• Title/Summary/Keyword: 연료관

Search Result 240, Processing Time 0.028 seconds

The Development of Tidal Power System Can be Installed in Existing Dykes - The Open Channel Experimental Verification (기존 방조제에 설치 가능한 조력발전 장치 개발 - 개수로 현장실험 검증)

  • HyukJin Choi;Dong-Hui Ko;Nam-Sun Oh;Shin Taek Jeong
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.35 no.1
    • /
    • pp.13-21
    • /
    • 2023
  • As problems such as difficulties in securing stable energy resources and global warming due to the emission of greenhouse gases due to the use of fossil fuels have emerged, interest in the development of renewable energy is increasing. Since the tidal phenomenon has a regularity that occurs regularly with a certain period, it is possible to predict accurately in advance, which has a advantage in terms of energy recovery. Therefore, various methods have been devised to utilize the tide as an energy source. Tidal power using barrages is a representative method that is widely operated, but the promotion of tidal power generation projects is being delayed or stopped due to the decrease in the level of water in the tidal basin, changes in water quality and in the ecosystem. In this study, a field experiment was conducted to develop and verify the performance of a tidal power device applicable to sea areas where dykes are already installed. As a result of carrying out four cases of experiments using two water tanks, pipe lines, open channels, weirs, and water turbine and generator, the possibility of developing a power generation system capable of 10 kW output or more and 60% efficiency or more was confirmed. These research results can be used for small-scale tidal power by utilizing the existing dykes.

Evaluation of Quality Standards of Bio-Diesel (BD100, BD20) Manufactured Using Waste Frying Oil (폐식용유를 이용하여 제조한 바이오디젤(BD100, BD20)의 품질기준 평가)

  • Na, Seong-Joo;Jeon, Byung-Gwan
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.1
    • /
    • pp.39-48
    • /
    • 2009
  • Biodiesel is estimated to be the best recycling energy source as an alternative fuel for transportation vehicles which represents the biggest share of greenhouse effect gas exhausts. Thus, in order to widely expand use of biodiesel and to enhancement its reliability, studies on quality improvement of biodiesel is needed. In this study, we have produced biodiesel(BD100, BD20) through esterification reaction using raw material of waste frying oil and analyzed compatibility with 24 items of quality criteria. As waste frying oil has high contents of unsaturated fatty acid such as Oleic acid, Linoleic acid and Linolenic acid, it is confirmed that there is no problem in using the same as a raw material of biodiesel. The result of analyzing the quality criteria items of biodiesel showed that it satisfied all the quality criteria except the oxidation stability of BD100, which was 2 hours, fatty acid methyl ester of BD20, which was 18.6w% and the filter plugging point, which was $-5^{\circ}C$. We believe that it will contribute to improved utilization of waste resources as alternative energy if studies on technology to improve quality of some items are provided.

Dynamical Study on the Blasting with One-Free-Face to Utilize AN-FO Explosives (초유폭약류(硝油爆藥類)를 활용(活用)한 단일자유면발파(單一自由面發破)의 역학적(力學的) 연구(硏究))

