• Title/Summary/Keyword: 연소하한계

Search Result 75, Processing Time 0.024 seconds

Frequency-Equivalence Ratio Correlation Analysis of Methane-Air Premixed Flame Influenced by Ultrasonic Standing Wave (I) (정상초음파의 영향을 받는 메탄-공기 예혼합화염의 주파수-당량비 상관도 분석(I))

  • Kim, Min Sung;Kim, Jeong Soo;Koo, Jaye;Kwon, Oh Chae
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.4
    • /
    • pp.37-44
    • /
    • 2015
  • An experimental study was performed for the analysis of frequency-equivalence ratio correlation in the methane-air premixed flame influenced by ultrasonic standing wave. Evolutionary features of the propagating flame were caught by high-speed camera, and the variation of flame-behavior including local velocities was investigated in detail using a post-processing analysis of the high-speed images. It was found that propagation-velocity augmentation of the methane-air premixed flame by the intervention of ultrasonic standing wave was made in leaner mixture, but the velocity diminished when the strength of chemical reaction was saturated around the slightly fuel-rich side of stoichiometry.

An Estimation of the Consequence Analysis for an Underground Installation of the LPG Storage Tanks (소형 LPG 저장탱크 매몰 설치에 대한 피해영향평가)

  • Song, Dong-Woo;Jun, Woon-Young;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.62-67
    • /
    • 2015
  • In this paper, the consequence analysis has been evaluated for the damage effects of the LPG storage tanks when they are installed on the ground or underground. They should be performed to identify measures to reduce risks for the LPG storage tanks which are more widely used. In order to conduct a damage effect evaluation of the LPG storage tanks installed underground, FDS was used to simulate the LPG storage tanks installed and housed within a facility. The maximum pressure of the storage facilities for the LPG storage tanks has been calculated from the FDS, and it's results are used as an input variable for Phast which is a commercial software for evaluating the damage effects. Getting results from the consequence analysis and computational simulations(diffusion range of LFL and UFL, jet fire or explosions) were quantitatively presented for the damage effects.

Numerical Simulation of Slab Reheating Furnace by the Zone Method (분할법을 이용한 슬래브 가열로의 전열 해석)

  • 박흥수;이용국;김기홍;조길원;민병현;김무환
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.3
    • /
    • pp.970-981
    • /
    • 1991
  • 본 연구에서는 총괄 열 흡수율법과 분할법이 지니고 있는 전열 해석상의 한계 를 보완하고 슬래브 가열로의 전열해석에 실질적으로 적용하기 위하여, 분할법으로 내 내 분위기 온도를 계산하고 이로부터 슬래브의 노내 온도이력을 예측하는 계산모델을 제시하였다. 계산모델의 유용성 확인을 위하여는, Fig.1에 보인 바와 같은 최대 슬 래브 처리량이 235ton/hr인 후판 가열로를 대상으로 하여, 노내 분위기 가스 온도 및 슬래브의 온도이력을 측정하고 이를 계산 결과와 비교하였다. 이와 아울러 연료유량, 슬래브 재로시간(residence time) 및 장입 온도등의 조업조건 변화가 분위기 가스온도 와 슬래브의 온도이력에 미치는 영향을 검토하여 가열로의 효율적 조업을 위한 자료를 제시하였다.

The Measurement and Prediction of Combustible Properties for Ethylbenzene (에틸벤젠의 연소특성치 측정 및 예측)

  • Ha, Dong-Myeong
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.169-175
    • /
    • 2014
  • For the safe handling of ethylbenzene, this study was investigated the explosion limits of ethylbenzene in the reference data. And the lower flash points, upper flash points and AITs(auto-ignition temperatures) by ignition delay time were experimented. The lower flash points of ethylbenzene by using Setaflash closed-cup and Pensky-Martens closed-cup testers were experimented $20^{\circ}C$ and $22^{\circ}C$, respectively. The lower flash points ethylbenzene by using Tag and Cleveland open cup testers were experimented $25^{\circ}C$ and $28^{\circ}C$, respectively. Also, this study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for ethylbnezene. The experimental AIT of ethylbenzene was $430^{\circ}C$. The calculated LEL and UEL by using the measured lower flash point and upper flash point were 0.93 Vol.% and 7.96 Vol.%, respectively.

The Measurement of Lower Flash Point for tert-Pentanol+n-Decane System Using Tag Open-Cup Tester (Tag 개방식 장치를 이용한 tert-Pentanol+n-Decane 계의 하부인화점 측정)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.5
    • /
    • pp.41-46
    • /
    • 2012
  • The flash point the lowest temperature at which the concentration of vapor of the substance in the air reaches the lower flammability limit(LFL), and is one of the most important physical properties used to determine the potential for fire and explosion hazards of industrial materials. The most published flash point data was for pure components and the flash points of the binary solutions that have flammable components, appear to be scarce in the literature. In the present study, the flash points of tert-pentanol+n-decane system were measured by Tag open-cup tester. The measured data were compared with the values calculated by the Raoult's law and the optimization methods based on the Wilson and NRTL equations. The calculated values by optimization methods were found to be better than those based on the Raoult's law.

