• 제목/요약/키워드: 에너지해석

검색결과 4,405건 처리시간 0.028초

Effect of Carrier Confinement and Optical Properties of Two-dimensional Electrons in Al0.3Ga0.7N/GaN and Al0.3Ga0.7N/GaN/Al0.15Ga0.85N/GaN Heterostructures (Al0.3Ga0.7N/GaN 및 Al0.3Ga0.7N/GaN/Al0.15Ga0.85N/GaN 이종접합 구조에서 운반자 구속 효과와 이차원 전자가스의 광학적 특성)

  • Kwack, H.S.;Lee, K.S.;Cho, H.E.;Lee, J.H.;Cho, Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • 제17권4호
    • /
    • pp.359-364
    • /
    • 2008
  • We have investigated optical and structural properties of $Al_{0.3}Ga_{0.7}N$/GaN and $Al_{0.3}Ga_{0.7}N/GaN/Al_{0.15}Ga_{0.85}N/GaN$ heterostructures (HSs) grown by metal-organic chemical vapor deposition, by means of Hall measurement, high-resolution X-ray diffraction, and temperature- and excitation power-dependent photoluminescence (PL) spectroscopy. A strong GaN band edge emission and its longitudinal optical phonon replicas were observed for all the samples. At 10 K, a 2DEG-related PL peak located at ${\sim}\;3.445\;eV$ was observed for $Al_{0.3}Ga_{0.7}N$/GaN HS, while two 2DEG peaks at ${\sim}\;3.42$ and ${\sim}\;3.445\;eV$ were observed for $Al_{0.3}Ga_{0.7}N/GaN/Al_{0.15}Ga_{0.85}N/GaN$ HS due to the additional $Al_{0.15}Ga_{0.85}N$ layers. Moreover, the emission intensity of the 2DEG peak was higher in $Al_{0.3}Ga_{0.7}N/GaN/Al_{0.15}Ga_{0.85}N/GaN$ HS than in $Al_{0.3}Ga_{0.7}N$/GaN HS probably due to an effective confinement of the photo-excited holes by the additional $Al_{0.15}Ga_{0.85}N$ layers. The 2DEG-related emission intensity decreased with increasing temperature and disappeared at temperatures above 150 K. To investigate the origin of the new 2DEG peaks, the energy-band structure for multiple AlGaN/GaN HSs were simulated and compared with the experimental data. As a result, the observed high- and low-energy peaks of 2DEG can be attributed to the spatially-separated 2DEG emissions formed at different AlGaN/GaN heterointerfaces.

A study on design process for public space by users behavioral characteristics (이용자 행태 특성에 의한 공용공간의 디자인 프로세스 연구)

  • 김개천;김범중
    • Archives of design research
    • /
    • 제17권1호
    • /
    • pp.89-98
    • /
    • 2004
  • A systemic approach to behavior on the basis of human psychology is needed for behavior-centered space design. Also, the recognition that human and environment, in all, have complementarity is needed- human and space shall be understood as a general phenomenon, supposing interaction. Design of behavior-oriented space means configuration and coordination of physical subjects as well as understanding, analysis and reflection of psychological and behavioral phenomena. It is analysis of a private individual as well as understanding of interaction between human groups, as well. In respect of space recognition, analysis not on material movement but on energy circulation and variable is important. It means that the understanding of user's behavior and psychology does not orient reasonable purpose just for convenience. That is, such understanding intends to understand behavioral patterns and psychological phenomena between space and human beyond the decomposition of structure of human and space into physical elements and the design based on standardized data. Thereby, more human-oriented space design might be implemented by the understanding of behavioral essence. Also, a user-centered design process from another viewpoint might be created, and the general amenity among man, space and environment - better environmental quality - might be produced. For this, the consciousness of human activity that is, activity system shall be ahead of it, and the approaches for design shall be implemented into a process not in predictive ideas but in semi-scientific system. On the basis of the above view, this study was attempted to investigate the orientation of design to recognize space as another life, and explore a process where it is drawn into a design language on the basis of human behavior. If the essence of space behavior and the activity system are analyzed through user observation and it is reflected upon a space design program and then developed into a formative language, a new design process on human and environment might be produced. In conclusion, the reflection of user's behavior and psychology into design, contrary to existing public space design based on physical data, can orient quality improvement of human life and ultimately be helpful to the proposition, 'humanization of space'.

