• Title/Summary/Keyword: 에너지 측정 장치

Search Result 618, Processing Time 0.035 seconds

Surface Modification of Polyimide by Stationary Plasma thruster-type lasma Source : Correlations with Ahesion (SPT-type Plasma 발생장치를 이용한 폴리이미드의 표면개질과 접착력의 관계)

  • ;Ermakov Yu. A.
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2003.11a
    • /
    • pp.181-184
    • /
    • 2003
  • Low Energy High flux Plasma Source인 Stationary Plasma thruster (SPT)를 이용하여 폴리이미드의 표면개질 후 접촉각과 표면에너지의 변화를 조사하고 접착력과의 관계를 조사하였다. 이온에너지는 180 eV - 200 eV, 이온전류 밀도는 수백 ${\mu}A/cm^2$, 이온선량은 $5\times10^{15}/cm^2$부터, $10\times^{18}/cm^2$$Ar^+,\;N_2^+,\;O_2^+$를 이온 주입시켰다. 표면 처리된 폴리이미드에 대한 접촉각 변화는 dual contact anglemeter로 증류수와 에틸렌글리콜을 이용하여 측정하였고, 표면에너지의 변화량을 구하였다. 접촉각의 변화는 아르곤 이온의 경우는 최저 $35^{\circ}$, 질소와 산소의 경우 $1\times10^{17}/cm^2$에서 각각 $14^{\circ},\;10^{\circ}$정도의 전촉각을 보였으며, $5\times10^{17}/cm^2$이상에서는 측정하기 불가능하였다. 산소 이온빔으로 처리된 PI의 표면을 x-ray photoelectron spectroscopy를 통하여 측정하여본 결과, 친수성기가 많이 형성되었음을 확인할 수 있었다. 접촉각 측정으르부터 PI의 표변에너지는 42.1 mN/m에서 아르곤 이온빔의 처리 시 65.2 mN/m로 산소 이온빔의 처리 시 81.2 mN/m로 각각 1.5배, 1.9배 정도 증대하였다. 산소 이온빔으로 처리된 PI 표면위에 스퍼터링으로 300 nm 정도의 clad layer 형성 후 $20{\mu}m$ 정도의 구리 전기 도금막을 형성하여, peel 강도를 측정한 결과 0.79 kg/cm의 강도를 얻을 수 있었다.

  • PDF

마이크로채널 반응기를 이용한 소형 이동전원 연료전지용 수소발생기 개발

  • Yun, Yeong-Gi;Im, Seong-Dae;Park, Gu-Gon;Kim, Chang-Su;Seo, Dong-Ju
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.112-121
    • /
    • 2005
  • 본 연구는 2003년부터 2005년까지 2년간 에너지관리공단의 선행연구과제로서 진행되었으며 20 Watt 급 소형 연료전지에 수소를 공급할 수 있는 소형의 마이크로 채널 메탄올 개질장치를 개발하는 것을 목적으로 하였다. 개질장치는 개질기 본체, 여기에 반응열을 공급 해주는 촉매 연소기 그리고 연료를 증발시켜 주는 연료증발기의 세부분으로 구성되며 각 반응기의 개발 및 통합을 수행하였다. 반응기는 반응면적을 증가시키기 위하여 폭 $200{\sim}5000{\mu}m$, 필이 $200{\sim}5000{\mu}m$ 규모의 마이크로 채널 유로를 금속 박판을 화학 에칭하여 구현하였으며 이를 수십장 적층하여 전체 반응기를 제작하였다. 마이크로 채널표면에 내부 촉매 지지체를 먼저 코팅한 후 촉매를 코팅하는 방법을 사용하여 담지체 코팅으로 기하학적 표면적 대비 표면적이 10 배 이상 향상되는 우수한 결과를 얻을 수 있었고 촉매의 내구성이 월등히 향상 되었다. 저온 활성 촉매를 사용하여 $350^{\circ}C$ 이하에서 메탄을 전환율 90% 이상을 구현하였다. 실제 운전 후 측정 결과 개질 반응기의 부분별 온도차가 $20^{\circ}C$ 이내로 설계의 우수성을 확인하였다. 촉매 연소기를 이용한 개질 반응열 공급장치를 개발하여 20Watt 급 수소 생산을 위한 개질 반응기에 반응열을 공급하도록 하였다. 이와 함께 촉매 연소기를 이용한 연료 증발열 공급 장치 개발하여 개질기 공급 연료의 90% 이상이 기화되도록 하였다.

