• Title/Summary/Keyword: 연기검출

Search Result 84, Processing Time 0.03 seconds

Drift and Distribution Properties of Pesticide Spray Solution Applied Aerially by manned-Helicopter (헬기를 이용한 항공살포 농약의 비산 및 분포 특성)

  • Jin, Yong-Duk;Lee, Hee-Dong;Park, Yeon-Ki;Kim, Jin-Bae;Kwon, Oh-Kyung
    • The Korean Journal of Pesticide Science
    • /
    • v.12 no.4
    • /
    • pp.351-356
    • /
    • 2008
  • This study was carried out to assess adoptability and environment impacts of ultra low volume (ULV) pesticide spray solutions aerially sprayed by manned-helicopter. Uniformity of the deposited amount in paddy fields was uneven, showing $3.1{\sim}4.7$ times differences among surveyed sites. Drifting distance of aerially sprayed droplets from the target area was within 30 m in the wind direction and 20 m in the opposite direction. Most of the aerially sprayed pesticides were deposited in/on rice plants, while those in submerged paddy water and soil were relatively small. The degradation rate of the deposited pesticides was in the decreasing order of rice plants, paddy water and soil. Soil residues of pesticides in the aerially sprayed rice paddy fields after harvest ranged from non-detected to 0.201 mg/kg. However, no pesticides were detected in brown rice and rice straw. No phytotoxic symtoms were observed in rice plants and nearby non-target crops by the sprayed pesticides.

Quantitative Analysis of Residual 24 Organochlorine POPs in Sundried Salts (천일염 중 유기염소계 잔류성 유기오염물질(POPs) 잔류분석)

  • Choi, Geun-Hyoung;Park, Mi-Ran;Park, Jong-Min;Hong, Su-Myeong;Kwon, Oh-Kyoung;Park, Yun-Ki;Kim, Jin-Hyo
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.4
    • /
    • pp.502-506
    • /
    • 2011
  • Most countries have the legislation and regulation for POPs control in food. In here, we studied the quantitative analysis of 24 organochlorine POPs (${\alpha}$-HCH 1, ${\beta}$-HCH 2, ${\gamma}$-HCH 3, ${\delta}$-HCH 4, trans-chlrodane 5, 2,4'-DDE 6, ${\alpha}$-endosulfan 7, cis-chlordane 8, 2,4'-DDD 9, endrin 10, ${\beta}$-endosulfan 11, 2,4'-DDT 12, endosulfan sulfate 13, HCB 14, aldrin 15, trans-nonachlor 16, 4,4'-DDE 17, dieldrin 18, 4,4'-DDD 19, cis-nonachlor 20, 4,4'-DDT 21, heptachlor 22, heptachlor epoxide 23 and mirex 24) with GC-ECD. The retention time of analytes were ranged between 19.18 min and 34.69 min, and their peak intervals were over 0.05 min at least. LOQs were ranged 0.003 ~ 0.033 ng/g, and their recovery rates were showed 60.9 ~ 120.8% on the 0.1 ng/g concentration of 24 organochlorine POPs. All tested 30 sundried salts were collected on Korean retailed market, and any analyte was not found in all the samples on LOQ levels.

Analysis of Benzo[α]pyrene Content in Edible Oils from Korean Market (시중에 유통되는 식용유지 중 benzo[α]pyrene 함량 분석)

  • Nam, Hejung;Seo, Ilwon;Lee, Kyueun;Lee, Songyoung;Shin, Han-Seung
    • Food Engineering Progress
    • /
    • v.13 no.3
    • /
    • pp.211-215
    • /
    • 2009
  • Concentrations of benzo[$\alpha$]pyrene in edible oils from Korean market were evaluated by high performance liquid chromatography. Benzo[$\alpha$]pyrene known of the carcinogenic polycyclic aromatic hydrocarbons(PAHs), has been found at variable concentrations in several foods. This is associated with several factors during the process including contaminated raw materials, exposure of environment, and procedure of process or cooking. The levels of benzo[$\alpha$]pyrene were ranged from 0.5 to 1.4 $\mu$g/kg in virgin olive oil. Benzo[$\alpha$]pyrene contents in refined and virgin olive oil, sesame oil, soybean oil, corn oil, sunflower oil, safflower oil, and processed oil were 0.6-1.0 $\mu$g/kg, 0.9-1.3 $\mu$g/kg, 0.6-3.3 $\mu$g/kg, 0.5-1.1 $\mu$g/kg, 1.2-1.7 $\mu$g/kg, 1.0-2.1 $\mu$g/kg, and 1.0-1.4 $\mu$g/kg, respectively.

