• Title/Summary/Keyword: 여과 수준

Search Result 136, Processing Time 0.03 seconds

Extraction Method for Paraquat from Soil (토양중 Paraquat의 효과적인 추출방법)

  • Kwon, Jin-Wook;Kim, Yong-Se;Choi, Jong-Woo;Lee, Kyu-Seung
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.3
    • /
    • pp.239-244
    • /
    • 1997
  • To develope more effective extraction methods for paraquat in soil, some modification methods were accomplished in two different types of soil. For extraction of tightly bound-paraquat, conc. HCl 70ml were added with different shaking times, and then $H_2SO_4$ reflux were performed for an hour. In this case, 60 minutes shaking were optimum and recovery were increased more $1.09{\sim}1.50$ folds(84.0% in high clay contents soil, but 96.7% in low clay contents soil) and the long-time consuming step, filtration were easily done, with decreasing filtration time were shorter 4.6 folds(ca. $11{\sim}14min.$). than general paraquat analytical method(ca. $55{\sim}65min.$). And only $H_2O_2$ digestion with different volume and refluxing time resulted in recovery increasing. Nevertheless, considering analyst's safety, 30ml of $H_2O_2$ addition and 30 minutes reflux were regarded as optimum condition. Although, Kjeldahl digestion with $H_2O_2$ showed relatively high recovery, it is not significant statistically. For extraction of loosely bound-paraquat, 0.01, 0.1, 1.0, 10.0M of $NH_4Cl$ and of $CaCl_2$ compared with $1.5{\sim}24hr$ of different shaking time. There were no loosely bound residues of paraquat.

  • PDF

Dynamic Threshold Determination Method for Energy Efficient SEF using Fuzzy Logic in Wireless Sensor Networks (무선 센서 네트워크에서 통계적 여과 기법의 에너지 효율 향상을 위한 퍼지논리를 적용한 동적 경계값 결정 기법)

  • Choi, Hyeon-Myeong;Lee, Sun-Ho;Cho, Tae-Ho
    • Journal of the Korea Society for Simulation
    • /
    • v.19 no.1
    • /
    • pp.53-61
    • /
    • 2010
  • In wireless sensor networks(WSNs) individual sensor nodes are subject to security compromises. An adversary can physically capture sensor nodes and obtain the security information. And the adversary injects false reports into the network using compromised nodes. If undetected, these false reports are forwarded to the base station. False reports injection attacks can not only result in false alarms but also depletion of the limited amount of energy in battery powered sensor nodes. To combat these false reports injection attacks, several filtering schemes have been proposed. The statistical en-routing filtering(SEF) scheme can detect and drop false reports during the forwarding process. In SEF, The number of the message authentication codes(threshold) is important for detecting false reports and saving energy. In this paper, we propose a dynamic threshold determination method for energy efficient SEF using fuzzy-logic in wireless sensor networks. The proposed method consider false reports rate and the number of compromised partitions. If low rate of false reports in the networks, the threshold should low. If high rate of false reports in networks, the threshold should high. We evaluated the proposed method’s performance via simulation.

Quality Changes of Orange Juice as Influenced by Clarification Methods (청징방법에 따른 오렌지주스의 품질특성)

  • Sohn, Kyoung-Suck;Seog, En-Ju;Lee, Jun-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.3
    • /
    • pp.378-382
    • /
    • 2006
  • Clarified orange juice was prepared using different clarification methods including centrifugation, enzyme treatment, ultrafiltration (UF), and combined treatment(CT). Effect of clarification methods as well as other quality parameters were investigated. Clarification was improved with increase in centrifugation speed and by lowering operating temperature. The optimum condition for centrifugation process was $5^{\circ}C$ and 10,000 rpm. UF and CT processes were very effective to produce clarified orange juice. The optimum condition of UF process was $45^{\circ}C$ and 150 kPa considering flux and turbidity CT did not significantly improve the clarification efficiency since most of the clarification was already achieved during UF process. $L^*$-values increased while $a^*$-values decreased significantly after clarification regardless of methods (p<0.05) Considering color, and recovering rate of vitamin C and soluble solids, UF process was superior than the other methods in producing clarified orange juice.

