• Title/Summary/Keyword: 연동인터페이스

Search Result 504, Processing Time 0.029 seconds

Development of remote monitoring system based on wire and wireless internet Environment (유.무선 인터넷 환경에 연동한 원격 감시시스템 개발)

  • 박상국
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.557-560
    • /
    • 2004
  • In this paper, wireless internet services are combined with conventional wire internet service system. These system support that instrument manager can be access his instrument by use personal mobile devices and instrument manager can be take emergency action by use mobile devices. for this, error signal of local instruments are transmitted to the serial port of local server through Rf wireless communication channel. Also, The image of local instruments are transmitted to the web monitoring screen of main server. Network Camera System Supports remote monitoring functions. The interfacing of nam server with external user are possible through the mobile devices.

  • PDF

Design and Implementation of the SMIL Authoring Tool (SMIL(Synchronized Multimedia Integration Language) 전용 저작도구의 설계 및 구현)

  • Shin, Dong-Kyoo;Shin, Dong-Il;Kim, Se-Young
    • The KIPS Transactions:PartB
    • /
    • v.10B no.1
    • /
    • pp.103-110
    • /
    • 2003
  • SMIL is a declarative markup language based on XML, which enables users to make effective multimedia presentations on the web by synchronizing media objects. In this paper, we design and implement a SMIL authoring tool which support Intuitive creation of web multimedia documents and diverse practical use of created information. Besides, creation, management and authoring module of SMIL document, it offers template interface depending on network bandwidth selection for general users to create multimedia presentation a convenient way. In addition, we implement SMIL document management facility for a large number of users, by connecting SMIL contents database sever.

An Architecture Supporting Emergency Service in WiBro Mobile VoIP Networks (와이브로 모바일 VoIP에서 긴급 서비스 지원을 위한 구조)

  • Lee, Kye-Sang;Lee, Il-Jin;Kang, Sin-Gak
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.414-416
    • /
    • 2010
  • WiBro network technologies developed mainly by Korea are one of very promising 4G technologies. WiBro has been standardized as international standard called Mobile WiMAX, and has been deployed in many countries. Emergency Services are infrastructural servicesa and very essential to induce subscribers from other types of networks. This paper propose a network architecture for supporting emergency services for mobile VoIP services in WiBro networks. The proposed architecture is based on WMF's architecture for internationa compatibilities, and reflects national considerations on interfacing PSAP for domestic compatibilities.

  • PDF

Design of Dynamic Service Management Model for Context-Aware Service Applications (상황인식 서비스 응용을 위한 동적 서비스 관리 모델 설계)

  • Jung Heon-Man;Lee Jung-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.4 s.42
    • /
    • pp.165-174
    • /
    • 2006
  • As context aware service supports a process of context acquisition and reasoning, there are many studies to facilitate the implementation of context aware service. However, these studies have not supported efficiently a user or service mobility that should be supported necessarily in ubiquitous computing environment. Therefore, this study proposes a dynamic context aware service model which supports a dynamic management of context information, service retrieval and composition for interactions between services, and service mobility. Then we design a middleware based on this model and implement the middleware. As the middleware is implemented on the OSGi framework. it can have an interoperability between the devices such as computers, PDA, home appliances, and sensors, because of using the standard interface technologies like UPnP. Jini and so on.

  • PDF

MobileGen: a Script Generator for Mobile Applications (MobileGen: 모바일 응용을 위한 스크립트 생성기)

  • Kim, Soo-Yi;Kim, Hyun-Jung;Lee, Hyun-Jin;Jung, Hee-Jin;Eum, Doo-Hun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2007.11a
    • /
    • pp.233-236
    • /
    • 2007
  • 무선 인터넷 기술의 발전과 함께 이용자 수가 증가하면서 모바일 데이터베이스 응용 프로그램의 수요가 급증하고 있다. 그러나 모바일 데이터베이스 응용에 필요한 사용자 인터페이스와 질의 처리 코드는 대부분 수작업으로 작성되기 때문에 생산성이 낮고 버전 관리에도 많은 시간과 노력이 필요하다.[1] 본 논문에서는 모바일 데이터베이스 응용을 위한 스크립트 생성 도구인 MobileGen을 소개한다. MobileGen은 덕성여자대학교 도서관에서 사용하고 있는 DISCOVER와 같은 실용 데이터베이스들을 구성파일 생성단계, 스크립트 생성단계를 거쳐 응용 데이터베이스 내의 테이블 당 5개의 모바일 스크립트들(Search, Select, Edit, Information, Action)을 생성한다. 생성된 스크립트들은 데이터베이스 연동 및 질의 처리 코드를 포함하고 Action 스크립트를 제외한 나머지 스크립트들은 간단한 폼 형태의 카드 또는 연계된 카드들의 데크들을 생성한다. 따라서 MobileGen은 모바일 데이터베이스 응용의 생산성을 향상시키고 스크립트의 원형인 템플릿을 기반으로 하기 때문에 MobileGen 자체와 생성된 응용의 유지 및 보수를 용이하게 한다. 또한, MobileGen은 상용 생성기들에 비해 관심의 대상인 엔티티 외에 이 엔티티와 직 간접적으로 연관된 모든 엔티티들에 대한 정보를 한 데크에 제공한다.

