• Title/Summary/Keyword: 에어컨 실외기

Search Result 38, Processing Time 0.028 seconds

Optimal Design of the Pipe Configuration of an Air Conditioner Outdoor Unit Considering Vibration Characteristics (진동특성을 고려한 에어컨 실외기 배관의 최적설계)

  • Kim, Jun-Hyung;Park, Chang-Bae;Choi, Soo-Yong;Min, Je-Hong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.655-660
    • /
    • 2004
  • The pipes in the outdoor unit of an air conditioner are designed to reduce the vibration effect of the compressor. Three-dimensional structure of the pipe could provide various design choices and the resultant vibration characteristics of the outdoor units. A design program has been developed for an eligible parametric study of pipe design and automatic vibration analysis using commercial software, I-DEAS, and its macro. Optimal design of pipe configuration has been performed using the commercial software, iSIGHT. The optimized design shows 70 percents improvement in the vibration characteristics of the outdoor unit of an air conditioner.

  • PDF

Development of a Cycle Simulation Program for Multi-Airconditioning Systems using R410A (R410A를 사용하는 멀티에어컨 시스템을 위한 사이클 시뮬레이션 프로그램 개발)

  • Kim, Young-Jae;Park, In-Sub;Kim, Hak-Hee;Yoon, Baek;Gil, Sung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.3
    • /
    • pp.210-215
    • /
    • 2002
  • In this study, the computer program called Multi_Cycle, which simulates the steady-state performance (coefficient of performance, capacity, power consumption and etc.) of multi- airconditioning systems using R410A, was developed. In order to validate the simulation program, a series of case studies were carried out. The Multi_Cycle consists of several subroutines for simulating indoor units. outdoor unit, compressor, and expansion devices. and for estimating the thermodynamic and transport properties of the refrigerants and moist air. It would appear to be advantageous to use the Multi_Cycle for a performance analysis when considering various kinds of refrigerants and the complex operating conditions of each unit making up the multi-airconditioner cycle. Moreover, the Multi_Cycle would seem to be useful tool in optimizing a multi-airconditioning system and establishing economical and efficient operating conditions in the multi-airconditioner cycle. In the present study, the Multi_Cycle was programmed with Digital Visual Fortran for the main simulation code and Visual Basic for- the graphic user interface.

  • PDF

Temperature characteristics of condenser and evaporator of Air-conditioner applying variable capacity compressor under cooling condition (가변용량 압축기를 적용한 에어컨의 냉방운전 시 응축 및 증발온도 특성)

  • Kwon, Young-Chul;Chun, Chong-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1325-1331
    • /
    • 2007
  • In order to investigate the cooling capacity of an air-conditioner applying a variable capacity compressor and the temperature characteristics on a condenser and an evaporator, the experiment on the operation characteristics of the air-conditioner was performed along a compressor operation ratio and an indoor/outdoor temperatures, under a cooling operation mode. The system characteristics were measured by the psychrometric calorimeter. The cooling capacity increased with decreasing the outdoor temperature and increasing the indoor temperature. Also, it increased with increasing the compressor operation ratio. The temperature of the condenser was more sensitive for the variation of the outdoor temperature and the temperature of the evaporator was more sensitive for the variation of the indoor temperature. The operation characteristics of the cycle used in this present were also analyzed by a pressure-enthalpy chart.

  • PDF

Improved Performance Through Air Conditioner Outdoor Fan Airflow Increase and Relative Cost Reduction (에어컨 실외기 풍량증가를 통한 성능 향상 및 상대적 원가절감)

  • Kim, Jae-Yeol;Choi, Seung-Hyun;Kim, Sung-Hyun;Ki, Suk-Ho;Yoon, Sung-Un
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.4
    • /
    • pp.570-574
    • /
    • 2012
  • Spread of household air conditioning system is continued to be increased. Axial fan in the external unit of air conditioning system is for ventilation and air supplying unit, and the related products have been widely adopted as household electronics, automobile engine, big sized blower in factory, tunnel, and subway. In this study, commercial 3-winged propeller fan is modified to shape and modified to 2-winged fan for the airflow increase and cost reduction. Using 3D modelling, the fan shape is modified, and analysis flow is adopted to provide the way to airflow increase and reduce cost while maintaining the same wind capacity.

Environmental Noise Assessment of Indoor and Outdoor Units of Air-conditioner (에어컨 실내기의 방사소음과 실외기의 투과소음에 의한 환경소음 예측)

  • 장서일;최진권;손진희;모진용;구형모
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.1
    • /
    • pp.40-47
    • /
    • 2003
  • This study was conducted to determine the sound paths and transmitted sound level in house. An air-conditioner system was selected a typical sound source. The measured transmission loss data shows that the apertures have an significant effect on the transmitted noise and comparable with the existing theoretical data. Therefore the complex aperture was substitute to quantitative apertures approximately. An effective simulation method, ray tracing and mirror image source method, was employed in the prediction of transmitted sound level. The measured results were efficiently reflected on the simulated results. So it is important that measuring the acoustic parameter prior to the prediction of the transmitted sound level in the house.