  • PDF

Spectral Induced Polarization Characteristics of Rocks in Gwanin Vanadiferous Titanomagnetite (VTM) Deposit (관인 함바나듐 티탄철광상 암석의 광대역 유도분극 특성)

  • Shin, Seungwook
    • Geophysics and Geophysical Exploration
    • /
    • 제24권4호
    • /
    • pp.194-201
    • /
    • 2021
  • Induced polarization (IP) effect is known to be caused by electrochemical phenomena at interface between minerals and pore water. Spectral induced polarization (SIP) method is an electrical survey to localize subsurface IP anomalies while injecting alternating currents of multiple frequencies into the ground. This method was effectively applied to mineral exploration of various ore deposits. Titanomagnetite ores were being produced by a mining company located in Gonamsan area, Gwanin-myeon, Pocheon-si, Gyeonggi-do, South Korea. Because the ores contain more than 0.4 w% vanadium, the ore deposit is called as Gwanin vanadiferous titanomagnetite (VTM) deposit. The vanadium is the most important of materials in production of vanadium redox flow batteries, which can be appropriately used for large-scale energy storage system. Systematic mineral exploration was conducted to identify presence of hidden VTM orebodies and estimate their potential resources. In geophysical exploration, laboratory geophysical measurement of rock samples is helpful to generate reliable property models from field survey data. Therefore, we performed laboratory SIP data of the rocks from the Gwanin VTM deposit to understand SIP characteristics between ores and host rocks and then demonstrate the applicability of this method for the mineral exploration. Both phase and resistivity spectra of the ores sampled from underground outcrop and drilling cores were different of those of the host rocks consisting of monzodiorite and quartz monzodiorite. Because the phase and resistivity at frequencies below 100 Hz are mainly dependent on the SIP characteristics of the rocks, we calculated mean values of the ores and the host rocks. The average phase values at 0.1 Hz were ores: -369 mrad and host rocks: -39 mrad. The average resistivity values at 0.1 Hz were ores: 16 Ωm and host rocks: 2,623 Ωm. Because the SIP characteristics of the ores were different of those of the host rocks, we considered that the SIP survey is effective for the mineral exploration in vanadiferous titanomagnetite deposits and the SIP characteristics are useful for interpreting field survey data.

Detrended Fluctuation Analysis of Sleep Electroencephalogram between Obstructive Sleep Apnea Syndrome and Normal Children (소아기 수면무호흡증 환자와 정상 대조군 수면 뇌파의 탈경향변동분석)

  • Kim, Eui-Joong;Ahn, Young-Min;Shin, Hong-Beom;Kim, Jong-Won
    • Sleep Medicine and Psychophysiology
    • /
    • 제17권1호
    • /
    • pp.41-49
    • /
    • 2010
  • Unlike the case of adult obstructive sleep apnea syndrome (OSAS), there was no consistent finding on the changes of sleep architecture in childhood OSAS. Further understanding of the sleep electroencephalogram (EEG) should be needed. Non-linear analysis of EEG is particularly useful in giving us a new perspective and in understanding the brain system. The objective of the current study is to compare the sleep architecture and the scaling exponent (${\alpha}$) from detrended fluctuation analysis (DFA) on sleep EEG between OSAS and normal children. Fifteen normal children (8 boys/7 girls, 6.0${\pm}4.3$2.2 years old) and twelve OSAS children (10 boys/2 girls, 6.4${\pm}4.3$3.4 years old) were studied with polysomnography (PSG). Sleep-related variables and OSAS severity indices were obtained. Scaling exponent of DFA were calculated from the EEG channels (C3/A2, C4/A1, O1/A2, and O2/A1), and compared between normal and OSAS children. No difference in sleep architecture was found between OSAS and normal controls except stage 1 sleep (%) and REM sleep latency (min). Stage 1 sleep (%) was significantly higher and REM latency was longer in OSAS group (9.3${\pm}4.3$4.3%, 181.5${\pm}4.3$59.9 min) than in controls (5.6${\pm}4.3$2.8%, 133.5${\pm}4.3$42.0 min). Scaling exponent (${\alpha}$) showed that sleep EEG of OSAS children also followed the 'longrange temporal correlation' characteristics. Value of ${\alpha}$ increased as sleep stages increased from stage 1 to stage 4. Value of ${\alpha}$ from C3/A2, C4/A1, O1/A2, O2/A1 were significantly lower in OSAS than in control (1.36${\pm}4.3$0.05 vs. 1.41${\pm}4.3$0.04, 1.37${\pm}4.3$0.04 vs. 1.41${\pm}4.3$0.04, 1.37${\pm}4.3$0.05 vs. 1.41${\pm}4.3$0.05, and 1.36${\pm}4.3$0.07 vs. 1.41${\pm}4.3$0.05, p<0.05). Higher stage 1 sleep (%) in OSAS children was consistent finding with OSAS adults. Lower $'{\alpha}'$ in OSAS children suggests decrease of self-organized criticality or the decreased piling-up energy of brain system during sleep in OSAS children.

  • PDF

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • 제31권1호
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF