• Title/Summary/Keyword: 에너지 전달

Search Result 1,516, Processing Time 0.026 seconds

2DEG Transport Analysis in AlGaAs/GaAs Interface by MONTE-CARLO Method (MONTE-CARLO 방법에 의한 AlGaAs/GaAs 계면의 전자 전달특성 분석)

  • Nam, Seung-Hun;Jung, Hak-Ki;Kim, Bong-Ryul
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.2
    • /
    • pp.94-101
    • /
    • 1989
  • Transport properties of 2DEG at AlGaAs/GaAs interface such as average electron energy, flight distance, each valley occupancy ratio, average electron velocity for various fields are investigated by MONTE-CARLO method. As the electric field increases, more electrons transit drastically from (000) valley to (000) upper valley. This phenomenon shows the nonstationary effect such as velocity overshoot. The duration of the transient decreases from about 1.4 psec for electric field E = 7KV/cm to about 0.7 psec for 12KV/cm. The average electron velocity during transient transport in 2DEG is about 8 times the steady-state velocity for E = 12KV/cm at room temperature. In comparison with bulk GaAs the peak velocity in the 2DEG is higher than that in even pure bulk GaAs at electric field E = 7 KV/cm. On the basis of the fact that the electrons in the 2DEG have larger peak velocity and shorter transient time of velocity than those in the bulk GaAs, it is suggested that the device with 2DEG may obtain higher mobility than that with bulk GaAs.

  • PDF

Monte Carlo Study Using GEANT4 of Cyberknife Stereotactic Radiosurgery System (GEANT4를 이용한 정위적 사이버나이프 선량분포의 계산과 측정에 관한 연구)

  • Lee, Chung-Il;Shin, Jae-Won;Shin, Hun-Joo;Jung, Jae-Yong;Kim, Yon-Lae;Min, Jeong-Hwan;Hong, Seung-Woo;Chung, Su-Mi;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.192-200
    • /
    • 2010
  • Cyberknife with small field size is more difficult and complex for dosimetry compared with conventional radiotherapy due to electronic disequilibrium, steep dose gradients and spectrum change of photons and electrons. The purpose of this study demonstrate the usefulness of Geant4 as verification tool of measurement dose for delivering accurate dose by comparing measurement data using the diode detector with results by Geant4 simulation. The development of Monte Carlo Model for Cyberknife was done through the two-step process. In the first step, the treatment head was simulated and Bremsstrahlung spectrum was calculated. Secondly, percent depth dose (PDD) was calculated for six cones with different size, i.e., 5 mm, 10 mm, 20 mm, 30 mm, 50 mm and 60 mm in the model of water phantom. The relative output factor was calculated about 12 fields from 5 mm to 60 mm and then it compared with measurement data by the diode detector. The beam profiles and depth profiles were calculated about different six cones and about each depth of 1.5 cm, 10 cm and 20 cm, respectively. The results about PDD were shown the error the less than 2% which means acceptable in clinical setting. For comparison of relative output factors, the difference was less than 3% in the cones lager than 7.5 mm. However, there was the difference of 6.91% in the 5 mm cone. Although beam profiles were shown the difference less than 2% in the cones larger than 20 mm, there was the error less than 3.5% in the cones smaller than 20 mm. From results, we could demonstrate the usefulness of Geant4 as dose verification tool.

Comparison of Measured and Calculated Carboxylation Rate, Electron Transfer Rate and Photosynthesis Rate Response to Different Light Intensity and Leaf Temperature in Semi-closed Greenhouse with Carbon Dioxide Fertilization for Tomato Cultivation (반밀폐형 온실 내에서 탄산가스 시비에 따른 광강도와 엽온에 반응한 토마토 잎의 최대 카복실화율, 전자전달율 및 광합성율 실측값과 모델링 방정식에 의한 예측값의 비교)

  • Choi, Eun-Young;Jeong, Young-Ae;An, Seung-Hyun;Jang, Dong-Cheol;Kim, Dae-Hyun;Lee, Dong-Soo;Kwon, Jin-Kyung;Woo, Young-Hoe
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.401-409
    • /
    • 2021
  • This study aimed to estimate the photosynthetic capacity of tomato plants grown in a semi-closed greenhouse using temperature response models of plant photosynthesis by calculating the ribulose 1,5-bisphosphate carboxylase/oxygenase maximum carboxylation rate (Vcmax), maximum electron transport rate (Jmax), thermal breakdown (high-temperature inhibition), and leaf respiration to predict the optimal conditions of the CO2-controlled greenhouse, for maximizing the photosynthetic rate. Gas exchange measurements for the A-Ci curve response to CO2 level with different light intensities {PAR (Photosynthetically Active Radiation) 200µmol·m-2·s-1 to 1500µmol·m-2·s-1} and leaf temperatures (20℃ to 35℃) were conducted with a portable infrared gas analyzer system. Arrhenius function, net CO2 assimilation (An), thermal breakdown, and daylight leaf respiration (Rd) were also calculated using the modeling equation. Estimated Jmax, An, Arrhenius function value, and thermal breakdown decreased in response to increased leaf temperature (> 30℃), and the optimum leaf temperature for the estimated Jmax was 30℃. The CO2 saturation point of the fifth leaf from the apical region was reached at 600ppm for 200 and 400µmol·m-2·s-1 of PAR, at 800ppm for 600 and 800µmol·m-2·s-1 of PAR, at 1000ppm for 1000µmol of PAR, and at 1500ppm for 1200 and 1500µmol·m-2·s-1 of PAR levels. The results suggest that the optimal conditions of CO2 concentration can be determined, using the photosynthetic model equation, to improve the photosynthetic rates of fruit vegetables grown in greenhouses.