Control of Several Fungi in the Recirculating Hydroponic System by Modified Slow Sand Filtration (재순환 양액재배시 저속 모래여과기 시스템을 이용한 진균류 제어)

  • Park, K.W.;Lee, G.P.;Kim, M.S.;Lee, S.J.;Seo, M.W.
    • Horticultural Science & Technology
    • /
    • v.16 no.3
    • /
    • pp.347-349
    • /
    • 1998
  • Slow sand filtration was modified and applied for the determination of eliminating efficacy of various fungi and for recommending an easy approach to growers. After 1,500 liter filtration, Fusarium oxysporum was eliminated by several substrates such as activated charcoal (92.5% elimination), silica (90.8%), vermiculite (90.5%), sand (82.3%), perlite (50.4%), and hydroball (21.2%). Silica was able to eliminate several fungi by maximal ratio, which was corresponded to Fusarium oxysporum 120 cfu/mL. Collectotrichum lagenarium 98 cfu/mL. Phytophthora capsici 82 cfu/mL, Botrytis cinerea 62 cfu/mL, Pythium spp. 42 cfu/mL, and Sclerotinia ssp. 52 cfu/mL. In this case, the change of EC was minor and pH was maintained to about 7. In deep flow culture of 'Ddooksum Cheokchookmyeon' lettuce and 'Seokwang' tomato, silica-, activated charcoal-, and vermiculite-based filtration system successfully eliminated Fusarium oxysporum and Phytophthora capsici from the nutrient solution. As a result, these plants were not diseased by ten weeks after inoculation. With this system, growers can easily control the root-zone fungi in the recirculating hydroponic system.

  • PDF

Influencing Factors on Sensitivity of Pressure Decay Test for Membrane Damage Assessment (막 손상 측정을 위한 압력손실시험의 감도에 영향을 미치는 인자)

  • Lee, Yong-Soo;Kim, Hyung-Soo;Kim, Jong-Oh
    • Membrane Journal
    • /
    • v.27 no.4
    • /
    • pp.367-373
    • /
    • 2017
  • Pressurized membrane module systems, including hollow fiber type of Microfiltration (MF) and Ultrafiltration (UF) membranes are being increasingly used in drinking water treatment due to their high removal efficiency of pathogen. However, when fibers are damaged in pressurized membrane system, the pathogen will be able to penetrate the membrane. Therefore, it is essential to guarantee the regulatory requirements for water quality by an effective on-line or off-line condition integrity monitoring methods. Recently, pressure decay test (PDT) which is one of membrane integrity tests has been reflected to drinking water treatment plants using pressurized membrane module. In this paper, three different method were used to perform PDT and three different sensitivity values were analyzed through experiments. Three types of direct integrity test methods were applied to pressure feed side, filtrate side and bidirectional pressure decay test. The results of these experiments show that the sensitivity was increasing when the volume of pressurized gas was decreasing. The sensitivity is inversely proportional to the gas volume. Furthermore, it is desirable to increase pressure difference between feed side and permeate side in order to achieve higher sensitivity in the PDT by membrane damage.

Performance Evaluation of the Serially Connected Two Stage Fiber Filter for the RO Membrane Pre-treatment (2단 섬유여과 공정의 역삼투막 전처리 성능평가)

  • Bae, Si-Youl;Yun, Chang-Han;Kang, Dong-Hyo
    • Membrane Journal
    • /
    • v.19 no.2
    • /
    • pp.165-171
    • /
    • 2009
  • This study was for the evaluation of adaptability of the fiber filter as the pre-treatment of the RO membrane through SDI (Silt Density Index) measurement. The turbidity of raw waters were $0.76{\sim}1.6$ NTU for the effluent of sewer treatment plants (STP) and $2.2{\sim}3.3$ NTU for sea waters and 100 NTU for the surface water. The turbidity of the $2^{nd}$ filtrate of the serially connected two fiber filters was $0.07{\sim}0.25$ NTU and $SDI_{15}$ was $1.4{\sim}2.8$ when the 17% PAC was dosed $10{\sim}30ppm$. Results of the turbidity and $SDI_{15}$ of the $2^{nd}$ filtrate of the fiber filter which were compared with them of the lab scale MF/UF disc filter for the same STP's effluents showed that filtrate quality were enhanced with a little on the order of two stage fiber filter>MF>UF, the difference in $SDI_{15}$ was only $0.7{\sim}1.0$. So, the filtrate of the serially connected two stage fiber filter could satisfy $SDI_{15}$ 5.0 safely which was normally required for the feed water by the RO membrane supplier and it means the serially connected two stage fiber filter could be applied as the pre-treatment process of the RO membrane.