  • Huh, Ginn
    • Economic and Environmental Geology
    • /
    • v.5 no.4
    • /
    • pp.187-209
    • /
    • 1972
  • Drilling position is one of the most important factors affecting on the blasting effects. There has been many reports on several blasting factors of burn-cut by Messrs. Brown and Cook, but in this study the author tried to compare drilling positions of burn-cut to pyramid-cut, and also to correlate burn-cut effects of drilling patterns, not being dealt by Prof. Ito in his theory, which emphasized on dynamical stress analysis between explosion and free face. According to former theories, there break out additional tensile stress reflected at the free face supplemented to primary compressive stress on the blasting with one-free-face. But with these experimented new drilling patterns of burn-cut, more free faces and nearer distance of each drilling holes make blasting effects greater than any other methods. To promote the above explosive effect rationary, it has to be considered two important categories under-mentioned. First, unloaded hole in the key holes should be drilled in wider diameter possibly so that it breaks out greater stress relief. Second, key holes possibly should have closer distances each other to result clean blasting. These two important factors derived from experiments with, theories of that the larger the dia of the unloaded hole, it can be allowed wider secondary free faces and closes distances of each holes make more developed stress relief, between loaded and unloaded holes. It was suggested that most ideal distance between holes is about 4 clearance in U. S. A., but the author, according to the experiments, it results that the less distance allow, the more effective blasting with increased broken rock volume and longer drifted length can be accomplished. Developed large hole burn-cut method aimed to increase drifting length technically under the above considerations, and progressive success resulted to achieve maximum 7 blasting cycles per day with 3.1m drifting length per cycle. This achievement originated high-speed-drifting works, and it was also proven that application of Metallic AN-FO on large hole burn-cut method overcomes resistance of one-free-face. AN-FO which was favored with low price and safety handling is the mixture of the fertilizer or industrial Ammonium-Nitrate and fuel oil, and it is also experienced that it shows insensible property before the initiation, but once it is initiated by the booster, it has equal explosive power of Ammonium Nitrate Explosives (ANE). There was many reports about AN-FO. On AN-FO mixing ratio, according to these experiments, prowdered AN-FO, 93.5 : 6.5 and prilled AN-FO 94 : 6, are the best ratios. Detonation, shock, and friction sensities are all more insensitive than any other explosives. Residual gas is not toxic, too. On initation and propagation of the detonation test, prilled AN-FO is more effective than powered AN-FO. AN-FO has the best explosion power at 7 days elapsed after it has mixed. While AN-FO was used at open pit in past years prior to other conditions, the author developed new improved explosives, Metallic AN-FO and Underwater explosive, based on the experiments of these fundmental characteristics by study on its usage utilizing AN-FO. Metallic AN-FO is the mixture of AN-FO and Al, Fe-Si powder, and Underwater explosive is made from usual explosive and AN-FO. The explanations about them are described in the other paper. In this study, it is confirmed that the blasting effects of utilizing AN-FO explosives are very good.

  • PDF

Design of a pilot-scale helium heating system to support the SI cycle (파이롯 규모 SI 공정 시험 설비에서의 헬륨 가열 장치 설계)

  • Jang, Se-Hyun;Choi, Yong-Suk;Lee, Ki-Young;Shin, Young-Joon;Lee, Tae-Hoon;Kim, Jong-Ho;Yoon, Seok-Hun;Choi, Jae-Hyuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.157-164
    • /
    • 2016
  • In this study, researchers performed preliminary design and numerical analysis for a pilot-scale helium heating system intended to support full-scale construction for a sulfur-iodine (SI) cycle. The helium heat exchanger used a liquefied petroleum gas (LPG) combustor. Exhaust gas velocity at the heat exchanger outlet was approximately 40 m/s based on computational thermal and flow analysis. The maximum gas temperature was reached with six baffles in the design; lower gas temperatures were observed with four baffles. The amount of heat transfer was also higher with six baffles. Installation of additional baffles may reduce fuel costs because of the reduced LPG exhausted to the heat exchanger. However, additional baffles may also increase the pressure difference between the exchanger's inlet and outlet. Therefore, it is important to find the optimum number of baffles. Structural analysis, followed by thermal and flow analysis, indicated a 3.86 mm thermal expansion at the middle of the shell and tube type heat exchanger when both ends were supported. Structural analysis conditions included a helium flow rate of 3.729 mol/s and a helium outlet temperature of $910^{\circ}C$. An exhaust gas temperature of $1300^{\circ}C$ and an exhaust gas rate of 52 g/s were confirmed to achieve the helium outlet temperature of $910^{\circ}C$ with an exchanger inlet temperature of $135^{\circ}C$ in an LPG-fueled helium heating system.

A survey on the habit of dieting and food constrained by superstition (식습관(食習慣)과 금기식(禁忌食)에 관(關)한 조사(調査))