Evaluation of the effect of a Position Error of a Customized Si-Bolus Produced using a 3D-Printer: Cervical Cancer Radiation Treatment (3D 프린터를 이용하여 제작한 맞춤형 Si-Bolus의 위치 오차 효과 평가: 자궁경부암 방사선 치료)

  • Seong Pyo Hong;Ji Oh Jeong;Seung Jae Lee;Byung Jin Choi;Chung Mo Kim;Soo Il Jung;Yun Sung Shin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.7-13
    • /
    • 2023
  • Purpose: In this study, we evaluated the effect of using a customized bolus on dose delivery in the treatment plan when cervical cancer protruded out of the body along with the uterus and evaluated reproducibility in patient set-up. Materials & Methods: The treatment plan used the Eclipse Treatment Planning System (Version 15.5.0, Varian, USA) and the treatment machine was VitalBeam (Varian Medical Systems, USA). The radiotherapy technique used 6 MV energy in the AP/PA direction with 3D-CRT. The prescribed dose is 1.8 Gy/fx and the total dose is 50.4 Gy/28 fx. Semiflex TM31010 (PTW, Germany) was used as the ion chamber, and the dose distribution was analyzed and evaluated by comparing the planned and measured dose according to each position movement and the tumor center dose. The first measurement was performed at the center by applying a customized bolus to the phantom, and the measurement was performed while moving in the range of -2 cm to +2 cm in the X, Y, and Z directions from the center assuming a positional error. It was measured at intervals of 0.5 cm, the Y-axis direction was measured up to ±3 cm, and the situation in which Bolus was set-up incorrectly was also measured. The measured doses were compared based on doses corrected to CT Hounsfield Unit (HU) 240 of silicon instead of the phantom's air cavity. Result: The treatment dose distribution was uniform when the customized bolus was used, and there was no significant difference between the prescribed dose and the actual measured value even when positional errors occurred. It was confirmed that the existing sheet-type bolus is difficult to compensate for irregularly shaped tumors protruding outside the body, but customized Bolus is found to be useful in delivering treatment doses uniformly.

  • PDF

A Study on the Deterioration Process of 22kV Power Cables in Operation (운전 중인 상태에 있는 22kV 전송선로 케이블의 열화 과정해석에 대한 연구)

  • Lee, Kwan-Woo;Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.3
    • /
    • pp.127-133
    • /
    • 2013
  • As an essential part of current industrial society, electric power energy is contantaly increasing in pace with the development of science and technology. In order to meet the demand of electric power, power facilities which take care of the higher voltage and bigger capacity is required. To produce and supply electric power on a sound basis the electric facilities should operate with reliability. To prevent disasters in advance, the high quality facilities should be manufactured, and a constant management should be done. When the power facilities cause accidents, the result is huge national deficits. Since the power facilities play a pivotal role in the key industry of national infrastructures of they should operate for a long time in maintaining a stable state, and the accidents can be prevented in advance. The lifetime of a power cable is considered to be 30 years at the time of manufacture, but in real fields, accidents of cable occur 8-12 years from the start of operation, resulting in a heavy loss of properties. In this paper, we will show that we have found out the cause and process of the deterioration of 22kV cable systems in operation. The result is that the process of deterioration does not follow the Weibull distribution only ; but rather, after the heat deterioration the Weibull distributed deterioration comes, then the cable is destroyed due to the partial discharge resulting from the Weibull distributed deterioration.

