• Title/Summary/Keyword: 연결재 간격

Search Result 45, Processing Time 0.022 seconds

An Experimental study of Buckling Behavior in Built-up Compression Member with Unsymmetric Connectors I - Effect of Distance of Connecting Members - (비대칭 연결재를 갖는 조립식 압축부재의 좌굴 거동에 관한 실험 연구 I - 연결재 간격의 영향 -)

  • Kang, Sanghoon;Han, Manyop;Cho, Byeongdu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.4A
    • /
    • pp.207-215
    • /
    • 2012
  • Structural behavior of built-up compression members with unsymmetric connectors under buckling status has been studied through these experiments. When the distance between adjacent H-300 beams of built-up compression member is 2 m in length, and the H-300 beams are lengthened up to 30 m in length with three-10 m-H-beams by bolts and double arrayed, three specimen having each connector interval 4 m, 5 m, 6 m are experimented for evaluating buckling loads. The buckling loads from the experiments are compared with buckling loads of structural analysis using FEM and buckling loads of Timoshenko Eq. loads in order to figure out how the connectors' interval affects on longitudinal and lateral displacements, also strain of the built-up compression members as well. The result shows that the buckling loads tend to sharply decrease non-linearly according to connectors' interval increases. As well as that, the differences between experimental buckling loads and theoretical buckling loads and between experimental buckling loads and structural analyses buckling loads also have a tendency to be increased as the connector interval increases.

Evaluation of Static Strength of Group Stud Shear Connection in Precast Concrete Deck Bridges (프리캐스트 콘크리트 바닥판 교량의 그룹 스터드 전단연결부 강도평가)

  • Shim, Chang Su;Jeon, Seung Min;Kim, Dong Wook
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.2
    • /
    • pp.333-345
    • /
    • 2008
  • concrete deck bridges are increasingly aplied to twin- girder bridges and open-stel box girder bridges.One of the most dificult isues in the design of shear conect ors is the mater of achieving ful composite action. Many connectors in smal area require a significant section los of precast decks resulting in difficult reinforcement details. In this closer spacing than the required minimum spacing in the design codes was evaluated through static tests. Test results s howed that the ultimate strength decreased as the conector spacing was reduced. The strength enhancement was observed due to aditional reinforcement for precast slabs or for shear pockets. Thus, the design of group stud shear connection needs to anticipate failure modes and the conector failure should be induced. Based on the test results, an empirical equation consi dering stud spacing was proposed to evaluate the ultimate strength of group stud shear conection. Fatigue tests showed n o reduction in fatigue life of the group stud shear conection in the range of this research. Details of the precast decks wer e enhanced using the findings of the study.

An Experimental Study of Buckling Behavior in Built-up Compression Member with Unsymmetric Connectors II - Effect of Type of Connection Members - (비대칭 연결재를 갖는 조립식 압축부재의 좌굴 거동에 관한 실험 연구 II - 연결재 종류의 영향 -)

  • Kang, Sanghoon;Han, Manyop;Cho, Byeongdu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.4A
    • /
    • pp.217-225
    • /
    • 2012
  • Structural behavior of built-up compression members with unsymmetric connectors under buckling status has been studied through these experiments. When the distance between adjacent H-300 beams of built-up compression member is 2 m in length, and the H-300 beams are lengthened up to 30 m in length with three-10 m-H-beams by bolts and double arrayed, three specimen having each connector plate, single channel, double channel are experimented for evaluating buckling loads. The buckling loads from the experiments are compared with buckling loads of structural analysis using FEM and buckling loads of Timoshenko Eq. in order to figure out how the connectors' type affects on longitudinal and lateral displacements, also strain of the built-up compression members as well. The result from the experiments show that the buckling loads 4.2% decreases in double channel connectors and 36.6% decreases in single channel connectors than plate connectors.

Determination of Efficient Shear Stud Spacing in Steel-Concrete Panel(SCP) considering Local Buckling Behavior (국부좌굴 현상을 고려한 강판 콘크리트 패널의 효율적인 스터드 배치 간격 설정)

  • Kim, JoungRae;Lee, WonHo;Kwak, Hyo-Gyoung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.6
    • /
    • pp.479-484
    • /
    • 2017
  • In this paper, finite element analysis of Steel-Concrete panel(SCP) was conducted considering the local buckling behavior and the optimized design of shear studs arrangement was studied by comparing with design guidelines. If the spacing of the studs of SCP is widened, it is easy to be manufactured and the weight fo members become lighter. On the other hand, the steel plate would be vulnerable to the local buckling behavior. Therefore, the guidance and design of SCP limit the maximum spacing of the studs to prevent the development of shear cracks and local buckling, however this is based on the design criteria of the other composite structures. Parameter studies with changes in stud spacing on steel plate and SCP are conducted and the obtained result was compared with values given in design guidelines.

