• Title/Summary/Keyword: 연약지반 지진응답

Search Result 31, Processing Time 0.023 seconds

Seismic Response of Stone Column-Improved Soft Clay Deposit by Using 1g Shaking Table (1g 진동대를 이용한 쇄석말뚝으로 개량된 연약점토 지반의 지진 응답 특성)

  • Kim, Jin-Man;Lee, Hyun-Jin;Ryu, Jeong-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.12
    • /
    • pp.61-70
    • /
    • 2010
  • A series of shaking table tests were conducted to estimate the seismic performance of soft ground deposits improved by stone column. The amplification of acceleration, shear strain, and shear wave velocity were evaluated to compare the seismic response of unimproved ground deposits with that of improved ground deposits. From the test results, it was shown that the stone column can prevent large shear deformation in ground deposits. However, it was also found that the acceleration of improved ground deposits may be amplified more than that of unimproved ground deposits when it was subjected to short periodic seismic wave. The results suggest that it is necessary to perform the ground response analysis with model experiments for both unimproved and improved ground deposits to evaluate the effect of stone column on the seismic performance of improved ground deposits.

Acceleration Variation of Surrounding Ground according to distance from Strip-Type Crushed Stone Foundation (쇄석 띠기초와의 거리에 따른 주변지반의 가속도 변화)

  • Son, Su-Won;Son, Tae-Ik;Kim, Soo-Bong;Kim, Jin-Man
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.217-223
    • /
    • 2019
  • In this study, the acceleration changes of the surrounding ground when crushed stones were installed in a strip-type were analyzed using the 1-G shaking table test. The ground was constructed from clay, and the foundation was installed using crushed stone of strip-type form. The response acceleration and response spectrum for various input seismic motions were analyzed. The change in acceleration was examined according to the adjacent distance to the strip-type crushed stone foundation. In the Hachinohe seismic motion results, there was no significant decrease in acceleration, but the maximum response acceleration for the two seismic motions was inversely proportional to the distance from the crushed stone foundation. As a result of the response spectrum analysis, the attenuation period in the long period and the short period input wave were different from each other, and the change in response spectrum affected the maximum acceleration value. As the distance from the crushed stone foundation was increased, the attenuation was larger in the period between 0.08 and 0.5 sec in the Hachinohe seismic motion, the attenuation was larger in the period of less than 0.2 seconds in the Northridge seismic motion.

Evaluation of Site-Specific Seismic Amplification Characteristics in Plains of Seoul Metropolitan Area (서울 평야 지역에 대한 부지 고유의 지진 증폭 특성 평가)

  • Sun, Chang-Guk;Yang, Dae-Sung;Chung, Choong-Ki
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.4 s.44
    • /
    • pp.29-42
    • /
    • 2005
  • Total 350 borehole profiles were selected from the database of borehole logs in Seoul, for the site-specific seismic evaluation at two 4km${\times}$4km plain areas. Equivalent-linear site response analyses for the selected 350 sites were conducted based on shear wave velocity (Vs) Profiles, which were determined from the N-Vs correlation established using borehole seismic testing results in the inland areas of Korea. Most sites were categorized as site classes C and D based on the mean Vs to 30 m in depth (Vs30) ranging from 250 to 550 m/s. The she periods of the plains in Seoul ranging between 0.1 and 0.4 sec were significantly lower than those of the western US, from which the site coefficients in Korea were derived. For plains in Seoul, the site coefficients, Fa's and Fv's specified in the Korean seismic design guide, underestimate the ground motion in short-period (0.1-0.5 sec) band and overestimate the ground motion in mid-period (0.4-2.0 sec) band, respectively, because ol the differences in the geotechnical conditions between Seoul and the western US, although the Fa's in several sites overestimate the motion due to the base Isolation effect resulted from the soft layer in soil deposit.

