• Title/Summary/Keyword: 양수효율

Search Result 222, Processing Time 0.027 seconds

An Efficient DCT Calculation Method Based on SAD (SAD 정보를 이용한 효율적인 DCT 계산 방식)

  • 문용호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.6C
    • /
    • pp.602-608
    • /
    • 2003
  • In this paper, we propose an efficient DCT calculation method for fast video encoding. We show that the SAD obtained in the motion estimation and compensation process is decomposed into the positive and negative terms. Based on a theoretical analysis, it is shown that the DCT calculation is classified into 4 cases - DCT Skip, Reduced_DCT1 , Reduced_DCT2, and original DCT- according to the positive and negative terms. In the proposed algorithm, one of 4 cases is used for DCT in order to reduce the computational complexity. The simulation results show that the proposed algorithm achieves computational saving approximately 25.2% without image degradation and computational overhead.

A Study on Vulnerability Assessment for Field Drought Using TOPSIS (TOPSIS를 이용한 밭 가뭄에 대한 관정 취약성 평가 연구)

  • Shin, Hyung Jin;Lee, Gyu Min;Lee, Jae Nam;Park, Chan gi;Lee, Gyusang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.346-346
    • /
    • 2021
  • 본 연구는 농업지역의 가뭄 발생에 대하여 활용되는 관정의 효율적 관리를 목표로 우선관리가 필요한 취약지역을 선정하는 방안을 수립하였다. 특히 한국에서는 논 위주의 농업 생산기반정비가 진행되어 왔으나 최근 경제성장과 소득증대에 따른 농산물 소비 구조의 변화로 다양한 밭 작물경작이 증가하여 밭 관개시설물에 대한 정비가 요구되고 있다. 따라서 가뭄 대응을 위한 밭작물의 용수공급 시설물인 관정에 대한 취약성 평가를 통하여 관리의 목표와 우선관리 지역의 선정이 필요하다. 가뭄에 대한 관정 취약성 평가는 최근 널리 사용되는 다기준의사결정 기법인 TOPSIS를 적용하였으며, 한국 전역 158개의 시, 군을 평가대상으로 한다. 평가 인자는 관정능력 및 효율에 긍정적 영향을 주는 강수량, 지하수위, 관정 당 양수량과 부정적 영향을 주는 경지면적, 연속무강우일수, 민간관정 비율을 선정하였다. 평가결과로부터 관정 당 양수량과 상수도 보급율이 관정 효율 취약성 평가를 통한 우선 관리 순위선정에 주요한 영향을 주는 것으로 분석되었다.

  • PDF

Capacity Modulation of a Ground Source Multi-Heat Pump in the Part Load Condtions (축열형 지열원 냉난방 시스템의 단기 성능 특성 연구)