  • Lee, Geum-Yeong;Suh, Myung-Sook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.2 no.1
    • /
    • pp.73-80
    • /
    • 1973
  • 1. Generally speaking, our people have been carrying out the government policy of using grains other than rice comparatively well. But it is desirable that the government heirs the whole nation as well as the farmers to understand better the scientific meaning of using foods made from the flour of various grains. This will greatly improve the nation's eating habits, for it will make people discard the habit of eating only boiled-rice, which will not only improve our national health but will also increase the national income. 2. For the purpose of improving health and developing intellectual faculties of our mind, we had better, if possible, get much protein from plants(especially beans) which we can obtain more readily than from animals. However if we must use animal protein, we should dependonly on livestock. Pregnant women and new-born children must not be in ill health because of malnutrition caused by following groundless superstitions about foods: for example, some religions forbid the use very healthful foods or some traditional conventions do the blend of certain foods together with other victuals. 3. It is good that we conquer the difficulty of living in the season of spring poverty by having other substitute for regular victuals. But it requires us to pay a careful attention to the food and to do research on many foods problems such as food pollution. Farmers should cooperate with each other and help those who have very little arable land, or even those who have no place for cultivating, to grow miscellaneous cereals on the land which other farmers don't use that year. 4. On the whole, farmers have a good appetite for any, food, whatever it is. Neverthless, because they aren't econmically well-off, they generally eat hot meals only for breakfast and supper in the busy faming season. They eat a tepid lunch which, they think saves time and cooking fuel. In conclution, I feel sorry that many village farmers still steeped in conventional thought and superstition are inclined to have an unbalanced diet of boiled-rice and that they continue not to use the floor from other grains all the year round. when these unscientific dieting customs mentioned above are discarded, we will be able to enjoy good health, better knowledge or intellegence, and higher income. Then we will ba able to make our present lives more self-reliant and self-supporting.

  • PDF

Studies on the Tissue Culture of Some useful woody species (유용수종(有用樹種)의 조직배양(組織培養)에 관(關)한 연구(硏究))

  • Kim, Jai Saing;Lee, Sam Sup
    • Journal of Korean Society of Forest Science
    • /
    • v.43 no.1
    • /
    • pp.6-13
    • /
    • 1979
  • In order to substract the time and cost of propagation for inducing the haploid plants per each species. 500 anthers of late uninucleate microspore on early binucleate microspore stage of Robinia pseudoacacia (Fuel tree) Punius granatum (Ornamental tree). Aleurites fordii (Faty tree) and Styrax japonica (Silvicultural tree) were cultured on the modified Murashige and Skoog's medium supplemented with Kinetin, 2.4-D and NAA as growth regulators. And I observed the samples of cultured anthers under the microscope which were made by Microtoming method and Paraffin method. The results were summarized as follows: 1) Among 500 cultured anthers per each species, anther numbers inducing the diploid callus were as follow: Styrax japonica 20 (4% for the species total); Aleurites fordii 10 (2% for the species, total) and Punica granatum 45 (9% for the species total) were showed. 2) 2n Callus were induced from anther wall. but haploid callus were induced from anther locule. 3) Haploid callus were induced only in 25 anthers (5% for the species total) of Robinia pseudoacacia. 4) These haploid callus were not originated from body cell of anther wall tissue, but from reduced microspores, 5) Since already reported many herbaceous haploid plants were induced from the callus which were originated from reduced microspores, I conclude that the anther of woody plant which induced the haploid callus also will be cultured haploid plant.

  • PDF

Productivity of Lespedeza Species by the Number of Cutting Times (싸리류(類)의 예확회수별(刈穫回數別) 생산성(生産性)에 관(關)한 연구(硏究))

  • Han, Young Chang
    • Journal of Korean Society of Forest Science
    • /
    • v.23 no.1
    • /
    • pp.17-27
    • /
    • 1974
  • In order to investigate the variation of nutritive value, fertilizer value, productivity and growth performance by the number of cutting times in Lespedeza bicolor, Lespedeza maximowiczii and Lespedeza japonica var. intermedia, the plots of one, two and four cutting times in a year had been made through 1972 to 1973. The results are summarized as follows. 1. Lespedeza bicolor, Lespedeza maximowiczii and Lespedeza japonicavar. var. intermedia showed increase of growth and productivity in two plots excluding the plots of four time cuttings. 2. Significant differences at 1% level were shown among the species and the number of cutting times in total grass yield. Lespedeza bicolor showed the greatest production, and followed by Lespedeza maximowiczii and Lespedeza japonica var. intermedia. The plots of one cutting time a year produced more dry weight than that of two and four cutting times. The production in plots of fourth cutting showed less growth and yield. 3. The ratios of dry weight to fresh weight and of leaf weight to stem weight were decreased when the number of cutting times increased in Lespedeza bicolor, Lespedeza maximowiczii and Lespedeza japonica var. intermedia. 4. Crude protein was decreased, though crude fiber content was increased when the grasses were growing more and more. Conent of crude fat showed great variation by the number of cutting times and cutting period seoson. 5. Early cut tings of Lespedeza showed higer fertizer value than late cuttings in all the species. 6. It is suggested that two and three time cutting through a year in Lespedeza bicolor and Lespedeza japonica var. intermedia having high nutritive and fertilizer value is good when using the Lespedeza species as a fodder or manuers, and one time cutting a year will be good when using the Lespedeza species as a fuel.

