• Title/Summary/Keyword: 여성 기술인

Search Result 1,479, Processing Time 0.032 seconds

A Study of both Femurs Bone Densitometry's Difference for Exercise (운동유무에 따른 양측 대퇴골 골밀도 차이에 관한 연구)

  • Jang, Eun-Ju;Kim, Eun-Hye;Kim, Ho-Sung;Shin, Sang-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.73-76
    • /
    • 2009
  • Purpose: Bone mineral densitometry test region advised by ISCD (International Society for Clinical Densitometry) is both site in case of femur, whereas our medical center measures left femur except for few extraordinary cases. It is said that right-handers had higher mean femur BMD in the left side than in the right side, but the factor influence the femur BMD is unknown. Thus, we investigate whether testing left femur only is a adequate clinical diagnosis. Materials and Methods: Subjects were 209 right-handers and 20 left-handers patient in Asan Medical Center from July to August, 30 to 70 years of age ($51{\pm}6.7$). Subjects fill out the questionnaire on hand preference and taking regular exercise. Total BMDs of bilateral femur were measured with GE Lunar Prodigy advance densitometer, and the statistical soft ware SPSS 12.0 for windows was used for statistical analysis. Results: In the total sample of the exercise group (n=127), the difference of both femur mean BMDs are $0.001{\pm}0.127\;g/cm^2$ and the non-exercise group's (n=102) both femur difference is $0.002{\pm}0.126\;g/cm^2$, there is no significant difference. And in exercise group, classified according to hand preference, each t-value is shown at right handers (n=114) are 0.65, left handers (n=13) are -0.39. Also, In non-exercise group, right handers (n=95) are -0.78, left handers (n=7) are -0.64. In the 95% confidence limit, there was no statistically significant difference (p>0.05). Conclusions: In recently researchs, there have been differences between both femurs according to hand preference. However, Our study have no significant difference both femurs BMDs. Therefore we suggest that BMD measurement of femur has no problem only one side, except for particular case like femur operation.

  • PDF

Establishment of Reference Intervals of Osteocalcin according to Age in Women for Health Promotion Center (건강검진이 의뢰된 여성의 연령에 따른 Osteocalcin의 참고범위 설정)

  • Kang, Ji-Soon;Yoo, Byoung-Joo;Oh, Jung-Eun;Kim, Geon-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.104-111
    • /
    • 2009
  • Purpose: Osteocalcin is also known as the bone gamma-carboxyglutamic acid (Gla) protein (BGP), is noncollagenous bone protein synthesized by osteoblasts. Serum concentrations of Osteocalcin have been used as a biochemical marker of bone turnover. The reference intervals of Osteocalcin is categorized by kit corporation according to the age. However, each laboratory should establish its own reference intervals. In this study, the variation in the serum Osteocalcin level were used to find actual standard age-specific Osteocalcin reference intervals. Materials and Methods: We have selected 864 healthy females aged 20~80 years who visited a health promotion center between Aug. 2007 and Sep. 2008. The Osteocalcin IRMA Kit (OSTEO-RIACT, CIS Bio international, Gif-sur-Yvette, France) was used for the quantification. Each results were analyzed with the SPSS 12.0 statistical software. Results: The analyzed reference intervals of Osteocalcin by using Hoffmann method are from 8.8~39.4 ng/mL to 6.3~28.8 ng/mL for the case of the age from 20 to 30, from 7.7~31.9 ng/mL to 5.9~17.4 ng/mL for the case of the age from 31 to 40, and from 8.0~36.0 ng/mL to 5.5~20.1 ng/mL for the case of the age from 41 to 50, and from 8.0~50.5 ng/mL to 6.7~27.0 ng/mL for the case of the age from 51 to 60, and from 12.9~55.9 ng/mL to 7.5~27.5 ng/mL for the case of the age from 61 to 80. Reference intervals of Osteocalcin were not in agreement with those recommended by the manufacturers. Conclusions: Osteocalcin is used as an indication of metabolic bone diseases. So in our study we wanted to provide reference intervals of Osteocalcin that can be useful to a clinical decisions. Also, previous reference intervals should not be re-used and new intervals should be set by continuous analyzing.

