• Title/Summary/Keyword: 연성 파단

Search Result 97, Processing Time 0.027 seconds

Axial Behavior of Concrete Cylinders Confined with FRP Wires (FRP 와이어 보강 콘크리트 공시체의 압축거동)

  • Cho, Baiksoon;Lee, Jong-Han;Choi, Eunsoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.5
    • /
    • pp.1765-1775
    • /
    • 2013
  • The application of FRP wire as a mean of improving strength and ductility capacity of concrete cylinders under axial compressive load through confinement is investigated experimentally in this study. An experimental investigation involves axial compressive test of three confining amounts of FRP wire and three concrete compressive strengths. The effectiveness of FRP wire confinement on the concrete microstructure were examined by evaluating the internal concrete damage using axial, circumferential, and volumetric strains. The axial stress-strain relations of FRP wire confined concrete showed bilinear behavior with transition region. It showed strain-hardening behavior in the post-cracking region. The load carrying capacity was linearly increased with increasing of the amount of FRP wire. The ultimate strength of the 35 MPa specimen confined with 3 layer of FRP wire was increased by 286% compared to control one. When the concrete were effectively confined with FRP wire, horizontal cracks were formed by shearing. It was developed from sudden expansion of the concrete due to confinement ruptures at one side while the FRP wire was still working in hindering expansion of concrete at the other side of the crack. The FRP wire failure strains obtained from FRP wire confined concrete tests were 55~90%, average 69.5%, of the FRP wire ultimate uniaxial tensile strain. It was as high as any other FRP confined method. The magnitude of FRP wire failure strain was related to the FRP wire effectiveness.

Axial Load Behavior of Concrete Cylinders Confined with Fiber-Sheet and Steel-Plate Composites Plate (FSP) (섬유-강판 복합플레이트로 보강된 콘크리트 압축부재의 압축성능)

  • Cho, Baik-Soon;Choi, Eunsoo;Chung, Young-Soo;Kim, Yeon-Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4A
    • /
    • pp.331-340
    • /
    • 2011
  • The application of newly developed fiber-sheet and steel-plate composite plate (FSP) as a means of improving strength and ductility capacity of concrete cylinders under axial compression load through confinement is investigated experimentally in this study. An experimental investigation involves axial load tests of two types of FSP strengthening material, two anchoring methods, and three concrete strengths. The FSP-confined cylinder tests showed that FSP provided a substantial gain in compressive strength and deformability. The performance of FRP-confined cylinders was influenced by type of the FSP strengthening material, the anchoring method, and concrete compressive strength. The FSP failure strains obtained from FSP-confined cylinder tests were higher than those from FRP-confined cylinder tests. The magnitude of FSP failure strain was related to the FSP composite effectiveness. The effects of FSP confinement on the concrete microstructure were examined by evaluating the internal concrete damage using axial, radial, and volumetric strains. From the observations obtained in this investigation, it is believed that FSP is one of the best solutions for the confinement of concrete compressive members.

A study on working limit of cold forging of carbon steel (냉간단조에 있어서 탄소강의 가공한계에 관한 연구)

  • Jae, Jin-Soo;Kang, Jong-Hun;Kang, Seong-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.7
    • /
    • pp.1081-1088
    • /
    • 1997
  • The purpose of this work is to investigate the working limit of carbon steel and forging condition of cold forging. The fracture criteria which was proposed by Oyane and Osakada was used. Compression test, hardness study and tension test by Oyane's creteria, microstructure study by Osakada's were carried out. The results were compared with each other. It was found that working limit on compressive hydrostatic stress is increased in comparison with that of tensile stress field and can be forecasted the fracture limit of closed cold forging.

