• Title/Summary/Keyword: 연약사면

Search Result 67, Processing Time 0.022 seconds

Estimation of Undrained Shear Strength of Clay under Failed Slope (사면파괴 하부 점토지반 비배수강도의 평가)

  • Lee, Seung-Hyun;Han, Jin-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5572-5577
    • /
    • 2012
  • Results of in-situ test, laboratory test and strength prediction method for the soft soil underlain by failed road embankment were compared each other. Comparing cone penetration test results with the field vane test results it can be seen that cone factor is 12. Undrained shear strengths determined from the cone factor which was predicted by prediction equation were smaller than those obtained from field vane tests. Among the prediction methods Jamiolkowsky's method gave close strengths to the measured undrained shear strengths by field vane tests and strength ratio were 0.88~1.23.

Failure Prediction for Weak Rock Slopes in a Large Open-pit Mine by GPS Measurements and Assessment of Landslide Susceptibility (대규모 노천광 연약암반 사면에서의 GPS 계측과 위험도평가에 의한 파괴예측)

  • SunWoo, Choon;Jung, Yong-Bok;Choi, Yo-Soon;Park, Hyeong-Dong
    • The Journal of Engineering Geology
    • /
    • v.20 no.3
    • /
    • pp.243-255
    • /
    • 2010
  • The slope design of an open-pit mine must consider economical efficiency and stability. Thus, the overall slope angle is the principal factor because of limited support or reinforcement options available in such a setting. In this study, slope displacement, as monitored by a GPS system, was analyzed for a coal mine at Pasir, Indonesia. Predictions of failure time by inverse velocity analysis showed good agreement with field observations. Therefore, the failure time of an unstable slope can be roughly estimated prior to failure. A GIS model that combines fuzzy theory and the analytical hierarchy process (AHP) was developed to assess slope instability in open-pit coal mines. This model simultaneously considers seven factors that influence the instability of open-pit slopes (i.e., overall slope gradient, slope height, surface flows, excavation plan, tension cracks, faults, and water body). Application of the proposed method to an open-pit coal mine revealed an enhanced prediction accuracy of failure time and failure site compared with existing methods.

Cause of Rall Road Slope Failure and Determination of Soil Strength for Remedy (철도사면파괴 원인 및 대책공법 적용을 위한 강도정수 결정)

  • Lee, Seung-Hyun;Kim, Byoung-Il
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.3 s.14
    • /
    • pp.25-31
    • /
    • 2004
  • Rail road slope can be fatted because of existence of unexpected soft subsoil. Purpose of this study is verifying the cause of rail road slope failure and determination of soil strength for remedy. Drilling some boreholes, cone penetration test and field vane test were executed in order to find out the cause of slope failure. In addition, laboratory test was conducted in order to determine soil strength of soft soil sampled as undisturbed state. As a result of both the in-situ and the laboratory tests, the cause of slope failure is thought to be propagation of failure zone by progressive rupture of overconsolidated clay Soft soil strength was determined through back analysis of the failed slope.

A Study on Replacement Behaviour of Soft Soil by Centrifuge Modelling Test (원심모형시험을 통한 연약지반의 강제치환거동 연구)

  • 이승원;이영남
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.6
    • /
    • pp.141-151
    • /
    • 2000
  • 본 연구에서는 토사나 사석을 이용하여 자체를 축조하는 과정에서 발생하는 연약지반의 강제치환거동을 연구하기 위하여 다양한 시험조건에 대한 원심모셩을 수행하였다. 제체축조에 따른 연약지반의 강제치환거동은 제체의 성토시공방법, 성토재의 입경, 연약지반의 종류와 강도 등에 따라 맣은 차이를 보였는데, 특히 성토과정 중에 발생하는 과잉간극수압의 크기와 밀접한 상관관계를 보였다. 급속시공인 경우에 연약지반의 파괴영역은 회적으로 확대되고 성토사면의 기울기는 완만해졌으며, 성토재의 입경이 클수록 치환깊이가 증가하고 성토사면의 기울기가 급하게 형성되었다. 그리고 동일점토에서는 지반의 강도가 클수록 치환량이 적었지만, 점토의 종류가 다른 경우에는 지반내 발생하는 과잉간극수압의 크기와 소산성조에따라 치환거동이 많은 영향을 받는 것으로 나타났다.