  • Kim, Namtae;Cho, Chanyong;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.119-119
    • /
    • 2010
  • 무한 지속 가능한 지열 에너지를 활용한 공조시스템인 지열원 냉난방 시스템은 기존의 공조 시스템보다 열원이 안정적이기 때문에 높은 효율과 우수한 성능을 가지므로, 기후변화협약 대응의 주요수단으로서 기술개발과 보급이 증대되고 있다. 본 연구에서는 대수층 축열 지열원 열펌프 시스템에 대한 실증 연구를 통하여 대수층 축열 지열원 열펌프 시스템의 하절기 냉방 성능을 분석하였다. 대수층 축열 냉난방 시스템은 주입정과 양수정의 2개의 우물공이 설치되어 있으며, 겨울 난방 운전 중에 한 개의 우물공으로부터 지하수를 열펌프로 유입한 후 낮은 온도의 지하수를 타 우물공에 축열하고, 하절기에 겨울에 저온으로 축열된 우물공으로부터 지하수를 열펌프로 유입하여 온도가 증가된 지하수를 타 우물공에 주입한다. 즉, 계절별로 열펌프에서 생성된 냉수와 온수의 대수층 축열을 위하여 계절별로 주입정과 양수정이 바뀌게 된다. 본 연구의 대수층 축열 지열원 열펌프 시스템의 2009년 8월의 주요일자별 시스템 운전 중의 평균 냉방 열펌프 유닛 COP와 냉방 시스템 COP는 각각 4.7과 3.4이상의 우수한 성능을 나타냈다. 또한, 모든 일자에 대하여 외기온도가 $31.6^{\circ}C$$22^{\circ}C$까지 변화가 크게 나타났지만 열펌프 유닛 COP와 시스템 COP의 변화는 미소하였다. 이는 양수정으로부터의 지중 순환수가 운전기간 중에 $17.5^{\circ}C$로 일정하게 유지되었기 때문이다. 양수정과 주입정 사이에 5개의 관측공을 설치하였으며, 양수정 측에 인접한 관측공의 온도는 거의 변화가 없었으며, 단기간이지만 널리 사용되고 있는 수직밀폐형 시스템과 달리 지속적인 냉방운전 중의 양수 온도의 증가는 발생하지 않아 안정적인 성능을 나타냈다. 주입정에 인접한 모니터링 홀의 온도는 심도가 깊은 곳의 온도가 낮은 곳보다 높게 나타났다. 이는 냉방 운전 시 열펌프 유닛의 실외열교환기에서 지중 순환수가 냉매로부터 열을 취득하여 온도가 상승하면서 주입정측에 온열이 축열이 진행되었기 때문으로 분석되며, 하절기의 냉방 운전 시간이 증가할 경우 축열 효과는 더욱 증가할 것으로 예상된다. 양수정과 주입정 중간의 모니터링 홀의 온도는 2009년 8월 가동 중에 온도변화는 없었는데, 이는 양수정과 주입정 사이의 열간섭이 발생하지 않았기 때문으로 분석된다. 일자별로 운전 중의 열펌프 유닛 COP는 차이가 없었지만, 운전 및 정지 시간을 모두 포함한 시스템 소비전력과 냉방용량을 모두 합산하여 산정한 일일 평균 냉방 열펌프 유닛 COP와 냉방 시스템 COP는 일자별로 다소 차이가 발생하였는데, 이는 각 일자별로 열펌프 유닛 가동율의 차이로 인하여 열펌프 유닛 가동 전에 먼저 작동되는 지중순환펌프의 운전 소비전력의 차이와 열펌프의 단속운전 시의 열손실과 추거 소비전력의 차이 때문이다.

  • PDF

In Situ Iron-manganese Removal by an Oxygenated Water Injection-and-extraction Technique in a Riverbank Filtration System (산소수 주입-양수 기법을 통한 강변여과수 내 철/망간 저감 평가)

  • Yi, Myeong-Jae;Cha, Jang-Hwan;Jang, Ho-June;Ahn, Hyun-suk;Hahn, Chan;Kim, Yongsung
    • The Journal of Engineering Geology
    • /
    • v.25 no.3
    • /
    • pp.339-347
    • /
    • 2015
  • Riverbank filtration has been suggested as a cost-effective method for improving water quality. However, high concentrations of Fe2+ and Mn2+ cause problems for the use of water and the maintenance of facilities. We evaluated the effectiveness and efficiency of an Fe2+ and Mn2+ removal technique based on the in situ injection of highly oxygenated water at a site on the Anseong River, between Anseong City and Pyeongtaek City, Gyeonggi Province. The removal process consists of three steps: injection, resting, and extraction. Results show that the removal efficiency increases with repeated application of the process. The amount of Fe-reduced drinking water satisfying water regulations (limit, 0.3 mg/L Fe) obtained using oxygenated water injection was five times higher than the amount of injected oxygenated water. Levels of Mn2+ were also reduced following the injection of oxygenated water.

