• Title/Summary/Keyword: 연속거동

Search Result 692, Processing Time 0.031 seconds

Behavior of Slip Force in Continuous Flate Casting (평판 강혼 주조용 연주기의 Slip Force 거동에 대하여)

  • Si Young Kim
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.17 no.2
    • /
    • pp.85-91
    • /
    • 1981
  • An equation was derived which describes the slip force that occurs at the casting of initial state due to unequilibrium with support bar weight, liquid metal, casting velocity, thickness, control roller, hydraulic motor and etc. The slip force equations are solved on the basis of velocity, gravity and thickness in casting ingot. In this paper the auther assumed that the other mechanisms are normal. The behaviour of slip force in many characteristics is calculated as a function of velocity, gravity and thickness with variation. The conclusion with this phenomena is reached that the present theory realistically predicts the growth of slip force in a flat plate ingot continuous casting machine.

  • PDF

Analysis of the Hydrological Responses Changes of Paddy Fields in Drought Season (가뭄 발생에 따른 논에서의 수문학적 거동 변화 분석)

  • Park, Sanghyun;Kim, Hyeonjun;Jang, Cheolhee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.254-254
    • /
    • 2020
  • 우리나라의 주요 식량은 쌀이기 때문에 논 경작이 매우 활발한 국가이며 국토전체면적의 약 8.27%가 논으로 구성되어 있다. 그렇기 때문에 우리나라 유역을 대상으로 수문 모델을 모의함에 있어서 유역 내 논에서의 수문학적 반응을 살펴보는 것은 정확한 유출분석을 위해 반드시 필요하다. 본 연구에서는 물리적 매개변수 기반의 물 순환 해석 모형인 CAT(Catchment Hydrologic cycle Assessment Tool)을 이용하여 충청남도 보령시에 위치한 보령댐 유역을 대상으로 일 자료기반의 유출모의를 수행하였다. CAT은 논에서의 담수심과 물꼬높이 등을 고려한 모듈을 포함하고 있기 때문에 우리나라 논에서의 유출특성을 반영한 유역 유출 모의가 가능하다. 연구기간은 2000년부터 2017년으로 총 18년의 강우, 유출 및 기상자료를 수집하여 전체 기간에 대해 모의하였다. 전체 기간 모의 결과에 대한 유출률과 토양수분을 분석하여 연속된 평년기간(2003년 - 2005년)과 연속된 가뭄년 기간(2015년 - 2017년)으로 시나리오를 구분하였으며, 각 3년 기간으로 구분된 두 가지 시나리오에 대한 논에서의 수문학적 거동 변화를 토양수분과 지하수수위를 중심으로 비교 및 분석하였다.

  • PDF

Time-Dependent Behavior of Partially Composite Beams (부분 강합성보의 시간의존적 거동해석)

  • 곽효경;서영재
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.13 no.4
    • /
    • pp.461-473
    • /
    • 2000
  • This paper deals with a numerical model for the time-dependent analysis of steel and concrete composite beams with partial shear connection. A linear partial interaction theory is adopted in formulation of structural slip behavior, and the effect of concrete creep and shrinkage are considered. The proposed model is effective in simulating the slip behavior, combined with concrete creep and shrinkage, of multi-span continuous composite beams. Finally, correlation studies and several parameter studies are conducted with the objective to establish the validity of the proposed model.

  • PDF

Longitudinal Dynamic Behavior of KASR-Bridge Installed Creep-Couplers (Creep-Coupler가 설치된 KHSR 교량으 종방향 동적거동)

  • 곽종원
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.4
    • /
    • pp.111-116
    • /
    • 2000
  • 경간사이에 creep-coupler가 설치된 경부 고속철도 교량에 TGV-K 열차의 제동에 의한 교량의 종방향 동적거동을 해석하였다. 교량은 40m 길이의 2경간 연속교이며, 종방향 충격 하중을 인접 경간 혹은 교대로 전달하기 위한 목적으로 인접하고 있는 두 교량 사이의 creep-coupler가 설치되었다. 철도교의 경우에는 레일에 대한 종방향 축력검토가 매우 중요하므로, 이를 지지하고 있는 교량의 하부구조(교각과 기초)의영 향을 고려한 교량의 동적거동해석이 요구된다. 본 연구에서는 TGV-K의 실제 제동하중에 의한 KHSR(Korea high speed railway)에 건설중인 실제교량의 동해석을 하부구조와 동특성치를 고려하여 수행하였다. TGV-K는 객차사이에 대차가 위치하므로 전체 열차의 모델링이 한꺼번에 이루어 져야한다. 동핵석을 위해서 열차의 3차원 수치모델링이 이루어졌다. TGV-K의 제동은 동력차의 전기적인 제동에 의한 회생제동력(regenerative braking force)과 객착의 기계적인 판제동(disk braking)으로 이루어진다. 이러한 제동작용의 고려에 실제 TGV-K의 제동함수가 사용되었다.