S-FDS : a Smart Fire Detection System based on the Integration of Fuzzy Logic and Deep Learning (S-FDS : 퍼지로직과 딥러닝 통합 기반의 스마트 화재감지 시스템)

  • Jang, Jun-Yeong;Lee, Kang-Woon;Kim, Young-Jin;Kim, Won-Tae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.4
    • /
    • pp.50-58
    • /
    • 2017
  • Recently, some methods of converging heterogeneous fire sensor data have been proposed for effective fire detection, but the rule-based methods have low adaptability and accuracy, and the fuzzy inference methods suffer from detection speed and accuracy by lack of consideration for images. In addition, a few image-based deep learning methods were researched, but it was too difficult to rapidly recognize the fire event in absence of cameras or out of scope of a camera in practical situations. In this paper, we propose a novel fire detection system combining a deep learning algorithm based on CNN and fuzzy inference engine based on heterogeneous fire sensor data including temperature, humidity, gas, and smoke density. we show it is possible for the proposed system to rapidly detect fire by utilizing images and to decide fire in a reliable way by utilizing multi-sensor data. Also, we apply distributed computing architecture to fire detection algorithm in order to avoid concentration of computing power on a server and to enhance scalability as a result. Finally, we prove the performance of the system through two experiments by means of NIST's fire dynamics simulator in both cases of an explosively spreading fire and a gradually growing fire.

A case study on the fire victim in the vehicle by GC/MS through derivatization of cyanide with pentafluorobenzyl bromide (PFBBr) (시안화이온의 pentafluorobenzyl bromide (PFBBr)에 의한 유도체화 후 GC/MS 분석에 의한 차량화재 변사체 사인규명에 관한 사례연구)

  • Lee, Joon-Bae;Shon, Sung Kun;Woo, Sang Hee;Park, Se Yeon;Hwang, Jung Ho;Kwon, O-Seong;Kim, Nam Yi;Paeng, Ki Jung
    • Analytical Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.73-78
    • /
    • 2016
  • Hydrogen cyanide (HCN) is an extremely toxic gas frequently produced during the incineration of plastics, such as acrylonitrile-butadiene-styrene (ABS). A victim of a fire who has inhaled smoke could have cyanide in the blood. Therefore, cyanide could be a good marker for a post-mortem examination of a fire as well as carboxyhemoglobine (COHb) test of blood samples. For a particular fire case, a burned body with a suicide note was found inside a burned vehicle. Even though the COHb value is conclusive evidence, measuring the COHb for denatured blood might be difficult due to severe thermal denaturation or the formation of methemoglobin (MetHb). To overcome this difficulty, cyanide could be used as an indicator when investigating the death of a fire victim. In this study, gas chromatography/mass spectrometry (GC/MS) was adopted to measure the levels of cyanide in the blood through derivatization with pentafluorobenzyl bromide (PFBBr) under cation surfactant by scan and SIM mode. The concentration of cyanide in the blood of heart blood and brain of the victim was found to be 0.36 µg/mL and 1.20 µg/mL respectively, which was higher than the average value (0.041 µg/mL) found in the blood of 14 people who smoked.

