• Title/Summary/Keyword: 양단지지

Search Result 68, Processing Time 0.034 seconds

Evaluation of Compressive Strength of Assembled Column System Reinforced with Cross-Arms and Stayed Struts (수평재 및 사재로 보강된 조립기둥시스템의 압축강도 평가)

  • Kim, Kyung Sik;Park, Hyun Yong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.6
    • /
    • pp.2169-2179
    • /
    • 2013
  • The compressive strengths of simply supported columns may be significantly increased by reinforcing them with an assemblage of cross-arms and stayed struts connecting both ends of the columns and the cross-arm members. The purpose of the stayed struts and cross-arms is to introduce partial restraints against translation and rotation, thereby decreasing the effective buckling length of the column. In this study, buckling strengths of the assembled column system have been quantitatively evaluated from the theoretical methods based on both the equivalent spring model and the stiffness matrix formulation. And the results were compared with those from elastic/inelastic analysis using a finite element analysis package program, ABAQUS, for verification purpose. Expected compressive strength curves have been proposed for the assembled column system as a function of slenderness ratio of the simply supported column.

The Study on Piezoresistance Change Ratio of Cantilever type Acceleration Sensor (지지조건이 압저항 가속도 센서의 민감도에 미치는 영향 평가)

  • Shim J.J.;Han G.J.;Han D.S.;Lee S.W.;Kim T.H.;Lee S.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1381-1384
    • /
    • 2005
  • In these days, the piezoresistive material has been applied to various sensors in order to measure the change of physical quantities. But the relationship between the sensitivity of a sensor and the position and size of piezoresistor has rarely been studied. Therefore, this paper was focused on the distribution of the resistance change ratio on the diaphragm and bridge surface where piezoresistor would be formed, and proposed the proper size and position of piezoresistor with which the sensitivity of sensor was increased. As the width of mass and boss was increased, the distance between piezoresistors was closed and the maximum value of resistance change ratio was decreased by the increase of the structure stiffness. And according to the increment of seismic mass size, the value of resistance change ratio is decreased by increase of the structure stiffness. Y directional piezoresistor is formed in the position of $100\mu{m}\;apart\;from\;cantilever\;edge\;and\;length\;of\;that\;is\;800\mu{m}$.

  • PDF

Analysis of Dynamic Behavior and Balancing of High Speed Spindle (고속 스핀들의 동적거동과 밸런싱 해석)

  • Koo, Ja-Ham;Kwon, Soon-Goo;Kim, Jong-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.238-244
    • /
    • 2017
  • A spindle with a built-in motor can be used to simplify the structure of a machine tool system, but the rotor inevitably has unbalanced mass. This paper presents an analysis of the dynamic behavior. The spindle was used in a CNC lathe and investigated using the finite element method and transfer matrices. The high-speed spindle can be very sensitive to the rotation of an unbalanced mass, which has a harmful effect on many machine tools. Thus, a balancing procedure was performed with a spindle-bearing system for the CNC lathe by numerical analysis. The balancing was performed through the influence coefficient method, and the whirl orbit radii before and after balancing were compared to evaluate the effects. The results show that the rotational speed of the spindle seriously affects the whirl responses of the spindle. The whirl responses were also affected by other factors, such as the unbalanced mass and bearing stiffness. The balancing of the assembled spindle model significantly reduced the whirl orbit magnitude.