Experimental Study on Progressive Collapse Resisting Capacity of Reinforced Concrete Beam-Column Sub-assemblage (RC 보-기둥 요소의 연쇄붕괴 저항 거동에 대한 실험적 연구)

  • Choi, Hyun-Hoon;Kim, Jin-Koo;Park, Kyoung-Hoon;Jeon, Yong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.450-453
    • /
    • 2009
  • 본 논문에서는 지진하중을 고려하여 충분한 연성거동이 가능하도록 배근한 철근콘크리트 횡하중 저항 골조(내진상세)와 고정하중과 적재하중만을 고려하여 설계한 중력하중 저항 골조(일반상세)를 대상으로 외부기둥과 내부기둥에 연결된 보의 연쇄붕괴 거동을 평가하기 위한 실험을 수행하였다. 일방향 가력실험 결과에 따르면 내진상세의 경우 대변형 상태에서 보의 하단철근의 파단이후 상단 압축철근이 인장력을 부담하면서 전체 보 부재는 축인장력이 작용을 하면서 힘-변위 곡선은 상승하는 현수작용이 발현되었다. 그러나 일반상세의 경우 충분한 현수작용이 발현되기 전에 보의 주근이 정착된 외부기둥 접합부의 파괴로 인하여 저항내력이 감소하였다.

  • PDF

Rigid-Plastic Finite Element Analysis of Burr Formation at the Exit Stage in Orthogonal Cutting (2차원 절삭에서 공구이탈시 발생하는 버에 관한 강소성 유한요소해석)

  • 고대철;김병민;고성림
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.4
    • /
    • pp.125-133
    • /
    • 1998
  • The objective of this study is to propose a new approach for modelling of burr formation process during orthogonal cutting when the tool exits the workpiece. This approach is based on the rigid-plastic finite element method combined with the ductile fracture criterion and the element kill method. This approach is applied to orthogonal cutting process to predict the fracture location and the fracture angle as well as the cutting force. To validate this approach, orthogonal cutting tests inside SEM(scanning electron microscope) at very low speed are carried out using A16061-T6 to observe the behavior of the material during the chip and the burr formation. The results of the experiment are compared with those of the finite element simulation.

  • PDF

Development of the technique for prediction of the hub-hole crack with the punching effect (펀칭 효과를 고려한 허브홀의 파단 예측기법 개발)

  • Lee J. S.;Ko Y. K.;Huh H.;Kim H. K.;Park S. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.10a
    • /
    • pp.362-365
    • /
    • 2005
  • The hub hole is usually formed with a flanging process followed by a blanking process of a ]tole. Since the hole is made by blanking, the blanked surface is so rough that the formability in the region is rather poor. The emerging task is to identify the formability of the blanked region in the forming simulation and to relate the criterion to the real forming process by experiments. In this paper, hole expansion tests are carried out with respect to various hole conditions to verify the hole condition effect on the hole expansion ratio. The hole of specimens is made by machining or punching. In the case of punching, two different punching clearances are used for making the hole. From the results of test, fracture mechanism of the hole expansion is explained.

  • PDF

Bond Behaviors between Ultra High Performance Concrete and Deformed Reinforcement (초고성능 콘크리트(UHPC)와 이형 철근의 부착 성능 평가)

  • Kook, Kyung Hun;Shin, Hyun-Oh;Yoo, Doo-Yeol;Yoon, Young-Soo
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.40.1-40.1
    • /
    • 2010
  • 초고성능 콘크리트(Ultra High Performance Concrete, UHPC)는 종래의 보통 콘크리트와 다른 새로운 재료로써 높은 강도와 향상된 연성을 그 특징으로 한다. 이러한 새로운 재료의 활용을 위하여 본 연구는 초고성능 콘크리트의 부착 성능을 평가하고자 하였다. 수정된 RILEM 방법을 사용하여 초고성능 콘크리트와 이형철근의 pull-out 실험을 수행하였으며 보통 콘크리트와 비교하여 5~10배에 달하는 부착강도를 확인하였다. 또한 항복강도 400MPa급 철근에 대하여 철근 직경 2배 이상의 부착 길이에서 철근의 파단 강도에 해당하는 부착 성능을 나타내었으며 400MPa급 철근과 700MPa급 고장력 철근의 실험 결과 비교로부터 초고성능 콘크리트에서 고장력 철근 활용의 효율성을 확인하였다.

