• Title/Summary/Keyword: 여과압

Search Result 64, Processing Time 0.029 seconds

Analysis of Photon Spectrum for the use of Added Filters using 3D Printing Materials (3D 프린팅 재료를 이용한 X-선 부가 여과 시 광자 스펙트럼에 대한 분석)

  • Cho, Yong-In;Lee, Sang-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.15-23
    • /
    • 2022
  • 3D printing technology is being used in various fields such as medicine and biotechnology, and materials containing metal powder are being commercialized through recent material development. Therefore, this study intends to analyze the photon spectrum during added filtration using 3D printing material during diagnostic X-ray examination through simulation. Among the Monte Carlo techniques, MCNPX (ver. 2.5.0) was used. First, the appropriateness of the photon spectrum generated in the simulation was evaluated through SRS-78 and SpekCalc, which are X-ray spectrum generation programs in the diagnostic field. Second, photon spectrum the same thickness of Al and Cu filters were obtained for characterization of 3D printing materials containing metal powder. In addition, the total photon fluence and average energy according to changes in tube voltage were compared and analyzed. As a result, it was analyzed that PLA-Al required about 1.2 ~ 1.4 times the thickness of the existing Al filter, and PLA-Cu required about 1.4 ~ 1.7 times the thickness of the Cu filter to show the same degree of filtration. Based on this study in the future, it is judged that it can be utilized as basic data for manufacturing 3D printing additional filters in medical fields.

A Study for Reduction of Radiation Dose in the Field of Diagnostic Radiology - A Point of Tube Voltage and Filtration - (진단방사선 영역에서 피폭선량 감소를 위한 기술적 연구 - 관전압과 부가여과판을 중심으로 -)

  • Ha, Ho-Young
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.89-97
    • /
    • 1992
  • X-ray quality is identified numerically by half value layer(H.V.L) and the HVL is affected by the kVp and the amount of filtration in the useful beam. X-ray quality evaluated by H.L.D is influenced by kVp and filtration. Author had several experiments with phantom in diameter of 8 cm normal adult chest, for reduction of radiation dose of the patients in diagnostic radiology and got some results. 1. H.V.L is increased the thicker the filter and the higher the kVp. 2. If the kVp is increased from 60 to 120, the skin dose can be reduced as 34%(Skin dose of 60 kVp with 4 mmAl filter : 100%). 3. If the 4 mmAl filter with 60 kVp is added to x-ray tube, skin dose can be reduced as 23% than no filter. 4. Therefore high kVp and filtration can increase output to input dose ratio and 120 kVp and 4 mmAl filter were most effective for reduction of patient dose in chest radiography.

  • PDF

Hydrostatic Pressure Effects on Physical Properties of Ultrafiltrated Skim Milk in the Presence of EGTA (EGTA를 첨가한 한외여과 탈지유의 물성에 미치는 초고압의 영향)

  • ;C. Kanno;T. Hagiwara
    • Food Science of Animal Resources
    • /
    • v.21 no.1
    • /
    • pp.32-37
    • /
    • 2001
  • The study investigated the effects of protein concentration, EGTA and strength of hydrostatic pressure on pH, viscosity and turbidity for ultra filtrated skim milk retentates. The results showed that hydrostatic pressure treatments up to 600 MPa did not affect the viscosity of skim milk, while the turbidity of skim milk increased at higher than 200 MPa. Addition of EGTA caused reduction in turbidity of skim milk, two times (2SR) and three times (3SR) concentrated skim milk retentates. Viscosity for 2SR and 3SR increased proportionally to the amount of EGTA, but viscosity of skim milk was not influenced by EGTA. High pressure treatment also did not cause any difference in viscosity and turbidity of skim milk. However, this treatment decreased viscosity and turbidity for 2SR and 3SR. In particular, 200 MPa treatment showed to induce a higher decrease in turbidity compared with 400 MPa.

