• Title/Summary/Keyword: 여과량

Search Result 787, Processing Time 0.031 seconds

Enhanced Dewaterability of Sewage Sludge by a Natural Inorganic Conditioner (무기개량제를 이용한 하수슬러지의 탈수능 개선)

  • Nam, Se-Yong;Kim, Jeong-Ho;Kim, Sang-Hyoun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.10
    • /
    • pp.651-655
    • /
    • 2012
  • This study aimed to investigate the effect of an inorganic conditioner composed of natural inorganic materials on the dewaterbility of sewage sludge and compare the performance with those of conventional organic polymeric conditioners. A dosage of 2.0 mg inorganic conditioner/g sludge TS decreased time to filter test (TTF), specific resistance to filtration (SRF), water content of dewatered sludge cake, turbidity from 146 to 41 sec, from $8.3{\times}10^{14}$ to $2.4{\times}10^{14}$ m/kg, from 82.1 to 77.1%, from 112 to 61.1 NTU, respectively, which was compatible to the conventional cation organic polymer. An inorganic conditioner would be used in sewage sludge treatment as a suitable alternative conditioner. Regression analysis showed a strong relationship among TTF, SRF, and water content.

Preparation and Characterization of Nanofiltration Membranes for Recovery of Organic Acids from Fermentation Broth (발효액 내 유기산의 효과적 회수를 위한 나노여과 분리막)

  • Hwang, Yoon Sung;Cho, Young Hoon;Park, Ho Bum
    • Membrane Journal
    • /
    • v.23 no.4
    • /
    • pp.304-311
    • /
    • 2013
  • In fermentation-separation processes, nanofiltration membrane processes can be used to separate organic acid and other byproducts such as sugars and proteins. In this study, new nanofiltration membranes were prepared to improve organic acid permeability during the separation processes of fermentation broth. Positively charged nanofiltration membrane was introduced to reduce lactic acid rejection by electrostatic attraction between lactic acid and nanofiltration membrane. Newly fabricated nanofiltration membranes were prepared by grafting cationic polyelectrolyte, PEI, on membrane surface. Thenanofiltration membranes showed positively charged surface potential. As a result, lactic acid rejection was remarkably reduced while the rejection of glucose was not changed significantly.

Transport of Colloids and Contaminant in Riverbank Filtration (강변여과에서 콜로이드 물질과 오염물의 거동에 관한 연구)

  • Lee Sang-Il;Kim Dae-Hwan;Lee Sang-Sin;You Sang-Yeon
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.6 s.167
    • /
    • pp.511-520
    • /
    • 2006
  • Riverbank filtration is a natural process, using alluvial aquifers to remove contaminants and pathogens in river water for the production of drinking water. In Korea, most of the drinking water is supplied by surface water in-take. However, maintaining the quality of the drinking water becomes more and more difficult due to the increase of contamination. In riverbank filtration, the understanding of contaminant transport is an important task for the production of high quality drinking water and for the maintenance of facilities. In this paper, the transport behavior of hydrophobic organic contaminants is investigated when contaminants coexist with dissolved organic matter (DOM) and bacteria. In the developed model, the aquifer is thought of as a four phase system: two mobile colloidal phases, an aqueous phase, and a stationary solid matrix phase. The model equations are solved numerically for various situations. Results indicate that the presence of colloidal matters can enhance the mobility of contaminant significantly and that partitioning coefficients play an important role in the process.

Effect of Electrical Field on Ultrafiltration for Protein Separation (단백질 분리를 위한 한외여과에서의 전기장의 영향)

  • Koo Ja-Kyung;Son Dongho;Lee Yunhee;Cho Namjun;Jang Dong Il
    • Membrane Journal
    • /
    • v.15 no.2
    • /
    • pp.132-140
    • /
    • 2005
  • The effects of electrical fields on the efficiencies in ultrafiltration for protein separation were explored. The experiments were proceeded under constant transmembrane pressure (THP) using protein (albumin and lysozyme) solutions. For ultrafiltrations, cellulose membranes with molecular weight cut off (MWCO) 30 kDa were used. It is found that electrical field improved the filtration flux of albumin solution. The electrical field showed another interesting effect for filtration of protein solution. Depending on the electrical charges of protein molecules, the electrical field promoted or hindered the permeation of proteins through membranes. With the effect of electrical field, not only the permeation flux but also the selectivity of ultrafiltration could be improved.

