• Title/Summary/Keyword: 에너지 정의

Search Result 2,864, Processing Time 0.031 seconds

The Study on Thermal Shock Test Characteristics of Solar Cell for Long-term Reliability Test (장기 신뢰성 평가를 위한 태양전지의 열충격 시험 특성에 관한 연구)

  • Kang, Min-Soo;Kim, Do-Seok;Jeon, Yu-Jae;Shin, Young-Eui
    • Journal of Energy Engineering
    • /
    • v.21 no.1
    • /
    • pp.26-32
    • /
    • 2012
  • This study has been performed Thermal Shock test for analyze the cause of Power drop in PV(Photovoltaic) Module. Thermal Shock test condition was performed with temperature range from $-40^{\circ}C{\sim}85^{\circ}C$. One cycle time is 30min. which are consist of low and high temperature 15min. each other. The test was performed with total 500cycles. EL, I-V were conducted every 100cycle up to 500cycles. Mono Cell resulted in 8% Power drop rates in Bare Cell and 9% in Solar Cell. In the case of Multi Cell resulted in 6% Power drop rates in Bare Cell and 13% in Solar Cell. After Thermal Shock test, Solar Cell's Power drop resulted from surface damages, but in the case of Bare Cell's Power drop had no surface damages. Therefore, Bare Cell's Power drop was confirmed as according to leakage current increase by analysis of Fill Factor after Thermal Shock test. Also, Solar Cell's Power drop rates are higher than that of Bare Cell because of surface damages and consuming electric power increase. From now on, it should be considered that analyzed the reasons of Fill Factor decrease and irregular Power drop in PV module and Cell level using cross section, various conditions and test methods.

Ultimate Strength tests Considering Stranding Damage (좌초손상을 고려한 최종강도 실험)

  • Lee, T.K.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.11 no.2
    • /
    • pp.86-91
    • /
    • 2008
  • Ships operating in littoral sea are likely to be subjected to accidental load such as stranding. Once she has damage on the hull structure, her ultimate strength will be reduced. This paper is to investigate the effect of the stranding damage on ultimate strength of ship structure by using a series of collapse tests. For the experiment, 720 mm $\times$720 mm in section and 900mm in length of five box-girder models with stiffeners were pre- pared. Of the five, one has no damage and faur have an diamond shaped damage which represents the shape of rock section in seabed. The damage size is different between models. Among the damaged models, the damages of 3 of them were made by cutting the plate and one by pressing to represent stranding damage. Experiments were carried out under pure bending load and the applied load and displacements were recorded. The ultimate strength is reduced as the damage size increases, as expected. The largest damaged model has the damage size of 30% of breadth and its ultimate strength is reduced by 21% than that of no damaged one. The pressed one has lower ultimate strength than cut one. This might be due to the fact that the plate around the pressed damage area effect negatively on the ultimate strength.

  • PDF

Operatonal characteristics of the PLS linac vacuum system (PLS 선형가속기 진공계의 운전특성)

  • 김임경;박용정;김경렬;남궁원
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.4
    • /
    • pp.269-277
    • /
    • 1996
  • The vacuum systems of PLS linac provides average pressure of $2.6\times 10^{-6}$Pa under high power microwave of 54 MW peak with 4.1 $\mu \textrm s$ pulse width and 10 Hz repetition rates. The base pressure of system is$2.4\times 10^{-6}$Pa with 45$^{\circ}C$ cooling water. The outgassing rate of the system is decreased from $3.0\times 10^{-11}Torr-l/sec-\textrm{cm}^2$ at the initial stage after installation to $1\times 10^{-12}Torr-l/sec-\textrm{cm}^2$ at present. Total accumulated microwave energy dose is about 140 GJ per module. All ion pumps are working under saturated regime and effective pumping speeds of 60 I/s, 230 I/s ion pumps are 45 I/s, 65 I/s, 140 I/s under the operating range. Main problems occurred in recent year are troubles of ion pump controller and vacuum gauge controller, vacuum leak of energy doubler window and electron gun ceramic, and water leak in the dummy load of acceleraing columns. Total of 41 troubles with 140. 8 hours down time give good system availability of 98%. Down time can be reduced by high power waveguide valves and water dummy loads under development, and then availability is expected to be increased up to 99.5%.

