• Title/Summary/Keyword: 연마선

Search Result 45, Processing Time 0.025 seconds

Development and Evaluation of Parallel Beam Optic for X-ray (엑스선용 평행빔 광학소자 개발 및 평가)

  • Park, Byunghun;Cho, Hyungwook;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.477-481
    • /
    • 2012
  • An X-ray diffractometer which has various X-ray optics can give qualitative and quantitative information for a sample using a nondestructive analysis method. A parallel beam optic passes the parallel beam and removes divergent beam generated from an X-ray tube. The parallel beam optic used in the X-ray diffractometer was fabricated by wire cut and grading of stainless steel plates and was evaluated its performance using an X-ray imaging system. The measured parallelization of 6.6 mrad for the fabricated the parallel beam optic was a very close to the expected value of 6 mrad. An X-ray imaging technique for evaluating the parallel beam optics can estimate parallelization for each plate and can be used to other X-ray optics.

대구경 사파이어 단결정 기판의 결함 평가를 위한 X-선 토포그래피 장비 구축

  • Jeon, Hyeon-Gu;Jeong, In-Yeong;Lee, Yu-Min;Kim, Chang-Su;Park, Hyeon-Min;O, Byeong-Seong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.238-238
    • /
    • 2013
  • 사파이어 단결정은 광학 투명도, 물리적 강도, 충격 저항, 마모 부식, 높은 압력 및 온도 내구성, 생체 호환성 등 다양한 특성을 가지고 있어 다양한 분야에서 사용되고 있으며, 특히 최근에는 백색 또는 청색 LED 소자 분야에서 기판으로 주로 활용되고 있다. 이러한 사파이어 단결정 기판은 공정에서 결정 성장 조건 및 기계적 연마 등의 다양한 요인으로 결정학적 결함이 발생한다. 이러한 결정학적 결함을 제어함으로서 좋은 품질의 단결정 기판을 생산할 수 있다. 이에 따라 각종 결함 제어를 위해서 X-선, EPD, 레이저 편광법 등 다양한 방법으로 결함들을 측정하고 있다. 그 중에서도 X-선 토포그래피는 시료를 비파괴적인 방법으로 단결정의 결함 밀도와 유형 등을 파악하는데 매우 유용한 측정법이며, Lang 토포그래피로 대표되는 X-선 회절 투과법은 기판과 같은 대구경의 시료를 우수한 분해능으로 내부 결함까지 관찰할 수 있는 장점을 지니고 있다. 본 연구에서는 대구경 사파이어 단결정 기판에 내재하는 결정 결함을 확인 및 분석하기 위해 X-선 Lang 토포그래피(X-ray Lang Topography) 장비를 구축하였다. 그리고 4, 6인치 c-면 사파이어 단결정 기판의 (110), (102) 회절면의 X-선 토포그래피 측정을 통해 전위(dislocation), 스크래치(scratch), 표면데미지(surface damage), 트윈(twin), 잔류 응력(strain) 등의 결함의 유형을 식별 및 분석하였으며, 각각의 결함들의 토포그래피 이미지 형성 메커니즘에 대해 분석하였다. 이를 통해 X-선 Lang 토포그래피(X-ray Lang Topography) 장비가 대구경 사파이어 단결정 기판의 결정 결함 평가에 폭넓은 활용이 가능할 것으로 예상된다.

  • PDF

The Analysis and Comparison of the Experiments for Electro-Decontamination about Radioactive Metal Wastes (방사성 금속 폐기물의 전해제염 실험 비교 분석)

  • 강동우;박광수;문길호;엄달선
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.196-201
    • /
    • 2003
  • Decontamination means every method that can drop the level of the radioactivities from the materials contaminated with them to the allowable one. In this paper, one of the decontamination methods, the electro-decontamination was described with lots of experiments. Two test specimens contaminated with alpha ray and beta ray respectively were used to compare the decontamination factors between two rays and many experiments were performed in every electrolyte with SUS and Carbon steel test specimens. Sulphuric acid, phosphoric acid, nitric acid, citric acid and oxalic acid were used as the electrolyte. Decontamination Factors (DF) could be compared and analyzed with different electrolyte, current intensities and time.

