• Title/Summary/Keyword: 연직방향진동

Search Result 28, Processing Time 0.027 seconds

A Shaking Table Test for Equipment Isolation in the NPP (II): FPS (원전기기의 면진을 위한 진동대 실험 II : FPS)

  • Kim, Min-Kyu;ZChoun, Young-Sun;Choi, In-Kil
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.5 s.39
    • /
    • pp.79-89
    • /
    • 2004
  • This paper presents the results of experimental studies on the equipment isolation effect in the nuclear containment. For this purpose, shaking table tests were performed. The purpose of this study is enhancement of seismic safety of equipment in the Nuclear Power Plant. The isolation system, known as Friction Pendulum System (FPS), combines the concepts of sliding bearings and pendulum motion was selected. Peak ground acceleration, bidirectional motion, effect of vertical motion and frequency contents of selected earthquake motions were considered. As a result, these are founded that the vertical motion of seismic wave affect to the base isolation and the isolation effect decreased in case of near fault earthquake motion.

Comparative Study on k-ε and k-ω Closures under the Condition of Turbulent Oscillatory Boundary Layer Flow at High Reynolds Number (높은 레이놀즈수를 가진 난류 진동 경계층에서의 k-ε과 k-ω 난류모형의 비교)

  • Son, Min-Woo;Lee, Guan-Hong;Lee, Kil-Seong;Lee, Du-Han
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.3
    • /
    • pp.189-198
    • /
    • 2011
  • The aim of this study is to compare k-$\varepsilon$ and k-$\omega$ closures under the condition of oscillatory layer flow at high Reynolds number. A one dimensional vertical model incorporated with flow momentum equations and turbulence models (k-$\varepsilon$ and k-$\omega$) is applied to the laboratory measurements in the turbulent oscillatory boundary layer. The numerical simulation reveals that both turbulence models calculate similar velocity profiles and turbulent kinetic energy (TKE). In addition, both deliver high accuracy under the condition of negligible spanwise pressure gradient. Therefore, it is recommended in this study to use k-$\varepsilon$ closure, of which numerical coefficients have been calibrated from many studies, for the cases of straight channel, estuary, and coastal environment where the spanwise pressure gradient is not significant.

Prediction of Penetration Rate of Sheet Pile Driven by Vibratory Pile Driver (진동타입기에 의한 쉬트파일의 관입속도 예측)

  • Lee Seung-Hyun;Kim Byung-Il;Lee Jong-Ku;Yoon Ki-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.4
    • /
    • pp.679-683
    • /
    • 2006
  • Numerical integration-based program which simulates motion of pile driven by vibratory pile driver was developed for predicting rate of penetration of pile. Rate of penetration of pile calculated from developed program was compared with those of field test. As pile penetration depth increases, the difference between predicted rate of penetration and measured rate of penetration decreases. It was concluded that the reason for large difference between the predicted value and the measured value at shallower depths was attributed to decrease of vertical compressive force caused from relatively larger flexural and torsional motion of sheet pile.

  • PDF

Application of TMD for Seismic Response Control of Dome Structure (돔 구조물의 지진응답 제어를 위한 TMD의 적용)

  • Kim, Gee-Cheol;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.1
    • /
    • pp.99-108
    • /
    • 2012
  • Vibration control devices are classified into passive, semi-active and active device. TMD(Tuned Mass Damper) is one of the passive control device that is mainly used to reduce vibration level of building structure and bridge structure. In this study, the application of passive tuned mass damper(TMD) to seismic response control of dome structures has been investigated. Because star dome structure has primary characteristics of dome structures, star dome structure was used as an example dome structure that is subjected to horizontal or vertical seismic loads. From this numerical analysis, it is shown that seismic response are influenced by vibration modes and it is reasonable to install TMD to the dominant points of each mode. And it is found that the passive TMD could effectively reduce the seismic responses of dome structure.

