• Title/Summary/Keyword: 연골

Search Result 1,032, Processing Time 0.033 seconds

Chondromyxoid Fibroma of the Hand - Report of two cases - (수부에 발생한 연골점액양 섬유종 - 2례 보고 -)

  • Park, Yong-Koo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.6 no.1
    • /
    • pp.47-51
    • /
    • 2000
  • Chondromyxoid fibroma occurring in the hand is a rare benign tumor. Radiologically and histologically, it should be differentiated from the other benign bone lesions in the hand, such as enchondroma, chondroblastoma, giant cell reparative granuloma and chondrosarcoma. This report is dealt with 59-year-old female and 19-year-old male patient presenting lesions on their digits anddescribed unusual clinical, radiological and pathological features.

  • PDF

Mosaicplasty for the Treatment of the Chondral Defect of the Knee (슬관절의 연골결손에 대한 자가 골연골 이식술)

  • Choi, Nam-Hong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.4 no.1
    • /
    • pp.12-17
    • /
    • 2005
  • Several methods to resurface the lost cartilage of the knee have been used, multiple drilling, microfracture, abrasion arthroplasty Resurfaced cartilages resulting from above techniques are mostly fibrocartilage. Autologous osteochondral graft transfer and autologous chondrocyte transfer are known to resurface the lost cartilage with mostly hyaline cartilage. This article reviews basic researches, indications, operative technique, and clinical results of autologous osteochondral graft transfer.

  • PDF

Medial Meniscus Posterior Horn Root Tear in Adolescent during Sport Activity - A Case Report - (스포츠 운동중 청소년에서 발생한 내측 반월상 연골의 뿌리 파열 - 1예 보고-)

  • Cho, Jin-Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.17 no.1
    • /
    • pp.71-75
    • /
    • 2013
  • Root tear of the posterior horn of the medial meniscus can occur from trauma or chronic degeneration, leading to meniscus extrusion, articular cartilage loss, osteophyte formation, and medial joint space narrowing. It is common on middle age with or without minor trauma. We experienced a case of medial meniscus posterior horn root tear in 13 years old boy during baseball game. We performed 1 direct suture anchor repair for medial meniscus posterior horn root tear in adolescent and report clinical result.

  • PDF

Mosaicplasty for The Treatment of the Chondral Defect of The Knee (슬관절의 연골결손에 대한 자가 골연골 이식술)

  • Choi, Nam-Hong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.147-153
    • /
    • 2008
  • Several methods to resurface the lost cartilage of the knee have been used; multiple drilling, microfracture, abrasion arthroplasty. Resurfaced cartilages resulting from above techniques are mostly fibrocartilage. Autologous osteochondral graft transfer and autologous chondrocyte transfer are known to resurface the lost cartilage with mostly hyaline cartilage. This article reviews basic researches, indications, operative technique, and clinical results of autologous osteochondral graft transfer.

  • PDF

The influence of Collar design on peri-implant marginal bone tissue (Collar design이 임플랜트 주위 변연골 흡수에 미치는 영향)