  • PDF

Antimicrobial activity of dental polishing bur material with fluoride ion (불소이온을 함유한 연마용 버 재료의 항균력 연구)

  • Jeong, Insun;Kim, Ji-Hyun;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.201-206
    • /
    • 2020
  • Purpose: The purpose of this study is to evaluate the antimicrobial activity on the dental bur with fluoride for S. mutans. Materials and methods: 0 ppm, 300 ppm, 500 ppm, 1,000 ppm, 1,450 ppm fluoride ion is added to a specimen. S. mutans was incubated for 24 hours, the number of S. mutans were counted. Kruskal-Wallis and MannWhitney analysis were used SPSS 25.0 (IBM SPSS 25.0, Chicago, IL, USA). Results: The mean S. mutans counts of 0 ppm, 300 ppm, 500 ppm, 1,000 ppm, and 1,450 ppm were 374.0 ± 12.6, 251.0 ± 66.7, 111.4 ± 35.6, 41.6 ± 11.7 and 13.2 ± 4.6, respectively. All groups except the control and 300 ppm showed statistically significant. Conclusion: Thus, more than 500 ppm fluoride ion showed the statistically significant antimicrobial activity. 1,450 ppm group showed the highest antimicrobial activity. This study showed the clinical possibility for dental caries protection and antimicrobial activity of dental bur.

A Study on the Fatigue-Fractured Surface of Normalized SS41 Steel and M.E.F. Dual Phase Steel by an X-ray Diffraction Technique (X-선 회절에 의한 SS41 불림재와 M.E.F. 복합 조직강의 피로 파단면 해석에 관한 연구)

  • Oh, Sae-Wook;Park, Young-Chul;Park, Soo-Young;Kim, Deug-Jin;Hue, Sun-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.1
    • /
    • pp.10-18
    • /
    • 1996
  • This study verified the relationship between fracture mechanics parameters and X-ray parameters for normalized SS41 steel with homogeneous crystal structure and M.E.F. dual phase steel(martensite encapsulated islands of ferrite). The fatigue crack propagation test were carried out and X-ray diffraction technique was applied to fatigue fractured surface. The change in X-ray parameters(residual stress, half-value breadth) according to the depth of fatigue fractured surface were investigated. The depth of maximum plastic zone, $w_y$, were determined on the basis of the distribution of the half-value breadth for normalized SS41 steel and that of the residual stress for M.E.F. dual phase steel. $K_{max}$ could be estimated by the measurement of $w_y$.

  • PDF

An experimental study on the cytotoxicity of orthodontic wires (교정용 호선의 세포독성에 관한 실험적 연구)

  • Lim, Yong-Kyu;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.26 no.5 s.58
    • /
    • pp.591-599
    • /
    • 1996
  • This study was undertaken to investigate the cytotoxicity of orthodontic wires after doing various treatments to the wires. 018x025 inch Stainless steel(A) and Co-Cr(B) wires were used and each of them were divided into 4 groups. A-1 and B-1 groups were as received state, and A-2 and B-2 groups were heat treated. A-3 and B-3 groups were electropolished after heat treatment, and A-4 and B-4 groups were soldered with Ag-solder. Each group had 3 wires and these were sterilized with Ethylene Oxide gas. We used human gingival fibroblast cell culture and agar overlay technique to investigate the cytotoxicity of each group of wires. The cytotoxicity of wire was assessed using reaction index (zone index/lysis index). The findings of this study were as follows. 1. Both of the stainless steel wire and Co-Cr wire showed no cytotoxicity in as received state. 2. Heat treatment or electropolishing of the wires had no effect on the cytotoxicity of the wires 3. Soldered stainless steel wires showed a little wider zone of discoloration than soldered Co-Cr wires, but the zone index and cytotoxicity(reaction index) was not different. 4. Soldered wires showed moderate cytotoxicity in both of the wires.

