• Title/Summary/Keyword: 에어리프트

Search Result 6, Processing Time 0.019 seconds

Performance of Airlift Pumps for Water Circulation and Aeration (물 순환 및 에어레이션용 에어리프트 펌프의 성능)

  • OH Se-Kyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.25 no.6
    • /
    • pp.529-537
    • /
    • 1992
  • Airlift pumps were tested to evaluate their pumping and aeration capacities. The pumps were 34.5 inch long made of 2, 3, 4 and 6 inch nominal diameter PVC pipes. An one hp air blower was used to supply the air. The air-flow rate was measured by an anemometer type air-flow meter and air pressure was level changes in a water tank from which water was pumped. Aeration by the pumps was tested by the standard aeration test method with the center of pump outlet positioned 3 inches above water surface. Oxygen concentrations in water were measured to determine aeration rate. As pumping head increased by water level draw-down in the tank water flow decreased while air flow increased. The reduction rate of water flow was higher with 4 and 6-inch pumps. Small pumps showed very minor changes in the reduction. Aeration rates were similar among 3, 4, and 6 inch pumps. With one hp air blower 6-inch pump at the minimum pumping head achieved the best performance in terms of water circulation.

  • PDF

A Study on Performance Characteristics of Small Airlift Pump (소형 에어리프트 펌프의 성능특성에 관한 연구)

  • Oh, S.K.;Lee, G.Y.
    • Journal of Power System Engineering
    • /
    • v.4 no.3
    • /
    • pp.34-39
    • /
    • 2000
  • Performance data in the literature on air lift pumps have been based primarily on pumps of long length and large diameter (high lift pumps). Since mariculture operations involve pumps of relatively short length and small diameter, performance data are required for efficient operation. To provide such data, an experimental apparatus was designed and fabricated to test all lift pumps from 2.1 to 3.4 cm inside diameter and from 40 to 300 cm in length. Instrumentation was provided to measure water flow rate and air flow rate as well as water temperature, air temperature, and pressure throughout the system. Results from this study correlate well with high lift pump data in that, for a given pump geometry, maximum water flow occurs for a specific air flow rate. Driving the pump with air flows larger or smaller than this optimum flow rate will decrease the pumping rate. The optimum flows are significantly different for low lift pumps compared to high lift pumps. However, the pumping rate for low lift pumps approaches that for high lift pumps with increasing length.

  • PDF

Study on The Oxygen Transfer Properties of Airlift Pump (에어리프트 펌프의 산소 전달 특성에 관한 연구)

  • OH Se-Kyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.3
    • /
    • pp.451-458
    • /
    • 1997
  • The oxygen transfer coefficient was not significantly affected by either flow pattern, initial bubble size or the wastes present in the water studied. Surface active substances in the water did however influence the transition from bubble to slug flow. Airlift with length to diameter ratios less than 50 suffered from considerable losses in efficiency. When properly designed, airlift pumping efficiencies were comparable to those of conventional centrifugal pumps and the oxygen transfer efficiency were as high as or higher than those of diffused aeration systems.

  • PDF

The Treatment of Synthetic Wastewater by Biological Fluidised Bed With Air Lift Aeration (간접폭기식(間接曝氣式) 생물학적(生物學的) 유동층(流動層)을 이용한 합성하수(合成下水) 처리(處理))

  • Kim, Hwan Gi;Lee, Ki Wan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.7 no.3
    • /
    • pp.33-44
    • /
    • 1987
  • To improve the ability of oxygen transfer in Biological Fluidised Bed(BFB) processes, air lift aeration system was introduced, experimental investigations were performed for the oxygen transfer in reactor, the fluidisation as to Biomass Volatile Solids variation and the relationship between substrate removal rate and oxygen utilization. The experiments for this purpose were executed for the synthetic wastewater by continuous type reactor at $20^{\circ}C$ using reticulated polypropylene sheets as media. The obtained results showed that the oxygen transfer by air lift aeration would be more effective than any other aeration systems used in BFB reactor. Also, it has observed that the critical biomass concentration in reactor took a range of 20 to 23g/l. Applying cages to BFB reactor, biomass would be maintained uniformly in the bed and the fluidisation characteristics of media could be improved. Varying F/M ratio from 0.36 to 0.73, BOD removals were 91% or more. Therefore, this process was suited to the treatment of which F/M ratios are variable and specific oxygen uptake rates ($K_r$) were 0.23 to 0.26g $O_2/g\;VSS{\cdot}day$ at range of 15 to 20g BVS/l.

  • PDF

Evaluations of Grit Removal Efficiency of Tornado Block-Type Vortex Grit Separator (토네이도 블록형 선회류 침사제거기의 침사제거효율 평가)

  • Kim, Jong-Je;Lee, Bum-Soo;Yeom, Cheol-Min;Lim, Hee-Jae;Jung, Seok-Mo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.288-294
    • /
    • 2005
  • This study was conducted to evaluate the grit removal efficiency of tornado block-type vortex grit separator. Vortex grit separator was manufactured for this study, and it was characterized by the impeller and tornado block installed in separator. Impeller was installed to increase water velocity in the separator and tornado block was installed to increase the grit lifting efficiency. Pilot study was also conducted in A sewage treatment plant (STP) in Gyeonggi province from November 2003 to May 2004 (64 days). Major findings are as follows. 1. Impeller was proven to increase water velocity in the grit separator, especially in low flow rate. This influence will increase separation ratio of organics from grits, preventing those organics from sedimentation. 2. Sand (with 0.2~0.3mm size) removal efficiency was over 98 % and 96 %, at the flow rate of $500m^3/day$ and $750m^3/day$ under the condition that impeller rotation velocity kept at 15 rpm. Originally that grit separator was designed to have the capacity of $500m^3/day$. $750m^3/day$ was tried to investigate the performance of this type of grit separator under overload condition. Stable grit removal was still available to the extent of 150% of designed capacity. 3. It took less than 3 minutes for the grit separator to completely lift out 3 kgs of 0.2-0.3 mm sized, settled sand at the bottom to 2,060 mm high above water surface. But it showed the tendency to spend a little more time on lifting the grit as the grit size and the vertical height of the lift increased. 4. During experimental duration in A STP, it was found that the average amount of inlet grit was about 981 g/day (160~1,685 g/day) under $500m^3/day$ of operation condition, but it varied so severely during the experimental duration. After classification of discharged grit according to its size, grit with 0.3-0.42 mm size was found as largest part of output.

Implementation of ICT-based Underwater Communication Monitoring Device for Underwater Lifting (수중구조를 위한 ICT 기반 수중통신 모니터링 장치 구현)

  • Yoon, Jong-Hwa;Kang, Sang-iL;Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.396-400
    • /
    • 2022
  • In this study, an ICT-based underwater communication monitoring device for underwater structures is implemented based on lifting fixture that transport human bodies found on the seabed to sea level. The lifting fixture is packaged with a retback, sideback, and cartridge that injects air. Monitoring systems are developed in a mobile manner in a portable structure. The underwater ultrasonic sensor signal is supplied using a USB port, and the O/S consists of Linux. For the underwater communication dong test, a measurement test was conducted in real time from 6m to 40m in depth on the east coast. The ultrasonic sound sensor is converted to 2,400 bps to verify the transmission error according to the duality. The communication speed of sensor to monitoring is 115,200 bps, and the speed of communication from controller to receiver is 2,400 bps. In the commercialization stage of the lifting device, it is easy to develop a low-end type and the compatibility is wide.