Interfacial Evaluation of Single-Carbon Fiber/Phenolic and Carbon Nanotube-Phenolic Composites Using Micromechanical Tests and Electrical Resistance Measurements (미세역학시험법과 전기저항 측정을 이용한 탄소섬유/페놀수지 및 탄소나노튜브-페놀수지 복합재료의 계면특성 평가)

  • Wang, Zuo-Jia;Kwon, Dong-Jun;Gu, Ga-Young;Park, Jong-Kyoo;Lee, Woo-Il;Park, Joung-Man
    • Journal of Adhesion and Interface
    • /
    • v.11 no.4
    • /
    • pp.149-154
    • /
    • 2010
  • Interfacial evaluation was investigated for single-carbon fiber/phenolic and carbon nanotube (CNT)-phenolic composites by micromechanical technique and electrical resistance measurement combined with wettability test. Compressive strength of pure phenol and CNT-phenolic composites were compared using Broutman specimen. The contact resistance of CNT-phenolic composites was obtained using a gradient specimen by two and four-point methods. Surface energies and wettability by dynamic contact angle measurement were measured using Wilhelmy plate technique. Since hydrophobic domains are formed as heterogeneous microstructure of CNT in the surface, the dynamic contact angle exhibited more than $90^{\circ}$. CNT-phenolic composites exhibited a higher apparent modulus than neat phenolic case due to better stress transferring effect. Work of adhesion, $W_a$ between single-carbon fiber and CNT-phenolic composites exhibited higher than neat phenolic resin due to the enhanced viscosity by CNT addition. It was consistent with micro-failure patterns in microdroplet test.

Synthesis of Cerium Doped Yttrium Aluminum Garnet Hollow Phosphor Based on Kirkendall Effect

  • Kim, Min-Jeong;Suphasis, Roy;Gong, Dal-Seong;Jeong, Hyeon-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.185-185
    • /
    • 2012
  • 중공 발광 나노 물질은 특유의 구조적 특성(낮은 밀도, 높은 비표면적, 다공성 물질, 낮은 열팽창계수 등)과 광학적 성질을 이용하여 디스플레이 패널, 광결정, 약물전달체, 바이오 이미징 라벨 등의 다양한 적용이 가능하다. 이러한 적용에 있어 균일한 크기와 형태의 중공 입자는 필수 조건으로 여겨진다. 지금까지 합성된 중공 발광 입자에는 BaMgAl10O17 : Eu2+-Nd3+, Gd2O3 : Eu3+, $EuPO_4{\cdot}H_2O$과 같은 것들이 있으나 크기 조절이 어렵고, 그 균일성이 확보되지 못하였다. 균일한 크기의 중공 발광 입자를 만들기 위해 SiO2나 emulsion을 템플릿으로 이용하여 황화카드뮴, 카드뮴 셀레나이드 중공 입자를 합성한 예가 있으나, 양자점의 독성으로 인하여 바이오분야 응용에는 적합하지 않다. YAG는 모체로써 형광체에서 가장 많이 이용되는 물질로, 화학적 안정성과 낮은 독성, 높은 양자 효율 등 많은 장점을 갖고 있다. 특히 세륨이 도핑된 YAG형광체의 경우 WLED, 신틸레이터, 바이오산업에 적용이 가능하다. 그러나 지금까지 중공 YAG:Ce3+형광체를 합성한 예가 없었다. 본 연구에서는 단분산 수화 알루미늄 (Al(OH)3) 입자 위에 세륨이 도핑 된 이트륨 베이직 카보네이트 ($Y(OH)CO_3$)를 균일하게 코팅한 후 열처리를 하여 균일한 크기의 Y3Al5O12:Ce3+(YAG) 중공 입자를 합성하였다. 열처리 온도에 따른 고분해능 투과 전자 현미경(HRTEM), X-선 회절(XRD), 고분해능 에너지 분광법(HREDX) 분석결과, 중공 YAG: Ce3+입자는 Kirkendall 효과에 의해 형성됨을 확인하였다. 전계방사형 주사 전자 현미경(FE-SEM) 측정을 통해, 열처리 후에도 입자의 크기와 형태가 균일함을 확인하였으며, 공초점 현미경 관찰을 통해 중공 형태를 명확히 확인 할 수 있었다. Photoluminescence (PL) 분광법과 형광 수명 이미징 현미경(FLIM)을 이용한 광 특성 분석결과, 합성된 입자는 400-500 nm에서 흡수 파장 (456 nm에서 최대 강도)과 500-700 nm 범위의 발광 파장(544 nm에서 최대 강도)을 나타냈고, 상용 YAG: Ce3+(70 ns)에 준하는 74 ns의 잔광 시간(decay time)이 측정되었다. 단분산 수화 알루미늄 입자의 크기를 조절하여 최종 합성된 YAG: Ce3+의 크기를 조절할 수 있었다. 지름 약 600 nm의 Al(OH)3를 사용한 경우, $1,300^{\circ}C$에서 열처리를 한 후 평균 지름 590 nm의 중공입자를 합성하였고, 약 170 nm의 Al(OH)3를 이용하여, 더 낮은 온도인 $1,100^{\circ}C$에서의 열처리를 통해 평균지름 140 nm의 중공 YAG: Ce3+입자를 합성하였다. 본 연구를 통하여 합성된 균일한 크기의 YAG 중공입자는 LED와 같은 광전변환 소자 및 다기능성 바이오 이미징 등의 나노바이오 소자 분야에 활용될 수 있음이 기대된다.