  • PDF

The Study on the Dilution Time of Radioactive Tracer in Estradiol Measurement (Estradiol 검사 시 방사성 추적자의 희석시간에 대한 고찰)

  • Lee, Hae Yeon;Seo, Han Kyung;Jang, Yi Sun;Kim, Hee Jeoung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.44-48
    • /
    • 2017
  • Purpose Estradiol (E2) is a steroid hormone mainly produced in women and is a useful indicator for diagnosis of gynecological diseases, menstrual cycle, menopause, and precocious puberty. E2 measurement is performed by diluting the $^{125}I$ radioactive tracer and tracer buffer in the kit. However, It was not precisely specified when the period of tracer is available after activating. The purpose of this study was to determine the appropriate dilution time based on the measurement value with dilution time. Materials and Methods From December 2016 to February 2017, 60 E2 samples with concentrations ranging from 8 to 4577 pg/mL were divided into low, medium, and high concentrations. Dilution of the $^{125}I$ tracer was performed on a 230 RPM agitator for 30 minutes, 1 hour 30 minutes, and 2 hours 30 minutes, respectively. 24 hour dilution was gently shaken and refrigerated. To verify the difference and significance of the results according to the dilution time, a test of normality was performed using SPSS 18.0 and analyzed by Kruskal-Wallis test. The measured value according to the dilution time was compared with the interquartile range of the absolute error. Results The results of Kruskal-Wallis test were not significant (P>0.05). Measurement results are showed as interquartile range of absolute error. At low concentration, it is 0.052 between 1 hour 30 minutes and 2 hours 30 minutes, and 0.105 between 30 minutes and 1 hour 30 minutes. At medium concentration, 0.062 between 30 minutes and 1 hour 30 minutes, and 0.038 between 1 hour 30 minutes and 2 hours 30 minutes. At high concentration, it is 0.029 between 1 hour 30 minutes and 2 hours 30 minutes, and 0.06 between 2 hours 30 minutes and 24 hours. Conclusion There were no statistically significant differences. However, the change in the measured value is the smallest between 1 hour and 30 minutes to 2 hours and 30 minutes. Therefore, we recommend diluting time between 1 hour 30 minutes and 2 hours 30 minutes.

  • PDF

Improvement of Melanin Production and Skin Tone by Fullerene Serum (플러린 함유 세럼의 멜라닌색소 및 피부톤 개선 효과)

  • Lim, Hyun-Sook;Lee, Mi-Bun;Lee, Jae-Nam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.455-464
    • /
    • 2018
  • This study investigated whether the whitening effects of fullerene serum occurred through improvement of melanin production and skin tone and evaluated its potential for use as a cosmetic material for adult women aged 30-55 with dull skin color and pigmentation. Subjects were divided into a control group with fullerene-less serum (B) and an experimental group with serum containing 0.1% fullerene (A) and evaluated over 8 weeks. Visual assessment and measurement of skin conditions (melanin index, skin brightness) were conducted before use of and 4 and 8 weeks after use of the product, and a questionnaire survey and safety assessment were conducted at the end of the experiment. The results revealed that the highest decrease was 0.37% in the experimental group (A) after eight weeks of use of the product, but that this difference was not statistically significant. Moreover, no significant differences were observed upon inter-group comparison. Evaluation of changes in the melanin index and inter-group comparison revealed a significant decline in the experimental group (A) at all time points. Additionally, the $L^*$ value (skin brightness) of the experimental group (A) showed a significant increase (improvement) after eight weeks, while in inter-group comparison revealed a significant increase (improvement) at all time points (4 and 8 weeks later) (p<0.05). Based on a questionnaire survey of efficacy, positive response rates such as improvement of the target parts on week 8 were high in terms of 'improvement of skin color.' Moreover, the safety assessment revealed no adverse reactions. In conclusion, serum containing 0.1% fullerene revealed improved melanin production and skin tone (brightness) and confirmed its potential for use as a cosmetic material with brightening efficacy. Taken together, the results of this study indicate systematic investigation of the effective application and cosmetics formulations of this product are warranted.