  • PDF

Drying of Rough Rice by Solar Collectors (태양(太陽) 열(熱 )집열기(集熱機)를 이용(利用)한 벼의 건조(乾燥)에 관(關)한 연구(硏究))

  • Chang, Kyu-Seob;Kim, Man-Soo;Kim, Dong-Man
    • Korean Journal of Food Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.264-272
    • /
    • 1979
  • The flat-plate and tubular soar collectors were designed and constructed for drying the rough rice, and the performance of the collectors and drying effect were investigated when rough rice was packed in grain bin connected to collectors. Average-monthly radiation on a horizontal surface based on bright sunshine in Daejeon area during 1978 was the highest as $16,814\;KJ/m^2{\cdot}day$ in May and the lowest as $4,254\;KJ/m^2{\cdot}day$ in December, and significane was not recognized between the calculated and recorded values. The thermal effciency of collectors were increased as radiation increased during drying period and the average thermal effciency of flat-plate and tubular collectors in 11 to 12 o'clock a.m were 28.12 and 16.75%, respectively. The average inlet temperature of grain bin at 12 o'clock was shown as 20.02 at control 40.5 at grain bin connected to tubular collector and $55.1^{\circ}C$ at grain bin connected to flat-plate collector. In 25 cm rough rice depth in grain bin, tim taken for drying from initial moisture content at 27.4 to decrease upto 17.0% (14.5 % on wet basis) were 32 in control, 18 in grain bin connected to tubular collector and 11 hrs to flat-plate collector, and grain depth influenced drying rate remarkably. In the view point of drying characteristics, drying pattern showed initially falling-rate to constant-rate period finally.

  • PDF

Study on the Indoor-Outdoor $NO_2$ Levels and Related Factors in Urban Apartments (도시아파트의 실내외 $NO_2$ 농도와 관련요인에 관한 연구)

  • Suh, Byung-Seong;Kim, Sung-Hwan;Kim, In-Shik;Hur, Yun-Young;Do, Sou-Young;Kim, Jung-Man;Kim, Joon-Youn
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.3 s.58
    • /
    • pp.609-622
    • /
    • 1997
  • Nitrogen dioxide $(NO_2)$ has been regarded as one of the main elements among air pollutants, and we measured $NO_2$ levels of near gas range, kitchen, living room and outdoor on 489 apartments in Pusan area. $NO_2$ were sampled by using Palmes tubes (diffusion tube sampler) during August 16-25, 1995 (summer) and January 15-29, 1996 (winter), respectively. Authors wanted to know comparison of $NO_2$ levels in summer and winter, $NO_2$ levels categorized by variables, and variables affected to $NO_2$ levels. According to this study, we conducted to establish the degree of indoor-outdoor air pollution of urban apartments in Korea and methods to reduce indoor air pollution. The results of this study were summarized as follows: 1) Mean $NO_2$ levels of near gas range, kitchen, living room, and outdoor were $25.9{\pm}10.0ppb,\;23.3{\pm}8.0ppb,\;19.9{\pm}6.1ppb,\;and\;19.0{\pm}6.0ppb$ in summer, and $34.5{\pm}16.8ppb,\;28.2{\pm}13.4ppb,\;25.3{\pm}12.5ppb,\;21.8{\pm}9.8ppb$ in winter, respectively. 2) Mean $NO_2$ levels according to the floor levels were not significantly different in summer, and in winter, $NO_2$ levels were decreased as the floor levels were increasing, but those were increased above 16th floor. 3) Variables showing significant correlation(p<0.05) with $NO_2$ levels were as follows; Summer: floor level, family size, number of family during a meal, number using gas range during rice cooking per day, and natural ventilation. Winter: floor level, family size, number of person who have been respiratory disease in a house, number of family during a meal, total number of meals, and number using gas range during rice or side-dish cooking per day. 4) We suggest that the methods of reducing indoor $NO_2$ levels are ventilation during cooking, complete combustion, decreasing number and time of cooking, and substitution of fuels.