Analysis of Internal Pressure Capacity of Modular Containment Structure for Small Modular Reactor (소형 원자로용 모듈화 격납구조의 내압성능 분석)

  • Park, Woo-Ryong;Yhim, Sung-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.362-370
    • /
    • 2019
  • The internal pressure capacity of a modular containment structure requires analysis to prevent the release of radioactive material in the case of an accident. To analyze the capacity, FEM models were prepared while considering the tendon arrangements and the contact surfaces between precast concrete modules, and then static analyses were carried out. The changing characteristics in the displacement and stress under step-wise loading were analyzed, along with the effects of selected parameters. For comparison, the capacity of a monolithic containment structure was also analyzed. Parametric analyses were done to suggest ranges of parameters such as the tendon force, tendon spacing, tendon location in concrete thickness direction, friction coefficient, and concrete thickness. The tendon force and frictional force provide a combined effect between contact surfaces of modules. The same level of internal pressure capacity can be secured even in the modular containment structure as in the monolithic containment structure by increasing the tendon force with additional tendons.

A Study of Structural Performance of Self-Drilling Screw Connections (직결나사 연결 접합부에 관한 구조성능평가 연구)

  • Park, K.Y.;Jeon, S.H.;Kim, Y.H.;Choi, S.M.
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.5
    • /
    • pp.543-553
    • /
    • 2013
  • As the deep deck plate has the shape of open cross section, It can cause structural problems such as bending torsions due to instability of the section. There are a number of fasteners types which are frequently used on light gage steel diaphragms such as bolts, rivets, welds, and screws. In this study, the structural capacity of the self drilling screw connection between the deep deck and the reinforced cap plate was evaluated by experimental variables such as the arrangement method, numbers of screw, pitch of screw, and head plate thickness.

Fabrification of Segmented Flat-Tubular SOFC cell (Segmented 평관형 SOFC 셀 제조)

  • Park, Sung-Tae;Choi, Byung-Hyun;Ji, Mi-Jung;Choi, Heon-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.137.1-137.1
    • /
    • 2010
  • SOFC cell 하나의 전위차는 약1.1V이기 때문에 발전용으로 사용하기 위해서는 수많은 단전지를 직렬로 연결하는 구조가 필요하다. 이러한 stack의 디자인에서 발생하는 문제를 획기적으로 개선한 형태가 하나의 지지체에 셀을 직렬로 연결함으로 전극의 선폭 및 단위 셀 간의 간격이 기존 평판형, 원통형에 비해 대폭 축소되어 전극 및 연결재의 저항손실을 최소화할 수 있는 Segmented형 SOFC이다. Segmented SOFC에 적용하기 위한 세라믹 다공성 지지체는 연료와 공기에서의 화학적 안정성, 셀의 구성소재와 반응이 없으며 열팽창계수가 유사해야하는 특성을 가져야하는데 그 중에서도 지지체로써 적절한 기계적 강도와 높은 가스투과도가 요구되어진다. 본 연구에서는 고온에서 안정한 Spinel의 MgAl2O4를 주성분으로 하는 다공성 지지체를 압출 성형하여 평관형으로 제조하였으며 활성탄을 기공형성제로 사용하여 연료의 공급이 원활하도록 약 30%의 기공율을 가지는 다공성 세라믹 지지체를 제조하였다. 제조된 세라믹 지지체에 연료극(NiO/YSZ), 전해질(TZ8Y), 공기극(LSM)을 코팅하여 실제 SOFC에 적용이 가능함을 확인하였다.

  • PDF

Effect of Process Parameters on Quality in Joint for Al/Steel Joining a MPW (전자기 펄스 용접을 이용한 Al/Steel 접합시 접합부 품질에 미치는 공정변수 영향)