Use of a Combined Photocatalysis/Microfiltration System for Natural Organic Matter Removal (광촉매 반응과 침지형 정밀여과를 이용한 자연산 유기물의 제거)

  • 추광호;박경원;김문현
    • Membrane Journal
    • /
    • v.14 no.2
    • /
    • pp.149-156
    • /
    • 2004
  • This work focused on the degradation of natural organic matter (NOM) present in lake water using a combined pkotocatalysisimicrofiltration (MF) process. The system performances were investigated in terms of organic removal efficiency and membrane permeability. The addition of iron oxide particles (IOP) into the photocatalytic membrane reactor improved initial NOM removal by sorption, but during photocatalysis the removal efficiency was reversed, probably due to the scattering of UV light by IOP. The modification of TiO$_2$ surfaces by IOP deposition was conducted to enhance the photocatalytic NOM removal efficiency. A minimal amount of Impregnation of IOP on TiO$_2$ surfaces was required to prevent the light scattering effect as well. The coating of MF membranes with IOP helped to improve the NOM removal efficiency while sorbing NOM by IOP. Regardless of tile operating conditions and particles addition examined, no significant fouling was occurring at a flux of 15 L/$m^2$-h during entire MF operation.

Effects of Fouling Reduction by Intermittent Aeration in Membrane Bioreactors (MBR에서 간헐포기에 의한 오염저감 효과)

  • Choi, Youngkeun;Kim, Hyun-Chul;Noh, Soohong
    • Membrane Journal
    • /
    • v.25 no.3
    • /
    • pp.276-286
    • /
    • 2015
  • The effects of relaxation and backwashing on fouling in ultrafiltration were investigated using full-scale membrane bioreactors (MBRs) which operated at a constant flux of 30 LMH. This paper also estimated the feasibility of using intermittent aeration strategies for minimizing the hydraulic resistance to filtration in comparison with the continuous aeration for running MBRs. Multiple cycles of filtration (14.5 min each) and relaxation (0.5 min each) were repeated. Similarly, a backwash was conducted by replacing a relaxation after each filtration cycle for the comparative performance test. The attached cake thickness on the membrane rapidly increased, caused by subsequent no aeration leading to easier combining with gel layer and the formation of heterogeneous layer on the membrane surface. During periodic backwashing, it is expected that gel and thin cake layer might sufficiently be removed by heterogeneous layer. After periodic backwashing, subsequent cake layer formation during time of no aeration was rapid than frequent no aeration, acting as a prefilter and preventing further irreversible fouling. Based on the Pearson correlation analysis, overall period fouling (dTMP/min) and average of all cycles (dTMP/min) were strongly correlated with the on-off period of aeration for operating MBRs.

A study on the application of modified hydraulic conductivity to consider turbid water for open-cut riverbed infiltration process: numerical modeling approach (개착식 하상여과에서 탁수를 고려한 수정 투수계수 적용 연구: 수치모델링을 통한 접근)

  • Yang, Jeong-Seok;Kim, Il-Hwan;Jeong, Jae-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.9
    • /
    • pp.741-748
    • /
    • 2016
  • Laboratory scale model was constructed for open-cut riverbed infiltration experiment and four kinds of media were selected, medium sand, sand, volcanic rock, and gravel, for the experiment. Hydraulic conductivity for each medium and flow rate from the collecting pipe with functional screen were estimated from the experiment. Modified hydraulic conductivity scenarios considering turbid water (30~50 NTU) were applied in Visual MODFLOW modeling to analyze the effects of turbid water on the flow rate. Twenty-two scenarios were generated considering prticles in turbid water and applied to each medium cases in MODFLOW modeling. The minimum error was occurred when the gravel medium had 20% less hydraulic conductivities for the third layer-depth from the top and clay particles in turbid water might play a role in adsorption process to the surface of volcanic rock (2~5 mm). For medium sand case the error was also quite small when the mediumhas 5% less hydraulic conductivities for the second layer-depth from the top.

Study of particle laden flows around turbine cascade (터빈 익렬 주위에서의 부유 입자 유동 해석)