  • PDF

Lateral Movement of Quaywall on Soft Grounds (연약지반에 설치된 안벽구조물의 측방이동 평가)

  • Hong, Won-Pyo;Lee, Kwang-Wu;Cho, Sam-Deok
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.11
    • /
    • pp.5-16
    • /
    • 2008
  • Field monitoring data of nine sites were investigated to suggest an evaluation method on lateral movement of the quaywall on soft grounds. It was found that in order to evaluate the lateral movement of quaywalls with foundation piles such as the landing pier, the safety factor of slope should be applied with consideration of the stabilizing effect of the piles. If the required safety factor of slope is greater than 1.6 in slope stability analysis with consideration of the stabilizing effect of the piles, the quaywalls are considered to be safe against lateral movement. On the other hand, for the gravity-type quaywalls such as the caisson type quaywall, the required safety factor of slope should be greater than 1.3.

Prediction of Lateral Flow due to Embankments for Road Construction on Soft Grounds with Vertical Drains (연직배수재가 설치된 연약지반 상에 도로성토로 인한 측방유동 발생 예측)

  • Hong, Won-Pyo;Kim, Jung-Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6C
    • /
    • pp.239-247
    • /
    • 2012
  • Some methods were proposed to predict lateral flow due to embankments for road constructions on soft grounds, in which vertical drains were placed. In order to investigate the prediction methods of lateral flow, 200 field monitoring data for embankments in thirteen road construction sites at western and southern coastal areas of the Korean Peninsula were analyzed. For analyzing the relationship between the safety factor of embankment slope and the horizontal displacement in soft grounds where horizontal drain mats were placed, it was reliable to apply the maximum horizontal displacement in soft ground instead of the horizontal displacement at ground surface. The maximum horizontal displacement was developed less than 50mm in fields where the safety factor of slope was more than 1.4, while the one was developed more than 100mm in fields where the safety factor of slope was less than 1.2. In safe fields where the maximum horizontal displacement were developed within 50mm, lateral flow would not happen since shear deformation was not appeared. On the other hand, shear failure would happen in the fields where the maximum horizontal displacement were developed more than 100mm. In such fields, embankments might be continued after some appropriate countermeasures should be prepared. Safe embankments can be performed on soft grounds, in which the stability number is less than 3.0 and the safety factor for bearing is more than 1.7. However, if the stability number is more than 4.3 and the safety factor for bearing is less than 1.2, shear deformation would begin and even shear failure would happen.

Stability of Rubble Monds on Soft Grounds Improved by Deep Soil Mixing Method (심층혼합처리 연약지반상 사석제의 안정성)

  • Hong, Won-Pyo;Kim, Gyun;Song, Young-Suk
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.5
    • /
    • pp.55-62
    • /
    • 2000
  • 심층혼합처리공법에 의해 개량된 연약지반상에 사석제를 축조한 후 배면매립을 실시할 경우 사석호안의 변형거동을 관찰하기 위해 계측을 실시하였다. 개량지반상에 사석호안을 축조하기 위한 설계기준을 마련하기 위하여 유한요소법을 이용한 지반변형해석과 Bishop의 간편법을 이용한 사면안정해석을 실시하였다. 이들 해석을 사석제부, 연약지반부 그리고 뒷채음성토부의 토질조건 및 형상이 다른 여러 경우에 대하여 실시하여 그 결과를 서로 비교 분석하였다. 즉, 해석결과를 이용하여 사석제 정사부에서의 수평변위량과 침하?을 호안의 사면안정률과 연과지어 검토하였다. 본 연두결과 사석호안의 사면안전률 1.3보다 낮을 경우 상당히 큰 지반변형이 발생하는 것으로 나타났다.

