Risk Analysis According to the Installation of Fire Doors on Direct Stairs in the Event of a Fire in an Old Apartment (노후 아파트 화재 시 직통계단의 방화문 설치 여부에 따른 위험성 분석)

  • Lee, Sang Im;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.869-878
    • /
    • 2021
  • This study is a study on 11-story apartments that increase the event of fires in old apartments where building-related laws and regulations are not retroactively applied. As a result of analyzing the risk of installing fire doors in Improvement Scenario 2-4, assuming that fire doors are installed as basic scenario 1 in the existing situation where fire doors are not installed at the entrance of direct stairs. In basic scenario 1, the visible distance to the entrance of the direct staircase due to the spread of smoke was 260 seconds. Improvement scenarios 3 to 4 with fire doors installed open 300 seconds after the fire was recognized, and when the fire doors were installed at the entrance of the direct stairs, the visibility to the entrance of the statistics team was less than 600 seconds. In this case, the visibility was 600 seconds at the time of installation of the fire door, and scenarios 3 to 4 increased 56.6% compared to scenario 1, lowering the risk of evacuation by more than 50%. In order to eliminate the risk of non-installation of direct statistical groups that increase the risk of smoke spread, building-related laws such as the Fire Fighting Act shall be retroactively applied when installing a direct stairway entrance or balcony folding evacuation system. The improvement caused by the installation of fire doors has numerically proven the necessity of fire doors during evacuation, and the importance of maintaining fire doors can be grasped.

Separation Processes of Biologically Produced 1,3-Propanediol (1,3-프로판디올의 생물학적 생산을 위한 분리공정)

  • Hong, Yeon-Ki
    • Korean Chemical Engineering Research
    • /
    • v.50 no.5
    • /
    • pp.759-765
    • /
    • 2012
  • As the biodiesel production is increasing rapidly, the crude glycerol, which is principal by-product of biodiesel production, has also been generated in a large amount. Many research studies on value-added utilization of glycerol are under investigation. 1,3-Propandiol is a promising chemical which can be produced from fermentation of glycerol because the application of 1,3-propanediol is mainly in the production of bio-PTT (Poly(trimethylene terephthalate). However, the cost of downstream processes in the biological production of 1,3-propanediol can make a high portion in the total production cost. This review summarizes the present state of separation processes in each step studied for the removal of impurities and the recovery of 1,3-propanediol from its fermentation broth. Furthermore, ATPE (Aqueous Two Phases Extraction) process is suggested as an attractive alternative for the primary separation process of 1,3-propanediol because ATPE is convenient for the simultaneous removal of microbial cells and impurities such as salts of organic acids and the separation of 1,3-propanediol from fermentation broth.

Carbon Dioxide Absorption in a Packed Column Using Guanidine-based Superbase Solution (구아니딘계 초염기 흡수제에 의한 충진탑에서의 이산화탄소 포집 특성)

  • Choi, Young Min;Hong, Yeon Ki;You, Jong Kyun
    • Korean Chemical Engineering Research
    • /
    • v.54 no.5
    • /
    • pp.648-652
    • /
    • 2016
  • The study of $CO_2$ absorption in a packed column by 1,1,3,3-tetramethylguanidine (TMG) dissolved in ethylene glycol is presented. Absorption column of inner diameter 1 in and 0.6 m length was filled with Protruded-packing $0.16in{\times}0.16in$. We investigated the effect of operating conditions on overall mass transfer coefficients as well as on $CO_2$ removal efficiency. The loading values reached at about $1.0mol_{CO2}/mol_{TMG}$. In case of absorbent with lean $CO_2$ loading, the overall mass transfer coefficient was proportional to the concentration of TMG. However, in the range of more than ${\alpha}=0.5molCO_2/molTMG$, the overall mass transfer coefficients decreased with the concentration of TMG. It is due to the increasing of mass transfer resistance in liquid phase as increasing of viscosity at higher loading values.

Studies on the body - retaining rate of smoking-related carcinogens using some important volatile organic compounds (VOC) (흡연시 발암성 물질의 체내 잔존율에 대한 연구 - 주요 휘발성 유기화합물을 중심으로)

  • Kim, K.H.;Choi, Y.J.;Hong, Y.J.;Yang, H.S.;Lee, J.H.;Lee, Y.K.
    • Analytical Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.410-415
    • /
    • 2004
  • In order to learn the emission characteristics of hazardous pollutants associated with environmental tobacco smoking (ETS), we measured the concentrations of major aromatic VOC and carbonyl compounds released from ETS. By acquiring the different smoke types of ETS, we were able to determine that the concentrations of those species range from ppb (normal exhaled air of smoker prior to smoking) to ppm levels (direct release of ETS without filter). Using these measurement data, we also evaluated the body-retaining rate of these compounds as the result of ETS. The results of our analysis indicated that predominant portion of them (e.g., > 99%) are retained as the result of cigarette smoking. To learn more about the potential impact of ETS, more extensive study may be required to assess the gross picture of pollutant deposition inside respiratory intake and their health-effects.

