Comparison of Electron Beam Dosimetries by Means of Several Kinds of Dosimeters (수종의 측정기에 의한 전자선의 선량 측정의 비교)

  • Kang Wee-Saing
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.93-100
    • /
    • 1989
  • Several combinations of measuring devices and phantoms were studied to measure electron beams. Silicon Pmt junction diode was used to find the dependence of depth dose profile on field size on axis of electron beam Depths of 50, 80 and $90\%$ doses increased with the field size for small fields. For some larger fields, they were nearly constant. The smallest of field sizes over which the parameters were constant was enlarged with increase of the energy of electron beams. Depth dose distributions on axis of electron beam of $10\times10cm^2$ field were studied with several combinations of measuring devices and phantoms. Cylindrical ion chamber could not be used for measurement of surface dose, and was not convenient for measurement of near surface region of 6MeV electron. With some exceptions, parameters agreed well with those studied by different devices and phantoms. Surface dose in some energies showed $4\%$ difference between maximum and minimum. For 18MeV, depths of 80 and $90\%$ doses were considerably shallower by film than by others. Parallel-plate ion chamber with polystyrene phamtom and silicon PN junction would be recommended for measurement of central axis depth dose of electron beams with considerably large field size. It is desirable not to use cylindrical ion chamber for the purpose of measurement of surface dose or near surface region for lower energy electron beam. It is questionable that film would be recommended for measurement of dose distribution of electron with high energy like as 18MeV.

  • PDF

Computer Simulation for Developing the Plate and Corner Type In-Situ Thermal Resistance Measuring Device (평판 및 모서리형 현장열저항 측정기기 개발을 위한 Computer Simulation)

  • Kang, Byeong-Woong;Park, Seung-Ik;Yu, Seung-Sun;Park, Hyo-Soon
    • Solar Energy
    • /
    • v.19 no.4
    • /
    • pp.71-80
    • /
    • 1999
  • For developing a new measuring device which enables the thermal resistance at comers of the building envelope in addition to the plate wall measuring device, computer simulations were performed to clarify the problems produced during previous tests. For the optimum design to reduce the temperature deviation in measuring device, the specifications of the measuring devices are to be as follows : Dimension of the device is $500{\times}500{\times}100mm$ in size, heating plate is seperated to some degree from the inner surface of the measuring device, lower temperature of heating plate is as effective as possible, fans should be located at the upper part in the measuring device and face to downward.

  • PDF

Consideration of Surface Dose and Depth of Maximum Dose Using Various Detectors for High Energy X-rays (측정기에 따른 고에너지 X-선의 표면 선량 및 최대 선량 지점 고찰)

  • Lee Yong Ha;Park Kyung Ran;Lee Jong Young;Lee Ik Jae;Park Young Woo;Lee Kang Kyoo
    • Radiation Oncology Journal
    • /
    • v.21 no.4
    • /
    • pp.322-329
    • /
    • 2003
  • Purpose: It is difficult to exactly determine the surface dose and the dose distribution In buildup region of high energy X-rays by using the conventional ion chamber. The aim of this study Is to evaluate the accuracy of widely used dosimetry systems to measure the surface dose and the depth of maximum dose (d$_{max}$). Materials and Methods: We measured the percent depth dose (PDD) from the surface to the d$_{max}$ in either a water phantom or in a solid water phantom using TLD-100 chips, thimble type ion chamber, diode detector, diamond detector and Markus parallel plate ion chamber for 6 MV and 15 MV X-rays, 10$\times$10 cm$^{2}$, at SSD=100cm. We analysed the surface dose and the d$_{max}$. In order to verify the accuracy of the TLD data, we executed the Monte Carlo simulation for 5 MV X-ray beams. Results: The surface doses In 6 MV and IS MV X-rays were 29.31% and 23.36% ior Markus parallel plate ion chamber, 37.17$\%$ and 24.01$\%$ for TLD, 34.87$\%$ and 24.06$\%$ for diamond detector, 38.13$\%$ and 27.8$\%$ for diode detector, and 47.92$\%$ and 35.01$\%$ for thimble type ion chamber, respectively. in Monte Carlo simulation for 6 MV X-rays, the surface dose was 36.22$\%$, which Is similar to the 37.17$\%$ of the TLD measurement data. The d$_{max}$ In 6 WV and 15 MV X-rays was 14$\~$16 mm and 27$\~$29 mm, respectively. There was no significant difference in the d$_{max}$ among the detectors. Conclusion: There was a remarkable difference in the surface dose among the detectors. The Markus parallel plate chamber showed the most accurate result. The surface dose of the thimble ion chamber was 10$\%$ higher than that of other detectors. We suggest that the correction should be made when the surface dose of the thimble ion chamber Is used for the treatment planning ion the supeficial tumors. All the detectors used In our study showed no difference in the d$_{max}$.