Application of FRP-Concrete Composite Deck to Cable Stayed Bridge (FRP-콘크리트 합성 바닥판의 사장교 적용)

  • Cho, Keun-Hee;Park, Sung-Yong;Kim, Sung-Tae;Kim, Byung-Suk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.217-220
    • /
    • 2008
  • A modified FRP-concrete composite deck applicable to cable stayed bridge with long girder-to-girder span is proposed, and its design and economical efficiency are presented. The existing FRP-concrete composite deck has low section stiffness due to adoption of GFRP panel with low elastic modulus, which arrives at difficulty in meet of serviceability limit such as deck deflection. So a new-type FRP-concrete composite deck, named precast FRP-concrete deck, is developed by extensioning concrete at the both ends of FRP-concrete composite deck, which brings the effect of reduction of net span length of deck. Compared to the existing FRP-concrete composite deck this modified deck has the advantage of increasing span length but slightly increases self weight. For this type of deck the section optimization is carried out for the cases of simply supported on girder and composite to girder. The optimized deck was applied to cable stayed bridge with a center span length of 540m, and as a result it is verified that PFC deck can be applied efficiently to cable stayed bridge due to reduction of quantity of upper structure.

  • PDF

Development of Lightweight Piezo-composite Curved Actuator (곡면형 압전 복합재료 작동기 LIPCA 개발)

  • Park, Ki-Hoon;Yoon, Kwang-Joon;Park, Hoon-Cheol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.5
    • /
    • pp.94-100
    • /
    • 2002
  • This paper is concerned with the development, and performance test of LIPCA (Lightweight Piezo-composite Curved Actuator) that is lighter than other conventional piezo-composite type actuators. LIPCA is composed of top fiber composite layers with a high modulus and low CTE (Coefficient of Thermal Expansion), a middle PZT cermaic wafer, and base layers with a high modulus and high CTE. The performance of each actuator was evaluated using an actuator test system consisting of an actuator supporting jig, a high voltage actuating power supplier, and a non-contact laser measuring system. The simply supported condition actuator was excited by the power supplier with 1.0Hz cycle and up to $100\sim400V_{pp}$. The displacement at the center point of actuator was measured with non-contact laser displacement measuring system, It has been shown that the LIPCA-C2 can 34% decrease in mass and 13% increase in displacement compared to THUNDER.

Determination of Eigenvalues of Sinusoidally Tapered Members by Finite Element Method (유한요소법을 이용한 정현상으로 taper진 부재의 고유치 산정)

  • Lee, Soo-Gon;Kim, Soon-Chul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.13 no.1
    • /
    • pp.87-95
    • /
    • 2000
  • The two eigenvalues (elastic critical load and natural frequency of lateral vibration) of sinusoidally tapered bats with simply supported ends were determined by the finite element method. For the convenience of structural engineers who are engaged in the structural design or vibration analysis of tapered beam-columns, eigenvalue coefficients were expressed by simple algebraic equations. The validity of each algebraic equation was confirmed by the value of unity for each correlation coefficient. The influence of axial thrust on the lateral vibration frequency was also investigated. For this purpose, the axial thrust was increased successively and the corresponding frequency was calculated. The approximate linear relationship between the axial thrust and the square of the frequency was confirmed lot each of the tapered members.

  • PDF

Investigation of the Lateral Acoustic Signal Detection Using by Two Fabry-Perot Fiber Optic Sensor Array (두 개의 Fabry-Perot 광섬유 센서 배열을 이용한 횡방향 음압 감지 특성 연구)

  • Lee, Jong kil
    • 대한공업교육학회지
    • /
    • v.31 no.1
    • /
    • pp.185-199
    • /
    • 2006
  • In this paper, to detect lateral direction sound pressure fiber optic sensor using Fabry-Perot interferometeric sensor array was fabricated and experimented. This parallel sensor array composed of one light source and the light split into each sensor using directional coupler and to see the output signal the array system do not need any digital signal processor. As a lateral direction sound source arbitrary sound frequency of 100Hz, 200Hz, and 655Hz using by nondirectional speaker were applied to the array sensor which installed on $60cm{\times}60cm{\times}60cm$ latticed structure. The detected signals from the two sensors were analyzed in the time and frequency domains. It was confirmed that the suggested sensor array detected applied sound source well but there were a little amplitude differences in between the sensors. Because the sensor supported simply at both ends theoretical analysis was performed and its solution was suggested. To compare the theoretical and experimental results arbitrary sound frequency of 2kHz was applied to the sensor array. It shows that experimental results was good agreement with theoretical results.