Event Handling of Schedule Management System in BioPlace (BioPlace의 일정관리 이벤트 처리)

  • 박희종;문남두;안건태;박양수;이명준
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.10c
    • /
    • pp.334-336
    • /
    • 2003
  • BioPlace의 일정관리 시스템은 특정 연구 분야의 연구자들 사이에 효과적이고 능률적인 일정관리를 지원하기 위한 웹기반 환경이다. 웹을 통한 공동작업의 경우 개인은 물론 그룹의 일정을 보다 효율적이고 체계적으로 수립하고 공지하는 것이 바람직하다. 본 논문에서는 이러한 요구를 충족시키기 위하여 BioPlace의 일정관리 작업에서 발생하는 이벤트의 흐름과 관련 데이터의 분석을 통한 데이터의 효율적인 관리방법을 기술하였다. 일정관리 작업에 사용되는 데이터의 효율적인 관리와 처리를 위한 방법으로 세션과 Request 객체를 이용하였다.

  • PDF

Analysis of Stream Depletion due to Groundwater Pumping in Variable Stream Stages Using an Analytical Model (해석적 모형을 이용한 지하수 양수 및 하천수위 변화에 따른 하천수 감소 특성 분석)

  • Lee, Jeongwoo
    • The Journal of Engineering Geology
    • /
    • v.29 no.4
    • /
    • pp.439-449
    • /
    • 2019
  • To prevent the drying-out of streams and to make effective use of stream water and groundwater, it is necessary to evaluate the impact of groundwater pumping on nearby streams. To this end, stream depletion due to groundwater pumping should be investigated in terms of various hydraulic characteristics of the aquifer and stream. This study used the Baalousha analytical solution, which accounts for stream-stage variation over time, to analyze stream depletion due to groundwater pumping for cases where the stream level decreases exponentially and recovers after the decrease. For conditions such as an aquifer transmissivity of 10~100 ㎡ d-1, storage coefficient 0.05~0.3, streambed hydraulic conductance 0.1~1.0 m d-1, stream-well distance 100~500 m, and stage recession coefficient 0.1~1.0 d-1, the contribution of stream water (the dimensionless ratio of stream water reduction rate to groundwater pumping rate) was analyzed in cases where stream level change was considered. Considering the effect of stream-stage recession, the contribution of stream water is greatly reduced and is less affected by the stream-depletion factor, which is a function of the stream-to-well distance and hydraulic diffusivity. However, there is no significant difference in stream depletion under constant- and variable-stage recovery after recession. These results indicate that stream level control can distribute the relative impacts on stream water and aquifer storage during groundwater pumping

Evaluation of Underground Water Environmental Effects on Performance of the Geo-thermal Heat Pump (지열히트펌프 운영에 따른 지하수 환경영향 평가)

  • Kim, Jin-han;Park, Soo-Young;Park, Jung-Hwan;Kim, Tai-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.455-458
    • /
    • 2006
  • 본 연구는 자연에너지를 이용하는 모든 냉 난방기술 중에서 에너지효율이 가장 높은 것으로 알려져 있으며 에너지 자원이 부족하고 에너지비용이 높은 상황에서 반드시 필요한 기술인 지하수를 이용한 건물의 냉 난방을 수행하는 스탠딩컬럼웰 지열히트펌프 기술을 운영함에 따른 지하수에 미치는 환경영향을 평가하기 위해 수행되었다. 즉 스탠딩컬럼웰을 적용한 지열히트펌프 시설이 가동되고 있는 주변지역의 지하수질 및 지하수위의 변화를 평가하기 위하여 지하수 환경영향평가를 실시하였다. 연구결과, 히트펌프의 유입수 및 유출수, 그리고 주변 지역의 수질은 지하수 수질기준 및 공업용수, 생활용수 수질기준에 적합한 안정적인 수질을 나타내었으며, 시설 운영에 따른 지하수 오염은 거의 없는 것으로 판단된다. 또한 지열히트펌프에 이용되는 4개의 양수정에 의한 주변 지역의 지하수위 변화등의 영향을 예측하기 위하여 취수가 없는 상태와 양수정당 취수량을 $50m^3/day$로 증가시켰을 경우를 가정하여 지하수두를 분석한 결과 취수량을 증가시켰을 경우 지하수두가 약2,.2m 감소하는 것으로 나타나 조사지역내의 지하수 거동은 양수정 가동조건과 주변지역에 분포되어 있는 정천의 취수량 변화에 따라 민감하게 반응하는 것으로 나타났다.