  • PDF

A Survey on the Break-down and Repair of the Power Tillers in Korea (동력경운기(動力耕耘機) 이용실태(利用實態) 조사분석(調査分析)(II) -고장(故障) 및 수리(修理)에 관(關)하여-)

  • Hong, Jong Ho;Lee, Chai Shik
    • Journal of Biosystems Engineering
    • /
    • v.6 no.1
    • /
    • pp.28-38
    • /
    • 1981
  • A survey has been conducted to investigate the presents of breaks down and repair of power tiller for efficient use. Eight provinces were covered for this study. The results are summarized as follows. A. Frequency of breaks down. 1) Power tiller was breaken down 9.05 times a year and it represents a break down every 39.1 hours of use. High frequency of breaks down was found from the fuel and ignition system. For only these system, the number of breaks down were 2.02 and it represents 23.3% among total breaks down. It was followed by attachments, cylinder system, and traction device. 2) For the power tiller which was more than six years old, breaks down accured 37.7 hours of use and every 38.6 hours for the power tiller which was purchased in less than 2 years. 3) For the kerosene engine power tiller, breaks down occured every 36.8 hours of use, which is a higher value compared with diesel engine power tiller which break down every 42.8 hours of use. The 8HP kerosene engine power tiller showed higher frequency of break down compared with any other horse power tiller. 4) In October, the lowest frequency of break down was found with the value of once for every 51.5 hours of use, and it was followed by the frequency of break down in June. The more hours of use, the less breaks down was found. E. Repair place 1) 45.3% among total breaks down of power tiller was repaired by the owner, and 54.7% was repaired at repair shop. More power tiller were repaired at repair shop than by owner of power tiller. 2) The older the power tiller is, the higher percentage of repairing at the repair shop was found compared with the repairing by the owner. 3) Higher percentage of repairing by the owner was found for the diesel engine power tiller compared with the kerosene engine power tiller. It was 10 HP power tiller for the kerosene power tiller and 8 HP for the diesel engine power tiller. 4) 66.7% among total breaks down of steering device was repaired by the owner. It was the highest value compared with the percentage of repairing of any other parts of power tiller. The lowest percentage of repairing by owner was found for the attachments to the power tiller with the value of 26.5%. C. Cause of break down 1) Among the total breaks down of power tiller, 57.2% is caused by the old parts of power tiller with the value of 5.18 times break down a year and 34.7% was caused by the poor maintenance and over loading. 2) For the power tiller which was purchased in less than two years, more breaks down were caused by poor maintenance in comparison to the old parts of power tiller. 3) For the both 8-10 HP kerosene and diesel engine power tiller, the aspects of breaks down was almost the same. But for the 5 HP power tiller, more breaks down was caused by over loading in comparison to the old parts of power tiller. 4) For the cylinder system and traction device, most of the breaks down was caused by the old parts and for the fuel and ignition system, breaks down was caused mainly by the poor maintenance. D. Repair Cost 1) For each power tiller, repair cost was 34,509 won a year and it was 97 won for one hoar operation. 2) Repair cost of kerosene engine power tiller was 40,697 won a year, and it use 28,320 won for a diesel engine power tiller. 3) Average repair cost for one hour operation of kerosene engine power tiller was 103 won, and 86 won for a diesel engine power tiller. No differences were found between the horse power of engines. 4) Annual repair cost of cylinder system was 13,036 won which is the highest one compared with the repair cost of any other parts 362 won a year was required to repair the steering device, and it was the least among repair cost of parts. 5) Average cost for repairing the power tiller one time was 3,183 won. It was 10,598 won for a cylinder system and 1,006 won for a steering device of power tiller. E. Time requirement for repairing by owner. 1) Average time requirements for repairing the break down of a power tiller by owner himself was 8.36 hours, power tiller could not be used for operation for 93.58 hours a year due to the break down. 2) 21.3 hours were required for repairing by owner himself the break down of a power tiller which was more than 6 years old. This value is the highest one compared with the repairing time of power tiller which were purchased in different years. Due to the break down of the power tiller, it could not be used for operation annually 127.13 hours. 3) 10.66 hours were required for repairing by the owner himself a break down of a diesel engine power tiller and 6.48 hours for kerosene engine power tiller could not be used annually 99.14 hours for operation due to the break down and it was 88.67 hour for the diesel engine power tiller. 4) For both diesel and kerosene engine power tiller 8 HP power tiller required the least time for repairing by owner himself a break down compared with any other horse power tiller. It was 2.78 hours for kerosene engine power tiller and 8.25 hours fur diesel engine power tiller. 5) For the cylinder system of power tiller 32.02 hours were required for repairing a break down by the owner himself. Power tiller could not be used 39.30 hours a year due to the break down of the cylinder system.

  • PDF