  • PDF

Interfacial Defects in $SiO_2$-Glass Bond During VCR Head Fabrication (VCR 헤드 제조시 $SiO_2$박막과 유리의 계면 결함)

  • Yun, Neung-Gu;Hwang, Jae-Ung;Go, Gyeong-Hyeon;An, Jae-Hwan;Je, Hae-Jun;Hong, Guk-Seon
    • Korean Journal of Materials Research
    • /
    • v.4 no.1
    • /
    • pp.31-36
    • /
    • 1994
  • The bonding behavior of $SiO_{2}$ thin film and glass during VCR head fabrication was investigated, varying the surface roughness of substrate and the sputtering parameter. Insufficient fillings of grooves In the $SiO_{2}$ film with glass was postulated to give rise to the generation of bubble in the glass. The surface roughness of $SiO_{2}$ film was found to depend on that of substrate. The lower the deposition rate, the smoother the surface of film. The bubble free glass after bonding could be obtained using substrate polished with 0.05$\mu\textrm{m}$ $Al_2O_3$ powder under the sputtering condition of 10% oxygen pressure.

  • PDF

Cell Activity of ELID-Machined Titanium Surface (ELID 경면 연삭 가공된 티타늄 표면의 세포 활성도)

  • Kang, Jong-Ho;Lee, Myung-Hyun;Seo, Won-Seon;Lee, Suk-Won;Kwak, Tae-Soo;Choi, Heon-Jin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.3
    • /
    • pp.13-18
    • /
    • 2012
  • We investigated the cell activity of controlled titanium surface using various grinding methods including ELID (Electrolytic In-Process Dressing) grinding method. The influence of titanium surface condition by each grinding process on the cell activity was evaluated by ALP activity of MSC(Mesenchymal Stem Cells). The ALP activity of controlled surface by ELID grinding process using # 2000 wheel was higher than that of other titanium surface. The morphological, chemical properties of machined surface by grinding method was observed using various analytical method.

Study on the Establishment of Rail Grinding Criteria of High-Speed Railway Lines Considering the KTX Operation Circumstances (KTX 운행현황을 고려한 고속선 레일 연마 기준 정립에 대한 연구)

  • Kim, Man-Cheol;Kang, Tae-Ku
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.377-385
    • /
    • 2007
  • The importance of maintenance of rail surface defects is increasing more according to the KTX operation. That is because during high speed operation of rolling stock, rail surface defects may cause shortened fatigue life of rail, acceleration of track degradation and reduced ride comfort. The paper was intended to study the establishment of rail grinding criteria of high-speed railway lines considering the KTX operation circumstances. For this, the specimens of UIC 60 rail on Kyeong-Bu high-speed operation lines were collected and they were analyzed for metallographic structure and tested for the hardness. By analyzing the test results to the factors affecting the RCF causing the defects of rail surface, the study suggested the rail grinding criteria of the domestic high speed railway lines. As the factors affecting RCF, passing tonnage, running speed and track condition are considered.

  • PDF

Design of The Tool Horn for Dies Needle Horning Manufacturing (인발다이 가공을 위한 니들 호닝기용 툴혼 설계)

  • Yoon H.J.;Yoon Y.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.231-232
    • /
    • 2006
  • Ultrasonic machining technology has been developed over recent years for manufacturing the quality-assured precision parts fur several industrial application such as optics, semiconductors, aerospace and automobile application. Ultrasonic needle horning is widely used in cutting(drilling) of non-conductive, brittle workpiece materials. This paper intends to understanding of the basic mechanism of ultrasonic needle horning. And frequency analysis program is used to easily predict the natural frequency of ultrasonic vibration cutting tools.

  • PDF