  • PDF

A Study for Reducing Sea Water Intrusion in the Ground Water Dam Operation (지하댐 운영시 발생하는 염수침입 저감기법에 관한 연구)

  • Yun, Sang-Hoon;Park, Jae-Hyeon;Park, Chang-Kun
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.2
    • /
    • pp.97-108
    • /
    • 2004
  • Recently the ground-water development using the ground-water dam was proposed for the efficient use of the limited water resources especially for islands or seaside area. But in operating the ground-water dam adjacent to seaside an excessive pumping causes the sea-water intrusion which is caused by the drawdown of ground-water level. In this study, the effect of the recharging well method to reduce the sea-water intrusion was evaluated, and was applied to the downstream of the Ssangcheon ground-water dam site. The SUTRA model was used to simulate the salinity transport in the unsaturated and saturated zone. As the results, the effect of recharging method on the downstream of the ground-water dam was proven to be very efficient to reduce the salinity in the pumping well, and especially the best result was shown at the case that the recharging well is located at 40∼60m from the cutoff wall and the recharging rate is up to 6∼7%.

Study on Permeability, Optimum Yield and Long-term Stability in Alluvial Well with Filter Layer Change (충적우물에서 필터층 변화에 따른 투수특성, 적정양수량 및 장기적 안정성에 대한 연구)

  • Song, Jae-Yong;Lee, Sang-Moo;Choi, Yong-Soo;Kim, Ki-Joon;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.28 no.1
    • /
    • pp.101-115
    • /
    • 2018
  • This study was carried out to evaluate the effects of various filter conditions on unconfined aquifer (alluvial aquifer). We made model test device which has filter layer, pumping well and observation well which consist of sand layer and gravel layer to test. Step drawdown test and long term pumping tests were carried out using the device. The permeability characteristics of each test group were confirmed and the optimal yield was calculated. As a result of comparing the optimal yield of double filter and single filter in sand, dual-filter SD-300 was valued at 216.8 % higher final optimal yield than single-filter SS-300. Comparing the dual filter SD-300 and the single filter SS-100 with a thin filter layer, dual-filter SD-300 was valued at 709.2% higher final optimal yield than single-filter SS-300. As a result of analysis of optimal yield change over time, It was confirmed that the ratio of optimal yield of single filter and dual filter increase over time. In order to evaluate the long-term change in water intake efficiency, we considered the point at which the initial optimal yield was reduced by 50%. The dual filter SD-300 is about 351.1% higher than SS-300, which is the same thickness filter, and about 579.0% higher than SS-100. From these results, Assuming that the point at which the initial quantity of water intake is reduced to 50% is the well life, double filters are expected to increase their lifespan by about 3.5 times over single filters of the same thickness and by about 5.8 times over typical single filter. These results can be used to design wells to river bank filtration or filtered seawater. In addition, it is possible to clarify the effect of the double filter through the comparison with the future field test results.

Components for managing iPlace collaborative system (iPlace 협업지원 시스템의 관리 콤포넌트)

  • 이근웅;안건태;정명희;박양수;이명준
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2001.10c
    • /
    • pp.730-732
    • /
    • 2001
  • iPlace 협업지원 시스템은 웹 상에서 공동작업을 하는 그룹간의 정보관리 및 교환과 공유, 그리고 실시간 의사 소통 등을 지원하는 공동작업 시스템이다. 이 시스템의 기능이 다양해지고 각종 사용자의 요구 및 처리해야할 데이터가 증가함에 따라 이를 효율적이고 편리하게 관리할 수 있도록 도와주는 도구가 필요하다. 본 논문에서는 웹 상에서 iPlace 협업지원 시스템을 효율적으로 관리하기 위한 도구를 콤포넌트 기술을 기반으로 하여 개발하였다.

  • PDF