The Design and Implementation of Restructuring Tool with Logical Analysis of Object-Oriented Architecture and Design Information Recovery (설계 정보 복구와 객체 지향 구조의 논리적 분석을 통한 재구성 툴 설계 및 구현)

  • Kim, Haeng-Gon;Choe, Ha-Jeong;Byeon, Sang-Yong;Jeong, Yeon-Gi
    • The Transactions of the Korea Information Processing Society
    • /
    • v.3 no.7
    • /
    • pp.1739-1752
    • /
    • 1996
  • Software reengineering involves improving the software maintenance process and improving existing systems by applying new technologies and software tools. Software reengineering can help us understand existing systems and discover software components that are common across systems. In the paper, we discuss the program analysis and environment to assist reengineering. Program analysis takesan existing program as input and generates information about structured part and object-oriented part. It is used to restructure the information by extracting code through reengineering methodology. These restructuring informations with object-oriented archilccture are mapping prolog form to query by using direct reation and summary relation.

  • PDF

A Study on Characteristics of Roof 'Jucsim' Structure Combustion Real Scale Fire Test on Wooden Structure Heritage Building (목조 건축 문화재 적심부 실물화재 실험을 통한 연소 특성 연구)

  • Roh, Sam-Kew;Ham, Eun-Gu
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.95-102
    • /
    • 2010
  • The combustion characteristics of roof 'Jucsim' structure was analysed using real scale fire test on wooden structure heritage building. the fire test model was made to consider roof timberling internal structure for a Sunglemun. Structure of test body layed lime, soil, 'Jucsin' and ceiling board excepting roof tile to find heat propagation process by setting thermocouples. The first test to find fire growth and heat propagation process in the part of ceiling. The second test organized to find the efficiency of fire proof paint between ceiling board and inside of Jucsim structure. The third test try to get the performance level of fire proof fabric with the same manner. The result showed from the test proof the heavy smoke exposure with limited effect of fire proof paint however, reliable fire resistance effect showed in case of fire proof fabric.

Selective Removal of Acetic Acid for the Effective Production of Succinic Acid using the Various Amino Extractants and Solvents (효율적 숙신산 생산을 위한 다양한 아민추출제와 용매를 이용한 아세트산의 선택적 추출제거)

  • Huh Yun Suk;Hong Yeon Ki;Jun Young-Si;Hong Won Hi
    • KSBB Journal
    • /
    • v.20 no.3
    • /
    • pp.238-243
    • /
    • 2005
  • Succinic acid has recently been drawing much interest as a raw material for biodegradable polymer. In this study acetic acid was removed by reactive extraction with various amines dissolved in various diluents. Distribution coefficients were determined as the kind of amines, diluents, and pHs of continuous phase. The extraction capacity increased with the polarity of diluent and the decrease of pH from the artificial binary solution. Based on the different extractability for succinic acid and acetic acid from the artificial binary solution, the removal of acetic acid from fermentation broth was investigated using various amines and diluents. In addition, the extractability and selectivity of CLA for succinic acid and acetic acid from fermentation broth were higher than that of straight solvent extraction.

Analysis of Fire Patterns of Flammable Liquids for Oil Flow Tests of Compartment Fires with Reduced Simulation (축소 모의된 구획 화재의 흘림 실험에 대한 인화성 액체의 화재 패턴 해석)

  • Joe, Hi-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.43-48
    • /
    • 2014
  • The purpose of this study is to analyze the flame propagation speed, radiation range, diffusion pattern and combustion completion time of a fire by filling a divided space with single combustible substance. It was found that the flame propagation speed was the fastest (0.2 s) for kerosene and the lowest (82.1 s) for alcohol. In the case of paint thinner, it took 19.0 s for the flame to reach its peak at the fastest speed after ignition while in the case of alcohol, it took 138.6 s for the flame to reach its peak at the lowest speed. In the case of the combustion of 200 ml of flammable liquids, the combustion completion time was 79.9 s for paint thinner, which is the shortest, 135 s for gasoline, 170 s for kerosene, 231.4 s for diesel and 337.0 s for alcohol. In addition, when flammable liquids are combusted, the lower part of the flame is governed by laminar flow pattern and the upper part of the flame showed turbulence pattern. In the case of a test performed for bean oil, it could be seen that if the fire source was removed, the flame was automatically extinguished without further combustion and that white smoke was generated due to incomplete combustion.

A study on the location of fire fighting appliances in cargo ships (화물선 소화설비 비치에 대한 연구)

  • Ha, Weon-Jae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.852-858
    • /
    • 2016
  • To safeguard the accommodation spaces on cargo ships from fire, structural fire protection provisions introduced by SOLAS and these measures retard the propagation of flames and smoke. SOLAS also specifies provisions for fire fighting drills. These provisions are a combination of regulations regarding structure and equipment and those dealing with the human element for the fire protection and effective responses in the event of fire. Requirements related to the human element play a supporting role to the requirements for structure and equipment because the present accommodation structure and equipment are insufficient for extinguishing a fire, therefore, fire-extinguishing activity performed by crew members is essential. To reduce human error and ensure effective fire fighting, it is necessary to install a fire-fighting system and improve the fire fighting process. The fundamental concept of fire fighting exercises is to commence fire fighting before the fire grows too big to extinguish. It is essential to relocate the storage place of fire fighting equipment to expedite the fire-fighting exercise. This study was carried out to reduce human risk for this purpose, the fire control station was relocated to a site that could be accessed from the open deck. Further, two sets of a fire fighter's outfit were stored at the same site. This relocation eliminated the risk of the crew reentering to operate the fire fighting system in the fire control station and allowed the crew to pick up the fire fighters' outfits quickly in the event of a fire. In addition, it was proposed that the IIC method be made mandatory. This method is combination of automatic fire detection system and sprinkler system which can reduce the risk of the fire fighting exercises for the crew and to suppress fire in the initial stage. This study was carried out to provide a foundation to the possible amendment of the relevant SOLAS regulations and national legislation.