• Title/Summary/Keyword: 연결플레이트

Search Result 58, Processing Time 0.035 seconds

An Experimental Study on Structural Performance of HRC Composite Beam according to types of Connection Plate with Stud Bolts (HRC 복합보의 연결플레이트 보강법에 따른 구조성능실험)

  • Lee, Soo-Kueon;Yang, Jae-Guen;Song, Chang-Seok;Jang, Eun-Young;Moon, Jun-Chul
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.3
    • /
    • pp.377-384
    • /
    • 2011
  • Recently, for the purpose of reducing work terms and improving performance for construction work, various methods in structure field were developed. This included the HRC system which is applicable to a typical structure (e.g., parking and office building). The HRC system introduced the Gerber Joint to raise structural efficiency and used connection plate to bolt HRC composite beam to H beam in the construction field. In this research, the experimental tests for six specimens, which were in the same field conditions, were conducted with several parameters such as the length and height of the connection plate and the number of stub bolts. The test result was compared with those made by current design codes for the deflection and strains of the main bar. Within the given load, the integration of concrete in beam and connection plate, welded with stud bolts, was verified.

Evaluation of Gusset Plate Connection Stiffness in Braced Frames (가새 골조에서 거싯 플레이트 연결부의 강성 평가)

  • Yoo, Jung Han
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.2
    • /
    • pp.105-113
    • /
    • 2009
  • To improve braced frame performance, the connection strength, stiffness, and ductility must be directly considered in the frame design. The resistance of the connection must be designed to resist seismic loads and to help provide the required system ductility. In addition, the connection stiffness affects the dynamic response and the deformation demands on the structural members and connections. In this paper, current design models for gusset plate connections are reviewed and evaluated usingthe results of past experiments. Current models are still not sufficient to provide adequate connection design guidelines and the actual stress and strain states in the gusset plate are very nonlinear and highly complex. Design engineers want simple models with beam and column elements to make an approximate estimation of system and connection performance. The simplified design models are developed and evaluated to predict connection stiffness and system behavior. These models produce reasonably accurate and reliable estimation of connection stiffness.

Evaluation of Fatigue Strength in Scallop at Field Bolted Joints of Longitudinal Rib and Deck Plate in Orthotropic Steel Decks (강바닥판 데크플레이트와 종리브 현장연결 스캘럽부의 피로강도 평가)

  • Choi, Dong Ho;Choi, Hang Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.6
    • /
    • pp.683-690
    • /
    • 2002
  • Static and fatigue tests were performed to evaluate fatigue strength in scallop at field bolted joints of longitudinal rib and deck plate in orthotropic steel decks. Numerical parametric studies using finite elemtn analysis were also conducted to show the influence of parameters such as length and radius of scallop, and thickness of deckplate on the stress concentration at the scallop. In the low stress level, fatigue tests yielded cracks at the scallop while in the high stress level, catastrophic failure of longitudinal rib occurred following the failure of handhole cover plate. Fatigue strength was compared with JSSC specification and the predicted S-N curves using Shigley and Juvinall methods, and a satisfactory result was obtatined.

A Study on the Fatigue Crack at Welded Joint for Steel Plate Girder Railway Bridge (강철도 플레이트거더교 용접이음부 피로균열의 평가에 관한 연구)

  • Park, Jin-Eun;Kyung, Kab-Soo;Lee, Sung-Jin;Jo, Yun-Jae
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.306-309
    • /
    • 2010
  • 강철도 플레이트거더교의 경우 일반적으로 레일의 폭보다 거더 사이의 폭이 넓기 때문에 거더에 편심이 작용하게 된다. 이러한 편심 영향으로 거더 내측 상부플랜지에 휨변형이 일어나게 되어, 상부플랜지와 수직보강재 용접이음부에 반복하중에 의한 피로균열이 발생되고 있는 것으로 보고되고 있다. 본 연구에서는 공용중인 강철도 플레이트거더교를 대상교량으로 하여 공용하중에 대한 구조해석을 실시하였다. 대상교량에 대한 현장계측을 기초로 구조모델링을 검증하였고, 검증된 구조모델링을 사용하여 열차하중 하에서의 상부플랜지와 수직보강재 용접연결부에서의 피로균열 보강방안에 대한 구조해석을 실시하였다. 또한 상부플랜지와 수직보강재 용접이음부 상세해석을 통하여 피로균열 발생위치를 확인하고 연결이음부의 적절한 보강방안을 제시하고자 한다.