  • PDF

Analytical Study on the Appropriateness of Design Formula and Possibility of Improving Bearing Capacity of Bored Pile (매입말뚝의 설계식 적정성 및 지지력 상향 가능성 분석 연구)

  • Park, Jong-Bae;Lee, Bum-Sik;Park, Yong-Boo
    • Land and Housing Review
    • /
    • v.6 no.3
    • /
    • pp.139-145
    • /
    • 2015
  • To improve the pile design efficiency(design bearing capacity/the strength of materials) from 70 percent(160tonf) to 80 percent(190tonf), this paper analysed the existing pile loading test data and performed the precise dynamic loading test and Bi-directional loading test for the first time in Korea. Analysis result of the existing dynamic loading test data by Davisson method showed that bearing capacity of piles penetrated at weathered rock stratum(N=50/15) exceeded 190tonf. But the analysis result by CAPWAP method showed that piles less than the target bearing capacity were 40% due to the lack of impact energy. To get the target bearing capacity from the dynamic loading test, using the hammer over 6tonf to trigger the enough impact energy is necessary. Allowable bearing capacty of Bi-directional static loading test by Davisson method was 260.0~335tonf(ave. 285.3tonf) and exceeded overwhelmingly the target capacity. And this exceeded the bearing capacity of precise dynamic loading test(ave. 202.3tonf) performed on the same piles over 40%. The difference between the capacity of Bi-directional loading test and dynamic loading test was caused by the insufficient impact energy during dynamic loading test and increase by interlocking effect by near piles during Bi-directional static loading test.

Syngas Concentration and Efficiency in Heavy Residual Oil Gasification with 1 Ton/Day-Class Entrained-Bed Reactor (1톤/일급 분류층 가스화기에서 중질잔사유의 가스화 합성가스 조성 및 효율 변화)

  • 주지선;나혜령;윤용승
    • Journal of Energy Engineering
    • /
    • v.12 no.1
    • /
    • pp.58-64
    • /
    • 2003
  • With the 1 ton/day-class entrained-bed gasification system, heavy residual oil from local refinery was gasified at the operating conditions of 1,000~1,20$0^{\circ}C$ and 3 $kg_f$/$\textrm{cm}^2$ in order to determine the variation of syngas composition, carbon conversion, and cold gas efficiency. Produced syngas consists of mainly CO, H$_2$, $CO_2$, and the methane concentrations. Results yielded a maximum syngas composition of 45% H$_2$ and 26%, CO at the 31 kg/hr feeding condition. The maximum carbon conversion and cold gas efficiency were 87% and 68%, respectively at the feeding conditions of 20 kg/hr and oxygen/feed ratio of 1.2. When oxygen feeding amount that is one of the most important operating parameter in gasification was increased, concentration of hydrogen in the syngas is greatly increased comparing to the concentration of CO and $CO_2$. The temperature exhibited about 11$0^{\circ}C$ raise while oxygen/feed ratio changed from 0.6 to 1.2. Methane concentration showed enhanced dropping rate with increase in gasifier temperature and the useful relationship between the gasifier temperature and methane concentration existed such that it can be employed as an indirect measure of inside gasifier temperature.

Action Spectra for Light-Induced De-Epoxidation and Epoxidation of Xanthophylls in Spinach Leaf

  • Lee, Kang-Ho
    • Applied Biological Chemistry
    • /
    • v.9
    • /
    • pp.1-7
    • /
    • 1968
  • The action Spectra for violaxanthin de-epoxidation and zeaxanthin expoxidation in New Zealand spinach leaf segments Tetragonia expansa, were determined at equal incident quanta of $2.0{\times}10^{15}$ quanta $cm^{-2}$ $second^{-1}$. The action spectrum for de-epoxidation had major peaks at approximately 180 and 648 nm. Blue light was slightly more effective than red light and little activity was observed beyond 700 nm. The action spectrum for epoxidation showed major peaks at around 441 and 670 nm. Blue light was more effective than red light and light beyond 700 nm showed definite activity. The net result of de-epoxidation and epoxidation is a cyclic scheme, the violaxanthin cycle, which consumes $O_2$ and photoproducts. The action spectra indicate that the violaxanthin cycle is more active m clue than in red light and therefore could accout for $O_2$ uptake stimulated by blue light. The differences between the action spectra for de-epoxidation suggest that possibly two photosynthetic systems are involved. It was suggested that the violaxanthin cycle may functional a pathway for the consumption of excess photoproducts generated in blue light or the conversion of these photoproducts to other forms of energy.

