The effects of physical factors in SPECT (물리적 요소가 SPECT 영상에 미치는 영향)

  • 손혜경;김희중;나상균;이희경
    • Progress in Medical Physics
    • /
    • v.7 no.1
    • /
    • pp.65-77
    • /
    • 1996
  • Using the 2-D and 3-D Hoffman brain phantom, 3-D Jaszczak phantom and Single Photon Emission Computed Tomography, the effects of data acquisition parameter, attenuation, noise, scatter and reconstruction algorithm on image quantitation as well as image quality were studied. For the data acquisition parameters, the images were acquired by changing the increment angle of rotation and the radius. The less increment angle of rotation resulted in superior image quality. Smaller radius from the center of rotation gave better image quality, since the resolution degraded as increasing the distance from detector to object increased. Using the flood data in Jaszczak phantom, the optimal attenuation coefficients were derived as 0.12cm$\^$-1/ for all collimators. Consequently, the all images were corrected for attenuation using the derived attenuation coefficients. It showed concave line profile without attenuation correction and flat line profile with attenuation correction in flood data obtained with jaszczak phantom. And the attenuation correction improved both image qulity and image quantitation. To study the effects of noise, the images were acquired for 1min, 2min, 5min, 10min, and 20min. The 20min image showed much better noise characteristics than 1min image indicating that increasing the counting time reduces the noise characteristics which follow the Poisson distribution. The images were also acquired using dual-energy windows, one for main photopeak and another one for scatter peak. The images were then compared with and without scatter correction. Scatter correction improved image quality so that the cold sphere and bar pattern in Jaszczak phantom were clearly visualized. Scatter correction was also applied to 3-D Hoffman brain phantom and resulted in better image quality. In conclusion, the SPECT images were significantly affected by the factors of data acquisition parameter, attenuation, noise, scatter, and reconstruction algorithm and these factors must be optimized or corrected to obtain the useful SPECT data in clinical applications.

  • PDF

Computer Assisted EPID Analysis of Breast Intrafractional and Interfractional Positioning Error (유방암 방사선치료에 있어 치료도중 및 분할치료 간 위치오차에 대한 전자포탈영상의 컴퓨터를 이용한 자동 분석)

  • Sohn Jason W.;Mansur David B.;Monroe James I.;Drzymala Robert E.;Jin Ho-Sang;Suh Tae-Suk;Dempsey James F.;Klein Eric E.
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.24-31
    • /
    • 2006
  • Automated analysis software was developed to measure the magnitude of the intrafractional and interfractional errors during breast radiation treatments. Error analysis results are important for determining suitable planning target volumes (PTV) prior to Implementing breast-conserving 3-D conformal radiation treatment (CRT). The electrical portal imaging device (EPID) used for this study was a Portal Vision LC250 liquid-filled ionization detector (fast frame-averaging mode, 1.4 frames per second, 256X256 pixels). Twelve patients were imaged for a minimum of 7 treatment days. During each treatment day, an average of 8 to 9 images per field were acquired (dose rate of 400 MU/minute). We developed automated image analysis software to quantitatively analyze 2,931 images (encompassing 720 measurements). Standard deviations ($\sigma$) of intrafractional (breathing motion) and intefractional (setup uncertainty) errors were calculated. The PTV margin to include the clinical target volume (CTV) with 95% confidence level was calculated as $2\;(1.96\;{\sigma})$. To compensate for intra-fractional error (mainly due to breathing motion) the required PTV margin ranged from 2 mm to 4 mm. However, PTV margins compensating for intefractional error ranged from 7 mm to 31 mm. The total average error observed for 12 patients was 17 mm. The intefractional setup error ranged from 2 to 15 times larger than intrafractional errors associated with breathing motion. Prior to 3-D conformal radiation treatment or IMRT breast treatment, the magnitude of setup errors must be measured and properly incorporated into the PTV. To reduce large PTVs for breast IMRT or 3-D CRT, an image-guided system would be extremely valuable, if not required. EPID systems should incorporate automated analysis software as described in this report to process and take advantage of the large numbers of EPID images available for error analysis which will help Individual clinics arrive at an appropriate PTV for their practice. Such systems can also provide valuable patient monitoring information with minimal effort.

