• Title/Summary/Keyword: 역치값

Search Result 59, Processing Time 0.026 seconds

Associations Among Different Types of Quantitative Pain Measures in TMD Patients (측두하악장애환자에서 다양한 종류의 정량적 통각검사들의 연관성에 관한 연구)

  • Park, Ji-Woon;Kim, Yong-Woo;Chung, Jin-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.4
    • /
    • pp.413-419
    • /
    • 2007
  • The aims of this study were to investigate the relationships among several types of thermal pain thresholds, and pressure pain thresholds. This study was designed to examine whether there were associations among different types of pain thresholds, and among different recording sites for each pain threshold measurement. Pain sensitivity thresholds including cold pain threshold (CPT), heat pain threshold (HPT), heat pain tolerance threshold (PTT), and pressure pain threshold (PPT) of 56 subjects with symptoms of temporomandibular disorders were measured on temporal muscle, masseter muscle, TMJ, and tibial areas. Thermal pain thresholds including CPT, HPT, and PTT did not show any gender differences. However, women showed significantly lower PPTs than men on all recording sites. Three thermal pain thresholds including CPT, HPT, and PTT showed weak to high correlations on all the recording sites (r= 0.324 to 0.754, p<0.05). PPTs did not show any significant correlations between each thermal pain threshold. The pain threshold of each recording site showed weak to high correlations in all pain threshold measures (r= 0.284 to 0.878, p<0.05). Our study demonstrated that thermal pain thresholds, and pain tolerance thresholds were significantly correlated, but did not show any correlation between thermal pain thresholds and pressure pain thresholds. There were relatively high correlations among the pain thresholds of different recording sites.

Comparison of absolute and relative thermal QST thresholds In the orofacial region of the young Korean women (젊은 한국 여성의 구강안면영역에서 절대적 온도역치와 상대적 온도역치간의 비교)

  • Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.4
    • /
    • pp.367-372
    • /
    • 2013
  • To diagnose sensory nerve damage, patient values for thermal stimuli as quantitative sensory test (QST) can be compared with the values of the general population (absolute reference data) or to values measured at contralateral unaffected side (relative reference data). It is well know that relative reference data are more sensitive for detecting sensory abnormality than absolute reference data. However it is still lack of the studies for comparisons between relative and absolute data. This study aimed to evaluate the validity of relative reference data and compare the sensitivities of the two approaches in the orofacial region. In 19 young Korean women as normal subjects, quantitative somatosensory thermotest were done in the forehead, cheek, mentum, lower lip and tongue tip bilaterally. After we get the standard deviations (SD) of average reference data and relative reference data, the ratios SD absolute data/SD relative data were calculated. Our study showed that relative reference data for side to side comparisons in the same patient have the high ratios than the absolute reference data, i.e. the side to side comparisons with relative reference data exhibit gain in sensitivity in assessment of sensory abnormality.

Correlation Analysis Between Scores of Adolescent/Adult Sensory Profile and Tactile Threshold From Tactile Detection Task (촉각탐지과제를 통한 촉각역치 값과 Adolescent/Adult Sensory Profile 점수의 상관관계 분석)

  • Ju, Yu-Mi
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.10 no.2
    • /
    • pp.1-9
    • /
    • 2012
  • Purpose : Adolescent/Adult Sensory Profile is the questionnaire to evaluate sensory processing based on daily activities. Self-questionnaire commonly tends to be biased to the characteristics of subject, so its validity is low. This study aims to analyze correlation between questions of Adolescent/Adult Sensory Profile and tactile threshold measured from cognitive behavioral experiment. Methods : The tactile threshold was calculated by tactile detection task and tactile stimuli were provided with the consistent current stimulator. The tactile threshold was compared with results of tactile processing items in Adolescent/Adult Sensory Profile and statistical correlation analysis was performed. Results : Scores in Low Registration and Sensation Seeking had positive correlation with the tactile threshold and scores in Sensory Sensitivity and Sensation Avoiding had negative correlation with the tactile threshold. Among them, only Low Registration was statistically significant. Conclusion : The questions in Low Registration(Tactile Processing)are highly correlated with physiological characteristics. As a result, it was shown that sensory inflow is less, if the tactile threshold is high.