The Difference of Fish Toxicity by Preparation Methods of Test Solution (시험용액의 조제방법에 따른 어독성 차이)

  • Bae, Chul-Han;Kim, Yeon-Sik;Park, Yeon-Ki;Park, Eun-Hee;Park, Hynn-Ju;Shin, Dong-Chan;Lee, Seung-Yeol;Lee, Suk-Hee;Chung, Chang-Kook
    • The Korean Journal of Pesticide Science
    • /
    • v.14 no.3
    • /
    • pp.219-225
    • /
    • 2010
  • The solubility in water of granular pesticides is not equal because the difference of methods of producing a granular pesticide. This study was conducted to investigate fish acute toxicity of butachlor 5% GR, fipronil 0.4% GR by impregnation and carbosulfan 3% GR, diazinon 0.4% GR by coating, using carp (C. carpio), medaka (O. tatipes) and loach (M. anguillicaudatus). The test solution of each pesticide was prepared by direct addition of granular pesticide and add after grinding granular pesticide to powder in test water, We also investigated $LC_{50}$ and residual concentration until 96 hours. Test results were appeared that the treatment of powder was 1.2~4 time higher than granular and toxicity increased clearly according to elapsed time, And the residual amounts by time were detected much at early time in the powder treatment of butachlor GR and diazinon GR. Conclusively, fish acute toxicity and residual concentration in test solution appeared higher in the powder treatment than treat granular form directly in water. Also, 96 hours toxicity values were stable comparatively and the error is less than 48 hours.

Buffer Zones for Non-Target Organisms by Aerial Pesticide Application Around Rice Paddy (벼 재배지의 항공 방제시 비표적 생물에 대한 안전거리)

  • Park, Yeon-Ki;Jin, Yeoung-Duck;Kim, Byung-Seok;Park, Kyung-Hun;Lee, Jea-Bong;Shin, Jin-Sup;Bae, Chung-Han;Lee, Kyu-Seung
    • The Korean Journal of Pesticide Science
    • /
    • v.11 no.1
    • /
    • pp.32-37
    • /
    • 2007
  • The study was carried out to establish buffer zone for the protection of the non-target organisms by aerial pesticide application. The two pesticide combination of 3-way tank-mixing of three pesticides for aerial application, ferimzone tricyclazole SC + BPMC EC + validamycin-A SL and hexaconzole EC + isoprothiolane EC+phenthoate EC were selected for the simultaneous control of key pests on paddy rice as blast, sheath blight, brown planthopper and moth. Aquatic organisms including killifish and loach in the paddy field and nearby water reservoirs were not affected by aerial application of the pesticides. However, all the water flea were killed, when they were exposed 10 m from the aerially sprayed site, while the water flea exposed in 30 m away from the site were not affected. Honeybees within 50 m in the wind direction and 20 m in the opposite wind direction showed a mortality of $7{\sim}100%$. Residues concentration of the pesticides in paddy water were not detectable level after six days from aerial application. Drifting distance of aerially sprayed droplet from the target area was within 30 m in the wind direction and 20 m in the opposite direction. Consequently, it was the buffer zones in the aerial pesticides application for the protection of the non-target organisms should be at least 50 m for aquatic organisms and 100 m for honeybees.

Development of Rapid Detection Method for Volatilized Formaldehyde from Wood (목재 폼알데하이드 신속검출 공정개발)

  • Kim, Jung-Im;Choi, Geun-Hyoung;Kwon, Oh-Kyung;Hong, Su-Myeong;Park, Yun-Gi;Ok, Yong-Sik;Kim, Jin-Hyo
    • Journal of Applied Biological Chemistry
    • /
    • v.55 no.1
    • /
    • pp.55-59
    • /
    • 2012
  • We designed a new rapid detection method for volatilized formaldehyde from wood. The process was installed with volatilizing and collecting parts in an incubator. For rapid sampling of formaldehyde from wood, we pulverized the wood to sawdust, and used 0.15-2.0 mm particles for the tests. The highest sampling rate (94.8%) was obtained at 40 mL/min flow rate and $100^{\circ}C$. Under the optimized condition, we could collect the volatilized formaldehyde with good recovery rate. The developed method was applied to the monitoring of the formaldehyde from wood, and the measured concentrations were 0.7-4.6 ${\mu}g/g$ from natural wood, 5.9-12.3 ${\mu}g/g$ from preserved wood, and 5.9-211.5 ${\mu}g/g$ from chemical adhesive processed wood. From the results, we identified natural wood sawdust and chemically processed wood (medium density fiberboard, high density fiberboard, particle board) by the formaldehyde contents except preserved wood.

