• 제목/요약/키워드: 에너지부하

검색결과 1,520건 처리시간 0.032초

반도체 클린룸용 에어와셔 외기공조시스템의 에너지소비량에 관한 실험적 연구 (An Experimental Study on Energy Consumption of Air Washer Outdoor Air Conditioning Systems for Semiconductor Manufacturing Clean Rooms)

  • 김기철;김형태;송근수;유경훈;손승우;신대건;박덕준
    • 설비공학논문집
    • /
    • 제24권4호
    • /
    • pp.297-305
    • /
    • 2012
  • In recent large-scale semiconductor manufacturing clean rooms, the energy consumption of outdoor air conditioning systems to heat, humidify, cool and dehumidify incoming outdoor air represents about 45% of the total air conditioning load required to maintain a clean room environment. Therefore, the energy performance evaluation and analysis of outdoor air conditioning systems is useful for reducing the outdoor air conditioning load for a clean room. In the present study, an experiment was conducted to compare the energy consumption of outdoor air conditioning systems with a simple air washer, an exhaust air heat recovery type air washer and a DCC return water heat recovery type air washer. It was shown from the present lab-scale experiment with an outdoor air flow of 1,000 $m^3/h$ that the exhaust air heat recovery type and DCC return water heat recovery type air washer outdoor air conditioning systems were more energy-efficient for the summer and winter operations than the simple air washer outdoor air conditioning system and furthermore, the DCC return water heat recovery type one was the most energy-efficient in the winter operation.

센서 네트워크에서 신뢰성 있는 시각 동기 프로토콜 (Reliable Time Synchronization Protocol in Sensor Networks)

  • 황소영;정연수;백윤주
    • 한국통신학회논문지
    • /
    • 제31권3A호
    • /
    • pp.274-281
    • /
    • 2006
  • 센서 네트워크에서 시각 동기 기술은 동기 기반 통신 프로토콜 개발뿐만 아니라, 암호화 기술에서의 타임 스탬프, 타 노드들로부터의 같은 이벤트 중복 감지 인식, beamforming, 기록된 이벤트들의 발생 순서 구분 등 다양한 응용을 위해 필요하다. 본 논문에서는 센서 네트워크에서 신뢰성 있는 시각 동기 프로토콜(RTSP: Reliable Time Synchronization Protocol)을 제안한다. 제안하는 기법은 깊이가 낮은 계층적 트리 형태의 네트워크 토폴로지를 구성하여 동기 오류를 줄이고, 후보 부모 노드의 정보를 유지함으로써 노드의 이동, 에너지 소진 및 물리적 결함으로 인한 토폴로지 변화에 대응한다. 시뮬레이션을 통한 성능 분석 결과는 RTSP가 기존의 TPSN(Timing-sync Protocol for Sensor Networks)과 비교하여 동기 정확도에 있어 20% 가량 향상됨을 보인다. 또한, 네트워크 내 노드의 결함으로 토폴로지 변화 시 동기화에 필요한 메시지 수를 $20%{\sim}60%$ 감소시키는 효과를 보인다. 노드의 무선 전송 거리를 서로 다르게 설정했을 경우에도 RTSP의 통신 부하는 TPSN에 비해 최대 40% 이상 감소된다.

서해 도서지역의 풍력-디젤 하이브리드 발전에 대한 경제성 분석 (An Economic Feasibility Study of Wind-Diesel Hybrid Power Systems for an Island in the Yellow Sea)

  • 이탁기;남용윤;김재동;한정우
    • 한국항해항만학회지
    • /
    • 제35권5호
    • /
    • pp.381-385
    • /
    • 2011
  • 본 연구에서는 최대 발전량이 500kW인 서해 도서의 풍력-디젤 하이브리드 발전시스템에 대한 경제성 분석을 수행하였다. 이를 위해 해당 도서에 대한 연간 전력 부하 변동치와 바람 데이터를 수집하고 분석하였으며, 풍력을 포함하여 신재생 에너지에 대한 하이브리드 최적화 모델로 미국의 NREL에서 개발한 Homer 프로그램을 이용하였다. 풍력-디젤 하이브리드 발전시스템의 경제성을 판단하기 위해 풍속과 경유 가격을 변수로 하는 민감도 해석도 수행하였다. 그 결과, 현재의 조건에서는 경제성이 낮았으나, 풍속이 초속 3미터가 넘거나 경유 가격이 리터당 2.4달러를 초과할 경우 대상지역에도 풍력-디젤 하이브리드 발전시스템이 경제성을 갖는 것으로 평가되었다.