  • Kim, Jee-Hwan;Jung, Moon-Kyou;Moon, Hong-Suk;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.53-64
    • /
    • 2008
  • Statement of problem: Peri-implant marginal bone loss is an important factor that affects the success of implants in esthetics and function. Various efforts have been made to reduce this bone loss by improving implant design and surface texture. Previous studies have shown that early marginal bone loss is affected by implant neck designs. Purpose: The purpose of this study was to examine the influence of laser microtexturing of implant collar on peri-implant marginal bone loss. Materials and methods: Radiographical marginal bone loss was examined in patients treated with implant-supported fixed partial dentures. Marginal bone level was examined with 101 implant fixtures installed in 53 patients at three periods(at the time of implantation, prosthetic treatment and 6-month after loading). Four types of implants were examined. The differences of bone loss between implants(ITI standard) with enough biologic width and implants(ITI esthetic plus, Silhouette IC, Silhouette IC Laser-$Lok^{TM}$) with insufficient biologic width have been compared. Resorption angles were examined at the time of prosthetic delivery and 6-month after loading. Results and Conclusion: Within the limitation of this study, the following results were drawn. 1. The marginal bone loss of ITI standard and Silhouette IC Laser-$Lok^{TM}$ was less than that of ITI esthetic plus and Silhouette IC(P<0.05). The marginal bone loss between ITI standard and Silhouette IC Laser-$Lok^{TM}$ had no significant statistical difference(P>0.05). There was no significant statistical difference between marginal bone loss of ITI esthetic plus and Silhouette IC(P>0.05). 2. There was no significant difference in marginal bone loss between maxilla and mandible(P>0.05). 3. There was no significant difference in resorption angle among four types of implants(P>0.05). The marginal bone of implants with supracrestal collar design of less than that of biologic width had resorbed more than those with sufficient collar length. The roughness and laser microtexturing of implant neck seem to affect these results. If an implant with collar length of biologic width, exposure of fixture is a possible complication especially in the anterior regions of dentition that demand high esthetics. Short smooth neck implant are often recommended in these areas which may lack the distance between microgap and the marginal bone level. In these cases, the preservation of marginal bone must be put into consideration. From the result of this study, it may be concluded that laser microtexturing of implant neck is helpful in the preservation of marginal bone.

THE EFFECT OF FIBROBLAST GROWTH FACTOR SIGNALING ON CARTILAGE FORMATION (FGF signaling이 연골 형성에 미치는 영향)

  • Park, Choong-Je;Lee, Sang-Won;Nam, Soon-Hyun;Kim, Young-Jin;Ryoo, Hyhn-Mo;Kim, Hyun-Jung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.4
    • /
    • pp.643-653
    • /
    • 2003
  • Fibroblast growth factor (FGF) / FGF receptor (FGFR) mediated signaling is required for skeletogenesis in cluding intramembranous and endochondral ossifications Runx2 ($Cbfa1/Pebp2{\alpha}A/AML3$) is an essential transcription factor for osteoblast differentiation and bone formation. Murine calvaria and mandible are concurrently undergoing both intramembranous bone and cartilage formations in the early developmental stage. However the mechanism by which these cartilage formations are regulated remains unclear. To elucidate the effect of FGF signaling on development of cranial sutural cartilage and Meckel's cartilage and to understand the role of Runx2 in these process, we have done both in vivo and in vitro experiments. Alcian blue staining showed that cartilage formation in sagittal suture begins from embryonic stage 16 (E16), Meckel's cartilage formation in mandible from E12. We analyzed by in situ hybridization the characteristics of cartilage cells that type II collagen, not type X collagen, was expressed in sagittal sutural cartilage and Meckel's cartilage. In addition, Runx2 was not expressed in Meckel's cartilage as well as sagittal sutural cartilage, except specific expression pattern only surrounding both cartilages. FGF signaling pathway was further examined in vitro. Beads soaked in FGF2 placed on the sagittal suture and mandible inhibited both sutural and Meckel's cartilage formations. We next examined whether Runx2 gene lies in FGF siganling pathway during regulation of cartilage formation. Beads soaked in FGF2 on sagittal suture induced Runx2 gene expression. These results suggest that FGF signaling inhibits formations of sagittal sutural and Meckel's cartilages, also propose that FGF siganling is involved in the proliferation and differentiation of chondroblasts through regulating the transcription factor Runx2.