  • PDF

Analytical Investigation for Improved Design Models of Chevron Braced Frames (역V형 가새 골조의 개선된 디자인 모델을 위한 해석적 연구)

  • Yoo, Jung-Han
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.73-78
    • /
    • 2009
  • Steel Braced frames are a commonly-used seismic resisting system, and chevron steel braced frames are a frequently used type of steel braced frame. Recent research has indicated that the seismic performance of braced frames can be improved by designing the braced frame gusset plate connections in a manner that direct reflects seismic deformation demands, and by permitting yielding in the gusset plate at select performance levels. A parametric study using Finite Element (FE) models was conducted to examine the influence of the gusset plate and framing elements on the seismic performance of chevron braced frames, and to calibrate and develop improved design models. The impact of the frame details, including frame sizes, clearance requirements, gusset plate thickness and tapered plate, was explored. The results suggested that proper detailing of the connection can result in a significant improvement in the frame performance. The results also show that the gusset plate thickness has a significant impact on frame performance.

Safety Assessment for the Solar Cell Structure using Finite Element Analysis (유한요소법을 이용한 태양광 집전기 구조물에 대한 안전성 평가)

  • Lee, Yang-Chang;Lee, Joon-Seong;Lee, En-Chul;Lee, Ho-Jung
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.881-884
    • /
    • 2009
  • 태양열을 이용한 발전은 신재생에너지 사업으로 현재 각광을 받고 있는 분야 중의 하나이다. 본 논문에서는 3kv급 태양열 집전기를 유한요소법을 이용하여 돌풍이 불 때 풍하중에 의한 안전성을 평가하였다. 태양열 집전기는 옥외에 설치가 되므로 바람에 대한 영향을 가장 많이 받게 되는데 풍하중은 특히 강한 태풍이 불 때에 가장 높은 설계변수로 자중이나 프레임이 태양을 트레킹 할 때 생기는 동역학적인 변수보다도 크게 된다. 기존에 풍압력에 대한 산술식이 있지만 구조에 따라 적용하는 방법이 다르므로 돌풍이 불 때의 풍속을 적용, 유한요소법을 이용하여 우선 플레이트 프레임 표면에 발생하는 표면 압력을 계산하였다. 구한 표면 압력으로부터 플레이트 부분에 작용하는 하중으로 환산을 구조물에 대입하였고, 구조물이 크고 Mesh수에 문제로 인해 프레임을 두 부문으로 나누어서 포스트 부문과 플레이트 부분에 적용하여 해석하였다. 포스트의 경우에는 플레이트에서 받은 풍하중을 벡터로 나누어서 적용하였고 플레이트 부분에서 작용하는 자중을 고려하여 적용하였다. 플레이트의 경우 돌풍에 안정적이라 하더라도 변형량이 높을 경우를 적용하였다. 포스트 부분과 플레이트 연결부에서도 보강을 통하여 적정범위의 응력이 집전기에 문제가 발생할 수 있으므로 적정한 범위의 변형량을 유지하기 위해 설계변경 하여 안전한 구조물이 되도록 하였다.

  • PDF

A Study on Flash Over Delay Effects on Applied Plate-Fire Spread Prevention Method at Sandwich Panels Structure (샌드위치패널 건축물 플래시오버 지연을 위한 화재확산방지플레이트 시공방법 연구)

  • Kim, Do-hyun;Cho, Nam-Wook
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.79-87
    • /
    • 2017
  • Sandwich panels which are having the both sides are bonded with a heat insulating material with an iron plate are used as factories, warehouse structures as advantages of convenience in construction at economic efficiency of material cost. However, in a panel structure constructed by continuous joining of sandwich panels, a joint portion where a panel and a panel are connected is generated. The joint part is a part which is easily vulnerable to fire because flames easily flow into the melting and deformation of the iron plate during fire. The flames flowing into the panel induce diffusion of fire by rapid burning, causing damage of human life and property. In this research, we developed a flame spread prevention plate to prevent spreading of sandwich panel. This is an improvement of the workability by the anti-spreading construction method of the existing previous research, it can be applied independently to the connecting part where the panel and the panel are coupled, designed to prevent inflow and spreading of flame did. The actual fire test of the test method of KS F ISO 13784-1 of the sandwich panel specimen was conducted and the burning behavior corresponding to the presence or absence of application of the flame spread prevention plate was grasped at the panel connection part and its effect was measured. Inserting a fire spreading plate into the test result panel connecting part is measured by delaying the flashover, prevention of collapse of the specimen, and temperature rise of the opening, effectively improving the fire safety of the panel structure It was confirmed as a method that can be secured. It is judged that panel structure will contribute to ensuring fire safety by applying the fire spread prevention construction method of various methods ensuring the workability and economy of panel connection vulnerable to fire.