  • PDF

Reverse Osmosis Treatment of Swine Wastewater with Various Pretreatment Systems (축산 폐수의 전처리 방법과 역삼투압 처리)

  • Park, Soon Ju;Kim, Moon Il;Kim, Do Yun;Chang, Ho Nam;Chang, Seung Teak
    • Clean Technology
    • /
    • v.9 no.2
    • /
    • pp.49-55
    • /
    • 2003
  • The generation of livestock wastewater in Korea amounts to $130,000m^3/day$, 0.43% of the total waste water volume, but which corresponds to 8.6% of total BOD loading. Furthermore this wastewater contains a large amount of nitrogen and phosphorus that are major causes of eutrophication in rivers and lakes. The average volume of livestock wastewater in a Korea's single farm is only $2.5m^3/day$, which necessitates development of a simple and economical process for the removal of nitrogen and phosphorus. Introduction of filtration method removes more than 90% of suspended solids. Subsequent application of reverse osmosis removes more then 95% of total nitrogen and phosphorus in the wastewater. The effluent of this treatment will yield less than 200 mg/L of total nitrogen and 1 mg/L of total phosphorous, which are lower than 260 mg/L of total N and 50 mg/L of total P, the regulation values of Ministry of Environment, Korea. Treating $2m^3/day$ of livestock wastewater was found to be feasible with the application of filtration and reverse osmosis and the electricity requirement was estimated to be about 30 Kwh/month.

  • PDF

Properties of Semen and Sperm Motility in Black Seabream, Acanthopagrus schlegeli (감성돔, Acanthopagrus schlegeli 정액의 특성과 정자의 운동성)

  • Chang Young Jin;Lim Han Kyu;Kho Kang Hee
    • Journal of Aquaculture
    • /
    • v.8 no.3
    • /
    • pp.149-157
    • /
    • 1995
  • In order to obtain the basic knowledges concerned to the semen preservation of aquacultural fishes, studies on the physical and chemical properties of semen, and sperm motility with the different osmotic pressures making by adding $Na^+,\;K^+,\; Mg^{++},\;and\;Ca^{++}$ to artificial seawater (ASW) were conducted in black seabream, Acanthopagrus schlegeli. Average semen volume per fish in one strip was 1.97ml and sperm concentration was $2.33\pm1.30\times10^{10}$ sperm/ml. Spermatocrit and pH of semen were $90.6\pm5.0\;and\;8.3\pm0.1$, respectively, Osmotic pressures of rearing seawater, seminal fluid and plasma were $939\pm24,382\pm70\;and\;342\pm77$ mOsm/l, and $Na^+,\;K^+$ and $Cl^-$ concentrations of seminal fluid were $169.5\pm4.5,\;4.9\pm2.2,\;156.0\pm2.0\;mM/l$, respectively. When semen were diluted by using $Na^+,\;K^+,\;Mg^{++}\;and\;Ca^{++}$ free ASW, only $Na^+$ free ASW had no sperm motility. As raising osmotic pressure graduary by addition of 1M NaCl to the $Na^+$ free ASW, spermatozoa showed the high motilities in 457-1128 mOsm/l, but the low motilities in 1398-1736 mOsm/l. In the case of same treatments with 1M of KCl, $MgC1_2\;and\;CaC1_2$ to the $K^+,\;Mg^{++}\;and\;Ca^{++}$ free ASW, spermatozoa revealed the high motilities in $904\~1434,\;818\~1175\;and\;956\~1343$ mOsm/l, respectively.