High Energy Photon Dosimetry by ESR Spectroscopy in Radiotherapy (ESR Spectroscopy에 의한 치료용 고에너지 광자선의 선량측정)

  • Chu, Sung-Sil
    • Progress in Medical Physics
    • /
    • v.1 no.1
    • /
    • pp.31-42
    • /
    • 1990
  • The finding of long lived free radicals produced by ionizing radiation in organic crystals and the quantification of this effect by electron spin resonance(ESR) spactroscopy has proven excellent dosimetric applicability. The tissue equivalent alanine dosimeter also appear appropriate for radiation therapy level dosimetry. The dose measurement was performed in a Rando phantom using high energy photons as produced by high energy medical linear accelerator and cobalt-60 teletherapy unit. The absorbed dose range of the ESR/alanine dosimetry system could be extended down to 0.1 Gy. The response of the alanine dosimeters was determined for photons at different therapeutic dose levels from less than 0.1 Gy to 100 Gy and the depth dose measurements were carried out for photon energies of 1.25MeV, 6 and 10 MV with alanine dosimeters in Rando phantom. Comparisons between ESR/alanine in a Rando phantom and ion chamber in a water phantom were made performing depth dose measurements to examine the agreement of both methods under field conditions.

  • PDF

Determination of Surface Energy by Means of Home-Made Goniometer and Image Analyzing Software for Contact Angle Measurement (수제 접촉각 측정기와 영상 분석 프로그램을 이용한 표면에너지의 측정)

  • Cho, Seo-Rin;Cho, Han-Gook
    • Journal of the Korean Chemical Society
    • /
    • v.57 no.4
    • /
    • pp.432-438
    • /
    • 2013
  • We report a contact angle goniometer that can be easily assembled and used in high school and general chemistry experiments. It consists of an LED flash, a sample stand, and a camera fixed on an optical bread board, and the sample area is covered to block light from outside with a box with holes on both sides. ImageJ, free image analyzing software and a JAVA plugin (Drop_analysis) were used to determine the contact angle of liquid drop resting on solid surface. The contact angles of various liquids were successfully measured on various surfaces. The solid surface energies have also been determined using the Owen-Wendt method from the contact angles of $H_2O$ and $CH_2I_2$. The results reasonably agree with the previously reported values, showing the surface characteristics and modification as well as the dispersive and polar contributions. These contact angle goniometer and method for determination of the contact angle and surface energy can be applied to observation of various surface properties including wettability, hydrophilicity, and water repelling. Students can learn how the surface properties are related to the intermolecular interactions and gain experience about the equilibrium between the related forces, optics, and mathematical derivations.

Real-Time Activity Monitoring Algorithm Using A Tri-axial Accelerometer (3축 가속도 센서를 이용한 실시간 활동량 모니터링 알고리즘)

  • Lho, Hyung-Suk;Kim, Yun-Kyung;Cho, We-Duke
    • The KIPS Transactions:PartD
    • /
    • v.18D no.2
    • /
    • pp.143-148
    • /
    • 2011
  • In this paper developed a wearable activity device and algorithm which can be converted into the real-time activity and monitoring by acquiring sensor row data to be occurred when a person is walking by using a tri-axial accelerometer. Test was proceeded at various step speeds such as slow walking, walking, fast walking, slow running, running and fast running, etc. for 36 minutes in accordance with the test protocol after wearing a metabolic test system(K4B2), Actical and the device developed in this study at the treadmill with 59 participants of subjects as its target. To measure the activity of human body, a regression equation estimating the Energy Expenditure(EE) was drawn by using data output from the accelerometer and information on subjects. As a result of experiment, the recognition rate of algorithm being proposed was shown the activity conversion algorithm was enhanced by 1.61% better than the performance of Actical.

The Effect of X-ray Tube Potential on the Image Quality of Digital Chest Radiography with an Amorphus Silicon Flat Panel Detectors (비정질 평판형 측정기를 이용한 디지털 흉부 방사선 영상에서의 효과적인 관전압 선택)

  • Kim, Jung-Min;Im, Eun-Kyung
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.273-277
    • /
    • 2005
  • The rapid development in digital acquisition technology in radiography has not been accompanied by information regarding optimum radiolographic technique for use with an amorphus silicon flat panel detector. The purpose of our study was to compared image quality and radiation dose of an amorphus silicon flat panel detectors for digital chest radiography. All examinations were performed by using an amorphus silicon flat panel detector. Chest radiographs of an chest phantom were obtained with peak kilovoltage values of $60{\sim}150kVp$. Published data on the effect of x-ray beam energy on image quality and patient dose when using an amorphus silicon flat panel detector. It is important that radiographers are aware of optimum kVp selection for an amorphus silicon flat panel detector system, particularly for the commonly performed chest examination.