  • PDF

Response for Lead Block Thickness of Parallel Plate Detector using Dielectric Film (유전체필름을 이용한 평행판검출기의 납 차폐물 두께변화에 대한 반응)

  • Kim Yong-Eun;Cho Moon-June;Kim Jun-Sang;Oh Young-Kee;Kim Jhin-Kee;Shin Kyo-Chul;Kim Jeung-Kee;Jeong Dong-Hyeok;Kim Ki-Hwan
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • A parallel plate detector containing PTFE films in FEP film for relative dosimetry was designed to measure the response of detectors to S and 10 MV X-rays from a medical linear accelerator through different thicknesses of lead. The dielectric materials were 100 m thick. The set-up conditions for measurements with this detector were as follows: SSD=100 cm the test detector was at a depth of 5 cm and the reference chamber was at a depth of 10 cm from the phantom surface for 6 and 10 MV X-rays. Lead blocks were designed to cover the irradiated field. They were added to the tray to increase thickness sequentially. We found that the detector response decreased exponentially with the thickness of lead added. The linear attenuation coefficients of the test detector and reference chamber were 0.1414 and 0.541, respectively, for 6 MV X-rays and 0.1358 and 0.5279 for 10 MV X-rays. The test detector response was greater than that of the reference chamber. The response function was calculated from the measured values of the test detector and reference chamber using optimization. These optimized constants for the detector response function were independent of theenergy. As a result of optimizing the response function between detectors, the use of a relative dosimeter was validated, because the response of the test detector was 1% for 6 MV X-rays and 4% for 10 MV X-rays.

  • PDF

HVL Measurement of the Miniature X-Ray Tube Using Diode Detector (다이오드 검출기를 이용한 초소형 X선관(Miniature X-ray Tube)의 반가층 측정)

  • Kim, Ju-Hye;An, So-Hyeon;Oh, Yoon-Jin;Ji, Yoon-Seo;Huh, Jang-Yong;Kang, Chang-Mu;Suh, Hyunsuk;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.279-284
    • /
    • 2012
  • The X ray has been widely used in both diagnosis and treatment. Recently, a miniature X ray tube has been developed for radiotherapy. The miniature X ray tube is directly inserted into the body irradiated, so that X rays can be guided to a target at various incident angles according to collimator geometry and, thus, minimize patient dose. If such features of the miniature X ray tube can be applied to development of X ray imaging as well as radiation treatment, it is expected to open a new chapter in the field of diagnostic X ray. However, the miniature X ray tube requires an added filter and a collimator for diagnostic purpose because it was designed for radiotherapy. Therefore, a collimator and an added filter were manufactured for the miniature X ray tube, and mounted on. In this study, we evaluated beam characteristics of the miniature X ray tube for diagnostic X ray system and accuracy of measuring the HVL. We used the Si PIN Photodiode type Piranha detector (Piranha, RTI, Sweden) and estimated the HVL of the miniature X ray tube with added filter and without added filter. Through an another measurement using Al filter, we evaluated the accuracy of the HVL obtained from a direct measurement using the automatic HVL calculation function provided by the Piranha detector. As a result, the HVL of the miniature X ray tube was increased around 1.9 times with the added filter mounted on. So we demonstrated that the HVL was suitable for diagnostic X ray system. In the case that the added filter was not mounted on, the HVL obtained from use of the automatic HVL calculation function provided by Piranha detector was 50% higher than the HVL estimated using Al filter. Therefore, the HVL automatic measurement from the Piranha detector cannot be used for the HVL calculation. However, when the added filter was mounted on, the HVL automatic measurement value using the Piranha detector was approximately 15% lower than the estimated value using Al filter. It implies that the HVL automatic measurement can be used to estimate the HVL of the miniature X ray tube with the added filter mounted on without a more complicated measurement method using Al filter. It is expected that the automatic HVL measurement provided by the Piranha detector enables to make kV-X ray characterization easier.