The Hazard Assessment of Release and Dispersion of CNG Service Station (CNG 충전소의 누출$\cdot$확산에 대한 위험성 평가)

  • Choi Jong-Woon;Lee Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.3 s.11
    • /
    • pp.53-58
    • /
    • 2000
  • It was carried out consequence analysis(CA) of CNG (compressed natural gas) service station and we compared the results of CA of CNG service station with LPG service station which was installed by high Pressure gas law. The results of CA were that distance of CNG LFL was 1.5 times than the length of LPG LFL. Thermal radiation effect about CNG may not be showed damage of process facilities, but in the case of LPG, it was enough to have an large damage effect on a downtown. The thermal radiation of 37.5 $kw/m^2$ extended 12.6 m. Also, in the case of 12.5 $kw/m^2$ which was able to burn wood, the radiation effect of LPG is 3 times than CNG.

  • PDF

Intelligent AI-based Fine Dust Reduction Control System for Thermal Power Generation (지능형 AI기반의 미세먼지 저감 제어 시스템)

  • Lim, Sang-teak;Baek, Soon-chang;Song, Yong-jun;Baek, Yeong-tae;Choi, Cha-bong;Song, Seung-in
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2019.01a
    • /
    • pp.53-56
    • /
    • 2019
  • 본 논문에서는 화력을 이용하는 대형 파워 플랜트 설비의 미세먼지 발생량을 저감시키고 능동적으로 제어 할 수 있는 효율적인 시스템을 제안한다. 이 시스템은 기존의 고정형으로 설계된 집진기 방식의 고정부하량 한계점과 극복하고 초미세먼지 PM2.5, 미세먼지 PM10의 발생량에 따라 IoT센서 감지에 의해 지능형 알고리즘으로 효율적으로 저감 제어 처리량을 극대화하고, 미세먼지 발생량을 최소화한다. 또한 이 시스템의 차별성은 기존의 집진기에서 잡혀지지 않는 초미세먼지를 새로운 형태의 물질인 FAA(Fine-dust Adsorption Agent)를 통해 연료 연소 시 발생되는 초미세먼지 미세입자 자체를 크게 만들어 기존 설비 집진기 필터에 포집되게 하는 혁신적인 방식이다. 이번 연구를 통해 350도~1000도 열원에서 작용할 수 있는 화학물질 FAA 용액(Agent)을 개발 하였으며 지능형 AI 분사장치를 통해 연료에 첨가되어 연소 시 미세먼지를 20배~50배까지 볼륨을 확대시켜 기존 집진필터에 포집될 수 있게 동작된다. 이때, 기존 설계된 집진기의 한계(부하)용량에 상관없이 미세먼지 발생량을 상황인식 반응형 알고리즘(AI제어) 통해 분사량을 능동적으로 조절하여 미세먼지 발생량을 저감하는 진보적 혁신성을 지닌다.

  • PDF

The Study on the Compatibility of MSDS by Means of Measurement of Combustible Properties for Isobutylalcohol(IBA) (이소부틸알코올(IBA)의 연소특성치 측정에 의한 MSDS의 적정성 연구)

  • Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.75-81
    • /
    • 2014
  • For the safe handling of isobutylalcohol(IBA), this study was investigated the explosion limits of isobutylalcohol in the reference data. And the lower flash points, upper flash points and AITs(auto-ignition temperatures) by ignition delay time were experimented. By using the literatures data, the lower and upper explosion limits of isobutylalcohol recommended 1.7 Vol% and 10.9 Vol.%, respectively. The lower flash point of isobutylalcohol by using Setaflash and Penski-Martens closed-cup testers were experimented $25^{\circ}C$ and $30^{\circ}C$, respectively. The lower flash point isobutylalcohol by using Tag and Cleveland open cup testers were experimented $36^{\circ}C$ and $39^{\circ}C$, respectively. Also, this study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for isobutylalcohol. The experimental AIT of isobutylalcohol was $400^{\circ}C$.

The Study on Measurement and Prediction of Combustible Properties for Aniline (아닐린의 연소특성치의 측정 및 예측에 관한 연구)

  • Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.4
    • /
    • pp.44-50
    • /
    • 2014
  • For the safe handling of aniline, this study was investigated the explosion limits of aniline in the reference data. And the lower flash points, upper flash points and AITs(auto-ignition temperatures) by ignition delay time were experimented. The lower flash point of aniline by using Setaflash and Penski-Martens closed-cup testers were experimented $66^{\circ}C$ and $73^{\circ}C$, respectively. The lower flash point aniline by using Tag and Cleveland open cup testers were experimented $72^{\circ}C$ and $78^{\circ}C$, respectively. Also, this study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for aniline. The experimental AIT of aniline was $590^{\circ}C$. The calculated LEL and UEL by using the measured low flash point and upper flash point were 1.16 Vol.% and 8.36 Vol.%, respectively.

The Measurement and Investigation of Fire and Explosion Characteristics of Isopropyl Alcohol (이소프로필 알코올의 화재 및 폭발 특성치의 측정 및 고찰)

  • Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.3
    • /
    • pp.8-15
    • /
    • 2012
  • For the safe handling of isopropyl alcohol, the explosion limits were investigated. The lower flash points, upper flash points, fire point, and AITs(autoignition temperatures) by ignition time delay for isopropyl alcohol were experimented. By using literature data, the lower and upper explosion limits of isopropyl alcohol were recommended as 2.0 and 12.0 vol%, respectively. The lower flash points of isopropyl alcohol were experimented $12{\sim}14^{\circ}C$ by using closed-cup tester and $18{\sim}19^{\circ}C$ by using open cup tester. And the upper flash points of isopropyl alcohol was experimented $38^{\circ}C$ by using Setaflash closed-cup tester. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus was $463^{\circ}C$.