  • Shim, Ji-Yeon;Kang, Bong-Yong;Kim, Ill-Soo;Park, Dong-Hwan;Kim, In-Ju;Lee, Kwang-Jin
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.27-27
    • /
    • 2009
  • 드라이브 샤프트는 일반적으로 엔진에서 발생된 회전력을 바퀴에 직접 전달하는 동시에 조향기능을 수행하는 자동차 부품이다. 최근에 경량화를 통한 에너지 절감을 위하여 기존 스틸소재를 알루미늄으로 대체하는 방안에 대한 연구가 집중되고 있다. 그러나 알루미늄 단일소재로 드라이브 샤프트를 제조하는 것은 비경제적이며 또한 기 개발된 자동차 부품들과의 연결을 고려하여 알루미늄 튜브와 스틸 요크의 이종금속 접합기술이 요구된다. 전자기 펄스용접은 전자기력을 이용하여 용접대상물을 고속으로 충돌시켜 용접하는 기술로서 열 발생이 적어 재료의 특성차로 인한 결함 및 변형이 발생하지 않아, 이종금속간 고품질 용접이 가능하며, 전자기 펄스 용접부의 품질과 밀접한 관계를 갖는 공정변수 경우 모재와 접합재의 재질 따라 적정 공정변수 범위가 변화되므로 공정에 따른 데이터의 축적은 대단히 중요하다. 전자기 펄스 용접을 이용한 이종금속 접합시 접합부 품질에 영향을 미치는 공정변수는 충전전압, 모재와 접합재 사이의 간격 및 접합재의 직경과 두께의 비(D/T비)로서 보고되었으며, Al/Steel 이종 금속 접합시 이들 공정변수가 접합부에 미치는 영향 및 최적의 공정변수 도출을 위한 연구는 시도되지 않았다. 따라서 본 연구는 전자기 펄스 용접기술을 이용한 Al/Steel 이종금속 접합 실험을 통하여 전자기 펄스용접의 적정성과 최적의 충전전압, 모재와 접합재 사이의 간격, D/T비를 도출하고자 한다. 전자기 펄스 용접 장치는 한국생산기술연구원과 웰메이트(주)에서 공동으로 개발한 $120{\mu}F$의 캐패시터 6개로 구성된 'W-MPW36'을 사용하였으며 이 장치의 최대충전전압과 최대접합용량은 각각 10kV, 36kJ이다. 접합재는 전기 전도율의 높은 Al 1070 파이프를 사용하였으며 모재는 기존 스틸 요크재인 SM45C 환봉을 사용하였다. 기보고된 연구를 통하여 코일과 접합재 사이의 간격이 좁을수록 높은 전자기력이 접합재에 작용하는 것을 확인하였으나 코일내 접합재와 모재 삽입 편의를 위하여 1mm로 설정하였다. 접합부의 품질 평가를 위하여 수압시험을 실시하였으며, 시험 후 접합부 단면을 주사전자현미경(SEM)을 이용하여 관찰하였다.

  • PDF

Ultimate Behavior of Compression Flange Stiffened by Shear Stud on Double Composite Steel Box Girder (이중합성 강박스거더에서 전단연결재에 의해 보강된 압축플랜지의 극한거동에 관한 연구)

  • Lee, Doo Sung;Lee, Sung Chul;Suh, Suk Koo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4A
    • /
    • pp.457-463
    • /
    • 2008
  • The longitudinal stiffener performs its role to increase the local buckling strength by making simple support upon compression flange. In the recent researches, it is investigated that compression flange with point supports on certain arrangement reveals the same strength with longitudinal stiffeners. From this results, it is predictable that shear stud could perform the role of longitudinal stiffener if shear stud embedded in concrete satisfies the requirement to point-support under yield stress of the compression flange. In this study, the researches were performed to investigate the optimally required arrangement space of longitudinal point-support for which the shear stud replacing the longitudinal stiffeners and simultaneously determine the required numbers and space of shear stud for completely composite behavior between compression bottom flange and bottom concrete on the double composite girder system.

Evaluation of Buckling Strength of Surface Plates in Steel-Plate Concrete Walls with Studs and Tie-bars (스터드 및 타이바를 가진 강판콘크리트 벽체의 표면강판 좌굴강도 평가)

  • Koo, Jimo;Lee, Kyungkoo;Kim, Wonki;Lee, JongBo
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.3
    • /
    • pp.129-138
    • /
    • 2016
  • Buckling of surface plates is an important limit state in Steel-Plate Concrete (SC) walls under axial compression. The surface plates may be anchored to concrete using connectors of studs or tie-bars. In this paper, the effects of studs and tie-bars on buckling of surface plates were evaluated by conducting tests. Experiments have three types of connectors; all studs, all tie-bars, and the combination of studs and tie-bars. Also, experiments have the various ratios of stud or tie-bar spacing to surface plate thickness. The experimental investigation shows that the buckling shape and strength of the surface plate of SC wall with the combination of studs and tie-bars have good agreements with that of the surface plate of SC walls with all studs or all tie-bars.