  • PDF

Techniques of Airbreathing Propulsion System Integration Using Small Gas Turbine Engine for Subsonic Cruise Missiles (소형 가스터빈 엔진의 유도탄 체계통합 기술)

  • Jang, Jongyoun;Kim, Joon;Jung, Jaewon;Lim, Jinshik
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.3
    • /
    • pp.81-88
    • /
    • 2021
  • An airbreathing propulsion system of a subsonic cruise missile is mainly composed of a small gas turbine engine, air intake and vehicle's fuel tank. The propulsion system integration work started from engine acceptance test is finally closed by ground functional test of the missile's propulsion section, after some modifications of engine's sub-components, development of engine-related onboard systems, interface analyses, and tests. The whole process and stepwise technologies of this system integration work are described herein.

An Establishment of Functional Test Facility for ICT-Convergence Equipment of Vessel : Focused on Maritime Digital Interfaces and Main Navigation Communication Systems (선박 ICT융합 장비 기능시험 시설 구축 연구 : 선박 디지털 인터페이스 및 주요 항해통신장비를 중심으로)

  • Hwang, Hun-Gyu;Kim, Bae-Sung;Woo, Snag-Min;Woo, Yun-Tae;Shin, Il-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.5
    • /
    • pp.754-763
    • /
    • 2018
  • The maritime ICT-convergence equipment are essentially required to a type approval (TA) certification that needs environmental and functional tests, to install in vessel. The environmental test is to experiment the possession for required durabilities of the target device in maritime environment, and the functional test is to check the required functions of target equipment based on international standard. In Korea, the environmental testing facilities amount to 227 sites, but there is no functional testing facility. Because of this, we establish a function test facility for the maritime ICT-equipment. In this paper, we analyze and design the functional testing requirement and required interlocking simulators for digital interfaces and navigation communication equipment. We propose the 2-steps of functional testing procedures, which are single test and integration test, to improve the reliability of testing result. The single test is to examine own functions of the target device, and the integration test is to check harmonized operation with other navigation and communication devices.

Design and Implementation of Ganga Plugins for Grid Interoperability (그리드 상호 운용을 위한 Ganga 플러그인 설계 및 구현)

  • Kim, Han-Gi;Hwang, Soon-Wook;Lee, Yoon-Ki;Kim, Eun-Sung;Yeom, Heon-Y.
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.12
    • /
    • pp.881-890
    • /
    • 2009
  • To solve big problem in high energy physics or bioinformatics, it needs a large number of computing resources. But it hard to be provided by one grid environment. While user can submit each job by using it's own user interface in each grid environment, it may need many cost and efforts to manage several hundred jobs conserved in each grid environment separately. In this paper, to solve this problem we develop Ganga's Gridway backend and InterGrid backend. Therefore as we provide the same grid user interface between different grid environments. We developed a Gridway backend module that provide users with access to globus-based grid resources as well. We have also developed an InterGrid backend that allows users to submit jobs that have access to both glite-based resources and globus-based resources. In order to demonstrate the practicality of the new backend plugin modules, we have integrated the AutoDock application used by WISDOM project into Ganga as a new built-in application plugin for Ganga. And we preformed interoperability experiment between PRAGMA grid based on Globus and EGEE grid based on gLite.

LAN Based MFD Interface for Integrated Operation of Radio Facilities using Fishery Vessel (어선용 무선설비의 통합운용을 위한 LAN 기반 MFD 인터페이스)

  • In-ung Ju;In-suk Kang;Jeong-yeon Kim;Seong-Real Lee;Jo-cheon Choi
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.6
    • /
    • pp.496-503
    • /
    • 2022
  • In the reality that the fishing population is decreasing and the single-man fishing vessels is increasing, mandatory equipment for navigation and radio equipments for the safety of fishing boats has continued to be added. Therefore, many equipment such as navigation, communication and fishing are installed in the narrow steering room, so it is very confusing and a number of monitors are placed in the front, which is a factor that degrades the function of maritime observation. To solve this problem, we studied an interface that integrates and operates to major radio facilities such as very high frequency-digital selective calling equipment (VHF-DSC), automatic identification system (AIS) and fishing boat location transmission device (V-pass) into one multi function display (MFD) based on LAN. In addition, IEC61162-450 UDP packets and IEC61162 sentence were applied to exchange data through link between MFD and radio equipments, and additional messages needed for each equipment and function were defined. The integrated MFD monitor is easily operated by the menu method, and the performance of the interface was evaluated by checking the distress and emergency communication functions related to maritime safety and the message transmission status by equipment.