  • PDF

Comparison Evaluation of Image Quality with Different Thickness of Aluminum added Filter using GATE Simulation in Digital Radiography (GATE 시뮬레이션을 사용한 알루미늄 부가필터 두께에 따른 Digital Radiography의 영상 화질 비교 평가)

  • Oh, Minju;Hong, Joo-Wan;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.81-86
    • /
    • 2019
  • In X-ray image, the role of filtration through the filter is to reduce the exposure of the patient by using photon which is useful in formation of the image, and at the same time, enhance the contrast of the image. During interaction between photon and object, low energy X-rays are absorbed from the site of a few cm of the first patient's tissue, and high energy X-rays are the one which form the image. Therefore, the radiation filter absorbs low energy X-ray in order to lower the exposure of the patient and improve the quality of the image. The purpose of this study is to compare the effect on the image quality by differences of added filter through simulation image and actual radiation image. For that purpose, we used Geant4 Application for Tomographic Emission (GATE) as a tool for Monte Carlo simulation. We set actual size, shape and material of Polymethylmethacrylate (PMMA) Phantom on GATE and differentiated the parameter of added filter. Also, we took image of PMMA phantom with same parameter of added filter by digital radiography (DR). Than we performed contrast-to-noise ratio (CNR) evaluation on both simulation image and actual DR image by Image J. Finally, we observed the effect on image quality due to different thickness of added filter, and compared two images' CNR evaluation's transitions of change. The result of this experiment showed decreasing in the progress of CNR on both DR and simulation image. It is ultimately caused by decreasing in contrast on image. In theory, contrast decrease with kVp increased. Given that condition, this study found out that filter makes not only decreasing total dose by absorbing low energy of X-ray, but also increasing average energy of X-ray.

Estimation of Stocking Density using Habitat Suitability Index and Ecological Indicator for Oyster Farms in Geoje-Hansan Bay (서식적합도와 생태지표를 이용한 거제한산만 굴양식장의 입식밀도 산정)

  • Cho, Yoon-Sik;Lee, Won-Chan;Hong, Sok-Jin;Kim, Hyung-Chul;Kim, Jeong-Bae;Park, Jung-Hyun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.3
    • /
    • pp.185-191
    • /
    • 2012
  • Most of Korean farms have been developed in the semi-closed bay, and its position is very vulnerable to the coastal contamination due to the long term and the high density. So, mariculture management is very essential for the sustainable aquaculture. Some of the specific ways would be the assessment of the optimal stocking density for mariculture management zone and this has to consider both the suitable site selection and the assessment of ecological carrying capacity. Habitat suitability index(0.0 totally unsuitable habitat, 1.0 optimum habitat) and ecological indicator(Filtration pressure indicator) was used to assess the stocking density for oyster farms in Geoje-Hansan Bay. Geoje Bay showed the higher habitat suitability index value 0.75 than Hansan Bay 0.53, indicating that Geoje Bay is more suitable for oyster farming. Ecological indicator showed different stocking density according to the coastal characteristics in Geoje-Hansan Bay. Consequently, it is desirable that the stocking density in Geoje Bay should reduce average 40% and Hansan Bay, average 60% than present, in order to meet the ecological carrying capacity. The assessment of the stocking density could solve various problems such as the coastal contamination, environmental aggravation and the productivity decrease and this study could be a scientific basis to establish the policies for mariculture management.

Reuse and Concentration of Sewage by Forward Osmosis Using Fertilizer as Draw Solution (비료 유도용액의 정삼투를 이용한 하수의 재이용 및 농축)

  • Kim, Seung-Geon;Lee, Ho-Won
    • Applied Chemistry for Engineering
    • /
    • v.30 no.1
    • /
    • pp.122-131
    • /
    • 2019
  • In order to reuse and concentrate the sewage, a forward osmosis using fertilizer as draw solution was applied. Sewage-1, which is the supernatant after settling for 30 minutes for the primary settling basin influent, and Sewage-2, which is the supernatant after settling for 30 minutes for the effluent, and Sewage-3, which is the filtrate filtered through a $1{\mu}m$ cartridge filter for the effluent were tested. Eight draw solutions of $NH_4H_2PO_4$, KCl, $KNO_3$, $NH_4Cl$, $(NH_4)_2HPO_4$, $NH_4NO_3$, $NH_4HCO_3$, and $KHCO_3$ were used in consideration of osmotic pressure, solubility and pH. In the case of Sewage-3, the permeate flux was almost similar to that of the discharge water of the sewage treatment plant, and was larger than that of Sewage-1 and Sewage-2. $NH_4H_2PO_4$ was the smallest, and $NH_4NO_3$ was the largest in the specific reverse solute flux. $NH_4H_2PO_4$ was found to be most useful for the reuse and concentration of sewage because it contains nitrogen and phosphorus, which are the major components of fertilizer, as well as low specific reverse solute flux. When $NH_4H_2PO_4$ was used as the draw solution, the concentration factor after 24 hours for Sewage-3 was 1.72.