  • PDF

Study on Dynamic Responses of Bridges Using High-speed Railway Vehicle Models (고속전철차량모형화에 따른 교량의 동적거동에 관한 연구)

  • 김상효;박흥석;허진영
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.12 no.4
    • /
    • pp.629-638
    • /
    • 1999
  • 본 연구에서는 고속철도에서 차량·교량 구조물의 상호작용을 가능한 정밀하게 취급할 수 있는 3차원 해석모형을 개발하였다. 경부고속철도 교량형식인 PSC 박스거더 교량을 40m 단순 와 25-40-25m 3경간 연속 에 대해 뼈대요소를 사용하여 3차원으로 모형 하였으며, 궤도의 불규칙성은 정상확률과정으로 가정하고, 지수 스펙트럼 밀도함수를 사용하여 궤도의 형상을 생성시켰다. 열차는 경부고속철도 차량 하중효과가 가장 큰 동력차 만을 대상으로 17 자유도 모형과 38 자유도 모형으로 분리하여 개발하였다. 다양한 조건에 대한 분석결과를 검토하면 여러 가지 상황에서 38 자유도 모형의 필수 성이 보여지고 있다. 특히 교량의 솟음 및 장기 처짐에 의한 궤도형상변화가 있는 경우에는 반드시 38 자유도 모형이 적용되어야 하는 것으로 분석되었다. 또한 제동하중이 작용할 때 쏠림 효과에 의한 영향이 큰 것으로 평가되어, 제동에 의한 교량의 동적 거동은 종변 위에 대한 자유 도를 고려할 수 있는 주행차량모형으로 해석되어야 함이 규명되었다.

  • PDF

Analysis of Slope Fracturing using a Terrestrial LiDAR (지상라이다를 이용한 사면파괴 거동분석)

  • Yoo, Chang-Ho;Choi, Yun-Soo;Kim, Jae-Myeong
    • Spatial Information Research
    • /
    • v.16 no.3
    • /
    • pp.279-290
    • /
    • 2008
  • Landslide, one of the serious natural disasters, has Incurred a large loss of human and material resources. Recently, many forecasting or alarm systems based on various kinds of measuring equipment have been developed to reduce the damage of landslide. However, only a few of these equipments are guaranteed to evaluate the safety of whole side of land slope with their accessibility to the slope. In this study, we performed some experiments to evaluate the applicability of a terrestrial LiDAR as a surveying tool to measure the displacement of a land slope surface far a slope collapsing protection system. In the experiments, we had applied a slope stability method to a land slope and then forced to this slope with a load increasing step by step. In each step, we measured the slope surface with both a total station and a terrestrial LiDAR simultaneously. As the result of Slope Fracturing analysis using all targets, the LiDAR system showed that three was 1cm RMSE on X-axis, irregularity errors on Y-axis and few errors on Z-axis compare with Total Station. As the result of Slope Fracturing analysis using continuous targets, the pattern of Slope Fracturing was different according to the location of continuous targets and we could detect a continuous change which couldn't be found using Total station. The accuracy of the LiDAR data was evaluated to be comparable to that of the total station data. We found that a LiDAR system was appropriate to measuring the behaviour of land slope. The LiDAR data can cover the whole surface of the land slope, whereas the total station data are available on a small number of targets. Moreover, we extracted more detail information about the behavior of land slope such as the volume and profile changes using the LiDAR data.

  • PDF

A Study on the Numerical Analysis of A NATM Tunnel with Consideration of Construction Procedure and Field Measurement (시공과정 및 현장계측을 고려한 NATM 터널의 수치해석적 연구)

  • Park, Choon-Sik;Kang, Man-Ho
    • Tunnel and Underground Space
    • /
    • v.20 no.1
    • /
    • pp.28-38
    • /
    • 2010
  • In order to investigate the tendency of general displacements and behaviors with respect to each construction process as well as the applicability of numerical analysis schemes, this research has focused on not only analyzing a variety of field observations made in a NATM tunnel, such as displacement of top and side, stress of shotcrete and axial strength of rock bolt, but also carrying out a series of numerical analyses. It was established from the investigation that the 2-dimensional continuum numerical analysis was the one which could more accurately predict displacement of crown and side in the area of one step excavation (patten, P1-P3), while the 2-dimensional discontinuum analysis was the most suitable scheme to study that of two step excavation (patten, P4-P6). In addition, the 2-dimensional continuum analysis enabled to appropriately predict the axial strength of rock bolt and stress of shotcrete in all the area of the tunnel. Finally, it has been possible to conclude from the study that the 3-dimensional continuum analysis should be applied to inspect the behavior and tendency with respect to each stage of the construction as well as in the case of joints, such as large turnouts where relaxation loads in both of horizontal and vertical direction are piled up.