  • PDF

A Study on Data Acquisition System for Battery Automatic Charging and Discharging (배터리의 자동 충방전 데이터 수집 장치에 관한 연구)

  • Lee, Kyung-Sung;Moon, Chae-Joo;Jeong, Moon-Seon;Kim, Sang-Man;Youn, Young-Chan;Kim, Tae-Gon
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.70-71
    • /
    • 2011
  • 최근 신재생에너지에 대한 관심이 높아지면서 에너지 저장 장치로 친환경적인 2차 전지가 전기 에너지 저장 매체로 관심을 받고 있다. 2차 전지는 다양한 전자기기의 구동전원으로 널리 사용되고 있다. 2차 전지의 수명은 충방전과 관련이 있으며, 특히 니켈 수소 전지의 경우 과충전에 의한 온도 상승은 배터리 수명에 직접적인 영향을 준다. 경제성을 고려할 때 2차 전지는 배터리 관리 시스템을 필요로 하며, 충방전 전압과 전류 및 온도를 고려하여 충방전이 제어 되어야 한다. 본 논문은 범용 프로세서와 전압 전류 센서 및 온도센서를 사용하여 배터리의 자동 충방전 데이터 수집장치를 개발에 관한 것이다. 충방전 전압은 0.5V에서 15V까지 설정이 가능하도록 설계하였다. 제작된 장치로 충방전에 따른 배터리의 온도 변화가 측정 및 분석 가능 하였으며, 배터리 전압은 5mV 단위로 충방전이 가능함을 확인하였다.

  • PDF

Characterization of X-ray Detector for CCD-based Electronic Portal Imaging Device (CCD를 이용한 전자포탈영상장치의 엑스선 계측기 특성에 관한 연구)

  • 정용현;김호경;조규성;안성규;이형구;윤세철
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.2
    • /
    • pp.119-127
    • /
    • 2000
  • 금속판/형과스크린 계측기와 CCD 카메라를 이용한 방사선영상장치가 현재 전자포탈영상에 널리 쓰이고 있다. 이 장치의 효율적인 영상획득을 위해 계측효율이 좋고, 공간분해능력이 뛰어난 금속판/ 형과스크린 계측기의 두께를 최적화할 필요가 있었다. 이 논문에서는 금속판과 형광스크린의 두께가 계측효율과 공간분해능에 미치는 영향이 연구되었다. 이 결과는 치료 엑스선 영상장치에 쓰일 수 있는 금속판/형과스크린 계측기의 최적화된 두께를 결정하는데 쓰일 수 있다. 몬테칼로 방법을 이용하여 계산한6 MV 선형가속기에서 발생되는 엑시선의 에너지 스펙트럼을 바탕으로, 여러 가지 두께의 금속판/형광스크린에 대하여 계측효율과 공간분해능을 계산하였고, 이를 실험을 통해 검증하였다. 계측효율은 입사된 엑스선의 에너지가 형광스크린에 흡수된 비율로 계산되며, 공간분해능은 흡수된 에너지의 공간 분포를 통해 계산되었다. 계측효율은 금속판의 두께에 의해, 공간분해능은 형광스크린의 두께에 의해 결정될 수 있음을 본 연구를 통해 확인할 수 있었고, 이로써 특정이용에 관련된 금속판/형광스크린의 두께에 대한 서로 보상 (trade-off) 관계에 있음을 계산과 측정결과를 통해 확인할 수 있었고, 이로써 특정이용에 관련된 금속판/형광스크린 계측기의 최적화된 두께를 산출할 수 있게 되었다. 계산을 바탕으로 CCD를 이용한 전자포탈영상장치의 시작품을 설계 및 제작하였고 팬텀을 이용하여 영상을 얻었다. 단일 프레임 영상은 노이즈가 많으나, 프레임 평균 방법을 이용하여 영상의 질을 향상시킬 수 있었다.