  • PDF

Unified Constitutive Modeling for Low Temperature Austenitic Stainless Steel (저온용 스테인레스강의 통합 구성방정식)

  • Yoo, Seong-Won;Park, Woong-Sup;Lee, Jae-Myung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.504-507
    • /
    • 2010
  • 본 논문에서는 저온용 오스테나이트계 스테인리스강(ASS)의 온도 및 변형률 속도의 영향을 고려한 통합 구성 방정식 및 손상 모델을 제안하였다. 저온 영역에서, 304L ASS의 온도 및 변형률 속도별 인장 실험을 시행하였다. 그 결과, 변형 유기 마르텐사이트 상변태에 의해 상변태 유기 소성(TRIP)이 저온에서 현저히 나타났으며 온도 및 변형률 속도의 영향이 지대하였다. 실험 결과를 바탕으로 ASS의 저온 거동 및 특성을 규명하여 수치 모델에 반영하였다. 저온에서 일어나는 2차 경화 현상을 표현하기 위해, Bodner/Partom 점소성 구성 방정식을 수정하고 Tomita/Iwamoto 변형 유기 상변태 모델을 구성 방정식에 적용시켰다. 저온 연성 파단 현상을 표현하기 위해, Bodner/Chan 손상모델을 수정하여 접목시켰다. 제안된 모델을 유한요소 프로그램에 탑재시키고, 온도 및 변형률 속도 의존 재료 정수를 결정하였다. 저온 영역에서, 온도 및 변형률 속도별 재료 거동을 시뮬레이션하고 이를 실험 결과와 비교 및 검증하였다.

  • PDF

Behavior of Concrete Bridge Deck Using Hybrid Reinforcement System (Hybrid Reinforcement System을 이용한 콘크리트 교량상판 슬래브의 거동)

  • Park Sang-Yeol;Cho Keun-Hee
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.4 s.82
    • /
    • pp.451-458
    • /
    • 2004
  • This study describes the basic concept and the applicability of Hybrid Reinforcement System using conventional steel reinforcing bars and Fiber Reinforced Polymer bars. The concrete bridge decks are assumed to be supported by beams and reinforced with two layers of reinforcing bars. In concrete bridge deck using HRS, the top tensile force for negative moment zone on beam supports is assumed to be resisted by FRP reinforcing bars, and the bottom tensile force for positive moment zone in the middle of hem supports is assumed to be resisted by conventional steel reinforcing bars, respectively. The FRP reinforcing bars are non-corrosive. Thus, the steel reinforcement is as far away as possible from the top surface of the deck and protected from intrusion of corrosive agent. HRS concrete bridge deck has sufficient ductility at ultimate state as the following reasons; 1) FRP bars have lower elastic modulus and higher ultimate strain than steel re-bars have, 2) FRP bars have lower ultimate strain if provided higher reinforcement ratio, 3) ultimate strain of FRP bars can be reduced if FRP bars are unbonded. Test results showed that FRP and HRS concrete slabs are not failed by FRP bar rupture, but failed by concrete compression in the range of ordinary reinforcement ratio. Therefore, in continuous concrete bridge deck using HRS, steel reinforcing bars for positive moment yield and form plastic hinge first and compressive concrete fail in the bottom of supports or in the top of the middle of supports last. Thus, bridge deck consumes significant inelastic strain energy before its failure.

Evaluation of Water Absorption Phenomena into the Photo-resist Dry Film for PCB Photo-lithography Process (PCB Photo-lithography 공정에 사용되는 Photo-resist인 Dry Film에 대한 물의 확산 침투 현상평가)

  • Lee, Choon Hee;Jeong, Giho;Shin, An Seob
    • Applied Chemistry for Engineering
    • /
    • v.24 no.6
    • /
    • pp.593-598
    • /
    • 2013
  • In this study, we have evaluated the water absorption phenomenon of photoresist dry film, which is commonly used to build circuits on PCB (Printed Circuit Board) by photolithography, by using ATR-FTIR (Attenuated Total Reflectance-Fourier Transform Infrared). We have firstly observed significant change in fracture mode of dry film with respect to temperature and humidity, which we assumed the material transition from ductile to brittle. Secondly, we have established the process of absorption test for determining the diffusion coefficients of water into the dry film both with gravimeter and ATR-FTIR. We have successfully calculated the diffusion coefficients for each environmental conditions from the results which we achieved by gravimeter and ATR-FTIR. Compared to the gravimeter which is a conventional method for absorption test, the ATR-FTIR method in this study has been found to be very easy to use and have the same accuracy as gravimeter. Moreover, we are expecting to use the ATR-FTIR as an appropriate method to study the absorption phenomena related to any kinds of solvent and polymer system.