭
    • Journal of Biosystems Engineering
    • /
    • v.2 no.2
    • /
    • pp.1-14
    • /
    • 1977
  • 현재 선진국에서 널리 이용되고있는 곡물의 화력건조는 곡물의 품질을 손상시킬 뿐만 아니라 손실을 증가시키고 있다. 화력에 의한 건조는 또한 연료의 절약면에서 볼 때 역시 문제점을 내포하고있다.l 이러한 문제점들을 해결하기 위하여 근래에는 실리카 젤과 같은 흡습성의 건조제를 사용한 곡물의 건조 실험이 진행 중에 있으며 좋은 결과를 보여주고 있다. 실리카겔은 그 자체무게의 40% 까지 동적 및 정적하에서 수분을 흡수하는 성질을 가지고 있으며 일단 포화상태가 되면 수천번 재생이 가능하다. 본 연구에서는 이와같은 실리카텍의 재생실험을 일차적으로 실내에서 공기의 온도를 일정하게 한 상태에서 실시하였으며 일반적으로 실리카 젤은 $300^{\circ}F$에서 완전재생이 가능하나 본 실험에서 사용된 재생온도는 평면식 태양열 집열기로부터 얻을 수 있는 $150^{\circ}F$ 내외에서 시도하였다. 본실험과 병행하여 건조중 공기와 실리카 젤의 에너지 및 질량변화에 따른 이론식을 만들어 주어진 여러 가지 조건에 대하여 4개의 미분방정식을 컴퓨터에 의하여 해결하였으며 건조(재생) 시간에 따른 공기의 온도와 흡습 및 실리카 젤의 함수량을 구하였다. 위의 이론적인 분석결과는 후에 태양열집열기를 이용한 재생실험을 분석하는데 적용될 것이다. 본 연구결과를 요약하면 다음과 같다. 1. 본 연구에서 유도한 이론식은 실리카 젤의 재생온도를 만족스럽게 표시하였으며 재생시간에 따른 공기의 온도와 흡습 및 실리카 젤의 함수량변화의 이론치는 실험치와 근사하였다. 2. 이론치와 실험치를 일치시키기위하여 흡착온도에서 산출된 열 및 질량 전달계수를 1/5로 조정 사용하였다. 3. 실리카 젤은 $120^{\circ}F$에서 9 %, $180^{\circ}F$에서 1% 내외로 재생이 가능하였다. 4. 본 연구에서 유도된 이론적 분석방법은 다른 여러 가지 형태의 물질 및 건조 또는 냉각 과정을 분석하는데 사용될 수 있다.

  • PDF