역전 유동층을 이용한 관군 내에서의 슬러리아이스 생성에 관한 연구 (A Study on Formation of Slurry Ice by using the Reversing Flow in a Bundle of Tube)

  • 오철;최영규
    • 한국항해항만학회지
    • /
    • 제35권5호
    • /
    • pp.365-370
    • /
    • 2011
  • 최근 지구 온난화와 더불어 급격한 기후 변화 등으로 여름철 주간 냉방 수요가 급격히 증가하고 있다. 이에 따른 전력 수요량 또한 증가하고 있다. 이런 이유로 세계적으로 에너지 이용 효율 향상에 대한 관심이 높아지고 있고, 최근 국내 및 국외의 축냉시스템을 이용한 주간 전력 피크값을 최소화 하는 연구개발과 실제 적용 사례가 늘어나고 있다. 빙축열시스템의 경우 그 경제적 효과가 높아 그 관심이 높아지고 있는 추세이다. 축냉시스템은 주간 냉방에 사용하는 냉열을 야간에 만들어 탱크에 저장해 두었다가 그것을 낮에 이용함으로써, 갑작스런 부하 증가에 적절히 대응할 수 있는 등 여러 가지 장점을 갖고 있다. 본 실험에서는 슬러리아이스 생성을 위해 냉각표면에서 생성된 슬러리아이스를 분리시키기 위해 유체보다 밀도가 낮은 역전유동 물질을 삽입하여 역전 유동층을 형성하였으며, 역전유동층의 유동에 의해 관군으로 구성되어 있는 냉각튜브 표면에 빙부착이 심화되기 전에 얼음 입자를 분리시켜 수 내지 수십 미크론 단위의 슬러리아이스를 생성하도록 하였다.

마이크로 변위제어 시스템의 압전 액츄에이터 구동을 위한 스위칭 증폭기 성능 분석 (Performance Evaluation of Switching Amplifier in Micro-positioning Systems with Piezoelectric Actuator)

  • 박종후;백종복;조보형;최성진
    • 전력전자학회논문지
    • /
    • 제14권1호
    • /
    • pp.62-71
    • /
    • 2009
  • 본 논문에서는 마이크로 변위제어 시스템의 적층형 압전 액츄에이터를 위한 스위칭 증폭 구동회로의 구동방법을 제시하고 성능을 평가하였다. 이 증폭기는 압전 액츄에이터로부터 임의의 용량성 부하에 저장된 에너지를 효율적으로 회수할 수 있는 장점이 있다. 기존의 전압 되먹임 제어 방식은 100mHz의 정현파 기준치 추종시, 총 왜곡율이 -32dB (${\approx}2.5%$)로서, 액츄에이터의 전압과 변위 사이의 비선형적 관계로 인한 오차발생을 확인할 수 있었다. 이를 개선하기 위하여 전하 제어방식을 살펴보았는데, 기존의 직렬 커패시터를 연결하는 대신, 변위 기준치를 미분하고, 이를 출력전류와 비교하는 방식으로 개선하였다. 전하량 되먹임 제어 적용시 변위의 왜곡률은 약 -52dB (${\approx}0.25%$)로서 선형성이 매우 우수한 특성을 보임을 알 수 있다. 마지막으로 살펴본 직접 변위 제어 방식은 구현상의 복잡성으로 성능의 한계가 존재함을 알 수 있다.

BES 프로그램을 이용한 국내 대표적 대형온실의 에너지 부하 예측 (Prediction of Greenhouse Energy Loads using Building Energy Simulation (BES))

  • 이성복;이인복;홍세운;서일환;;권경석;하태환;한창평
    • 한국농공학회논문집
    • /
    • 제54권3호
    • /
    • pp.113-124
    • /
    • 2012
  • Reliable estimation of energy load inside the greenhouse and the selection of cooling and heating facilities are very important preceding factors to save energy as well as initial and maintenance costs of operating a greenhouse. Recently, building energy simulation (BES) technique to simulate a model similar to the actual conditions through a variety of dynamic simulation methods, and predict and analyze the flow of energy is being actively introduced and developed. As a fundamental research to apply the BES technique which is mainly used for analysis of general buildings, to greenhouse, this research designed four types of naturally-ventilated greenhouses using one of commercial programs, TRNSYS, and then compared and analyzed their energy load properties, by applying meteorological data collected from six regions in Korea. When comparing the greenhouse load of each region depending on latitude and topographical characteristics through simulation, Chuncheon had nearly 9~49 % higher heating load per year than other regions, but its annual cooling load was the reverse to it. Except for Jeju, 1-2W type greenhouses in five regions showed about 17 % higher heating load than a widespan type greenhouse, and 1-2W type greenhouses in Chuncheon, Suwon, Cheongju, Daegu, Cheonju and Jeju had 23 %, 20 %, 17 %, 16 %, 18 % and 20 % higher cooling load respectively than a wide span-type one. Glasshouse and vinyl greenhouse showed 8~11 % and 10~12 % differences respectively in heating load, while 2~10 % and 7~10 % differences in cooling load respectively.