  • PDF

Effects of fruit body characteristics of Lentinula edodes according to irradiation intensity of the green LED with sawdust substrate cultivation (표고 톱밥배지 재배시 녹색LED 광량이 자실체 생육에 미치는 영향)

  • Baek, Il-Sun;Jeoung, Yun-Kyeoung;Lee, Yun-Hae;Kim, Jeong-Han;Chi, Jeong-Hyun
    • Journal of Mushroom
    • /
    • v.12 no.4
    • /
    • pp.270-274
    • /
    • 2014
  • In previous studies, we selected the green LED(light emitting diodes) for suitable wavelength of the light by higher commercial yields and lower ratio of the abnormal fruit body in Lentinula edodes. In this study, we aimed to select efficient irradiation intensity of the green LED. Stronger irradiation intensity of the green LED resulted in more polyphenol content of fruit body. And Polyphenol content of fluorescent lamp was similar to that of the green LED $20umol{\cdot}m^{-2}{\cdot}s^{-1}$.. Ergosterol content of the green LED $5umol{\cdot}m^{-2}{\cdot}s^{-1}$ was showed higher 2.1 times than that of the fluorescent lamp. In four level of irradiation intensity, 5, 10, 15, $20umol{\cdot}m^{-2}{\cdot}s^{-1}$ there was no big difference in characteristics of the fruit body. However the yield of fruit body in the green LED $5umol{\cdot}m^{-2}{\cdot}s^{-1}$ is higher than the others. In addition, The amount of electricity used of the green LED $5umol{\cdot}m^{-2}{\cdot}s^{-1}$ was reduced 15.9% than that of the fluorescent lamp. In conclusion, we selected $5umol{\cdot}m^{-2}{\cdot}s^{-1}$ for suitable irradiation intensity in Lentinula edodes with sawdust substrate cultivation.

Electrocatalytic alcohol oxidation on Pt/ATO nanoparticle (ATO nanoparticle에 담지된 백금 촉매의 전기화학적 알콜 산화 반응에 관한 연구)

  • Lee, Kug-Seung;Park, In-Su;Jung, Dae-Sik;Park, Hee-Young;Sung, Yung-Eun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.463-466
    • /
    • 2006
  • 직접 알콜 연료전지는 액체인 알콜을 직접 연료전지에 공급하여 연소시킴으로써 높은 효율을 갖는 휴대용전원으로 주목받는 장치이다. 직접 알콜 연료전지에 담지체로 사용되는 탄소 소재는 넓은 표면적과 우수한 전기전도도를 가지고 있다는 장점 있으나 금속 촉매와의 상호작용이 약하여 촉매 활성에 영향을 주지 못한다. 산화물을 담지체로 사용할 경우 이러한 금속-담지체 간의 상호작용으로 인한 촉매활성 증가 및 입자성장 억제의 효과를 기대할 수 있다. 본 연구에서는, 안티몬 도핑된 주석산화물 (Sb-doped SnO2 : ATO nanoparticle)을 직접 메탄올 연료전지용 담지체어 적용하였으며 합성 과정은 다음과 같다. SnC14 5H2O SbC13, NaOH, HCl 수용액 혼합물을 삼구 플라스크에 넣고 $100^{\circ}C$ 온도에서 환류(reflux) 시킨 후 세척 및 건조하여 Air 분위기에서 열처리하였다. 합성된 산화물 수용액에 폴리올 방법으로 합성된 백금 콜로이드를 담지하였으며, 세척과 건조를 통하여 산화물에 담지된 백금 촉매를 촉매를 합성하였다. 촉매의 구조분석을 위해 XRD, TEM을 사용하였으며, 전극촉매로서의 활성을 평가하기 위해 cyclic voltammetry을 평가하였다. 본 연구에서는 백금의 담지량에 따른 Costripping voltammetry특성과 메탄올 및 에탄올 산화 반응 특성에 대하여, 탄소를 담지체로 사용한 Pt/C 촉매와 비교 평가하였다. 알콜 산화반응 평가결과, 주석산화물에 담지한 촉매가 탄소를 담지체로 사용한 촉매보다 우수한 활성을 나타내었으며 활성증가는 메탄올에 비해 에탄올 산화 반응의 경우 크게 증가하였다. 막과 비교해 보았다. $ZrO_2$ 입자는 전도성이며 동시에 친수성을 나타내기 때문에 상용 막에 비하여 함수율 및 수소이온 전도도가 우수하게 나타났다. 복합막의 이러한 물성은 $100^{\circ}C$이상의 고온에서 전해질 막 내의 물 관리를 용이하게 한다. 단위 전지 운전 온도 $130^{\circ}C$, 상대습도 37%의 운전 조건에서도 상당히 우수한 전지 성능을 보임에 따라 고온/저가습 조건에서 상용 Nafion 112 막보다 우수한 막 특성을 나타냄을 확인하였다.소/배후방사능비는 각각 $2.18{\pm}0.03,\;2.56{\pm}0.11,\;3.08{\pm}0.18,\;3.77{\pm}0.17,\;4.70{\pm}0.45$ 그리고 $5.59{\pm}0.40$이었고, $^{67}Ga$-citrate의 경우 2시간, 24시간, 48시간에 $3.06{\pm}0.84,\;4.12{\pm}0.54\;4.55{\pm}0.74 $이었다. 결론 : Transferrin에 $^{99m}Tc$을 이용한 방사성표지가 성공적으로 이루어졌고, $^{99m}Tc$-transferrin의 표지효율은 8시간까지 95% 이상의 안정된 방사성표지효율을 보였다. $^{99m}Tc$-transferrin을 이용한 감염영상을 성공적으로 얻을 수 있었으며, $^{67}Ga$-citrate 영상과 비교하여 더 빠른 시간 안에 우수한 영상을 얻을 수 있었다. 그러므로 $^{99m}Tc$<