Comparison of Modeling Methods of a Pile Foundation in Seismic Analysis of Bridge Piers (교각의 내진설계를 위한 말뚝기초의 모델링 기법 비교)

  • 김나엽;김성렬;전덕찬;김명모
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.6
    • /
    • pp.25-32
    • /
    • 2002
  • In the seismic designing of bridges, the pile foundation of bridge piers generally have been modeled to have a fixed end for its convenience and conservative designing. The fixed-end assumption, however, produces very conservative results in terms of the pier forces. Therefore, many other design methods are evolved to consider the flexibility of the pile foundation. In this study, the response spectrum analysis was performed for a bridge pier having a pile foundation. The shear force, moment, and displacement, which occurred at the pier column under an earthquake loading, were compared to analyze the effects of the modeling method, soil condition and the input earthquake response spectrum. In most cases, the fixed-end model gives larger design forces than flexible foundation models. However, when a long period earthquake is applied to the bridge pier on a soft clay foundation, it is found that the flexible foundation models give larger design forces than the fixed-end model. In the end, the reliability of several flexible foundation models was verified by comparing their results with those of a numerical analysis that considers the soil-structure interaction phenomenon in a rigorous manner.

Seismic Fragility Evaluation of Cut-and-cover Tunnel (박스형 터널의 지진 취약도 평가)

  • Park, Duhee;Nguyen, Duy-Duan;Lee, Tae-Hyung;Nguyen, Van-Quang
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.11
    • /
    • pp.71-80
    • /
    • 2018
  • In this study, the seismic response of cut-and-cover box tunnels is evaluated from pseudo-static analyses and the fragility curves are derived. A series of site profiles were used to evaluate the effect of soil conditions. A total of 20 ground motions were used. The fragility curves were developed as functions of peak ground acceleration for three damage states, which are minor, moderate, and extensive states. The damage indices, defined as the ratio of the elastic moment to the yield moment, correlated to three damage states, were used. The curves are shown to greatly depend on the site profile. The curves are further compared to those derived in previous studies. The widely used empirically derived curves are shown not to account for the site effects, and therefore underestimate the response for soft sites.

Assessment of Response Spectrum by Dynamic Centrifuge Test for the Pile Foundation into the Clay (동적 원심모형실험에 의한 점성토 지반에 근입된 말뚝지지 기초의 응답 스펙트럼 분석)

  • Kim, Sang-Yeon;Park, Jong-Bae;Park, Yong-Boo;Kim, Dong-Soo
    • Land and Housing Review
    • /
    • v.5 no.2
    • /
    • pp.115-120
    • /
    • 2014
  • Site coefficient and amplification factor of current domestic Seismic Design Code (KBC-2009) have no consideration for the domestic ground condition in which the base rock is normally placed within 30m form the surface. Accordingly, in this study dynamic centrifugal test and analysis for pile foundation into clay were achieved. and the response spectrums of free surface and basement were compared with each other. Within the period 1sec., the measured spectral acceleration of free surface and basement was bigger than the design spectral acceleration of SC and SD site. However the measured spectral acceleration of free surface and basement for the period over 1.5sec. was smaller than the design spectral acceleration of SC site. There was no severe difference of spectral acceleration according to the upper structure, embedded depth of foundation and free surface conditions. Consequently, normal domestic apartment housing for the period range over 1.5sec. could be design more economically applying these test result.

Inelastic Analysis of Steel Frame Structures with Viscoelastic Damper (점탄성 감쇠기가 설치된 철골조 건물의 비탄성 해석)

  • 김진구;최현훈
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.13 no.2
    • /
    • pp.271-278
    • /
    • 2000
  • In this study the effect and applicability of viscoelastic dampers on the seismic reinforcement of steel framed structures are investigated in the context of the performance based design approach. The effect of the damper on dissipating the input seismic energy was investigated with a single degree of freedom system. For analysis models a five-story steel frame subjected to gravity load, a ten-story and twenty-story structure subjected to gravity and wind load were designed. The code-specified design spectrums were constructed for each soil type and performance objective, and artificial ground excitation records to be used in the nonlinear time history analysis were generated based on the design spectrums. Inter-story drift was adopted as the primary performance criterion. According to the analysis results, all model structures turned out to satisfy the performance level for most of the soil conditions except for the soft soil(operational level). It was also found that the seismic performance could be greatly enhanced, and the structures were led to behave elastically by installing viscoelastic dampers on appropriate locations.