Analytical and Experimental Studies on Partially Composite of Steel-Plate Girder Bridges Using Slab Anchors (바닥판 앵커를 사용한 플레이트거더교의 부분합성에 관한 해석 및 실험 연구)

  • Han, Sang Yun;Park, Nam Hoi;Yoon, Ki Young;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.3 s.70
    • /
    • pp.325-332
    • /
    • 2004
  • Cross sections of steel-plate girder bridges are divided into three cross sections of non-composite, partially composite, and fully composite sections, according to their composite characteristics. The Korean provision for the partially and fully composite sections specifies general usage of the stud of shear connectors, whereas the one for the non-composite section specifies empirical usage of slab anchors. However, the actual behavior of the cross sections of steel-plate girder bridges using slab anchors is close not to the non-composite action, but to the partially composite action. Therefore analytical and experimental studies on partial composites of steel-plate girder bridges using slab anchors are performed in this study. Intial stiffness of the slab anchor is obtained by the experimental study for the first time, and the composite characteristic of simple-span and two-span continuous steel-plate girder bridges is investigated by the finite element analyses for the second time. Based on the obtained initial stiffness, the reduction effect of tensile stresses in the concrete-slab on the intermediate support of the continuous bridge is also considered herein.

Comparison on the Behavior according to Shapes of Tension Web member in gap K-joints in Cold-formed Square Hollow Sections (인장웨브재 형태에 따른 각형강관 갭K형 접합부의 거동 비교)

  • Jeong, Sang Min;Bae, Kyu Woong;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.5 s.78
    • /
    • pp.561-568
    • /
    • 2005
  • The object of this paper is to determine appropriateness for use of high-strength tensile bar as a tension web member. The gap K-joint of tensile bar types were compared with gap K-joint of square hollow section (SHS) types. For the same width-to-thickness ratio ($2{\gamma}=33.3$ ), tests were performed on four specimens of the SHS type and eight specimens of the tensile bar type. The comparison of capacity with the experimental results showed a capacity of the SHS type joint to be higher than that of the tensile bartype joint for the same brace-to-chord width ratio. Moreover, the capacity of the SHS type joints increased proportionally to the width ratio ${\beta}$), while tensile bar type joints increased as the tension width ratio (${\beta}2$). In failure mode, SHS-type specimens showed local buckling of the compression brace and plastic failure was observed between the tension brace and chord face, and with the tensile bar type specimens there appeared punching shear failure of the chord face at the toe of the connection plate. It is, therefore, concluded that width-to-thickness ratio should be lower than that of the hollow-section type and the relation between tension and compression width ratio should be considered.

Analytical Study on the Reinforced Details of Orthotropic Steel Deck Bridge (강바닥판 교량의 보강상세에 관한 해석적 연구)

  • Kyung, Kab-Soo;Shin, Dong-Ho;Kim, Kyo-Hoon;Park, Kyung-Jin
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.4
    • /
    • pp.443-451
    • /
    • 2007
  • The improvement of stiffness by the increase of thickness of deck plate or the reinforcement of longitudinal rib is one method among the effective methods to control fatigue damages occurring in orthotropic steel deck. It is likely that the increase of stiffness is effective to restrain local deformation caused by axial load in the steel deck. Therefore, in this study, the parameter studies for the reinforced structural details such as the bulk-head plate and vertical rib which is established to reduce the resultant stresses in the connection parts of the longitudinal rib and floor beam were performed with FE analysis. From the results, it was known that the reinforced structural detail with the bulk-head plate in the longitudinal ribs reduced overall the principal stresses at the connection parts, but the stress concentration increased in the weld toe parts which are occurring fatigue cracks. Also, it was estimated that the reinforced structural detail with the vortical rib in the longitudinal ribs because of the reduction of stress concentration in the weld toe parts is more effective details than the bulk-head plate.