• Title/Summary/Keyword: 역류 시스템

Search Result 58, Processing Time 0.027 seconds

A Study on Jet Fan Start Time in Medium-Length Tunnel Fires (중규모터널 방재용 제트팬 초기 가동시간에 관한 연구)

  • Kim, Doo-Young;Lee, Chang-Woo
    • Tunnel and Underground Space
    • /
    • v.20 no.6
    • /
    • pp.465-474
    • /
    • 2010
  • Although the number of medium-length road tunnels, less than 1 km in length, has increased recently more than 30 percent each year, their ventilation and fire safety system design guidelines have not been established yet. The guidelines for long tunnel design are adopted even for the medium-length road tunnels. Therefore the necessity is brought up to optimize the ventilation and fire safety systems based on their own design guidelines. This study aims at determining the optimal start time of jet fan in case of 20 MW fires by analyzing smoke backlayering range, temperature distribution, range of poor visibility, evacuation time and critical velocity. The CFD study results are expected to contribute to propose the optimal fan operation mode.

Counter-Current Flow Limitation Model Based on the Hyperbolic Two-fluid Equations and Interface Shape Function (쌍곡선형 이상유동 방정식과 경계면 모양함수를 이용한 유체기계의 역류유동제한점 예측방법 개발)

  • 정지환
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.1 no.1
    • /
    • pp.15-22
    • /
    • 2000
  • There are lots of industrial machines of which functions are achieved by operation of multi-phase fluids. Some of them take advantage of the characteristics of counter-current two-phase flow The maximum flow rates of gas and liquid phases which flow in opposite-directions (counter-current flow) are limited by a phenomenon known as a Counter-Current Flow Limitation (CCFL or Flooding) The mass and momentum conservation equations for each Phase were established to build a first-order hyperbolic partial derivative equations system. A new CCFL model is developed based on the characteristic equation of the hyperbolic PDE system. The present model has its applicationto the case in which a non-uniform flow is developed around a square or sharp-edged entrance of liquid phase. The model is able to he used to Predict the operating-limit of components in which mass and heat transfer are taking place between liquid and gas phases.

  • PDF

Development of Aroma Emission System for Reducing Driver's Fatigue (운전자 피로경감을 위한 향 발생 장치 개발)

  • 정순철;우유관;민병찬;김승철;김철중;이정한
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.11a
    • /
    • pp.208-210
    • /
    • 2001
  • 본 연구에서는 운전자의 피로감을 경감시킬 수 있는 자동차용 향 발생장치를 개발하였다. 본 시스템은 공기 압력차에 의해 휘발된 향을 산소와 혼합 시켜 외부로 분사하는 증발 확산 방식을 채택하였다. 또한 3-Port Solenoid Valve를 이용하여 산소만 공급할 수 있도록 또는 산소와 향을 동시에 공급할 수 있도록 두 가지의 분출 경로가 가능하도록 제작하였고 향이 분사되는 배관 앞에 체크 밸브(역류방지기)를 장착하여 한 방향으로만 향이 분출되도록 하였다.

  • PDF

Development of A System Optimum Traffic Control Strategy with Cell Transmission Model (Cell Transmission 이론에 근거한 시스템최적 신호시간산정)

  • 이광훈;신성일
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.5
    • /
    • pp.193-206
    • /
    • 2002
  • A signal optimization model is proposed by applying the Cell-Transmission Model(CTM) as an embedded traffic flow model to estimate a system-optimal signal timing plan in a transportation network composed of signalized intersections. Beyond the existing signal-optimization models, the CTM provides appropriate theoretical and practical backgrounds to simulate oversaturation phenomena such as shockwave, queue length, and spillback. The model is formulated on the Mixed-Integer Programming(MIP) theory. The proposed model implies a system-optimal in a sense that traffic demand and signal system cooperate to minimize the traffic network cost: the demand departing from origins through route choice behavior until arriving at destinations and the signal system by calculating optimal signal timings considering the movement of these demand. The potential of model's practical application is demonstrated through a comparison study of two signal control strategies: optimal and fixed signal controls.

Calculation of Head Loss Coefficient at Surcharged Circular Manhole Using Fluent Model (Fluent 모형을 이용한 과부하 원형 맨홀에서의 손실계수 계산)