Development and Utility Evaluation of Portable Respiration Training Device for Image-guided Stereotactic Body Radiation Therapy (SBRT) (영상유도 체부정위방사선 치료시 호흡동조를 위한 휴대형 호흡연습장치의 개발 및 유용성 평가)

  • Hwang, Seon Bung;Park, Mun Kyu;Park, Seung Woo;Cho, Yu Ra;Lee, Dong Han;Jung, Hai Jo;Ji, Young Hoon;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.264-270
    • /
    • 2014
  • This study developed a portable respiratory training device to improve breathing stability, which is an important element in using the CyberKnife Synchrony respiratory tracking device, one of the typical Stereotactic Radiation Therapy (SRT) devices. It produced an interface for users to be able to select one of two displays, a graph type and a bar type, supported an auditory system that helps them expect next respiration by improving a sense of rhythm of their respiratory period, and provided comfortable respiratory inducement. By targeting 5 applicants and applying individual respiratory period detected through a self-developed program, it acquired signal data of 'guide respiration' that induces breathing through signal data gained from 'free respiration' and an auditory system, and evaluated the usability by comparing deviation average values of respiratory period and respiratory amplitude. It could be identified that respiratory period decreased $55.74{\pm}0.14%$ compared to free respiration, and respiratory amplitude decreased $28.12{\pm}0.10%$ compared to free respiration, which confirmed the consistency and stability of respiratory. SBRT, developed based on these results, using the portable respiratory training device, for liver cancer or lung cancer, is evaluated to be able to help reduce delayed treatment time due to respiratory instability and improve treatment accuracy, and if it could be applied to developing respiratory training applications targeting an android-based portable device in the future, even use convenience and economic efficiency are expected.

MR Imaging Findings of Uterine Cervical Adenocarcinoma (자궁경부 선암종의 자기공명영상 소견)

  • 김종철
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.113-119
    • /
    • 1998
  • Purpose : Because adenocarcinomas of the uterine cervix have lower 5-year survival rate than squamous cell carcinomas due to early lymph node metastasis and local extension, scrutiny of lymph node metastasis and local extension by radiologic examination is necessary in case of clinically diagnosed or suspected adenocarcinomas. The purpose of this study is to evaluate whether there are specific findings of these tumors, compared with squamous cell carcinomas, through the analysis of magnetic resonance (MR) imaging findings. Materials and Methods : Of 21 pathologically proven cervical adenocarcinomas, MR imaging findings of 18 tumors (histologic staging : two Ib, four IIa, two IIb, one IIIa, and one IIIb) were retrospectively analyzed and compared with those of 40 wquamous cell carcinoma in consecutive patients as a control group. T1-wetighted and fast spin echo T2-weighted images were obtained on the axial and sagittal planes, using a 1.5-T MR scanner. The largest diameter, location, signal intensity and degree of contrast enhancement contour, shape and longitudinal extent of the tumor and associated findings on MR image were analyzed. Results : The largest diameters of cervical adenocarcinomas ranged from 0.8 to 4.1 cm(mean, 2.2 cm). Of 18 adenocarcinomas, nine were of endocervical type. All adenocarcinomas were isointense to surrounding cervical stroma on T1-weighted images and hyperintense(homogeneous in ten, inhomogeneous in eight) on fast spin echo T2-weighted images. Adenocarcinomas enhanced on contrast study in all patients (homogeneous in six, inhomogeneous in 12 with hyperintese enhnacing rim in two). Eight adenocarcinomas had smooth contours and ten had irregular ones. The shape of adenocarcinoma was irregular in eight patients, barrel shape in six, papillary/polypod in three, and nodular in one. All adenocarcinomas involved lower half of the uterine cervix and six tumors extended up to the upper half. Pelvic lymph nodes of more than 1.5cm in diameter in two adenocarcinomas pateints and no detectable small pelvic lymph nodes on MR imaging in one patient were pathologically positive. Hydrometra was associated in two adenocarcinomas patients, and hematometra in one patient. Compared with squamous cell carcinomas, more frequent MR findings of endocervical type and barrel shape in cervical adenocarcinomas were statistically significant. Conclusion : Cervical adenocarcinomas had more frequent MR findings of endocervical type and barrel shape, compared with wquamous cell carcinomas. Adenocarcinoma of the uterine cervix may be suspected on MR imaging, when a cervical carcinoma is of barrel shape along the endocervical canal and tends to involve lymth nodes in earlier stages.