Influence of Inclined Reinforcement around Openings on the Shear Behavior of Reinforced Concrete Continuous Deep Beams (철근콘크리트 연속 깊은 보의 전단 거동에 대한 개구부 경사 보강근의 영향)

  • Chung, Heon-Soo;Sim, Jae-Il;Yang, Keun-Hyeok
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.2
    • /
    • pp.171-178
    • /
    • 2007
  • Twelve reinforced concrete continuous deep beams having web openings within interior shear spans were tested to failure. All beams tested had the same geometrical dimensions. The main variables investigated were the opening size and amount of inclined reinforcement around openings. An effective inclined reinforcement factor combining the influence of the opening size and amount of inclined reinforcement on the structural behavior of the beams tested is proposed. It was observed that the load distribution, diagonal crack width, and load capacity of beams tested were greatly dependent on the effective inclined reinforcement factor which ranged from 0 to 0.171 for the test specimens. The higher this factor, the smaller the diagonal crack width and its development rate. A higher load capacity also developed in beams having effective inclined reinforcement factor above 0.077 than in the corresponding solid deep beams. A numerical technique based on the upper bound analysis of the plasticity theory is proposed to evaluate the load capacity of continuous deep beams having openings within interior shear spans. Predictions obtained from the proposed formulas are in good agreement with test results.

Determination of Combustion Propagation Velocity of Thermite Reaction Mixture Using Continuous VOD Measurement System (연속적 폭굉속도 측정 시스템을 이용한 테르밋 반응 혼합물의 연소전파속도 측정에 관한 연구)

  • Kim, Min-Seong;Kang, Hyeong-Min;Jeong, Sang-Sun;Jeong, Yun-Yeong;Park, Hoon;Cho, Sang-Ho
    • Explosives and Blasting
    • /
    • v.33 no.3
    • /
    • pp.21-28
    • /
    • 2015
  • The objective of this study is to develop a method for monitoring continuously the combustion propagation behavior of commercial thermite reaction mixtures using conventional continuous VOD (velocity of detonation) system. In order to monitor the combustion front propagation with elapsed time during thermite reaction, the VOD system employs two types of commercial VOD probes and one self-made probe: VOD PROBEROD-OS, VOD PROBEROD-HS and VOD PROBEROD-ES, respectively. Among the probes, the only self made VOD PROBEROD-ES successfully demonstrates the velocity of combustion propagation (VOC) with elapsed time. It was found that VOC of the thermite reaction mixture inside a steel tube has been reached around 200m/s within 100mm distance from the ignition and dramatically increased up to about twice the speed of sound in the range between 100mm and 300mm distance. Finally the VOC reached up to around 800m/s. This results imply that it is necessary to use over 300mm long cartridge of thermite reaction mixture in order to achieve normal VOC of the mixture.

Effect of Aggregate Size on the Shear Capacity of Lightweight Concrete Continuous Beams (경량콘크리트 연속보의 전단내력에 대한 골재크기의 영향)

  • Yang, Keun-Hyeok;Mun, Ju-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.5
    • /
    • pp.669-677
    • /
    • 2009
  • Twenty-four beam specimens were tested to examine the effect of the maximum aggregate size on the shear behavior of lightweight concrete continuous beams. The maximum aggregate size varied from 4 mm to 19 mm and shear span-to-depth ratio was 2.5 and 0.6 in each all-lightweight, sand-lightweight and normal weight concrete groups. The ratio of the normalized shear capacity of lightweight concrete beams to that of the company normal weight concrete beams was also compared with the modification factor specified in ACI 318-05 for lightweight concrete. The microphotograph showed that some unsplitted aggregates were observed in the failure planes of lightweight concrete beams, which contributed to the enhancement of the shear capacity of lightweight concrete beams. As a result, the normalized shear capacity of lightweight concrete continuous beams increased with the increase of the maximum aggregate size, though the increasing rate was lower than that of normal weight concrete continuous beams. The modification factor specified in ACI 318-05 was generally unconservative in the continuous lightweight concrete beams, showing an increase of the unconservatism with the increase of the maximum aggregate size. In addition, the conservatism of the shear provisions of ACI 318-05 was lower in lightweight concrete beams than in normal weight concrete beams.