  • PDF

Study on Application of Wave Travelling Effect and Local Site Effect to Design Standard for Analysing Seismic Behavior of Long-Span Cable-Stayed Bridge (장대사장교의 지진거동 분석시 지반특성 및 파동전달효과를 고려한 설계기준 적용에 대한 고찰)

  • Park, Youn-Soo;Song, Young-Bong;Hyun, Ki-Hwyun;Lee, Soon Nam;Yang, Won Yeol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.1
    • /
    • pp.167-174
    • /
    • 2008
  • Number of long-span bridge construction has been increased recently so that seismic consideration of design has become significant. To adapt such significance to design, seismic design in the newly revised 'Cable Steel Bridge Design Handbook' specifies some of wave travelling effect and local site effect. In this study, a cable-stayed bridge with main span of 500m is analysed having variables of uniform excitation, wave travelling effect, and wave travelling effect plus local site effect. Result shows that wave travelling effect in cable-stayed bridge affects considerably to its seismic response under weak soil condition even though the span length is relatively short. What's more, regardless of soil type, the seismic response has become higher for analysis with wave travelling effect and local site effect than with wave travelling effect only. Consequently, in seismic response analysis of long-span bridge, consideration should be given to application of wave travelling effect and local site effect.

Evaluation of the Influence of Shear Strength Correction through a Comparative Study of Nonlinear Site Response Models (비선형 지반구성모델의 비교를 통한 전단강도 보정이 부지응답해석에 미치는 영향 평가)

  • Aaqib, Muhammad;Park, Duhee;Kim, Hansup;Adeel, Muhammad Bilal;Nizamani, Zubair Ahmed
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.12
    • /
    • pp.77-86
    • /
    • 2020
  • In this study, the importance of implied strength correction for shallow depths at a region of moderate to low seismicity with primary focus on its effect upon site natural period and mean period of the ground motion is investigated. In addition to the most commonly used Modified Kondner-Zelasko (MKZ) model, this paper uses a quadratic/hyperbolic (GQ/H) model that can capture the stress - strain response at large strains as well as small strain stiffness dependence. A total of six site profiles by downhole tests are used and 1D site response analyses are performed using three input motions with contrasting mean periods. The difference between non-corrected and corrected analyses is conditional on the site period as well as mean ground motion period. The effect of periods is analyzed by correlating them with the effective peak ground acceleration, maximum shear strains and amplification factors. The comparative study reveals that the difference is more prominent in soft sites with long site periods. Insignificant differences are observed when soil profiles are subjected to ground motion with very short mean period.

A Study on Isolation Performance of High Damping Rubber Bearing Through Shaking Table Test and Analysis (진동대 실험 및 해석을 통한 고감쇠 고무받침의 면진성능 연구)

  • Kim, Hu-Seung;Oh, Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.601-611
    • /
    • 2016
  • The research, development and use of seismic isolation systems have been increasing with the gradual development of structure safety assurance methods for earthquakes. The High Damping Rubber Bearing (HDRB), one type of seismic isolation system, is a Laminated Rubber Bearing using special High Damping Rubber. However, as its damping function is slightly lower than that of the Lead Rubber Bearing, a similar seismic isolation system, its utilization has not been high. However, the HDRB has a superior damping force to the Natural Rubber Bearing, which has similar materials and shapes, and the existing Lead Rubber Bearing has a maleficence problem in that it contains lead. Thus, studies on HDRBs that do not use lead have increased. In this study, a test targeting the HDRB was done to examine its various dependence properties, such as its compressive stress, frequency and repeated loading. To evaluate the HDRB's seismic performance in response to several earthquake waves, the shaking table test was performed and the results analyzed. The test used the downscaled bridge model and the HDRB was divided into seismic and non-seismic isolation. Consequently, when the HDRB was applied, the damping effect was higher in the non-seismic case. However, its responses on weak foundations, such as in Mexico City, represented increased shapes. Thus, its seismic isolator.