Progress in Nanofiltration-Based Capacitive Deionization (나노여과 기반 용량성 탈이온화의 진전)

  • Jeong Hwan Shim;Rajkumar Patel
    • Membrane Journal
    • /
    • v.34 no.2
    • /
    • pp.87-95
    • /
    • 2024
  • Recent studies explore a wide array of desalination and water treatment methods, encompassing membrane processes such as reverse osmosis (RO), nanofiltration (NF), and electrodialysis (ED) to advanced capacitive deionization (CDI) and its membrane variant (MCDI). Comparative analyses reveal ED's cost-effectiveness in low-salinity scenarios, while hybrid systems (NF-MCDI, RO-NF-MCDI) show improved salt removal and energy efficiency. Novel ion separation methods (NF-CDI, NF-FCDI) offer enhanced efficacy and energy savings. These studies also highlight the efficiency of these methods in treating complex wastewater specific to various industries. Environmental impact assessments emphasize the need for sustainability in system selection. Additionally, the integration of microfabricated sensors into membranes allows real-time monitoring, advancing technology development. These studies underscore the variety and promise of emerging desalination and water treatment technologies. They provide valuable insights for enhancing efficiency, minimizing energy usage, tackling industry-specific issues, and innovating to surpass conventional method limitations. The future of sustainable water treatment appears bright, with continual advancements focused on improving efficiency, minimizing environmental impact, and ensuring adaptability across diverse applications.

Treatment of AP Solutions Extracted from Solid Propellant by NF/RO Membrane Process (NF/RO 멤브레인 공정을 적용한 고체추진제에서 추출된 암모늄 퍼클로레이트 (AP) 처리 연구)

  • Kong, Choongsik;Heo, Jiyong;Yoon, Yeomin;Han, Jonghun;Her, Namguk
    • Membrane Journal
    • /
    • v.22 no.4
    • /
    • pp.235-242
    • /
    • 2012
  • Ammonium perchlorate (AP) is primarily derived from the process of liquid incineration treatment when dismantling a solid rocket propellant. A series of batch dead-end nanofiltration (NF) and reverse osmosis (RO) membrane experiments were conducted to explore the retention mechanisms of AP under various hydrodynamic and solution conditions. Low levels of silicate type of siloxane had been detected through the GC/MS and FTIR analysis of liquid solutions extracted from solid ammonium perchlorate composite propellant (APCP). It is indicated that NF/RO membranes fouling in the presence of APCP was mainly attributed to the AP interactions because the concentration of silicate type of siloxane was negligible compared to that of AP. The osmotic pressure of AP was presumably resulted in the flux declines ranging from 13 to 17% in the case of the application of low-pressure (551 and 896 kPa for NF and RO) compared to those in application of high-pressure. The retention of AP by NF/RO membranes significantly varied from approximately 10 to 70% for NF and 26 to 87% for RO, depending on the operating and solution water chemistry conditions. The results suggested that retention efficiency of AP was fairly increased by reducing concentration polarization (i.e. application of low-pressure and stirring speed of 600 rpm) and increasing the pH of a solution. The result of this study was also consistent with the previous modeling of 'solute mass transfer of NF/RO membranes' and demonstrated that hydrodynamic and solution water chemistry conditions are to be a key factor in the retention of AP by NF/RO membranes.