A Study on the Relationships Between Demographic Characteristics of Entrepreneurial Candidates, their Developmental Level of Entrepreneurial Traits and Choice of Business Field (예비 창업자의 인구학적 특성과 창업성향 발달도 및 창업업종 선정에 관한 연구)

  • Choi, Joong Seog;Sung, Sang Hyeon
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.10 no.5
    • /
    • pp.1-13
    • /
    • 2015
  • The purpose of this research is to do exploratory analysis on the relationships between demographic characteristics of entrepreneurial candidates and their developmental level of entrepreneurial traits as well as the choice of business field. We analyzed gender, age, and educational level of the entrepreneurial candidates and their developmental level of entrepreneurial traits such as achievement tendencies, degree of awareness, planning skills, sincerity, interpersonal relationship, and problem-solving skills. Industry fields were classified into 4 types: restaurants, retail, services, internet business. Descriptive statistical analyses, logistic regressions, and variance analyses were performed about the sample data gathered from 1,441 persons since the year 2002 to 2014. Males and highly educated above university preferred service industry than restaurant, retail, and internet business. Females preferred internet business, retail, and restaurants than service industry field. The young persons under 20 showed higher probability to choose internet business. The college level and high school graduates preferred retail and restaurants than service industry. The developmental level of entrepreneurial traits were higher in male and highly educated. By this study, we could find the divide between groups with high and low probabilities of failure: restaurants and retail field showed higher failure probability than service industry in the business fields of self-employed. Furthermore, we could identify that entrepreneurial traits also had been developed differently depending on the groups. It is necessary to refrain from entering into the fields with high failure probabilities as well as to provide supporting policies to build the systems and environment to reduce the cases to begin new business without special knowledges and know-hows. The competency development training should be provided in the early stage of start-ups considering their entrepreneurial traits and aptitudes. Not only the assessment of the entrepreneurial traits but also professional counseling from initial stage are necessary.

  • PDF

A Study on Absorbed Dose in the Breast Tissue using Geant4 simulation for Mammography (유방촬영에서 Geant4 시뮬레이션를 이용한 유방조직내 흡수선량에 관한 연구)

  • Lee, Sang-Ho;Lee, Jong-Seok;Han, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.345-352
    • /
    • 2012
  • As the breast cancer rate is increasing fast in Korean women, people pay more attention to mammography and number of mammography have been increasing dramatically over the last few years. Mammography is the only means to diagnose breast cancer early, but harms caused by radiation exposure shouldn't be overlooked. Therefore, it is important to calculate the radiation dose being absorbed into the breast tissue during the process of mammography for a protective measure against radiation exposure. Because it is impossible to directly measure the radiation dose being absorbed into the human body, statistical calculation methods are commonly used, and most of them are supposed to simulate the interaction between radiation and matter by describing the human body internal structure with anthropomorphic phantoms. However, a simulation using Geant4 Code of Monte Carlo Method, which is well-known as most accurate in calculating the absorbed dose inside the human body, helps calculate exact dose by recreating the anatomical human body structure as it is through the DICOM file of CT. To calculate the absorbed dose in the breast tissue, therefore, this study carried out a simulation using Geant4 Code, and by using the DICOM converted file provided by Geant4, this study changed the human body structure expressed on the CT image data into geometry needed for this simulation. Besides, this study attempted to verify if the dose calculation of Geant4 interlocking with the DICOM file is useful, by comparing the calculated dose provided by this simulation and the measured dose provided by the PTW ion chamber. As a result, under the condition of 28kVp/190mAs, the Difference(%) between the measured dose and the calculated dose was found to be 0.08 %~0.33 %, and at 28 kVp/70 mAs, the Difference(%) of dose was 0.01 %~0.16 %, both of which showed results within 2%, the effective difference range. Therefore, this study found out that calculation of the absorbed dose using Geant4 Simulation is useful in measuring the absorbed dose in the breast tissue for mammography.