  • PDF

Impact of the Crossed-Structures Installed in Streams and Prediction of Fish Abundance in the Seomjin River System, Korea (하천에 설치된 횡구조물의 영향 및 섬진강 수계의 어류 풍부도 예측)

  • Moon, Woon Ki;Noh, Da Hye;Yoo, Jae Sang;Lim, O Young;Kim, Myoung Chul;Kim, Ji Hye;Lee, Jeong Min;Kim, Jai Ku
    • Ecology and Resilient Infrastructure
    • /
    • v.9 no.2
    • /
    • pp.100-106
    • /
    • 2022
  • The relationships between river length and weir density versus fish species observed were analyzed for 210 local rivers in the Seomjin River system (SJR). A nonlinear exponential relationship between river length and number of fish species were observed. Model coefficient was 0.03 and coefficient of determinant (R2) was 0.59, meaning that about 59.0% of total variance was explained by river length variable. Predicted value by model and observed number of species showed a difference. About 110 local rivers (about 52.4%) showed lower value than predictive value. The average index of weir's density (IWD) in the SJR was about 2.7/km, which was significantly higher than that of other river basins. As a result of nonparametric 2-Kimensional Kolmogorov-Smirnov (2-DKS) analysis based on the IWD, the threshold value affecting fish diversity was about 2.5/km (Dmax=0.048, p<0.05). Above the threshold value, it means that the number of fish species would be decreased. In fact, the ratio of the expected species to the observed species was lowered to less than 70%, when the IWD is higher than the threshold value. To maintain aquatic ecological connectivity in future, it is necessary to manage IWD below the threshold value.

A Preliminary Study on Visual Display Terminal Syndrome Prevention System Using Ultrasonic Sensor (초음파 센서를 이용한 거북목 증후군 예방 시스템에 관한 기초연구)

  • Lee, Yoo-Jung;Im, Do Hwi;Yoo, Soo-Han;Na, Ye-Ji;Wang, Changwon;Min, Se Dong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.04a
    • /
    • pp.890-892
    • /
    • 2016
  • 본 연구는 초음파 센서를 사용하여 사용자와 모니터 사이의 거리측정을 통해 거북목 증후군 예방 시스템 개발에 대한 기초연구로 수행하였다. 자세는 바른 자세, 중간 자세, 거북목 유발 자세 총 3가지로, 각 피험자의 역치값을 통해 자세를 구분하였다. 피험자는 총 4명으로 실험을 통해 설정해 놓은 역치값 이상의 신호가 들어왔을 때, LED를 켜서 사용자의 현재 자신의 자세에 대해 피드백을 주도록 구성하였다. 본 연구의 결과를 바탕으로 향후 거북목 증후군 예방과 관련된 다양한 연구에 도움이 될 것으로 사료된다.

Evaluation of metabolic tumor volume using different image reconstruction on 18F-FDG PET/CT fusion image (18F-FDG PET/CT 융합영상에서 영상 재구성 차이에 의한 MTV (Metabolic tumor volume) 평가)

  • Yoon, Seok Hwan
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.1
    • /
    • pp.433-440
    • /
    • 2018
  • Recently, MTV(metabolic tumor volume) has been used as indices of the whole tumor FDG uptake on FDG PET image but it is influenced by image reconstruction. The purpose of this study was to evaluate the correlation between actual volume and metabolic tumor volume applying different SUVmax threshold for different reconstruction algorithm on phantom study. Measurement were performed on a Siemens Biograph mCT40 using a NEMA IEC body phantom containing different size six spheres filled with F18-FDG applying four SBRs (4:1, 8:1, 10:1, 20:1). Images reconstructed four algorithms (OSEM3D, OSEM3D+PSF, OSEM3D +TOF, OSEM3D+TOF+PSF) and MTV were measured with different SUVmax threshold. Overall, the use of increasing thresholds result in decreasing MTV. and increasing the signal to background ratio decreased MTV by applying same SUVmax threshold. The 40% SUVmax threshold gave the best concordance between measured and actual volume in PSF and PSF+TOF reconstruction image. and the 45% threshold had the best correlation between the volume measured and actual volume in OSEM3D and TOF reconstruction image. we believe that this study will be used when the measurement of MTV applying various reconstruction image.

Study on Methods to Improve Image Quality of Abdominal CT Images (복부 CT 영상의 화질 개선 방법에 대한 연구)

  • Seok-Yoon Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.717-723
    • /
    • 2023
  • Liver disease is highly associated with death, and other abdominal diseases are also important causes affecting a person's lifespan, and a CT scan is essential when treating abdominal diseases. High radiation exposure is essential to create images that are good for reading, but managing the patient's radiation exposure is also essential. In this study, a post-processing wavelet algorithm was proposed to improve the image quality of abdominal CT images. Wavelets have the disadvantage of having to set a threshold value depending on the type of input image. Therefore, we experimentally proposed the threshold value of the wavelet and evaluated whether the image quality was effective. As a result of the experiment, the optimal threshold value for abdominal CT images was calculated to be 50. In the case of image 1, noise was improved by 49% and in the case of image 2, by 29%, and the contrast also increased. if the results of this study are applied for post-processing after abdominal CT, image quality can be improved and it will be helpful in disease diagnosis.