  • 김완식;조형희
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.10-10
    • /
    • 1998
  • 본 연구에서는 제트 추진 기관의 터빈 익렬에서의 유동과 대기 중에 부유되어 있는 입자 또는 연소 생성물들이 제트엔진 내부로 유입될 경우 이에 따른 압축기 및 터빈 날개의 마모 및 충돌 부위를 예측하기 위하여 수치해석을 수행하였다. 일반적으로 각종 항공기의 추진 기관용 가스 터빈 엔진은 대기중에 부유되어 있는 각종 입자들의 영향을 받게 된다. 특히, 확산 지역을 통과하는 항공기나 먼지 입자 부유물이 많은 공업지대 또는 사막지역을 비행하는 항공기의 경우는 모래 알갱이, 먼지 및 연소 입자의 직접적인 영향을 받아 각 요소들에 심각한 부식 및 마모가 발생됨으로써 성능 저하 및 냉각 통로의 막힘, 압축기와 터빈 날개의 손상 등이 예측되어진다. 특히 항공기용 추진 기관은 엔진 입구에 유입 공기를 정화하기 위한 여과장치의 설치가 불가능하며, 자동차용 가스터빈 엔진의 경우는 여과 장치를 부착하여도 미세한 입자들이 여과 장치에 여과되지 않고 엔진 내부로 침투하게 되므로 치명적인 손상이 예상된다. 이러한 손상들은 초기에는 미세하게 발생하지만, 손상 정도가 점점 누적됨에 따라서 항공기의 안전 운전에 심각한 위험 요소로서 작용할 수 있으며, 경제적으로도 기관의 유지 보수비용의 증가를 가져올 수 있다. 따라서 압축기에 화산재 또는 대기중에 부유되어 있는 금속 입자나 먼지입자 등이 유입되었을 경우, 압축기 날개의 손상 부위와 정도를 예측하는 것이 필요하다. 따라서 본 연구에서는 Lagangian방법을 적용하여 압축기 날개위의 부유 입자 충돌 부위를 예측하고, 설계 시 이를 보완할 수 있는 기준을 제시하였다. 아울러 설계 입구각과 크게 벗어난 유동의 유입시에 발생되는 박리 현상과 이에 따른 입자의 유동 및 날개의 입자 접착 부위를 예측하였다. 본 연구에서는 여러 크기의 입자(다양한 Stokes 수)들을 주어진 속도에서 유선을 따라 압축기 입구에서 압축기 유로로 여러 위치에서 부유 시켜서 그 입자들의 궤적 및 충돌, 점착 위지를 고찰하고, 정량적인 충돌량을 해석하기 위하여 입자 충돌 계수를 정의하여 압축기 날개 표면의 충돌특성을 알아보았다. 이러한 예측을 통하여 압축기 날개 표면의 충돌 부위를 예측하고, 날개의 표면을 코팅하는 등 보호 개선책을 제시할 수 있고, 연소의 반응물 입자가 터빈 날개에 충돌하여 발생되는 날개 표면의 파손, 냉각 홀의 막임, 연소 입자의 점착 부위 등을 예측하여 보완책을 준비할 수 있도록 하였다.

  • PDF

A Method to Improve Energy Efficiency Using a Function that Evaluate the Probability of Attempts to Verify a Report at Intermediate Node in USN (USN에서 중간 노드에서의 보고서 검증 시도 확률 평가 함수를 이용한 에너지 효율 향상 기법)

  • Lee, Hyun-Woo;Moon, Soo-Young;Cho, Tae-Ho
    • Journal of the Korea Society for Simulation
    • /
    • v.20 no.4
    • /
    • pp.21-29
    • /
    • 2011
  • Wireless sensor nodes operate in open environments. The deployed sensor nodes are very vulnerable to physical attacks from outside. Attackers compromise some sensor nodes. The compromised nodes by attackers can lead to false data injection into sensor networks. These attacks deplete the limited energy of sensor nodes. Ye et al. proposed the Statistical En-Route Filtering (SEF) as a countermeasure of the attacks. The sensor node in SEF examines the event reports based on certain uniform probability. Thus, the same energies are consumed in both legitimate reports and false reports. In this paper, we propose a method that each node controls the probability of attempts to verify a report to reduce energy consumption of sensor nodes. The probability is determined in consideration of the remaining energy of the node, the number of hops from the node to SINK node, the ratio of false reports. the proposed method can have security which is similar with SEF and consumes lower energy than SEF.

Development of biological processes for the removal of assimilable organic carbon from potable water (음용수로부터 동화성 유기물질의 제거를 위한 생물학적 공정개발)

  • 이민규;감상규
    • Journal of Life Science
    • /
    • v.10 no.1
    • /
    • pp.14-21
    • /
    • 2000
  • The experiments were performed using both batch and continuous column reactors. Batch biodegradation studies were performed under aerobic conditions to determine the biodegradable fraction of the natural organic matter (NOM) source. NOM source was evaluated for its biodegradability at three different UV irradiation conditions and compared to its biodegradability without UV irradiation. In continuous experiments, system operating parameters of empty bed contact time (EBCT), recycle ratio, and influent concentration affected the extent of biofiltration in the biofilters. The effluent UV254/DOC ratios fro the biologically active columns were consistently lower than the influent values, which indicated that the dissolved organic carbon (DOC) removed by biodegradation was not a significant part of the UV-absorbable material. The increase in UV254/DOC ratio was caused by the DOC decrease across the biofilter because there was essentially no difference between the feed and effluent UV254 absorbance values over time. The results of this research showed that biofiltration was an effective method for removing the biodegradable fraction of NOM from water supplies.

  • PDF