The Clinical Usefulness Measurement of the Whole Body Percent Fat Calculated by the Part Bone Mineral Density Measurement (부분골밀도 측정을 통해 산출되는 체지방률의 임상적 유용성에 대한 평가)

  • Kang, Young-Eun;Kim, Eun-Hye;Kim, Ho-Sung;Choi, Jong-Sook;Choi, Woo-Jun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.3-9
    • /
    • 2011
  • Purpose: Generally dual energy X-ray absorptiometry has been used for the purpose of evaluation of osteoporosis and treatment. Recently the interest of obesity came to be high and body percent fat test is increasing. Existing measure of body fat have to scan the whole body can be evaluated, but only lumbar spine and hip measurements was assumed to be whole body fat as well as improving the software. It tries to check whether the part measured value not being whole body measurement has the validity or not compared with the value calculated with the method that it is different, it forgives through a correlation with a (BIA) and (BMI). Materials and Methods: In 2010, the body percent fat was measured among the examinee coming to the Asan Medical Center public health care center from March till August against 90 females more than 40 years old through (DXA) and BIA. BMI utilized the value which wrote an hight and weight measured through the body measuring instrument in the examinee information and is automatically calculated. In addition, it classified as the low weight ($13-18.5kg/m^2$), normal ($18.5-25kg/m^2$), and corpulence ($25-30kg/m^2$) based on BMI and so that it could check whether there was the difference according to the weight or not BMI and BIA and correlation between DXA were analyzed in each group. The statistical program for the analysis used SPSS 12.0. Results: The comparison of DXA at 3 which it divides into the low weight and normal and corpulence groups and BIA did not show the difference noted statistically in all groups and the between group comparison was exposed to do not have a meaning. The body percent fat measured by the correlation analysis result DXA at the state that it doesn't divide into the group showed the high correlation (r=0.908, p0.01) noted statistically compared with BMI and showed the high correlation noted statistically in a comparison with BIA (r=0.927, p0.01). Conclusion: It confirmed that the whole body percent fat presumed from the part bone density measurement showed the excel correlation compared with BIA and BMI and information is high. There is still no clear standard about the presumed whole body percent fat and it is difficult to evaluate the fat evaluation by the bone mineral density measurement. However, it is determined that the information offering which is more objective through the comparative study with the body percent fat which is very efficient and in that it can obtain till the information about a fat as well as diagnosis of the osteoporosis through the bone density checkup is measured by the afterward telegraph bone density checkup and is clinically useful is possible.

  • PDF

Comparison of Estradiol Results according to Manufacturer (제조회사에 따른 Estradiol 결과값의 비교)

  • Kim, Dae-Woon;Shin, Hee-Jung;You, Tae-Min;Noh, Gyeong-Woon;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.101-105
    • /
    • 2011
  • Purpose: Estradiol in the menstrual cycle and ovulation induction as an important test of currently national nuclear medicine laboratory in the normal patients and patients with infertility tests are being performed. For the diagnosis of menopause is an important test with follicle stimulating hormone (FSH) and Luteinizing hormone (LH). Currently participating in external quality control of the nation's hospitals that is 54 percent of 37 hospitals, 20 hospitals have been using A's reagent. The kit's test results are highly different from other kit comes with the test results of specimens have been found. And for the phenomenon is to study the problem. Materials and Methods: Estraiol test were referred to our hospital which results of samples as more than 100pg/ml 75 specimens measured by radioimmunoassay(RIA) test with company A company B company C company D Kit, Chemiluminescent assay (CMIA) to examine and compare to the results from april to August in 2010. Results: Kit for each manufacturing company as measured by the results obtained using the average value of the correlation coefficient (R2) and A company 0.8906 B 0.9527 C 0.9547 and D company correlation coefficient of 0.873 showed a good correlation that measuring the results of A company high concentrations when Company B Company C Company D with CMIA test concentrations measured low results that the two cases were discovered specimens. Conclusion: Most of the test results of 75 samples came up with a similar trend, but two cases were reported in the patients very differently. A company result reported higher than 700 pg/ml, while the rest of other test results report was approximately 10 pg/ml. The common point of two samples more than 50 years patients are estimated to be diagnosed with cancer in postmenopausal patients receiving treatment and levels of FSH were found to be greater than 50 mIU/ml. Did not identify the exact cause. I suggest if you are using A company kit that need to again check when Estradiol result and follicle stimulating hormone results is higher.