Assessment of Viral Attenuation in Soil Using Probabilistic Quantitative Model (확률적 정량모델을 이용한 토양에서의 바이러스 저감 평가)

  • Park, Jeong-Ann;Kim, Jae-Hyun;Lee, In;Kim, Song-Bae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.7
    • /
    • pp.544-551
    • /
    • 2011
  • The objective of this study was to analyze VIRULO model, a probabilistic quantitative model, which had been developed by US Environmental Protection Agency. The model could assess the viral attenuation capacity of soil as hydrogeologic barrier using Monte Carlo simulation. The governing equations used in the model were composed of unsaturated flow equations and viral transport equations. Among the model parameters, those related to water flow for 11 soil types were from UNDODA data, and those related to 5 virus species were from the literatures. The model compared the attenuation factor with threshold of attenuation to determine the probability of failure and presented the exceedances and Monte Carlo runs as output. The analysis indicated that among 11 USDA soil types, the viral attenuation capacity of loamy sand and sand were far lower than those of clay and silt soils. Also, there were differences in the attenuation in soil among 5 viruses with poliovirus showing the highest attenuation. The viral attenuation capacity of soil decreased sharply with increasing soil water content and increased nonlinearly with increasing soil barrier length. This study indicates that VIRULO model could be considered as a useful screening tool for viral risk assessment in subsurface environment.

Appearance of Fish Species Based on the Weir's Density in the Four River Systems in Korea (국내 4대강 수계 하천의 보 밀도에 따른 어류 출현종 분석)

  • Moon, Woon Ki;Noh, Da Hye;Yoo, Jae Sang;Lim, O Young;Kim, Myoung Chul;Kim, Ji Hye;Lee, Jeong Min;Kim, Jai Ku
    • Ecology and Resilient Infrastructure
    • /
    • v.9 no.2
    • /
    • pp.93-99
    • /
    • 2022
  • It was confirmed that the fish diversity decreased with increasing index of weir's density (IWD) in the four river systems. The IWD showed difference with watershed, it was high in the Nakdong River (NDR). Both two river systems of Gum River (GUR) and Yeongsan River (YSR) were similar, whereas relatively lower density observed in the Han River (HNR) system. A result of 2-Dimensional Kolmogorov-Smirnov (2-DKS) as a nonparametic test showed different threshold values affecting fish diversity with the river systems. The p-values based on Dmax, were significantly different at 0.05 level (except for YSR). The threshold values affecting fish diversity were also different with watershed. The values were 1.6/km of the HNR, 1.3/km of the NDR, and 2.3/km of the GUR, respectively. The fish diversity was decreased when IWD is over threshold values. The IWD of total 404 rivers (about 33%) among 1,217 surveyed in this study showed above threshold value. These rivers should be considered first for evaluating river continuity. The IWD and threshold value suggested in this study would be useful for selecting a stream priority for river connectivity study.

Diagnostic Value of CYFRA 21-1 Measurement in Fine-Needle Aspiration Washouts for Detection of Axillary Recurrence in Postoperative Breast Cancer Patients (유방암 수술 후 액와림프절 재발 진단에 있어서의 미세침세척액 CYFRA 21-1의 진단적 가치)

  • So Yeon Won;Eun-Kyung Kim;Hee Jung Moon;Jung Hyun Yoon;Vivian Youngjean Park;Min Jung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.147-156
    • /
    • 2020
  • Purpose The objective of this study was to evaluate the diagnostic value and threshold levels of cytokeratin fragment 21-1 (CYFRA 21-1) in fine-needle aspiration (FNA) washouts for detection of lymph node (LN) recurrence in postoperative breast cancer patients. Materials and Methods FNA cytological assessments and CYFRA 21-1 measurement in FNA washouts were performed for 64 axillary LNs suspicious for recurrence in 64 post-operative breast cancer patients. Final diagnosis was made on the basis of FNA cytology and follow-up data over at least 2 years. The concentration of CYFRA 21-1 was compared between recurrent LNs and benign LNs. Diagnostic performance and cut-off value were evaluated using a receiver operating characteristic curve. Results Regardless of the non-diagnostic results, the median concentration of CYFRA 21-1 in recurrent LNs was significantly higher than that in benign LNs (p < 0.001). The optimal diagnostic cut-off value was 1.6 ng/mL. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CYFRA 21-1 for LN recurrence were 90.9%, 100%, 100%, 98.1%, and 98.4%, respectively. Conclusion Measurement of CYFRA 21-1 concentration from ultrasound-guided FNA biopsy aspirates showed excellent diagnostic performance with a cut-off value of 1.6 ng/mL. These results indicate that measurement of CYFRA 21-1 concentration in FNA washouts is useful for the diagnosis of axillary LN recurrence in post-operative breast cancer patients.