  • PDF

A Morphological Study of Intrachondral Articulations in the Korean Water Deer (한국고라니 갈비연골속관절에 관한 형태학적 연구)

  • Ahn, Dong-Choon;Tae, Hyun-Jin;Park, Byung-Yong;Sim, Jeoung-Ha;Ki, So-Yang;Chung, Ok-Bong;Kim, In-Shik
    • Journal of Veterinary Clinics
    • /
    • v.28 no.4
    • /
    • pp.344-347
    • /
    • 2011
  • Intrachondral articulations are the synovial joints that occur within costal cartilage in artiodactyls. The anatomical structure of Korean water deer differs from that of other deer. However, there have been no reports on the occurrence and shape of intrachondral articulations in the deer. To provide information on these articulations, we examined the occurrence and shape of intrachondral articulations in the Korean water deer by gross findings, radiography, computed tomography (CT), and histological observation. These joints often occur in the second to the tenth ribs. Morphologically, they are spheroidal joints, especially from the third to the eighth ribs, and their configuration is discernable in gross findings, radiography, CT, and histological sections. These basic results would be helpful in the diagnosis and treatment of diseases in the lateral thoracic wall of the Korean water deer.

Synovial Chondroma Causing Radial Nerve Palsy (요골 신경 마비를 유발한 활액막 연골종)

  • Chun, Young-Soo;Kim, Joon-Yong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.13 no.1
    • /
    • pp.55-59
    • /
    • 2007
  • Synovial chondroma is an uncommon benign lesion characterized by metaplastic cartilage formation within the synovial connective tissue, usually intraarticular, commonly affects the knee, hip and elbow. We would like to present the case of a 65-year-old man suffering from synovial chondroma of the right elbow responsible for radial nerve entrapment neuropathy. This is a case of synovial chondroma of the right elbow in an 65-year-old man presenting with pain and restricted joint movement of the right elbow, loss of extension and sensation of the right thumb and wrist. Plain radiographs showed narrowing of elbow joint space, bony spur on the edge of the joint, and radio-opaque sclerotic change of subchondral area. MRI revealed $16{\times}12$ mm sized round mass on the radial head, homogenous low signal on T1WI, heterogenous high and low signal on T2WI. The patient underwent marginal excision of the mass, compressing the radial nerve. Diagnosis was confirmed by histologic examination.

  • PDF

The Effects of X-Irradiation on the chondrogensis of mesenchymal cells (연골세포 분화에 미치는 X-선의 영향)

  • Ha, Jong-Ryeol
    • Journal of radiological science and technology
    • /
    • v.25 no.2
    • /
    • pp.77-82
    • /
    • 2002
  • It is well known that X-irradiation affects on maturing process of differentiated chondrocytes. Nevertheless, It has been remained elusively whether X-irradiation affects the process of differentiation of mesenchymal cells which differentiate into chondrocyte, fibroblast, or muscle cells. In this study, we examined the effect of X-irradiation (with 1 to 10 Gy) on chondrogenesis using the mesenchymal cells of chick limb bud. Our results show that X-irradiation dose-dependently inhibited chondrogenesis. This result suggests that immature chondroblast-like mesenchymal cells are sensitive to X-irradiation. Moreover, X-irradiation affects not only maturing process of chondrocytes, but also inhibits the chondrogenesis. Taken together, we demonstrate that the whole process of differentiation of mature chondrocytes from mesenchymal cells is affected by X-irradiation and undifferentiated cells were more affected by X-irradiation than mature cells.

  • PDF

Anomalous Insertion of Posterior Horn of Medial Meniscus - A Case Report - (내측 반월상 연골 후각의 비정상적 부착 - 1례 보고 -)

  • Min Byoung-Hyun;Ok Soon-Jong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.1
    • /
    • pp.45-48
    • /
    • 2001
  • The anterior horn of the medial meniscus is attached to the anterior surface of the tibia. The anterior horns of the medial and lateral menisci are connect with the transverse ligament. The posterior horn of the medial meniscus is firmly attached to the posterior aspect of the tibia just anterior to the insertion of the posterior cruciate ligament. The authors incidentally found an anomalous insertion of posterior horn of medial meniscus into the anterior horn area during arthroscopic examination in the symptomatic knee joint, which had been ruptured anterior cruciate ligament, and report with literature review.

  • PDF