  • PDF

Effects of the low power He-Ne IR laser on the changes of the chemical components in serum of the peripheral neuropathy in diabetic rats (저에너지 He-Ne IR 레이저가 말초신경병증 당뇨쥐의 혈액화학 성분 변화에 미치는 영향)

  • Rho, Min-Hee;Kim, Jae-Young;Lee, Mi-Ae;Baek, Su-Jeong
    • Journal of Korean Physical Therapy Science
    • /
    • v.8 no.2
    • /
    • pp.1033-1038
    • /
    • 2001
  • This studies were to investigate the effects of low power Helium-Neon Infra-Red(He-Ne IR) laser on the changes of the chemical components in serum of the peripheral neuropathy in diabetic rats. The twenty one Spraque-Dawley adult male rats were assigned to the 3 groups: the control group(N=7), the diabetic group(n=7) and the laser group(n=7). The diabetic group was induced with a single intravenous injecion of 50mg/kg body weight streptozotocin dissolved to 0.01mol/L citrate buffer, pH 4.5. The experimental1asser group was irradiated low power He-Ne IR laser for 5 minutes every day during 21 days to the diabetic group. The results were as follows: 1. ALT was increased the laser treatment group than the diabetic group. but that was not significant. 2. AST was significantly increased the laser treatment group than the control group and the diabetic group. 3. LDH was significantly decreased the diabetic group and laser treatment group. 4. ALP was significantly increased the diabetic group and laser treatment group. 5. CHOL was significantly decreased the laser treatment group than the diabetic group. 6. TRIG was significantly increased the laser treatment group than the diabetic group. 7. CPK was significantly increased the laser treatment group than the control group and the diabetic group.

  • PDF

A Numerical Study on the Efficiency of an Industrial Furnace for Oxygen Combustion Conditions (산소부화용 공업로의 운전조건이 열효율에 미치는 영향)

  • Kim, Kang-Min;Lee, Yeon-Kyung;Ahn, Seok-Gi;Kim, Gyu-Bo;Yoo, In;Jeon, Chung-Hwan
    • Journal of Energy Engineering
    • /
    • v.24 no.3
    • /
    • pp.82-88
    • /
    • 2015
  • After a reheating furnace installation, the modification of the size and the heat capacity is very difficult. Therefore, the development of design package tool is required for the computation on the correct specifications before the design and the installation. Prior to development of the design tool, a module that calculates the amount of heat loss of each part according to the specifications for determining the thermal efficiency of a continuous heating furnace was developed and applied to the oxy-fuel industrial furnace. Through this, the effects of fuel type, oxygen fraction and recirculation on the efficiency of the furnace of which the output is 110Ton/hour were analyzed. In oxy-fuel combustion condition, the efficiency was 15% higher than air combustion conditions. With the using COG(Coke Oven Gas) instead of LNG, the efficiency was slightly increased. In the air combustion condition, the efficiency was increased about 33% with the preheated air. But, in oxy-fuel condition, the amount of exhaust gas was reduced, so the efficiency was increased about 7%.