  • PDF

Diagnostic Accuracy and Evaluation of Myocardial Viability by Cardiac Magnetic Resonance Imaging in Acute Myocardial Infarction: A Comparison with Thallium-201 Myocardial SPECT (급성심근경색증에서의 심장자기공명영상술의 진단 정확도와 심근 생존력 평가: TI-201 심근관류 SPECT와의 비교)

  • Kim Hye-seon;Park Dong Woo;Kim Yongsoo;Kim Young-sun;Choi Yo Won;Jeon Seok Chul;Seo Heung Suk;Hahm Chang Kok;Kim Soon Kil;Ahn You hern;Choi Yoon Young;Park Choong-Ki
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.100-107
    • /
    • 2003
  • Purpose : To assess the usefulness of cardiac MR imaging (MRI) in the diagnosis of acute myocardial infarction and in the assessment of myocardial viability in comparision with T1-201 SPECT. Materials and Methods : We retrospectively studied 17 patients who complained of chest pain and dyspnea with cardiac MRI . The patients were evaluated for the presence or absence of high signal intensity on T2-weighted image (T2wI), abnormal wall motion on 2D-FIESTA, perfusion defect on Gd-DTPA enhanced T1WI, and delayed myocardial enhancement on 15-minutes delay Gd-DTPA enhanced T1WI. The results were correlated with the images on T1-201 SPECT, taken at rest and stress, through which reversibility of perfusion defect was assessed. Results : Both cardiac MRI and T1-201 SPECT proved to be useful methods for diagnosing acute myocardial infarction. In order of decreasing correspondence, T2WI, T1-201 SPECT, delayed enhancement study, and wall motion images all showed significant statistical correlation with the clinical diagnosis of myocardial infarction. Perfusion MRI, on the other hand, showed no significant statistical difference was found between T1-201 SPECT and cardiac MRI. The results on T2WI showed high accordance with those on Tl-201 SPECT, while delayed myocardial enhancement and wall motion studies showed no agreement with Tl-201 SPECT. Conclusion : Cardiac MRI is useful method for diagnosis of acute myocardiac infarction. With respect to the assessment of myocardial viability, the results obtained on cardiac MRI showed high agreement with those on Tl-201 SPECT. However, further study is necessary at this point for standardization and establishment of the methods for assessing myocardial viability on cardiac MRI.

  • PDF

Langerhans Cell Histiocytosis in the Skull: Comparison of MR Image and Other Images (두개골의 랑게르한스 세포 조직구증: 자기공명영상과 다른 영상과의 비교)

  • Lim, Soo-Jin;Lim, Myung-Kwan;Park, Sun-Won;Kim, Jung-Eun;Kim, Ji-Hye;Kim, Deok-Hwan;Lee, Seok-Lyong;Suh, Chang-Hae
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.74-80
    • /
    • 2009
  • Purpose : To evaluate the characteristic MR imaging findings of Langerhans cell histiocytosis (LCH) in the skull and to compare them with those of plain radiography and computed tomography. Materials and Methods : A total of 10 lesions in 9 patients (Age range; 5-42 years, Mean age; 18, all women) with Langerhans cell histiocytosis in the skull were included in our study. Nine lesions in nine patients were histologically confirmed by surgery or fine needle aspiration biopsy. All patients performed with MRI, and plain radiography and CT scan were done in 7 patients (8 lesions). Two experienced neuroradiologists reviewed the radiological examinations independently with attention to location, size, shape and nature of the lesions in the skull and compared the extent and extension of the lesions to adjacent structures. Results : The lesions were distributed in all of the skulls without predilection site. On MRI, the masses were shown as well-enhancing soft tissue masses (10/10) mainly in diploic spaces (8/10) with extension to scalp (9/10) and dura mater (7/10). Dural enhancement (7/10) and thickening (4/10) were seen. The largest diameter of the soft tissue masses ranged 1.1 cm to 6.8 cm, shaped as round (5/10) or oval (5/10). On CT scans, the lesions were presented as soft tissue masses involving diploic space (6/8) and scalp extension (7/8) were also well visualized. Although bony erosion or destruction was more clearly seen on CT rather than those of MRI, enhancement of soft tissue masses and dura were not well visualized on CT. In contrast, all of the lesions in LCH were seen as punched out (4/8), beveled-edge appearance (4/8) osteolytic masses in plain radiography, but scalp and dural extension could not be seen. Conclusion : Characteristic MR findings in patients with LCH are soft tissue mass in diploic space with extension to dura and scalp, and MRI would be better imaging modality than plain radiography or CT.