  • PDF

Assessment on Energy storage efficiency effects of motor/generator for SFES (초전도 플라이휠 에너지 저장장치용 전동 발전기의 에너지 저장 효율 영향 평가)

  • Lee, Jeong-Phil;Han, Young-Hee;Jung, Se-Yong;Park, Byung-Jun;Park, Byeong-Cheol;Sung, Tae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.707-708
    • /
    • 2008
  • 본 논문에서는 초전도 플라이휠 에너지 저장장치 (Superconductor Flywheel Energy Storage System : SFES)의 에너지 변환을 위해 사용된 영구 자석형 전동 발전기(Permanent Magnet Synchronous Motor/Generator : PMSM/G)가 SFES의 에너지 저장효율에 미치는 영향을 평가하였다. SFES 시스템은 YBCO 벌크 초전도체를 이용한 저어널 타입(journal type)의 초전도 베어링을 사용하였으며, 슬롯리스 형 PMSM/G를 사용하였다. PMSM/G의 고정자 코어, 누설 자속 및 감겨진 코일에 의한 저장 에너지 손실을 측정하였다. 사용된 코어의 크기, 누설자속, 및 코일의 적절한 선정을 통하여 저장된 에너지의 손실을 상당히 줄일 수 있음을 확인하였다. 또한 영구자석과 코어가 동시에 회전하는 회전 코어형 전동발전기를 적용하여 에너지 손실을 매우 감소시킬 수 있음을 확인하였다.

  • PDF

Neutron Capture Resonance Energy Identification of Indium by Time-of-Flight Method (중성자 비행시간법을 이용한 인듐의 공명에너지 동정에 관한 연구)

  • Lee, Sam-Yol
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.403-408
    • /
    • 2012
  • Prompt gamma ray from the natural Indium sample was measured by using an assembly of BGO($Bi_4Ge_3O_{12}$) scintillation detectors in the neutron energy region from 1 to 300 eV. The assembly was composed of pieces of BGO. The spectrometer was composed geometrically as total energy absorption detector. 46-MeV electron linear accelerator which is located at Research Reactor Institute, Kyoto University used for neutron sources from photonuclear reaction. The measurement of the neutron capture resonances was performed to below neutron energy 1 keV, because of strong X-ray effect from photonuclear reaction in Ta target and short distance from the target to an assembly of detector. The distance of neutron flight path is $12.7{\pm}0.02m$. The large neutron capture resonances were measured from 1 to 400 eV. The energy in the capture resonance was compared with the evaluated values. The large resonances were seen in the present measurement. General agreement can be seen between the present measurement and the previous evaluated data in relevant energy region. In the present study, we measured the continues resonance structure above 1 keV neutron energy region. 91.49 eV new neutron capture resonance was found in present measurement.

Empirical Determination of a CT X-ray Spectra by Numerical Analysis using Transmission Data (투과선량의 수치해석에 의한 전산화단층영상장치 X선의 에너지 분포결정)

  • 최태진;김옥배;서수지
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.35-43
    • /
    • 1997
  • The knowledge of x-ray spectra is highly desirable in some investigation involves the differential penetrating power and absorption coefficient correction of various photon beam. The transmission data were obtained from the 80 kVp and 120 kVp of CT x-ray beam with the aluminium filter which is designed in a 30 cm of diameter and pipe-typed filter was prepared from 5.0 mm upto 92.3 mm of thickness. To obtain the reconstructed spectra of CT x-ray, the investigator used the iterative numerical analysis which has been extended to include the tungsten characteristics from experimental transmission data with energy interval of 2 keV. Comparison of the calculated transmission data from the reconstructed spectra with that of measurement shows good agreement in both 80 kVp and 120 kVp x-ray beams. This numerical analysis based on iteratively calculation of fractional exposure per energy interval shows the high potential of usefulness of determination the x-ray spectra from the attenuated beam in diagnostic energy range.