  • PDF

Characteristics of Open-Loop Current Sensor with Temperature Compensation Circuit (온도보상회로를 부착한 개방형 전류측정기의 특성)

  • Ku, Myung-Hwan;Park, Ju-Gyeong;Cha, Guee-Soo;Kim, Dong-Hui;Choi, Jong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8306-8313
    • /
    • 2015
  • Open-type current sensors have been commonly used for DC motor controller, AC variable controller and Uninterruptible Power Supply. Recently they have begun to be used more widely, as the growth of renewable energy and smart-grid in power system. Considering most of the open-type current sensors are imported, developing the core technology needed to produce open-type current sensors is required. This paper describes the development and test results of open-type current sensors. Design of C type magnetic core, selection and test of a Hall sensor, design of current source circuit and signal conditioning circuit are described. 100A class DIP(Dual In-line Package) type and SMD(Surface Mount Devide) type open-type current sensors was made and tested. Test results show that the developed open-type current sensor satisfies the accuracy requirement of 2% and linearity requirement of 2% at 100 A of DC and AC current of 60Hz. Temperature compensation was carried out by using a temperature compensation circuit with NTC(Negative Temperature Coefficient) thermistor and the effect of the temperature compensation are described.

과학기술위성 1호의 탑재체 자료 수신 시스템

  • 강경인;김문규;이종주;임종태
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.04a
    • /
    • pp.91-91
    • /
    • 2004
  • 과학기술위성 1호의 탑재체는 원자외선 분광기(FIMS), 우주물리 관측기(SPP), 자료수집 시스템(DCS), 그리고 고정밀 별감지기(NAST)가 있으며, 우주물리 관측기는 저에너지 검출기(ESA), 고에너지 검출기(SST), 랑마이어 탐침(LP)과 자기력 측정기(SMAG) 등 4개의 센서로 구성되어있다. 위성에 탑재된 각각의 관측기는 운용시 발생되는 데이터를 위성의 대용량 메모리 시스템에 저장되며, 위성이 한반도 상공을 지나는 교신구간에 X-Band 대역의 RF를 통하여 지상으로 전송된다. (중략)

  • PDF

Study of back surface field for orientation on Crystalline Silicon solar cell (결정방향에 따른 결정질 실리콘 태양전지 후면전계 특성 연구)

  • Kim, Hyunho;Park, Sungeun;Kim, Young Do;Song, Jooyong;Tark, Sung Ju;Park, Hyomin;Kim, Seongtak;Kim, Donghwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.41.2-41.2
    • /
    • 2010
  • 최근 태양전지 제조비용 절감을 위해 초박형 실리콘 태양전지 개발이 활발히 이루어지고 있다. 이에 따라 후면전계(Back Surface Field, BSF) 특성에 대한 관심이 높아지는 추세이다. 이에 본 연구에서는 후면의 결정방향 및 표면구조에 따라 형성되는 후면전계(BSF)의 특성에 대해 알아보고자 하였다. 후면이 절삭손상층 식각(Saw damage etching) 후 (100)면이 드러난 실리콘 기판과 텍스쳐링(Texturing) 후 (111)면이 드러난 실리콘 기판에 후면 전극을 스크린 인쇄 후 Ramp up rate을 달리 하여 소성 공정(RTP system)을 통해 후면전계(BSF)를 형성하여 비교하였다. 후면전계(BSF)의 형상과 특성만을 평가하기 위하여 염산을 이용하여 후면 전극층을 제거하였다. 후면 전극 제거 후 주사전자현미경(Scanning Electron Microscopy)과 3차원 미세형상측정기(Non-contacting optical profiler)로 후면전계(BSF)의 형상을 비교하였다. 또한 후면전계(BSF)의 특성을 평가하고자 Quasi-Steady-State Photo Conductance(QSSPC)를 사용하여 포화전류(Saturation current, $J_0$)을 측정하였고, 면저항 측정기(4-point probe)로 면저항을 측정하여 비교하였다. 후면 전계(BSF)는 (100)면과 (111)면에서 모두 Ramp up rate이 빠를수록 향상된 특성을 보였고, (111)면에서 더 큰 차이를 보였다.

  • PDF