A Benchmark of Micro Parallel Computing Technology for Real-time Control in Smart Farm (MPICH vs OpenMP) (제목을스마트 시설환경 실시간 제어를 위한 마이크로 병렬 컴퓨팅 기술 분석)

  • Min, Jae-Ki;Lee, DongHoon
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.161-161
    • /
    • 2017
  • 스마트 시설환경의 제어 요소는 난방기, 창 개폐, 수분/양액 밸브 개폐, 환풍기, 제습기 등 직접적으로 시설환경의 조절에 관여하는 인자와 정보 교환을 위한 통신, 사용자 인터페이스 등 간접적으로 제어에 관련된 요소들이 복합적으로 존재한다. PID 제어와 같이 하는 수학적 논리를 바탕으로 한 제어와 전문 관리자의 지식을 기반으로 한 비선형 학습 모델에 의한 제어 등이 공존할 수 있다. 이러한 다양한 요소들을 복합적으로 연동시키기 위해선 기존의 시퀀스 기반 제어 방식에는 한계가 있을 수 있다. 관행의 방식과 같이 시계열 상에서 획득한 충분한 데이터를 이용하여 제어의 양과 시점을 결정하는 방식은 예외 상황에 충분히 대처하기 어려운 단점이 있을 수 있다. 이러한 예외 상황은 자연적인 조건의 변화에 따라 불가피하게 발생하는 경우와 시스템의 오류에 기인하는 경우로 나뉠 수 있다. 본 연구에서는 실시간으로 변하는 시설환경 내의 다양한 환경요소를 실시간으로 분석하고 상응하는 제어를 수행하여 수학적이며 예측 가능한 논리에 의해 준비된 제어시스템을 보완할 방법을 연구하였다. 과거의 고성능 컴퓨팅(HPC; High Performance Computing)은 다수의 컴퓨터를 고속 네트워크로 연동하여 집적적으로 연산능력을 향상시킨 기술로 비용과 규모의 측면에서 많은 투자를 필요로 하는 첨단 고급 기술이었다. 핸드폰과 모바일 장비의 발달로 인해 소형 마이크로프로세서가 발달하여 근래 2 Ghz의 클럭 속도에 이르는 어플리케이션 프로세서(AP: Application Processor)가 등장하기도 하였다. 상대적으로 낮은 성능에도 불구하고 저전력 소모와 플랫폼의 소형화를 장점으로 한 AP를 시설환경의 실시간 제어에 응용하기 위한 방안을 연구하였다. CPU의 클럭, 메모리의 양, 코어의 수량을 다음과 같이 달리한 3가지 시스템을 비교하여 AP를 이용한 마이크로 클러스터링 기술의 성능을 비교하였다.1) 1.5 Ghz, 8 Processors, 32 Cores, 1GByte/Processor, 32Bit Linux(ARMv71). 2) 2.0 Ghz, 4 Processors, 32 Cores, 2GByte/Processor, 32Bit Linux(ARMv71). 3) 1.5 Ghz, 8 Processors, 32 Cores, 2GByte/Processor, 64Bit Linux(Arch64). 병렬 컴퓨팅을 위한 개발 라이브러리로 MPICH(www.mpich.org)와 Open-MP(www.openmp.org)를 이용하였다. 2,500,000,000에 이르는 정수 중 소수를 구하는 연산에 소요된 시간은 1)17초, 2)13초, 3)3초 이었으며, $12800{\times}12800$ 크기의 행렬에 대한 2차원 FFT 연산 소요시간은 각각 1)10초, 2)8초, 3)2초 이었다. 3번 경우는 클럭속도가 3Gh에 이르는 상용 데스크탑의 연산 속도보다 빠르다고 평가할 수 있다. 라이브러리의 따른 결과는 근사적으로 동일하였다. 선행 연구에서 획득한 3차원 계측 데이터를 1초 단위로 3차원 선형 보간법을 수행한 경우 코어의 수를 4개 이하로 한 경우 근소한 차이로 동일한 결과를 보였으나, 코어의 수를 8개 이상으로 한 경우 앞선 결과와 유사한 경향을 보였다. 현장 보급 가능성, 구축비용 및 전력 소모 등을 종합적으로 고려한 AP 활용 마이크로 클러스터링 기술을 지속적으로 연구할 것이다.

  • PDF