• Title/Summary/Keyword: 양방향 거리측정

Search Result 25, Processing Time 0.02 seconds

TLD Dosimetry in HDR Intracavitary Brachytherapy (고선량률 강내 근접치료시 열형광량계를 이용한 선량측정법)

  • Kim, Chang-Seon;Yang, Dae-Sik;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.109-116
    • /
    • 2000
  • One consideration of radiation delivery in cervical cancer is the complication of critical organs, e.g., bladder and rectum. The absorbed dose of bladder and rectum in HDR intracavitary brachytherapy is measured indirectly with TLD dosimetry A method for the complication reduction of bladder and rectum is suggested. For two-hundred cervical cancer patients, follow-up MRI images were reviewed and distances from cervical central axis to bladder and rectum and vaginal wall thickness were measured. The sealed TLDs were placed upon the gauze packing of the ovoids and the distances to the TLDs from the ovoid center were measured in the simulation film and actual doses of bladder and rectum were calculated. From published data, maximal tolerance doses of bladder and rectum were derived and based on the permissible doses per fraction in HDR brachytherapy the packing thicknesses were determined in both directions. The required minimal packing thicknesses for bladder and rectum were 0.43 and 0.92 cm, respectively. The results were compared with computer calculation using the Meisberger polynomial approach. It is our hope this study can be used for a guideline for users in clinic in estimating critical organ dose in bladder and rectum in HDR brachytherapy in vivo dosimetry.

  • PDF

Fault free Shortest Path routing on the de Bruijin network (드브르젼 네트워크에서 고장 노드를 포함하지 않는 최단 경로 라우팅)

  • Ngoc Nguyen Chi;Nhat Vo Dinh Minh;Zhung Yonil;Lee Sungyoung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.11B
    • /
    • pp.946-955
    • /
    • 2004
  • It is shown that the do Bruijn graph (dBG) can be used as an architecture for interconnection network and a suitable structure for parallel computation. Recent works have classified dBG based routing algorithms into shortest path routing and fault tolerant routing but investigation into fault free shortest path (FFSP) on dBG has been non-existent. In addition, as the size of the network increase, more faults are to be expected and therefore shortest path dBG algorithms in fault free mode may not be suitable routing algorithms for real interconnection networks, which contain several failures. Furthermore, long fault free path may lead to high traffic, high delay time and low throughput. In this paper we investigate routing algorithms in the condition of existing failure, based on the Bidirectional do Bruijn graph (BdBG). Two FFSP routing algorithms are proposed. Then, the performances of the two algorithms are analyzed in terms of mean path lengths and discrete set mean sizes. Our study shows that the proposed algorithms can be one of the candidates for routing in real interconnection networks based on dBG.

Depth Upsampling Method Using Total Generalized Variation (일반적 총변이를 이용한 깊이맵 업샘플링 방법)

  • Hong, Su-Min;Ho, Yo-Sung
    • Journal of Broadcast Engineering
    • /
    • v.21 no.6
    • /
    • pp.957-964
    • /
    • 2016
  • Acquisition of reliable depth maps is a critical requirement in many applications such as 3D videos and free-viewpoint TV. Depth information can be obtained from the object directly using physical sensors, such as infrared ray (IR) sensors. Recently, Time-of-Flight (ToF) range camera including KINECT depth camera became popular alternatives for dense depth sensing. Although ToF cameras can capture depth information for object in real time, but are noisy and subject to low resolutions. Recently, filter-based depth up-sampling algorithms such as joint bilateral upsampling (JBU) and noise-aware filter for depth up-sampling (NAFDU) have been proposed to get high quality depth information. However, these methods often lead to texture copying in the upsampled depth map. To overcome this limitation, we formulate a convex optimization problem using higher order regularization for depth map upsampling. We decrease the texture copying problem of the upsampled depth map by using edge weighting term that chosen by the edge information. Experimental results have shown that our scheme produced more reliable depth maps compared with previous methods.

Dose Distribution of Co-60 Photon Beam in Total Body Irradiation (Co-60에 의한 전신조사시 선량분포)

  • Kang, Wee-Saing
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.109-120
    • /
    • 1991
  • Total body irradiation is operated to irradicate malignant cells of bone marrow of patients to be treated with bone marrow transplantation. Field size of a linear accelerator or cobalt teletherapy unit with normal geometry for routine technique is too small to cover whole body of a patient. So, any special method to cover patient whole body must be developed. Because such environments as room conditions and machine design are not universal, some characteristic method of TBI for each hospital could be developed. At Seoul National University Hospital, at present, only a cobalt unit is available for TBI because source head of the unit could be tilted. When the head is tilted outward by 90$^{\circ}$, beam direction is horizontal and perpendicular to opposite wall. Then, the distance from cobalt source to the wall was 319 cm. Provided that the distance from the wall to midsagittal plane of a patient is 40cm, nominal field size at the plane(SCD 279cm) is 122cm$\times$122cm but field size by measurement of exposure profile was 130cm$\times$129cm and vertical profile was not symmetric. That field size is large enough to cover total body of a patient when he rests on a couch in a squatting posture. Assuming that average lateral width of patients is 30cm, percent depth dose for SSD 264cm and nominal field size 115.5cm$\times$115.5cm was measured with a plane-parallel chamber in a polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom of size 25cm wide and 30cm deep. Depth of dose maximum, surface dose and depth of 50% dose were 0.3cm, 82% and 16.9cm, respectively. A dose profile on beam axis for two opposing beams was uniform within 10% for mid-depth dose. Tissue phantom ratio with reference depth 15cm for maximum field size at SCD 279cm was measured in a small polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom with TLD chips inserted in holes on the largest coronal plane was bilaterally irradiated by 15 minute in each direction by cobalt beam aixs in line with the cross line of the coronal plane and contact surface of sections No. 27 and 28. When doses were normalized with dose at mid-depth on beam axis, doses in head/neck, abdomen and lower lung region were close to reference dose within $\pm$ 10% but doses in upper lung, shoulder and pelvis region were lower than 10% from reference dose. Particulaly, doses in shoulder region were lower than 30%. On this result, the conclusion such that under a geometric condition for TBI with cobalt beam as SNUH radiotherapy departement, compensators for head/neck and lung shielding are not required but boost irradiation to shoulder is required could be induced.

  • PDF

Song Themes and Variation of Yellow-throated Bunting (Emberiza elegans) (노랑턱멧새(Emberiza elegans)의 테마송과 변이)

  • Lee, Won-Ho;Kwon, Ki-Chung
    • Journal of Ecology and Environment
    • /
    • v.29 no.3
    • /
    • pp.219-225
    • /
    • 2006
  • To study song themes and variation of Yellow-throated Bunting, we obtained and analyzed recordings from 45 males breeding in 16 deciduous forests of 6 provinces. We classified the 3,245 songs into a total of 164 song themes and 1,024 song variants according to the identification on the base of difference(lexicon) in 640 syllable compositions. Males had one to six song themes and averaged 3.5 themes. No males shared an identical song theme. Males had $5{\sim}14$ syllables (ave. 9.4) in one song theme and males increased effectively their repertoire size by changing syllable composition (i.e. adding, deleting, or substituting one or more syllables) in a single song theme. The number of variants averaged 5.1 (range 1 to 31) per song theme. Individual variability was highest in the terminal elements of the song. In PCA, the 16 populations are clearly separated on Co. I based on shared syllable and on Co. II based on unique syllable. Similarity of songs based on shared syllables by distance coefficients, showed a pattern of concordance with geography. Pairwise similarity declined with increasing distance among recording sites. 16 different geographical regions by the syllable were divided in UPGMA tree.