  • PDF

Stability of Bridge Abutments on Soft Ground Undergoing Lateral Flow (측방유동 연약지반상 교대의 안정성)

  • 홍원표;송영석;신도순;손규만
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.4
    • /
    • pp.199-208
    • /
    • 2001
  • 본 연구의 목적은 교대가 설치된 지반의 사면안전율과 교대측방변위의 관계를 분석하여 교대의 측방이동 판정기준을 마련하고자 함에 있다. 이를 위하여 국내의 연약지반에 설치된 30개 교대의 측방이동사례를 조사하고, SLOPILE (Ver 2.0)프로그램을 이용하여 교대의 측방변위와 교대기초말뚝의 사면안정효과를 고려한 사면안정해석을 실시한다. 해석결과 교대기초말뚝의 실측측방변위를 고려할 경우 1.8이상 되어야 한다. 또한, 교대기초말뚝의 허용측방변위량에 따른 사면안정 해석결과, 교대의 허용측방변위가 작게 규정될수록 사면안정성에 기여하는 말뚝의 효과는 감소하고 있음을 알 수 있다.

  • PDF

Delineation of the Slip Weak Zone of Land Creeping with Integrated Geophysical Methods and Slope Stability Analysis (복합 지구물리탐사와 사면 안정해석 자료를 이용한 땅밀림 지역의 활동연약대 파악)

  • Lee, Sun-Joong;Kim, Ji-Soo;Kim, Kwan-Soo;Kwon, Il-Ryong
    • The Journal of Engineering Geology
    • /
    • v.30 no.3
    • /
    • pp.289-302
    • /
    • 2020
  • To determine the shallow subsurface structure and sliding surface of land creeping in 2016 at Hadong-gun, Gyeongsangnam-do, geophysical surveys (electric resistivity, and refraction seismic methods, borehole televiewer) and slope stability analysis were conducted. The subsurface structure delineated with borehole lithologies and seismic velocity structures provided the information that the sediment layer on the top of the slope was rather as thick as 20 m and the underlying weathered rock (anorthosite) was thinner than 1 m. Based on the tension cracks observed during the geological mapping, televiewer scanning was performed at the borehole BH-2 and detected the intensive fracture zones at the ground-water level, associated with the slip weak zones mapped in dipole-dipole electrical resistivity section. Downslope sliding and slightly upward pushing at the apex of high resistive bedrock explains the curved slip plane of the land creeping. Such a convex structure might play a role of natural toe abutment for preventing the downward development of slip weak zones. In slope stability analysis, the safety factors of the slip weak zone are calculated with varying the groundwater levels for dry and rainy seasons and the downslope is founded to be unstable with safety factor of 0.89 due to fully saturated material in rainy season.

Measurement of Soft Ground Foundation and Rock Slope Behavior Using Spiral Bolt Strain Gauge (스파이럴 볼트 변형률계를 이용한 연약지반기초 및 암반사면 거동 계측)

  • Kang, Seong-Seung;Hirata, Atsuo;Jeong, Seong-Hoi;Lee, Woo-Ram;Je, Dong-Kwang;Kim, Dae-Hyeon
    • Tunnel and Underground Space
    • /
    • v.20 no.2
    • /
    • pp.105-111
    • /
    • 2010
  • This study is to consider applicability of spiral bolt strain gauge as an instrument measuring behavior of soft ground foundation and rock slope. When the instrument was installed on the ground, it can be useful to identify the state of ground behavior because it has the characteristics of flexibility, as well as to apply the ground reinforcement because it has higher pull-out resistance to the ground. From the measurement of behavior to soft ground foundation, the strain shows a stable state in the beginning, then was observed significant change in the upper and the middle of spiral bolt strain gauge after 400 days. This is analyzed that ground loosening, which is due to occurred frequent earthquake of magnitude 1~2 with increased rainfall, lead to the instability of the ground. From the measurement of behavior to rock slope, the strain shows a stable state with very little change in a period of 0~50 days and the biggest strain at 4.2 m (P6) in a period of 50~100 days, then other places except P6 was maintained at a stable state in a period of 100~160 days. The reason is analyzed because that blasting for excavated limestone surrounding was affected to the largest at P6. However, based on the size of strain change by behavior of the soft ground foundation and rock slope, it is considered that the present condition are not effected on stability of retaining structure and rock slope. In conclusion, the proposed spiral bolt strain gauge can be useful to measure behavior of soft ground foundation and rock slope, and also to be measured behavior as well as reinforcement of the target ground.