  • PDF

Development of Commercial-scaled Pervaporation Hollow Fiber Membrane System for High Pressure and High Temperature Applications (고온 고압용 상업적 규모의 중공사 투과증발 막시스템 개발)

  • Yeom, Choong Kyun;Kang, Kyeong Log;Kim, Joo Yeol;Ahn, Hyo Sung;Kwon, Konho
    • Membrane Journal
    • /
    • v.23 no.4
    • /
    • pp.257-266
    • /
    • 2013
  • The main purpose of this study is to develop a commercial scale of pervaporative process equipped with hollow fiber membrane modules, being able to effectually purify organic solvent at high temperature well over its boiling point under high vapor pressure. Three constituent technologies have been developed; 1) to fabricate braid-reinforced hollow fiber membrane stable in high pressure and high temperature application, 2) to design and fabricate a commercial scale of hollow fiber membrane module, and 3) to design and fabricate a pilot scale of pervaporation equipment system. The developed hollow fiber membrane possesses a membrane performance superior to the membrane of Sulzer (Germany) which is the most-well known for pervaporation process, and the membrane module equips hollow fiber membranes of $4.6m^2$ and the pervaporation system can treat organic liquid at 200 L/h, which is based on the dehydration of 95 wt% isopropyl alcohol (IPA). Since the membrane module is designed to flow in and pass through the inside of individual hollow fiber membrane, not to involve both the formation of feed's dead volume observed in flat-sheet membrane module and the channeling of feed occurring inside hollow fiber bundle which lower membrane performance seriously, it showed excellent separation efficiency. In particular, the module is inexpensive and has less heat loss into its surrounding, in compared with flat-sheet membrane module. In addition, permeant can be removed effectively from the outer surface of hollow fiber membrane because the applied vacuum is conveyed uniformly through space between fibers into respective fiber, even into one in the middle of the hollow fiber bundle in which the space between fibers is uniform in distance. Since the hollow fiber membrane pervaporation system is the first one ever developed in the world, our own unique proprietary technology can be secured, preoccupying technical superiority in export competitive challenges.

Internal Components Arrangement of MR Damper Landing Gear for Cavitation Prevention (캐비테이션 방지를 위한 MR 댐퍼형 착륙장치의 내부 형상 배치에 대한 연구)

  • Joe, Bang-Hyun;Jang, Dae-Sung;Hwang, Jai-Hyuk
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.5
    • /
    • pp.33-41
    • /
    • 2020
  • The landing gear of an aircraft is a device that absorbs and dissipates shock energy transmitted from the ground to the fuselage. Among the landing gears, the semi-active MR damper landing gear is supposed to show high-shock absorption efficiency under various landing conditions and secure the stability when out of control. In the case of the MR damper landing gear using an annular channel rather than orifice, Amesim, a commercial multi-physics program, is considered as more useful than the conventional two-degree-of-freedom model because the damping force generated by the pressure drop through the flow annular path can cause cavitation in the low-pressure chamber of the MR damper with a specific internal structure. In this paper, the main dynamic characteristics of the MR damper landing gear with an annular type flow path structure has been analyzed under the condition of cavitation. Based on the analysis results using Amesim, a design guideline for the MR damper flow path that prevents cavitation has been proposed based on the modification of the arrangement of internal components of the damper. The guideline was verified through a drop simulation.

Audio Quality Enhancement at a Low-bit Rate Perceptual Audio Coding (저비트율로 압축된 오디오의 음질 개선 방법)

  • 서정일;서진수;홍진우;강경옥
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.6
    • /
    • pp.566-575
    • /
    • 2002
  • Low-titrate audio coding enables a number of Internet and mobile multimedia streaming service more efficiently. For the help of next-generation mobile telephone technologies and digital audio/video compression algorithm, we can enjoy the real-time multimedia contents on our mobile devices (cellular phone, PDA notebook, etc). But the limited available bandwidth of mobile communication network prohibits transmitting high-qualify AV contents. In addition, most bandwidth is assigned to transmit video contents. In this paper, we design a novel and simple method for reproducing high frequency components. The spectrum of high frequency components, which are lost by down-sampling, are modeled by the energy rate with low frequency band in Bark scale, and these values are multiplexed with conventional coded bitstream. At the decoder side, the high frequency components are reconstructed by duplicating with low frequency band spectrum at a rate of decoded energy rates. As a result of segmental SNR and MOS test, we convinced that our proposed method enhances the subjective sound quality only 10%∼20% additional bits. In addition, this proposed method can apply all kinds of frequency domain audio compression algorithms, such as MPEG-1/2, AAC, AC-3, and etc.