  • PDF

Usefulness of Prone Position on PET-CT in Breast Cancer (유방암 PET-CT 검사에서 Prone(복와위)자세의 유용성 평가)

  • Park, Hoon-Hee;Kim, Sei-Yung;Kim, Jung-Yul;Park, Min-Soo;Lim, Han-Snag;Jung, Suk;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho;Lee, Yung-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.44-48
    • /
    • 2008
  • Purpose: In FDG-PET/CT of breast cancer, a sensitivity was 80~96% and a specificity was 75~95% commonly. It was valuable to identify a cancer in early stage been difficult in Mammography. Most of the PET/CT scans have been examined on supine position, so, the image of breast has been acquired by reconstructed whole body scan image. However, using prone position with a compensator, a shape of breast was reassembly shown to be real by gravity. Therefore, the purpose of this study was to evaluate diagnostic value of prone position in FDG PET-CT of breast cancer. Materials and Methods: 30 female patients with doubtful or positive breast cancer were examined. The PET-CT whole body scan was acquired at 60 minutes after $^{18}F$-FDG injection on Supine position. Then, regional breast spot scan was progressed on prone position using a compensator. Each image was evaluated by physicians blinded to patient's data, and statistical analysis did through SUVs measured in PET-CT images. Results: In 27 of 30 patients, prone position was shown accurate discrimination and diagnostic value, but in another 3 patients had a lesion 1cm below, PET-CT couldn't detect it, unlike MRI. Consequently, prone position distinguished a lesion better than Supine position, because of low degree of metamorphosis by gravity. The SUVs analysis of each position was significant (p value=0.004). Conclusion: In PET-CT of breast cancer, prone position could detect micrometastasis as well as primary lesion, better than supine position. Therefore, this study proposes that any technical change considered morphological feature like prone position can offer adequate and useful diagnostic information, together with complementary quantitative analysis.

  • PDF

Comparing the Change in SUVmax Over Time by the Type of Ductal Breast Carcinoma (유방암 환자 중 유관에서 발병되는 암의 종류(IDC와 DCIS)별 시간경과에 따른 SUVmax 변화에 대한 비교)

  • Hyoung, Mi-Jin;Kim, Jeong Nip;Moon, Pyeong Soo;Kim, Kil Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.140-144
    • /
    • 2014
  • Purpose: The recent surge in breast carcinoma patients is reported in a variety of statistics. Breast cancer occurs mainly from duct and lobulus: 85% is from the breast ducts. The present study is aimed to distinguish the difference in $SUV_{max}$ changing over time by identifying the type of cancers attacking from the duct. Materials and Methods: The subjects of the study are 291 female breast cancer patients who have visited the present PET/CT center from July 1, 2012 to July 23, 2013. Based on the pathological results, 248 IDC (invasive ductal carcinoma) patients and 43 DCIS (ductal carcinoma in situ) patients were selected. In the same manner as the general PET/CT scan (3.7 MBq/Kg), F-FDG was injected, followed by the primary test (Routine tests) after 1 hr, and the secondary test (Delay test) after another hr. $SUV_{max}$ was measured after setting ROI in the lesion based on the data from the two tests. Results: As the comparative result of the change in the lesion $SUV_{max}$ between the two groups, IDC group's $SUV_{max}$ showed M=7.11 and SD=5.405 in the primary test and increased M=7.11 and SD=5.405 in the secondary test (P<0.05); DCIS group's $SUV_{max}$ showed M=2.739, SD=1.229 in the primary test and increased M=2.614, SD=1.470 in the secondary test (P<0.05). Conclusion: As the comparative result of $SUV_{max}$ over time between the groups, IDC showed increased $SUV_{max}$ in the secondary test (Delay test) compared to the primary test (Routine test) (P=0.000); DCIS showed decreased $SUV_{max}$ in the secondary test (Delay test) compared to the primary test (Routine test) (P=0.039). It was confirmed through this study that the change in $SUV_{max}$ has occurred over time by the type of breast cancer (IDC or DCIS) occurring from the breast ducts. However, the onset of breast cancers (ILC, LCIS) from the lobulus was not discussed due to the lack of samples. Future research on the breast cancers from the lobulus is suggested.

  • PDF