A Frost-less Heat Pump

  • 황윤제;이원희
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.31 no.3
    • /
    • pp.53-58
    • /
    • 2002
  • 대부분의 가정용 냉난방겸용 공기조화기(히트펌프)는 실외온도가 $5^{\circ}C$ 이하이고, 습도가 높은 저온고습조건에서 난방운전을 하면 열교환기 표변에 서리가 발생하고, 이로 인해 시스템의 성능이 떨어지게 된다. 이를 방지하기 위하여 어느 일정 조건이나 시간이 되면 히트펌프는 제상운전을 하게 되는데, 보통의 가정용 히트펌프의 경우 난방운전도중에 사이클을 냉방운전으로 전환하여 실외 열교환기의 온도를 높여 줌으로써 제상을 하는 방식 (Cycle reversing method)을 사용하고 있다. 이 방식은 부가적인 제상회로플 구성하 거나 히터를 첨가하는 등의 재료비 증가 없이 제상을 수행한다는 장점이 있으나, 시스템의 에너지 효율 측면에서 불리할 뿐만 아니라, 소비자의 입장에서 보면 제상운전이 진행되는동안에 따뜻한 바람이 공급되지 않아 쾌적한 공조를 제공받지 못한다는 단점이 있다. 본 자료에서는 먼저 제상방석에 관하여 그 종류와 특정을 알아보고, 최근에 진행되고 있는 착상 지연기술 중 어큐물레이터 내에 히터를 설치하는 방식(Viung C. Mei, et al., 2002, ASHRAE TRANSSACTIONS, V 108, Pt. 1)에 대하여 소개하고자 한다.

  • PDF

Evaluation of the Outdoors side Air-conditioner Sound using Time Signal Analysis (Time signal 분석을 통한 에어컨 실외기의 소음 평가에 대한 연구)

  • 한형석;구형모;모진용;박득용;김주환
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.330-332
    • /
    • 2003
  • In this paper, It is introduced new sound quality method, FI(Fluctuation Index) and the example applied Outdoors side Air-conditioner noise evaluation. Because FI is applied with very simple algebraic calculation algorithm, it can be applied some other application without spending high time and cost.

  • PDF

Study on Fire Risk of Air Conditioner through Fire Cases (화재사례를 통한 에어컨의 화재위험성 연구)

  • Choi, Seung-Bok;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.70-77
    • /
    • 2017
  • As the quality of live gets better, the frequency of using air conditioner is along drastically increasing. On that matter, setting up measures of preventing increasing fire cases has been required. 43,413 fire cases occurred in last 2016, the cases occurred by electricity account for about 20%(8,655 cases). Among the electricity cases, the amount of cases occurred with air conditioner issues covers 1.5%; causes of the fire incidents vary, including incomplete contacts, short circuits, tracking, and such. In this study, we intend to investigate the case of ignition at the connection point where the power cord connected to the outdoor unit is arbitrarily connected during the air conditioner installation process, and to propose preventive measures against the cause in order to reduce the damage of life as well as the property from electric fire incidents.

Noise & Vibration Evaluation and Analysis for Propeller Fan System of Air Conditioner Outdoor Unit (에어컨 실외기 프로펠러 홴계의 진동소음 평가 및 해석)

  • Park, Deug-Yong;Mo, Jin-Yong;Lee, Jin-Kyo;Koo, Hyoung-Mo;Choi, Weon-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1405-1409
    • /
    • 2000
  • The electro-magnetic noise generated from fan-driving motor is one of important items in view of abnormal noise which affect the quality of air conditioner noise. The electro-magnetic noise of the outdoor unit is identified by the serial experiments for related parts, whose effects are verified to give proper measures for reduced noise level. The weight of fan appears to be the most important factor, and the stiffness of the frame, such as motor bracket is shown to be important also.

  • PDF

Source Identification and Reduction of Noise for the Outdoor Unit of Room Air Conditioner (에어컨 실외기의 소음원 규명 및 소음저감)

  • 서상호;임금식;이내영;진심원
    • Journal of KSNVE
    • /
    • v.8 no.6
    • /
    • pp.1043-1052
    • /
    • 1998
  • The noise sources in the outdoor unit of RAC are identified by the sound intensity method. The main noise sources are compressor noise and fluid noise which is caused by the fan. heat exchanger and shroud. First. the fluid noise is reduced through the design of new fan and shroud. reduction of the system resistance by rearrangement of heat exchanger. and optimization of the complex parameter between the fan and shroud. Next, in order to reduce the compressor noise, the new shape of compressor mount and sound-proof material was applied. As a result, the overall noise was reduced by 4∼5dB (A).

  • PDF