• Title/Summary/Keyword: 양로드형 EHA

Search Result 3, Processing Time 0.022 seconds

Comparison of Force Control Characteristics between Double-Rod and Single-Rod Type Electro-Hydrostatic Actuators (II): Back-Drivability (양로드형과 편로드형 EHA의 힘 제어 특성 비교(II): 역구동성)

  • Kim, Jong Hyeok;Hong, Yeh Sun
    • Journal of Drive and Control
    • /
    • v.14 no.4
    • /
    • pp.17-22
    • /
    • 2017
  • In this study, the back-drivability of the single-rod and double-rod type EHAs (Electro-Hydrostatic Actuators) was compared by computer simulation and experiments. The back-drivability of EHAs exhibit non-linear behavior like their force tracking performance. In case of the double-rod type EHA, the back-drivability was mostly influenced by the bulk modulus of oil that changes with the working pressure due to entrapped air. The back-drivability of the single-rod type EHA was directly affected by the operation states of its pilot-operated check valves, while the asymmetrical piston geometry and the non-linear bulk modulus of oil also made the dynamic response in building up the cylinder pressure dependent on the operating conditions.

Comparison of Force Control Characteristics Between Double-Rod and Single-Rod Type Electro-Hydrostatic Actuators (I): Tracking Performance (양로드형과 편로드형 EHA의 힘 제어 특성 비교(I): 추종 성능)

  • Kim, Jong Hyeok;Hong, Yeh Sun
    • Journal of Drive and Control
    • /
    • v.14 no.4
    • /
    • pp.9-16
    • /
    • 2017
  • In this study, the force tracking performance of the single-rod and double-rod type EHAs (Electro-Hydrostatic Actuators) was compared by computer simulation and experiments. The force-controlled EHAs exhibit non-linear behavior that are significantly dependent on operation conditions. The investigation focused on localizing the parameters that provide significant rise to the non-linearity. For this, the single-rod and double-rod type EHAs were mathematically expressed to derive their linear models. In parallel, they were modeled by a commercial simulation program including non-linear properties based on experimental results. It was shown that the dependency of the bulk modulus of oil with entrapped air on working pressure dominated the non-linearity in force control performance in case of the double-rod type EHA. The force control of the single-rod type EHA was influenced by much more elements. Besides the asymmetrical piston geometry and the non-linear bulk modulus of oil, its pilot-operated check valves made it dependent not only on the magnitude of reference input but also on its direction.

Force Fighting Suppressive Technique of Dual Redundant Asymmetric Tandem Electro-Hydrostatic Actuator for Aircraft (항공기용 이중화 비대칭형 직렬 전기-정유압 구동기의 Force Fighting 억제 기법)

  • Song, Woo Keun;Kim, Sang Seok;Choi, Jeong Seok;Lee, JungUn;Lee, Jong Cheol;Lee, Jun won;Choi, Jong Yoon
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.5
    • /
    • pp.62-69
    • /
    • 2022
  • EHA (Electro-Hydrostatic Actuator) is more energy efficiency than a centralized hydraulic system. In particular, the EHA used for aircraft has a redundant design in preparation for failure scenario. Also, due to the aircraft's internal space limitation, the actuator's length must be optimized. Therefore, a series configuration of double rod and single rod cylinder is advantageous. However, due to the asymmetry of the cross-sectional area of the piston, the force fighting phenomenon between the two cylinder areas occurs during redundant operation with a general control system. In this paper, the force fighting phenomenon of redundant EHA was simulated. A controller with load compensation and a force control-based position controller as a method to suppress its stimulation