  • PDF

The flow characteristics of partially shrubs vegetated stream (관목류가 부분 식재된 하천의 흐름 특성)

  • Park, Moon-Hyeong;Kim, Jong-Tae;Kim, Eun-Jin;Lee, Doo-Han
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.765-765
    • /
    • 2012
  • 수목이 존재하지 않는 하천과 비교하여 하천 내에 수목이 존재하는 경우, 수목에 의한 항력에 의하여 수위는 상승하지만 차이는 크지 않으며, 수목이 식재된 구간의 유속이 현저하게 저하되는 것으로 알려져 있다. 식재구간과 비식재구간의 현저한 유속차이는 활발한 에너지 교환에 기인한다. 이러한 특성은 하천에 여러 가지 시설물 설치 및 수목 식재 계획 수립 등에 있어 고려되어야 할 사항이다. 또한 수치해석을 통한 정확한 흐름예측을 위해서는 두 구간 사이의 합리적인 에너지 교환계수를 결정하여야 한다. 수목 식재구간과 비식재구간의 에너지교환 특성에 대한 연구는 대부분 모형식생(단순한 봉 형태 위주)을 이용한 소규모 개수로 실험장치를 이용하거나, 이론적으로 접근하고 있다. 이러한 연구는 흐름 상사 등을 고려할 때, 정성적인 분석에 그치고 있으며, 정량적인 분석을 위해서는 원형에 가까운 실험시설을 이용하는 것이 타당할 것으로 생각된다. 본 연구에서는 단면의 높이, 상단폭, 저면폭이 각각 2 m, 11 m, 3 m인 소하천에 가까운 실험수로에 관목류(왕버들)를 식재하여 실험을 수행하였다. 수로의 중앙부와 사면에 식재된 경우, 식재 패턴이 다른 경우(parallel space, staggered space) 등 다양한 조건에 대하여 흐름특성을 분석하였다. 각 경우에 대하여 배수곡선을 측정하여 흐름저항 특성을 분석하였으며, 50Hz의 자료 획득이 가능한 micro-ADV를 이용하여 횡단면의 난류량을 측정하였다. 측정된 난류량을 이용하여 전단속도의 변화, 난류에너지 변화 등을 분석하였다. 이 연구는 하천내 수목식재 계획 수립, 수치모형의 중요한 매개변수인 에너지교환계수의 합리적 결정에 기여할 수 있을 것으로 보인다.

  • PDF

축전 결합 차폐막(faraday shield)이 없는 평판형 유도 결합 아르곤 플라즈마에서 전자 에너지 분포 및 플라즈마 전위에 대한 연구

  • 서상훈;홍정인;장홍영
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.217-217
    • /
    • 1999
  • 축전 결합 차폐막(Faraday shield)이 없는 평판형 유도 결합 플라즈마 장치에서 방전 모드 전이 중출력 결합 변화동안 전자 가열에 대한 연구가 행하여졌다. 전자 에너지 분포 함수(EEDF)의 전개가 RF 보상탐침을 사용, 교류 충첩 방법으로 측정된다. RF 출력에 따른 전자 밀도, 유효 전자 온도 및 특히, 플라즈마 전위의 동향이 제시된다. bi-Maxwellian EEDF를 가진 플라즈마에서 플라즈마 전위가 고 에너지 전자 그룹에 의해 결정됨을 보이고, 플라즈마 전위와 EEDF 상호 관계가 논의된다. 실험 결과로부터 RF출력에 따른 플라즈마 전위의 변화가 전자 가열에 있어 축전 출력 결합의 상대적인 기여의 변화를 반영함을 알 수 있다.

  • PDF

Rod Energy Ratio Measurement of SPT (표준관입시험의 동적효율 측정)

  • Lee, Ho-Chun;Kim, Byeong-Il;Park, Yong-Won
    • Geotechnical Engineering
    • /
    • v.13 no.1
    • /
    • pp.169-182
    • /
    • 1997
  • It is known that some amount of loss in impact energy takes place due to some limitations and problems during the performance of the field SPT. Actual energy level tractsferred to the rod should be measured to correct the SPT-N values tested in the field In this paper, the ratio of energy transferred to the rod through the anvil to impact energy is measured by using sharpy impact test equipment and also analysed by using GRL-WEAP This result is certified and compared with that of field SPT As the results of this study, the average rod energy ratio of the R-P hammer and the Trip hammer is calculated at 0.726 and 0.728 respectively, but it is suggested that 0.72 should be used. By using the hammer energy ratio 64.2% and 75.0% obtained from field measurement, the average energy ratio of the SPT for the R-P hammer is calculated at 46.7% and 54.5% for the Trip hammer.

  • PDF