코넬 공과대학 기숙사 사례를 통한 대학 기숙사의 패시브 하우스 기술 적용에 관한 연구 (A Study on the Passive House Technology Application of University Dormitory through The House at Cornell Tech)

  • 김홍민;오형석;류수훈
    • 교육시설 논문지
    • /
    • 제25권4호
    • /
    • pp.11-18
    • /
    • 2018
  • Global warming is happening now and inevitable. Everyone knows that immediate action should be taken to slow it down, but uncertain about the effective solution. Despite global efforts to reduce greenhouse gas emissions, sea levels are rising gradually. In 2013, Cornell University announced the Climate Action Plan(CAP) to make the campus greener, to reduce waste, and to ensure efficient use of resources. In particular, they set a goal of reducing energy use by 2050 and making carbon emissions to zero. Accordingly, the purpose of this study is to analyse the case of the master plan of Cornell Tech campus and its major buildings. Mainly, The House, faculty and student housing of Cornell Tech and the world tallest certified passive house, will be the main precedent that shows the architectural planning of passive house. Passive house technology, which was thought to be possible only in single-family houses, can be applied to high-rise buildings. If any passive house technology of The House project is actively introduced into the dormitory projects of domestic universities that are about to be built or renovated, it will be a good opportunity for the university to take the lead in preparing for global warming.

콤팩트형 태양열/지열히트펌프 하이브리드 냉난방 및 급탕 시스템 개발 및 성능분석 (The Development and Performance Analysis of Compact Type Solar Thermal/Ground Coupled Heat Pump Hybrid System for Heating, Cooling and Hot water)

  • 백남춘;정선영;윤응상;이경호
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.59-67
    • /
    • 2012
  • In this study,the compact type solar thermal and ground coupled heat pump hybrid system for space heating/cooling and hot water supply has been developed. This hybrid system was installed in Zero Energy Solar House(ZeSH) in KIER for the demonstration. The thermal performance and operational characteristics of this hybrid system were analysed especially. The results are as follows. (1) This hybrid system was designed in order to address the existing disadvantages of solar thermal/ground coupled heat pump system. For this design, all parts except solar collector and ground coupled heat pump were integrated into a single product in a factory. The compact type unit includes two buffer tanks, an expansion tank, pumps, valves, a controller, etc. This system has an advantage of easy installation with simple plumbing work even in narrow space. (2) The thermal charging and discharging time of the buffer tanks and its characteristics by ground coupled heat pump, and heat pump COP according to geo-source temperature and buffer storage temperature have been studied. This system was found to meet well to the heat load without any other auxiliary heating equipment. (3) The operating hours of the ground coupled heat pump as a backup device of solar thermal can be reduced significantly by using solar heat. It was also found that the minimum heating water supply setting temperature and maximum cooling water supply setting temperature make an influence on the heat pump COP. The lower heating water and the higher cooling water temperature, the higher COP. In this respect, the hybrid system's performance can be improved in ZeSH than conventional house.

창호의 광학적 특성에 따른 ZeSH의 일사취득 및 난방부하에 관한 민감도 분석 (A Sensitivity Analysis about Solar Heat Gain and Heating Load of ZeSH According to Optical Characteristics of Window system)

  • 손선우;백남춘;서승직
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.66-71
    • /
    • 2009
  • To reduce the building energy consumption, the major advanced nations are conducting actively many researches on so called a "self-sufficient building(or other words zero energy building)" which can support its required energy by itself. Given this background, KIER(Korea Institute of Energy Research) built full size test-bed of the zero energy solar house in early 2002, and has studied on the self-sufficient heating load up to now. We analyse the sensitivity between the heating load and the solar radiation gain according to the change the effective transmittance of windows. The authors classified 9 cases by solar transmittance of glass. The results demonstrate the solar radiation amount is 0.466 MWh from the eastern zone of Fl.,1(the first floor), 0.332 MWh from Fl.,2(the second floor), 1.194 MWh form the southern zone of F1., and 0.822 MWh from the southern zone of Fl.,2 on the case 1(each cases are classified by window types). On the case 9, the solar radiation amount is 3.127 MWh, 2.662 MWh, 8.799 MWh and 6.078 MWh from the same condition. For the Fl.,1, the amount of Heat Load that is saved per year ranged 10.5 to 48 %, and the reduction was anywhere from 0.2 to 17.9% for Fl.,2

  • PDF

국내 친환경 업무용 건축물의 디자인에 대한 비교 연구 (A Comparative Analysis of Designs in Low Carbon Environment-Friendly Business Buildings)

  • 강연주;김문덕
    • 한국실내디자인학회논문집
    • /
    • 제23권3호
    • /
    • pp.153-163
    • /
    • 2014
  • The eco-friendly elements are important for new construction and renovation and redevelopment of the buildings. The green buildings are related with minimizing environmental pollution and how to live with nature throughout the entire process of demolishing and building. The purpose of this paper is to study on eco-friendly business buildings in the trend of mandatory green building certification system. The analysis of this paper is comparative studies on practices at eleven domestic eco-friendly business buildings through site survey on design framework of green buildings. The design framework of eleven this buildings is six kinds of skills on technical, renewable, ecological, cultural, healthy, social. The eleven this buildings in the new & renewable energy and IT technology of technical sector are satisfied with the framework. But, domestic most advanced eco-friendly business buildings are placed difference between almost the two times on the lower buildings at comparative evaluation. The three of this buildings are gratified rainwater harvesting and waste recycling systems for renewable and recycle. The buildings have an excellent aspects of technology and ecology. The benefits of this buildings are related with future compulsory zero energy house to take technical advantage of renewable energy. However, the buildings reflecting the regional culture types is insufficient. The buildings should be supplemented as follows. This buildings are need to have the social enhancement programs and design for convenient space of community residents, through health and comfort of on workplace. Moreover, this buildings have features of coexisting with human beings and nature friendly with the aim of realizing the sustainable development. The social enhancement programs through regional cultural aspects with ecology are related with individual and community livings in harmony, non-hierarchical communal lifes. The development of the cultural aspects provide for consensus about the local community and creating sustainable communities. Thus, The buildings are to have energy saving, pleasant and healthy living environment and interactive individual and community livings in harmony.