• Title/Summary/Keyword: 역 필터

Search Result 494, Processing Time 0.021 seconds

A Novel Digital Image Protection using Cellular Automata Transform (셀룰라 오토마타 변환을 이용한 정지영상 보호 방법)

  • Shin, Jin-Wook;Yoon, Sook;Yoo, Hyuck-Min;Park, Dong-Sun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.8C
    • /
    • pp.689-696
    • /
    • 2010
  • The goal of this paper is to present a novel method for protecting digital image using 2-D cellular automata transform (CAT). A copyright and transform coefficients are used to generate a new content-based copyright and an original digital image is distributed without any hidden copyright. The parameter, which is called gateway value, for 2-D CAT is consisted of rule number, initial configuration, lattice length, number of neighbors, and etc. Since 2-D CAT has various gateway values, it is more secure than conventional methods. The proposed algorithm is verified using attacked images such as filtering, cropping, JPEG compression, and rotation for robustness.

Comparison of Image Quality among Different Computed Tomography Algorithms for Metal Artifact Reduction (금속 인공물 감소를 위한 CT 알고리즘 적용에 따른 영상 화질 비교)

  • Gui-Chul Lee;Young-Joon Park;Joo-Wan Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.541-549
    • /
    • 2023
  • The aim of this study wasto conduct a quantitative analysis of CT image quality according to an algorithm designed to reduce metal artifacts induced by metal components. Ten baseline images were obtained with the standard filtered back-projection algorithm using spectral detector-based CT and CT ACR 464 phantom, and ten images were also obtained on the identical phantom with the standard filtered back-projection algorithm after inducing metal artifacts. After applying the to raw data from images with metal artifacts, ten additional images for each were obtained by applying the virtual monoenergetic algorithm. Regions of interest were set for polyethylene, bone, acrylic, air, and water located in the CT ACR 464 phantom module 1 to conduct compare the Hounsfield units for each algorithm. The algorithms were individually analyzed using root mean square error, mean absolute error, signal-to-noise ratio, peak signal-to-noise ratio, and structural similarity index to assess the overall image quality. When the Hounsfield units of each algorithm were compared, a significant difference was found between the images with different algorithms (p < .05), and large changes were observed in images using the virtual monoenergetic algorithm in all regions of interest except acrylic. Image quality analysis indices revealed that images with the metal artifact reduction algorithm had the highest resolution, but the structural similarity index was highest for images with the metal artifact reduction algorithm followed by an additional virtual monoenergetic algorithm. In terms of CT images, the metal artifact reduction algorithm was shown to be more effective than the monoenergetic algorithm at reducing metal artifacts, but to obtain quality CT images, it will be important to ascertain the advantages and differences in image qualities of the algorithms, and to apply them effectively.

Usefulness of Deep Learning Image Reconstruction in Pediatric Chest CT (소아 흉부 CT 검사 시 딥러닝 영상 재구성의 유용성)

  • Do-Hun Kim;Hyo-Yeong Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.297-303
    • /
    • 2023
  • Pediatric Computed Tomography (CT) examinations can often result in exam failures or the need for frequent retests due to the difficulty of cooperation from young patients. Deep Learning Image Reconstruction (DLIR) methods offer the potential to obtain diagnostically valuable images while reducing the retest rate in CT examinations of pediatric patients with high radiation sensitivity. In this study, we investigated the possibility of applying DLIR to reduce artifacts caused by respiration or motion and obtain clinically useful images in pediatric chest CT examinations. Retrospective analysis was conducted on chest CT examination data of 43 children under the age of 7 from P Hospital in Gyeongsangnam-do. The images reconstructed using Filtered Back Projection (FBP), Adaptive Statistical Iterative Reconstruction (ASIR-50), and the deep learning algorithm TrueFidelity-Middle (TF-M) were compared. Regions of interest (ROI) were drawn on the right ascending aorta (AA) and back muscle (BM) in contrast-enhanced chest images, and noise (standard deviation, SD) was measured using Hounsfield units (HU) in each image. Statistical analysis was performed using SPSS (ver. 22.0), analyzing the mean values of the three measurements with one-way analysis of variance (ANOVA). The results showed that the SD values for AA were FBP=25.65±3.75, ASIR-50=19.08±3.93, and TF-M=17.05±4.45 (F=66.72, p=0.00), while the SD values for BM were FBP=26.64±3.81, ASIR-50=19.19±3.37, and TF-M=19.87±4.25 (F=49.54, p=0.00). Post-hoc tests revealed significant differences among the three groups. DLIR using TF-M demonstrated significantly lower noise values compared to conventional reconstruction methods. Therefore, the application of the deep learning algorithm TrueFidelity-Middle (TF-M) is expected to be clinically valuable in pediatric chest CT examinations by reducing the degradation of image quality caused by respiration or motion.

Feasibility of Pediatric Low-Dose Facial CT Reconstructed with Filtered Back Projection Using Adequate Kernels (필터보정역투영과 적절한 커널을 이용한 소아 저선량 안면 컴퓨터단층촬영의 시행 가능성)

  • Hye Ji;Sun Kyoung You;Jeong Eun Lee;So Mi Lee;Hyun-Hae Cho;Joon Young Ohm
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.669-679
    • /
    • 2022
  • Purpose To evaluate the feasibility of pediatric low-dose facial CT reconstructed with filtered back projection (FBP) using adequate kernels. Materials and Methods We retrospectively reviewed the clinical and imaging data of children aged < 10 years who underwent facial CT at our emergency department. The patients were divided into two groups: low-dose CT (LDCT; Group A, n = 73) with a fixed 80-kVp tube potential and automatic tube current modulation (ATCM) and standard-dose CT (SDCT; Group B, n = 40) with a fixed 120-kVp tube potential and ATCM. All images were reconstructed with FBP using bone and soft tissue kernels in Group A and only bone kernel in Group B. The groups were compared in terms of image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Two radiologists subjectively scored the overall image quality of bony and soft tissue structures. The CT dose index volume and dose-length product were recorded. Results Image noise was higher in Group A than in Group B in bone kernel images (p < 0.001). Group A using a soft tissue kernel showed the highest SNR and CNR for all soft tissue structures (all p < 0.001). In the qualitative analysis of bony structures, Group A scores were found to be similar to or higher than Group B scores on comparing bone kernel images. In the qualitative analysis of soft tissue structures, there was no significant difference between Group A using a soft tissue kernel and Group B using a bone kernel with a soft tissue window setting (p > 0.05). Group A showed a 76.9% reduction in radiation dose compared to Group B (3.2 ± 0.2 mGy vs. 13.9 ± 1.5 mGy; p < 0.001). Conclusion The addition of a soft tissue kernel image to conventional CT reconstructed with FBP enables the use of pediatric low-dose facial CT protocol while maintaining image quality.

Adaptive Block Watermarking Based on JPEG2000 DWT (JPEG2000 DWT에 기반한 적응형 블록 워터마킹 구현)

  • Lim, Se-Yoon;Choi, Jun-Rim
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.11
    • /
    • pp.101-108
    • /
    • 2007
  • In this paper, we propose and verify an adaptive block watermarking algorithm based on JPEG2000 DWT, which determines watermarking for the original image by two scaling factors in order to overcome image degradation and blocking problem at the edge. Adaptive block watermarking algorithm uses 2 scaling factors, one is calculated by the ratio of present block average to the next block average, and the other is calculated by the ratio of total LL subband average to each block average. Signals of adaptive block watermark are obtained from an original image by itself and the strength of watermark is automatically controlled by image characters. Instead of conventional methods using identical intensity of a watermark, the proposed method uses adaptive watermark with different intensity controlled by each block. Thus, an adaptive block watermark improves the visuality of images by 4$\sim$14dB and it is robust against attacks such as filtering, JPEG2000 compression, resizing and cropping. Also we implemented the algorithm in ASIC using Hynix 0.25${\mu}m$ CMOS technology to integrate it in JPEG2000 codec chip.

A Modeling Study on the AVO and Complex Trace Analyses of the Fracture Bone Reflection (파쇄대 반사에너지의 AVO 및 복소트레이스 분석에 관한 모형연구)

  • Han Soo-Hyung;Kim Ji-Soo;Ha Hee-Sang;Min Dong-Joo
    • Geophysics and Geophysical Exploration
    • /
    • v.2 no.1
    • /
    • pp.33-42
    • /
    • 1999
  • AVO and complex trace analyses mainly used to characterize natural gas reservoir were tested in this paper for a possible application to detection of major geological discontinuities such as fracture zones. The test data used in this study were calculated by utilizing a viscoelastic numerical program which was based on the generalized Maxwell body for a horizontal fracture model. In AVO analysis of a horizontal fracture zone, p-wave reflection appears to be variant depending upon the acoustic-impedence contrast and the offset distance. The fracture zone is also effectively clarified both in gradient stack and range-limited stack in which fracture zone reflection is attenuated with the increasing offset distance. In complex attribute plots (instantaneous amplitude, frequency, and phase), the top and bottom of the fracture Tone are characterized by a zone of strong amplitudes and an event of the same phase. Low frequency characteristics appear at the fracture zone and the underneath. Amplitude attenuation and waveform dispersion are dependent on Q-contrast between the fracture zone and the surrounding media. They were properly compensated by optimum inverse Q-filtering.

  • PDF

Design of EPG Information Player System using DCT based Blind Watermark (DCT기반의 블라인드 워터마크를 이용한 EPG 정보 재생기 설계)

  • Kim, Dae-Jin;Choi, Hong-Sub
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.4
    • /
    • pp.1-10
    • /
    • 2011
  • While the broadband network and multimedia technologies have been developing, the commercial market of digital contents has also been widely spreading with recently starting IPTV. Generally, PC player can display digital contents obtained through middleware like a settop box and can only bring the informations about contents like CODEC, bitrate etc. useful for only experts. But general users want to know more optional informations like content's subject, description etc. So unlike previous PC player, we proposed a player system that can get inserted informations, namely EPG(Electronic Program Guide), without database after bringing contents to PC through settop box. In addition, we also proposed DCT(Discrete Cosine Transform) based blind watermark generating method to insert EPG informations. We can extract watermark without original image and insert robust watermark in proportion to coefficients in frequency domain. And we analyzed and parsed PSI data from MPEG-TS. So we could insert wanted information using watermark from EPG. And we composed UI by extracting EPG information from watermark interted contents. Finally we modularized whole system into the watermark insert/extract application and directshow filter based player. So we tried to design this system so that the general developer can do in a way that is easier and faster.

The Cross-validation of Satellite OMI and OMPS Total Ozone with Pandora Measurement (지상 Pandora와 위성 OMI와 OMPS 오존관측 자료의 상호검증 방법에 대한 분석 연구)

  • Baek, Kanghyun;Kim, Jae-Hwan;Kim, Jhoon
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.3
    • /
    • pp.461-474
    • /
    • 2020
  • Korea launched Geostationary Environmental Monitoring Satellite (GEMS), a UV/visible spectrometer that measure pollution gases on 18 February 2020. Because satellite retrieval is an ill-posed inverse solving process, the validation with ground-based measurements or other satellite measurements is essential to obtain reliable products. For this purpose, satellite-based OMI and OMPS total column ozone (TCO), and ground-based Pandora TCO in Busan and Seoul were selected for future GEMS validation. First of all, the goal of this study is to validate the ground ozone data using characteristics that satellite data provide coherent ozone measurements on a global basis, although satellite data have a larger error than the ground-based measurements. In the cross validation between Pandora and OMI TCO, we have found abnormal deviation in ozone time series from Pandora #29 observed in Seoul. This shows that it is possible to perform inverse validation of ground data using satellite data. Then OMPS TCO was compared with verified Pandora TCO. Both data shows a correlation coefficient of 0.97, an RMSE of less than 2 DU and the OMPS-Pandora relative mean difference of >4%. The result also shows the OMPS-Pandora relative mean difference with SZA, TCO, cross-track position and season have insignificant dependence on those variables.In addition, we showed that appropriate thresholds depending on the spatial resolution of each satellite sensor are required to eliminate the impact of the cloud on Pandora TCO.

Log-Polar Image Watermarking based on Invariant Centroid as Template (불변의 무게중심을 템플릿으로 이용한 대수-극 좌표계 영상 워터마킹 기법)

  • 김범수;유광훈;김우섭;곽동민;송영철;최재각;박길흠
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.9 no.3
    • /
    • pp.341-351
    • /
    • 2003
  • Digital image watermarking is the method that can protect the copyright of the image by embedding copyright information, which is called watermark. Watermarking must have robustness to intentional or unintentional data changing, called attack. The conventional watermarking schemes are robust to waveform attacks such as image compression, filtering etc. However, they are vulnerable to geometrical attacks such as rotation, scaling, translation, and cropping. Accordingly, this paper proposes new watermarking scheme that is robust to geometrical attacks by using invariant centroid. Invariant centroid is the gravity center of a central area in a gray scale image that remains unchanged even when the image is attacked by RST including cropping and proposed scheme uses invariant centroids of original and inverted image as the template. To make geometrically invariant domain, template and angle compensated Log -Polar Map(LPM) is used. Then Discrete Cosine Transform(DCT) is performed and the watermark is embedded into the DCT coefficients. Futhermore, to prevent a watermarked image from degrading due to interpolation during coordinate system conversion, only the image of the watermark signal is extracted and added to the original image. Experimental results show that the proposed scheme is especially robust to RST attacks including cropping.

A Study on Preference of Smoking Booth Design (흡연 부스 디자인의 선호도 조사 연구)

  • Yang, Keun-Young
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.1
    • /
    • pp.183-192
    • /
    • 2017
  • This study aims to suggest improved design for both non-smokers and smokers to minimize inconvenience of smoke, at the same time, allow smoking in comfortable environment. The study was researched in three categories: First, consciousness research regarding smoking booth, second, preference research regarding product design, and third, research on emotional words about smoking booth by emotion evaluation. The result of design preference research was, first of all, smoking booth for smokers should be designed in both notable and familiar shape rather than stiff and rough shape. Second, color for the booth should apply warm colors such as white, pastel, and bright tone rather than prime colors. Third, the internal circulation filter in smoking booth should be managed thoroughly. In addition, extra seats and ventilation design is necessary to prevent passive smoking. The result of emotion evaluation was that people recognized certain words in four aspects. Each image word for factor 1 was "functional emotion', factor 2 was "psychological emotion", factor 3 as "color emotion", and factor 4 as "shape emotion". User-centered service design is necessary for both smokers and non-smokers, to minimize the damage by smoke and to spend time for short break.