  • Kim, Jung-Soo;Kim, Jong-Woo;Kim, Hyung-Min;Yoon, Sei-Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1828-1832
    • /
    • 2008
  • 우수 관거 시스템에서 흐름은 중력에 의해서 흐르고 개수로 흐름과 같이 처리된다. 그러나 유입유량이 관거의 만관 상태를 초과하거나 하류 흐름의 제한 때문에 발생하는 역류의 영향을 받는다면, 우수 관거 시스템은 과부하(surcharge) 상태의 압력흐름이 된다. 개수로 상태에서 맨홀에서의 수두 손실은 일반적으로 무시되지만, 과부하 맨홀에서의 수두손실은 중요하며, 우수 관거 시스템의 전체 손실에 중요한 부분을 차지하게 된다. 이러한 현상은 여러 개의 맨홀을 가지는 우수 관거 시스템에서 특히 중요한 사항이 된다. 현재 계획 또는 설계단계에서 수행되고 있는 관거 시설의 수리계산에서는 연결관의 마찰손실만을 감안하여 수행하고 있으며, 맨홀에서의 수두손실은 고려되지 않는 실정이다. 본 연구에서는 일반적으로 3차원 유체거동의 특성분석에 많이 사용되는 Fluent 모형을 이용하여 과부하 원형 맨홀에서의 흐름특성을 수치모의 하였으며, 맨홀내 손실수두의 변화를 계산하여 손실계수를 산정하였다. 계산된 손실계수는 수리모형 실험을 통하여 산정된 손실계수와 비교하였다. 수치 모형에 의해서 산정된 손실계수 값이 수리모형 실험에 의해서 산정된 손실계수 값보다 약간 크게 산정되었다. 앞으로 난류 모형의 매개 변수들의 조정을 통한 정확한 수치모의 연구가 필요하다고 판단된다.

  • PDF

An experimental study on screw conveyor system of EPB shield TBM (EPB Shield TBM의 스크루 컨베이어 시스템에 관한 실험적 연구)

  • Kim, Sang-Hwan;Kim, Jin-Dae;Park, Inn-Joon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.6
    • /
    • pp.519-530
    • /
    • 2011
  • The screw conveyor system installed in EPB Shield TBM chamber was manufactured in small scale for pilot test to investigate the tunnel muck hauling system that could control the earth pressure and support face thrust force. In this experimental study, there were three different test conditions that include screw angles, screw pitch, and screw RPM. Through analysis on test results based on the muck hauling amount per unit time from screw conveyor, the optimum conditions of screw conveyor were proposed to be efficiently performed by the muck processing system. Finally, this study provided the meaningful results such as optimum screw angle, screw RPM, and screw pitch for anti-reverse flow of muck hauling.

A study on the effect of gusty wind on smoke control performance in road tunnel (돌풍이 도로터널의 제연성능에 미치는 영향 연구)

  • Baek, Doo-San;Cho, Hyeon-Seok;Lee, Seung-Chul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.1
    • /
    • pp.95-108
    • /
    • 2022
  • The increase in the use time of tunnel users due to the lengthening of the road tunnel may increase the evacuation time in case of fire, resulting in a large number of casualties. In order to reduce the casualties caused by fire, the "Road Tunnel Design Manual, Part 6 Tunnel" and "Road Tunnel Disaster Prevention Facility Installation and Management Guidelines" stipulate that ventilation facilities should be installed along with the extension of the tunnel. The ventilation system design factor considers the wind speed of the external natural wind to be at least 2.5 m/s, and it is applied upward according to the characteristics of the tunnel. As a result of analyzing the five-minute average wind speed data in the Daegwallyeong region for the past 6 years, it was analyzed that 15.8% of the windy days were winds of 10 m/s or more, and the maximum was 20 m/s. Therefore, in this study, when a fire occurs in a tunnel, the pattern of natural wind flowing into the tunnel and the backlayering distance of the tunnel fire smoke according to the maximum wind speed were analyzed. As a result, it was analyzed that a backflow of up to 490 m occurs when a gust of 20 m/s blows.

Optimal Water Quality Management due to Operation of Diversion Tunnel (도수터널 운영에 따른 최적 수질 관리)

  • JANG, Suk-Hwan;OH, Kyung-Doo;OH, Ji-Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.358-358
    • /
    • 2016
  • 본 연구에 앞서 가뭄에 따른 충청남도 서부권의 물 부족을 해결하기 위하여 금강 본류로부터 보령댐으로 일정 유량을 도수(diversion)하는 계획이 금강 본류에 미치는 수리적 영향을 1차원 비정상류 해석(unsteady flow analysis)을 통하여 분석하였으며, 본 연구에서는 수리모형 결과와 연계하여 수질 모형을 구축하여 금강 본류 수질에 미치는 영향을 알아보고자 하였다. 조위 영향에 따른 염도의 역류 모의를 위하여 전자해도와 위성영상자료를 활용하여 금강 하굿둑에서 외해 방향으로 약 9km에 이르는 모의 구간을 확장하였으며, 상류단의 진두수위표를 포함한 8개 지천의 유입유량 및 수질, 하구의 조위와 염도, 농공용수 취수시설의 취수량 및 회귀수 수질, 금강 배수갑문 운영, 대상 구간에 인접한 기상대의 기상자료 등을 고려하고 금강 본류를 따라 9개 수질측정소의 수질자료를 이용하여 모형의 보정을 실시하였다. 또한 대상 구간 내 2015년의 갈수기 유황 분석을 토대로 비선형 회귀분석식을 도출하여 2016년 갈수기 예측 유량과 함께 수질-유량 관계식을 도출하여 대상 구간의 수온, 염도, 용존산소(DO), BOD, 조류 등 영향을 분석하였다. 수온 분석 결과, 지점에 따라 2015년 유황 대비 평균 수온 1.79~3.83도, 최고 수온 1.74~4.30도 상승할 것으로 모의되었으며, 염도는 2016년 갈수기 동안의 금강 하굿둑 외해 염도는 담수 방류량의 감소로 전년 동기 대비 평균 53% 증가하는 것으로 모의되어 기수역 생태계에 상당한 영향을 줄 것으로 분석되었으며, 갈수기 동안의 금강 하굿둑 내수의 염도는 배수갑문 개방 빈도, 개방 시간, 개방 정도의 감소에 따른 해수 역류의 감소로 전년 동기 대비 크게 감소할 것으로 모의되었다. 용존산소는 2016년 갈수기 동안의 용존산소 농도는 지점에 따라 전년 동기 대비 평균 4~11% 감소하는 것으로 모의되었으며, 2016년 갈수기 동안의 BOD 농도는 지점에 따라 전년 동기 대비 평균 30~57% 증가하는 것으로 분석되었다. 조류는 지점에 따라 전년 동기 대비 평균 29~67% 증가하는 것으로 모의되었다. 유량의 감소에 따른 수온 증가 및 수질 악화의 영향이 있을 것으로 분석되나, 도수에 따른 영향은 상대적으로 제한적인 것으로 분석되었다.