  • PDF

Cerebellar Activation Related to Various Tasks Using fMRI (다양한 임무 부여시 기능적 자기공명영상에서 관찰된 소뇌의 활성화)

  • Hwang, Seung-Bae;Kwak, Hyo-Sung;Lee, Sang-Yong;Jin, Gong-Yong;Han, Young-Min;Kim, Young-Kon;Chung, Gyung-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.47-53
    • /
    • 2009
  • Purpose : Although it's been known for half a century that unique structures have evolved in the cerebellum and they then became greatly enlarged in the human brain, the function of these structures still remains unknown. The purpose of this study was to assess cerebellar activation during motor, sensory, word generation, listening comprehension, and working memory tasks with using functional magnetic resonance imaging (fMRI). Materials and Methods : Eleven healthy right-handed subjects (Male: female, 6:5, mean age: 27.4years) were imaged on a Siemens 1.5T scanner. Whole brain functional maps were acquired using BOLD EPI sequences in the axial plane. Each paradigm consisted of five epochs of activation vs. the control condition. The activation tasks consisted of left finger complex movement, sensory stimulation of the left hand, word generation, listening comprehension, and working memory tasks. The reference function was a boxcar waveform. The activation maps were thresholded at p = 0.001. SPM 5 evaluated the activated areas and responses within the cerebellum. Results : Cerebellar activation was observed on motor task, word generation task, and working memory task. There were 949 activated areas and the mean fitted and adjusted response was 0.68 during the motor task. There were 319 activated areas and the mean fitted and adjusted response was 0.15 during the word generation task. There were 330 activated areas and the mean fitted and adjusted response was 0.26 during the working memory task. Conclusion : Our results suggest that the cerebellum is involved in a variety of functional tasks, including motor, word generation, and working memory tasks. However, during the motor task, the cerebellum showed a large activated area and a high response. Cerebellar function can be evaluated by fMRI.

  • PDF

Gadolinium-Enhanced Magnetic Resonance Imaging of Atherosclerotic Plaques in Comparison with Histopathology: An In Vivo Study in Aorta of Rabbits (조직병리와 비교한 죽상경화반의 가돌리니움 조영증강 자기공명영상: 토끼 대동맥을 이용한 생체 실험)

  • Choi, Byoung-Wook;Hur, Jin;Lee, Hye-Jeong;Kim, Young-Jin;Kim, Tae-Hoon;Choe, Kyu-Ok
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.81-87
    • /
    • 2009
  • Purpose : We sought to evaluate enhancement of plaque with gadolinium-based contrast agent by magnetic resonance imaging (MRI) in comparison with histopathology, namely lipid-rich and macrophage-rich components that were two representative characteristics of plaque vulnerability using atherosclerotic rabbit aorta in order to determine which histopathologic component is relevant to the enhancement. Materials and Methods : New Zealand white rabbit (n=4, weight 3.0 to 3.5 kg, all male) was used for animal model of atherosclerosis. Atherosclerotic aortic lesions were induced by high-cholesterol diet and double balloon injury. T1-weight axial images were acquired before and after gadolinium-based contrast agent using a 3-T MRI. MR images and the matched histopathological sections (n=35) were divided into 4 quadrants or 3 (n=130). Enhancement ratio (ER, ER=SIpost/SIpre) on MRI was calculated for each quadrant and compared with histopathology in regard to lipid-rich and macrophage-rich areas. Results : Lipid-rich quadrants were 72 and fibrous quadrants were 58. The number of quadrants which had macrophage-rich areas was 105 and that of quadrants which did not have macrophage-rich areas was 25. ER was significantly higher in lipid-rich quadrants than in fibrous quadrants (mean ER 2.25c$\pm$0.41 vs. 2.72$\pm$0.65, p=0.013). ER poorly correlated with macrophage-rich areas when lipid-component was controlled (correlation coefficient -0.203, p=0.236). Conclusion : Lipid-rich plaques showed stronger enhancement than fibrous plaques using a standard gadolinium-based extracellular contrast agent. Macrophage infiltration did not correlate with degree of enhancement. Further study is warranted that account for optimal time of imaging after contrast injection using various plaque models from early to advanced stages and all possible parameters associated with contrast enhancement.

  • PDF