Influence of Pile Driving-Induced Vibration on the Adjacent Slope (파일 항타진동이 인접 비탈면에 미치는 영향)

  • Kwak, Chang-Won
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.5
    • /
    • pp.27-40
    • /
    • 2023
  • A pile is a structural element that is used to transfer external loads from superstructures and has been widely utilized in construction fields all over the world. The method of installing a pile into the ground should be selected based on geotechnical conditions, location, site status, environmental factors, and construction costs, among others. It can be divided into two types: direct hammering and preboring. The direct hammering method installs a pile into the bearing layer, such as rock, using a few types of hammer, generating a considerable amount of pile driving-induced vibration. The vibration from pile driving influences adjacent structures and the ground; therefore, quantitatively investigating the effects of vibration is inevitably required. In this study, two-dimensional dynamic numerical modeling and analysis are performed using the finite difference method to investigate the influence on the adjacent slope, including temporary supporting system. Time-dependent loading induced by pile driving is estimated and used in the numerical analysis. Consequently, large surface displacement is estimated due to surface waves and less wave deflection, and refraction at the surface. The total displacement decreases with the increase of the distance from the source. However, lateral displacement at the top of the slope shows a larger value than vertical displacement, and the overall displacement tends to be concentrated near the face of the slope.

A Numerical Model for Wind-Induced Circulation in a Thermally Stratified Flow (수온성층흐름에서 바람에 의해 발생하는 순환흐름을 해석하기 위한 수치모형개발)

  • Lee, Jin-Woo;Kim, Hyung-Jun;Cho, Yong-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.10
    • /
    • pp.911-920
    • /
    • 2010
  • The closed water bodies, such as reservoirs and lakes, could be contaminated by an inflow of pollutants in the upstream as well as a stratification caused by seasonal natural phenomena. The vertical circulation particularly plays an important role in reduction of environmental pollutants. The factors of the vertical circulation are the temperature, wind, thermal diffusivity and sunlight. The wind is probably the most significant factor among them. Thus, it is necessary to describe the validation and application of a three-dimensional numerical model of wind-induced circulation in a thermally stratified flow. In this paper, a three-dimensional numerical model for the thermally stratified flows is presented. The model is conducted in three steps to calculate the velocity components from the momentum equations in x- and y- axis directions, the elevations from the free surface equation and the temperature from the scalar transport equation. Numerical predictions are compared with available analytical solutions for the sloshing free surface movement in a rectangular basin. The numerical results generally show a reasonable agreement with analytical solutions. And the model is applied to the circulation for the wind induced flow in a thermally stratification. Consequently, the developed model is validated by two verifications and phenomena of the internal flow.

Evaluation of Seismic Performance for Various Types of Pile Head of Landing Pier (잔교식 안벽에서 말뚝 두부형식에 따른 내진성능 평가)

  • Jang In-Sung;Kwon O-Soon;Park Woo-Sun;Jeong Weon-Mu
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.17 no.2
    • /
    • pp.70-79
    • /
    • 2005
  • Most of landing piers in Korea employ the combination of vertical piles and batter piles, which shows good efficiency in static lateral resistance but poor seismic performance. Many attempts have continuously been made to increase the seismic performance of batter piles with various aseismatic systems. In this study, new types of aseismatic system were developed by use of rubber and ball bearing, and shaking table tests and 3 dim. numerical analyses were performed in order to compare the seismic performance for various types of pile head. The test and numerical analysis results show the high seismic performance of newly proposed systems and the applicability off dim. numerical analysis considering the non-linear behaviour of rubber and ball bearing systems.

Finite Element Analysis of Continuous Beam Vibration under Pedestrian Loading Considering Moving Mass Effect (이동 질량 효과를 고려한 연속 보의 보행하중 진동 유한요소 해석)

  • Park, Wonsuk
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.5
    • /
    • pp.309-316
    • /
    • 2022
  • This study proposes a finite element analysis method that can analyze the vibration of a beam by considering the inertia effect of moving masses in a vertical direction. The proposed method is effective when a precise interaction analysis is not required. The inertial effects of the moving masses are included in the equation of motion, and the interaction forces between the masses and the beam are considered only as external loads. Time domain analyses were performed using Abaqus, a general-purpose finite element analysis software, and an implementation method using multi-point constraints wais presented to link the displacements of the beam element nodes and moving rigid masses. The proposed method was verified by comparing its solution with that obtained using an existing analytical method, and the analysis results for continuous beam vibrations under dynamic gait loadings were used to examine the mass effect of pedestrians.