Clarification of Korean Tangerine Juice Using Microfiltration Membrane Process (미세여과 공정을 이용한 제주산 감귤 주스의 청징화)

  • Lee, Eun-Young;Woo, Gun-Jo
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.448-457
    • /
    • 1999
  • Citrus fruits are consumed worldwide due to their unique flavor and nutrition value. It is necessary to remove the haze material as well as to minimize the loss of major compounds such as organic acids, sugars, and ascorbic acid in membrane processes for clarification of juice. The objective of our research was to select the best membrane among one surface filter (Whatman No.4) and five microfiltration filters (GF/A, GF/D, GF/F, Gelman, and SM). Tangerine fresh blended with three times of water was partially clarified with 170 mesh followed by prefiltration in a Samduck filtration system. The best membrane was selected by measuring the amounts of major compounds in the permeates as well as the flux which were statistically analyzed with SAS program. The foulants on the membrane surface were observed by SEM. The flux of GF/A and GF/F decreased with time at probability 0.10. Gelman, SM, and GF/D maintained the stable flux. Gelman showed the highest total scores including nutritive value (the amounts of citrate, malate, and ascorbic acid) and purchasing need (brix and color). Therefore, the microfiltration membrane process was a very effective method in tangerine juice clarification and Gelman type A/E was proved to be the best membrane among the five microfiltration membranes.

  • PDF

Exhaust Emission Characteristics from Heavy-duty Diesel Engine applicable to Prime Propulsion Engine for Marine Vessels (선박 주 추진기관으로 사용가능한 대형 디젤엔진의 배기가스 특성 분석)

  • Lee, Hyung-Min;Park, Rang-Eun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.484-489
    • /
    • 2012
  • The objective of this work presented here was focused on analysis of particulate matter and nitrogen oxide characteristics in ESC test mode from heavy-duty diesel engine installed on-road vehicles applicable to prime propulsion engine for marine vessels. The authors confirmed that a large quantity particulate matter were emitted in high power density condition, nitrogen oxide characteristics were dependent on exhaust gas temperature. Particulate matters were reduced by 1/100~1/1,000 times in post DPF with test modes but filtration efficiency was decreased in the engine power fluctuation. In the case of the high speed and power condition, the exhaust level of particulate matters was increased according to increment of temperature of gas flowing into DPF. The orders of magnitude for particle concentration levels from the analysis of size distribution of particulate matters of test engine was different. Both emitting nano-sized particles below 100nm regardless of DPF and non-DPF.

Evaluation Model of the Automation Level of Smart Water Treatment Plant (스마트 정수처리장의 자동화수준 평가모델)

  • Son, Sang Hyeok;Kim, Sun Woo;LEE, Jong Yun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.05a
    • /
    • pp.285-288
    • /
    • 2021
  • 4차 산업혁명의 출현과 함께 스마트공장, 스마트시티, 스마트러닝 등이 등장하면서 스마트 물관리시스템과 그 평가지표의 연구개발이 주요 사회문제로 대두되고 있다. 따라서 본 논문에서는 스마트 물 관리시스템의 자동화 수준 평가지표를 제안하고자 한다. 그 세부 연구내용은 다음과 같다. 첫째, 기존의 CMM과 SPICE 소프트웨어 프로세스 평가모델과 스마트공장의 평가지표를 검토하고, 스마트 정수처리장의 개념을 살펴본다. 둘째, 제안하는 스마트 물관리시스템의 평가지표에는 정수장의 주요 공정에 따라 착수 공정, 약품투입 공정, 혼화·응집 공정, 침전 공정, 여과 공정, 소독 공정의 6개 평가영역으로 세분화 하였고, 각 평가영역별로 0에서 4까지의 5단계 평가수준으로 구분하여 제안하였다.

A Study on the Effect of Containment Filtered Venting System to Off-site under Severe Accident (중대사고시 격납건물여과배기계통(CFVS)적용으로 인한 사고영향과 결과 고찰)

  • Jeon, Ju Young;Kwon, Tae-Eun;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.244-251
    • /
    • 2015
  • The containment filtered venting system reduces the range of the contamination area around the nuclear power plant by strengthening the integrity of the containment building. In this study, the probabilistic assessment code MACCS2 was used to assess the effect of the CFVS to off-site. The accident source term was selected from a Probabilistic Safety Analysis report of SHINKORI 1&2 Nuclear Power Plant. The three source term categories from 19 STC were chosen to evaluate the effective dose and thyroid dose of residents around the power plant and the dose with CFVS and without CFVS were compared. The dose was calculated according to the distance from the nuclear power plant, so the damage scale based on the distance that exceeds the IAEA criteria for effective dose (100 mSv per 7 days) and thyroid dose (50 mSv per 7 days) were compared. The effective dose reduction rates of the STC-3, STC-4, STC-6 were about 95-99% in the whole range (0~35 km), 96-98% for the thyroid dose. There are similar results between effective dose and thyroid dose. After applying the CFVS, the damage scale that exceeds the effective dose criteria was about 1 km (mean). Especially, the STC-4 damage scale was decreased from 26 km (mean) to 1.2 km (mean) significantly. The damage scale that exceed the thyroid dose criteria was decreased to 2~3 km (mean). The STC-4 damage scale was also decreased significantly as compared to STC-3, STC-6 in terms of effective dose.