  • PDF

Water Quality Change due to Singok Submerged Weir Removal Considering Tide (조석운동을 고려한 신곡수중보 철거에 따른 수질변화 연구)

  • Jang, Suk Hwan;OH, Kyung Doo;Oh, Ji Hwan;Han, Su Hee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.335-335
    • /
    • 2015
  • 행주대교 하류 약 3km 지점에 위치한 신곡수중보는 한강종합개발 사업 중 하도정비로 인한 상시수위 저하로 인해 발생하는 문제를 해결하기 위해 설치되었으며, 취수장의 취수심 확보, 주운수심 확보, 염수 역류에 의한 생태계의 변화 방지, 하천 주면의 지하수위 저하 방지 목적으로 건설되었다. 본 연구에서는 신곡수중보의 존치, 이전 혹은 철거로 인한 수질변화를 모의를 실시하였다. 한강 본류와 임진강 합류를 고려하여 총 495개 수질모의 셀을 구성하였고, 수질모의를 위한 WQ Cell은 길이가 100 m~340 m로 임진강 47개, 한강 448개로 총 495개의 셀로 구성하였으며, 주요 지천이나 오염원으로 신곡보 하류에는 공릉천, 신곡보와 잠실보 사이에는 창릉천, 서남과 난지물 재생센터, 안양천, 홍제천, 중랑천, 탄천, 잠실보 상류에는 왕숙천, 월문천, 덕풍천 등 9개 지천과 2개 물 재생센터를 포함하였으며 잠실보 상류에서의 생활용수 취수를 고려하였다. 수온, BOD, 조류의 경계조건은 환경부에서 제공한 2011년 3월과 4월의 측정자료를 사용하였다. 그 결과, 신곡보 철거시 수온의 변화는 서해로부터의 차가운 해수의 역류 증가로 임진강, 파주, 전류, 장항습지까지 수온이 최대 $0.94^{\circ}C$ 크게 하강할 것으로 나타났으나 행주, 가양, 영등포는 오히려 수온이 $0.03{\sim}0.04^{\circ}C$ 미미하게 상승할 것으로 나타났으며 현재의 신곡보가 수온의 급격한 변화를 완층하는 역할을 담당하여 왔으나 보가 철거되면서 이러한 수온 완충역할이 사라지기 때문으로 분석되었다. 신곡보 철거시 BOD 농도의 변화는 잠실보 하류쪽으로는 BOD 농도가 최대 1.02 mg/l 감소하는 등 전반적으로 수질이 크게 개선될 것으로 나타나는 반면 잠실보 상류쪽으로는 BOD 농도가 최대 0.56 mg/l 증가하며 현재의 1급수 수질에서 2급수로 수질이 악화되어 상수원 수질 관리가 어려울 것으로 예상되었다. 신곡보 철거시 조류 농도의 변화는 잠실보 하류쪽으로 조류 농도가 최대 1.85 mg-A/l 감소하는 등 전반적으로 수질이 크게 개선될 것으로 나타나는 반면 잠실보 상류쪽으로는 조류 농도가 최대 0.40 mg-A/l 증가하며 고조위 기간에는 조류주의보 기준 1.5 mg-A/l를 초과하는 경우도 발생하여 상수원 취수에 문제가 발생할 가능성이 있는 것으로 나타났다.

  • PDF

Hydrogen Pumping Characteristics of a Scroll Pump (스크롤 펌프의 수소 배기특성)

  • In S. R.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.1
    • /
    • pp.14-23
    • /
    • 2006
  • The scroll pump is widely used in ultra clean vacuum systems. However, there is no commonly available information on the hydrogen pumping characteristics of this pump, which creates a difficulty in determining whether the scroll pump can be used or not in a fusion experiment system where hydrogen ,is the main working gas. In this paper the experimental setup, measurement procedures, experimental results, and discussions on the pumping speed, the maximum compression ratio and the back-streaming properties of the scroll pump, especially for the hydrogen gas, are reported.