Floc Behaviors Due to Flocculation Process (응집현상에 의한 플럭의 거동 변화)

  • Son, Minwoo;Park, Byeoung Eun;Byun, Jisun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.253-253
    • /
    • 2019
  • 유사의 이동은 하천, 해안 지역과 같은 수계에서 하상의 변동, 침식과 퇴적을 일으켜 지형적인 변화를 초래한다. 유사의 이동은 유사의 특성과 유체의 유수동역학적 특성에 의해 결정되며 유체특성 간의 복잡한 상호 작용에 의해 변화한다. 유사가 가지는 점착성은 유사의 특성에 큰 영향을 끼친다. 입자의 크기가 매우 작은 점착성 유사는 그 표면이 가지는 전자기적 점착력에 의해 주위의 1차 입자나 다른 작은 알갱이들이 서로 뭉치는 응집과 충돌에 의해 크기가 작아지는 파괴의 과정을 겪는다. 이 과정을 응집현상이라고 하며 응집현상을 통해 점착성 유사의 크기와 밀도, 침강속도는 계속해서 변화한다. 따라서 점착성 유사의 응집거동 고려한 유사 이동 연구는 필수적이다. 과거 연구의 많은 사례에서 유사의 크기와 농도는 비례 관계를 가지는 것이 일반적이라 알려져 있다. 그러나 실제 현장에서 측정한 결과 유사의 크기와 농도가 반비례 관계를 가지는 특이점이 발견되었다. 실측 연구에서 발견된 응집거동에 따른 유사의 특성의 특이한 변화를 설명하기 위해 1차원 연직 수치 모형(1DV)을 이용하여 수치 실험을 수행하였다. 모의 수행 시, 흐름 조건을 크기와 방향이 일정한 순방향흐름(Current)에 특정 주기와 진폭을 가지는 진동 흐름(Oscillatory Flow)을 추가하여 진행하였다. 플럭의 성장과 그에 따른 입자의 크기는 많은 현상에 영향을 받는다. 그 중 응집현상의 응집 과정과 파괴 과정 중 어떤 현상이 더 우세한지 그 경쟁관계를 파악하여 플럭의 크기의 증감을 예측할 수 있게 농도(?)와 난류소산매개변수(?)를 이용하여 $c/G^{0.5}$로 매개화하였다. 실험 결과, 순방향 흐름을 제외하고 스토크스파 흐름 조건을 이용하여 진행된 모의에서는 플럭의 크기와 농도가 반비례하는 현상을 관찰할 수 없었으며 $c/G^{0.5}$ 의 변화 역시 흐름의 속도와 농도가 더 큰 지점에서 큰 값을 가지는 일반적인 결과를 나타내었다. 그러나 같은 조건에서 순방향흐름을 추가하여 모의한 결과에서는 플럭의 크기와 농도가 반비례하는 현상을 나타냈다. 연직 방향 $c/G^{0.5}$의 변화를 나타낸 그래프에서 응집과 파괴의 우세에 따라 $c/G^{0.5}$ 가 역전되는 현상을 확인하였다. 즉, 플럭의 크기는 난류의 구조와 그 영향에 의해 농도와 비례관계를 갖지 않을 수도 있다고 판단된다. 또한 본 연구에서 정상류 흐름 조건의 유무에 따라 플럭의 크기와 농도가 비례하거나 반비례하는 상반된 결과를 보였다. 정상류 흐름 조건이 난류의 강도에 큰 역할을 하며 이에 따라 비선형 관계에 영향을 끼친다는 것을 발견하였다. 그러나 흐름의 영향에 대한 더 자세한 분석은 본 연구에서 진행되지 않았으며 향후 연구 시에 분명히 고려되어야 할 사항이다.

  • PDF

Dynamic Characteristics of the Box Structure in Multi-layered Ground Under Earthquake Load (지진하중을 받는 다층지반내 박스구조물의 동적 특성)

  • Kim, In Dae;Shin, Eun Chul;Park, Jeong Jun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.1
    • /
    • pp.55-63
    • /
    • 2020
  • In this study, a scaled model test of the shaking table and a seismic analysis considering effective stresses were performed to reveal the dynamic behavior characteristics of box structures deep located in multi-layered soils upon seismic loading. The input seismic wave was operated below the ground using five seismic waves, including long period wave (Hachinohe), short period wave (Ofunato), artificial wave and real earthquakes that occurred in Gyeong-ju and Po-hang. As a result of model test and numerical analysis, the vertical displacement of box structures upon seismic loading was greater than that of horizontal direction, and it was confirmed that an increase of excess pore water pressure below the foundation ground caused a displacement. In addition, behavior of the ground and structures during artificial seismic wave appeared to be larger than real earthquake wave.