Comparison of Liquid Chromatography-Mass/Mass Spectrometry (MS) and Gas Chromatography-MS for Quantitative Analysis of Indole-3-acetic acid and Indole-3-butyric acid from the Concentrated Liquid Fertilizer (Liquid Chromatography-Mass/Mass Spectrometry (MS)와 Gas Chromatography-MS를 이용한 농축 액상 비료제품 중 Indole-3-acetic acid 및 Indole-3-butyric acid 정량분석능 비교)

  • Kim, Jin Hyo;Park, Jong Min;Choi, Geun-Hyoung;Park, Yun-Ki;Im, Geon-Jae;Kim, Doo-Ho;Kwon, Oh-Kyung
    • Journal of Applied Biological Chemistry
    • /
    • v.56 no.1
    • /
    • pp.53-57
    • /
    • 2013
  • In here, we investigated the quantitative analysis method of indole-3-acetic acid (IAA) and indole-3-butyric acid (IBA) with liquid chromatography-mass/mass spectrometry (LC-MS/MS) or gas chromatography-MS. Two ways of clean-up process were investigated for LC-MS/MS instrumental analysis of IAA, but both a simple dilution and hydrophile-lipophile balance (HLB) solid phase extraction (SPE) were not met the optimal recovery rates for quantitative analysis. On the other hand, the clean-up method for GC-MS was finally optimized through HLB-SPE from 250-folds diluted sample and methylation with trimethylsilyl chloride in methanol for 4 h. The limit of detection for methyl ester of IAA and IBA were both 1.4 mg/L, and recovery rates showed 93-107% from the concentrated liquid fertilizer.

A Study on Replay Experiments and Thermal Analysis for Autoignition Phenomenon of Shredded Waste Tires (폐타이어 분쇄물의 자연발화현상에 대한 재연실험 및 열분석에 관한 연구)

  • Koh, Jae Sun;Jang, Man Joon
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.99-108
    • /
    • 2012
  • These days, spontaneous ignition phenomena by oxidizing heat frequently occur in the circumstances of processing and storing waste tires. Therefore, to examine the phenomena, in this work, this researcher conducted the tests of fires of fragmented waste tires (shredded tire), closely investigated components of the fire residual materials collected in the processing and storing place, and analyzed the temperature of the starting of the ignition, weight loss, and heat of reaction. For the study, this researcher conducted fire tests with fragmented waste tires in the range of 2.5 mm to 15 mm, whose heat could be easily accumulated, and performed heat analysis through DSC and TGA, DTA, DTG, and GC/MS to give scientific probability to the possibility of spontaneous ignition. According to the tests, at the 48-hour storage, rapid increase in temperature ($178^{\circ}C$), Graphite phenomenon, smoking were observed. And the result from the DTA and DTG analysis showed that at $166.15^{\circ}C$, the minimum weight loss occurred. And, the result from the test on the waste tire analysis material 1 (Unburnt) through DSC and TGA analysis revealed that at $180^{\circ}C$ or so, thermal decomposition started. As a result, the starting temperature of ignition was considered to be $160^{\circ}C$ to $180^{\circ}C$. And, at $305^{\circ}C$, 10 % of the initial weight of the material reduced, and at $416.12^{\circ}C$, 50 % of the intial weight of the material decreased. The result from the test on oxidation and self-reaction through GC/MS and DSC analysis presented that oxidized components like 1,3 cyclopentnadiene were detected a lot. But according to the result from the heat analysis test on standard materials and fragmented waste tires, their heat value was lower than the basis value so that self-reaction was not found. Therefore, to prevent spontaneous ignition by oxidizing heat of waste tires, it is necessary to convert the conventional process into Cryogenic Process that has no or few heat accumulation at the time of fragmentation. And the current storing method in which broken and fragmented materials are stored into large burlap bags (500 kg) should be changed to the method in which they are stored into small burlap bags in order to prevent heat accumulation.