부분 스위칭 PFC 모듈을 이용한 가정용 에어컨 전원장치 (The Power System for Home Appliance Air-Conditioner using Partial Switching Power Factor Correction Module)

  • 서기영;문상필
    • 조명전기설비학회논문지
    • /
    • 제18권6호
    • /
    • pp.183-190
    • /
    • 2004
  • 본 논문은 냉난방 인버터 에어컨용 전원시스템에 역률개선 회로인 부분 스위칭 PFC 모듈을 적용하여 입력의 역률 개선 및 전류의 고조파 성분을 최소화하여 IEC555-2규정을 만족하는 입력 전원부를 설계하여 인덕터부하에 적용되는 회로 설계시의 문제점들을 해결 할 수 있는 방안들을 제시하였다. 그리고 출력전압의 상승을 억제하면서 전류파형을 개선하는 방법 및 부분 스위칭 PFC회로를 제안하여 스위칭 횟수를 적게 함으로써 압축기의 모터에 인가 할 수 있는 전압을 상승시켜 모터 적정 운전 전압을 확립하였으며, 효율이나 경제성 및 전자 노이즈 등의 문제점들을 해결하였다. 그리고 에어컨의 소비 전력을 줄일 수 있다. 이상의 결과에서 시스템 총합 운전에너지 효율이 상승되는 것을 확인하는 모든 사항은 시뮬레이션과 실험을 통하여 그 타당성을 입증했다.

Elliptic curve기반 센서네트워크 보안을 위한 곱셈 최적화 기법 (Multiplication optimization technique for Elliptic Curve based sensor network security)

  • 서화정;김호원
    • 한국정보통신학회논문지
    • /
    • 제14권8호
    • /
    • pp.1836-1842
    • /
    • 2010
  • 센서네트워크는 유비쿼터스 환경을 실현할 수 있는 기술로서, 최근 무인 경비 시스템이나 에너지 관리, 환경 모니터링, 홈 자동화, 헬스케어와 같은 다양한 분야에 적용 가능하다. 하지만 센서네트워크의 무선 통신 특성은 도청과 전송 메시지에 대한 위변조, 서비스 거부 공격에 취약하다. 현재 센서네트워크 상에는 안전한 통신을 위해 ECC(elliptic curve cryptography)를 통한 PKC(public key cryptography)암호화 기법이 사용된다. 해당 기법은 RSA에 비해 작은 키길이를 통해 동일한 암호화 강도를 제공하기 때문에 제한된 성능을 가진 센서상의 적용에 적합하다. 하지만 ECC에 요구되어지는 높은 부하 때문에 센서상의 구현을 위해서는 성능개선이 필요하다. 본 논문에서는 센서 상에서의 ECC를 가속화하기 위해 ECC연산의 핵심연산인 곱셈에 대한 최적화 기법을 제안한다.

입상 활성탄에 의한 Rhodamin-B의 흡착 열역학, 동력학 및 등량 흡착열에 관한 연구 (Adsorption Thermodynamics, Kinetics and Isosteric Heat of Adsorption of Rhodamin-B onto Granular Activated Carbon)

  • 이종집
    • 공업화학
    • /
    • 제27권2호
    • /
    • pp.199-204
    • /
    • 2016
  • 입상 활성탄을 사용하여 수용액으로부터 Rhodamine-B 염료의 흡착에 대해 조사하였다. 회분식 실험은 흡착제의 양, pH 초기농도와 접촉시간과 온도를 흡착변수로 사용하여 수행하였다. 흡착평형자료는 Langmuir 등온식에 잘 맞았다. 평가된 Langmuir 분리계수($R_L$ = 0.0164~0.0314)로부터 이 흡착공정이 적절한 처리방법이 될 수 있음을 알았다. 흡착속도실험결과는 유사 1차 반응속도식에 잘 맞는 것으로 나타났다. 음수값의 Gibbs 자유에너지(-4.51~-13.44 kJ/mol)와 양수값의 엔탈피(128.97 kJ/mol)는 흡착이 자발적이고 흡열공정으로 진행된다는 것을 나타냈다. 등량흡착열은 흡착된 염료분자들의 측면상호작용에 따라 표면부하량이 증가할수록 커졌다.

LED 조명장치 구동용 200[W]급 하프브리지 LLC 직렬공진형 컨버터 (200[W] Half-Bridge LLC Series Resonant Converter for driving LED Lamp)

  • 한우용;박효식
    • 한국산학기술학회논문지
    • /
    • 제11권11호
    • /
    • pp.4483-4488
    • /
    • 2010
  • LED는 다른 광원에 비해 동작수명이 길고, 친환경적이며, 에너지 효율이 높은 장점을 가지고 있다. 최근 LED 기술의 발전으로 인해 고휘도, 고용량의 LED가 개발됨에 따라, 표시장치에만 적용되던 LED를 조명장치에도 적용하는 기술이 확산되고 있다. 파워 LED는 동작의 안정성 및 신뢰성을 확보하기 위해 구동전류를 일정한 값 이하로 유지하는 전류제한기능이 필요한데, 본 논문에서는 전류제한기능을 포함한 하프브리지 LLC 직렬공진형 컨버터를 제안한다. 하프브리지 LLC 직렬공진형 컨버터는 다른 공진형 컨버터에 비해 상대적으로 입력전압 및 출력부하 범위가 광범위한 장점이 있으며, 변압기의 누설인덕턴스를 공진인덕터로 이용할 수 있기 때문에 마그네틱 소자를 줄일 수 있는 장점이 있다. 전류제한기능 및 역률개선기능을 포함하고 있는 출력전압 DC24[V], 200[W]급의 LED 조명장치 구동용 하프브리지 LLC 직렬공진형 컨버터의 설계 및 실험을 통해 타당성을 입증하였다.