ITER 블랑켓 시험모듈(TBM)의 액체형 증식재 성능 시험용 루프 설계 및 제작

  • Yun, Jae-Seong;Lee, Dong-Won;Bae, Yeong-Deok;Kim, Seok-Gwon;Hong, Bong-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.281-281
    • /
    • 2010
  • ITER 블랑켓 시험모듈(TBM)의 액체형 증식재 성능 시험용 루프의 설계를 완료하였고 현재시험용 루프를 제작 및 설치중이다. 액체형 증식재 성능 시험용 루프의 핵심 구성 부품인 액체 저장용 탱크, 전자석, EM 펌프들과 이들 장치들의 전원장치 및 제어장치를 제작 완료하였다. 액체형 증식재 성능 시험용 루프 설치를 위한 데크를 제작하였으며, 제작된 실험 데크의 총 지지하중은 10 톤 이상이다. 루프설치대 위에 성능 시험용 루프가 설치되며 루프 설치대는 $3\;m\;{\times}\;2.4\;m$ 의 직사각형으로 제작되었으며, 실험 종료 및 유지 보수 시 액체증식재의 drain을 고려하여 전체 루프는 각도 조절이 가능하도록 제작되었다. 루프내의 유량을 측정하기 위한 유량계, 전자석 자장의 변화에 따른 압력의 변화를 측정하기 위한 차압센서가 전자석의 양단에 설치되며, 시험용 루프에 흐르는 액체금속(PbLi) 및 루프관의 온도를 측정하기 위한 열전대가 설치된다. 루프 설치대를 기울였을 때 루프의 최상부에 액체금속 저장고 및 레벨센서를 설치하여 루프 내에 액체금속이 가득 채워졌는지를 레벨센서로 확인하며 루프 내에 잔존하는 기체가 저장고를 통하여 외부로 배출되게 하였다. 액체형 증식재 성능 시험용 루프 설치 후 실험은 고체 상태의 PbLi를 액체 저장용 탱크에 장착한 후 탱크의 열선의 온도 제어에 의한 PbLi의 용융점 확인, 시험용 루프에서의 전자펌프 성능 평가 등의 시험의 기본적인 실험을 수행한 후 자기장 환경에서 MHD 평가, 증식재의 순도 유지, 구조재의 부식 등의 시험을 수행할 예정이다.

  • PDF

A study on the correlation between the degree of elasticity uniformity and the dynamic performance in the overhead contact lines (전차선로 탄성도 불균일율과 동역학적 성능과의 관계에 대한 연구)

  • Park, Sa-Hoon;Kwon, Sam-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.502-502
    • /
    • 2007
  • A catenary system should be designed to have an uniform elasticity over a span in order to maintain the lowest possible loss of contact between a pantograph and a contact wire. A elasticity uniformity of a catenary can be regarded as a important design factor used for predicting the current collection performance for a catenary. There are a couple of formulas to calculate the degree of elasticity uniformity of a catenary according to the literature survey. The effectiveness of these formulas is reviewed by performing catenary elasticity and loss of contact analysis for various different configurations of catenary systems using a beam element based FEM program. The results reveals that these formulas are not suitable to predict the current collection performance for a catenary. Therefore, a new formula based on the standard deviation of the elasticity over a span is proposed in this study. The analysis results show that the new formula for an elasticity uniformity of a catenary is very effective in predicting the current collection performance for a catenary.

  • PDF

Development of Impact Factor Response Spectrum with Tri-Axle Moving Loads and Investigation of Response Factor of Middle-Small Size-RC Slab Aged Bridges (3축 이동하중을 고려한 충격계수 응답스펙트럼 개발 및 중소규모 RC 슬래브 노후교량 응답계수 분석)

  • Kim, Taehyeon;Hong, Sanghyun;Park, Kyung-Hoon;Roh, Hwasung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.2
    • /
    • pp.67-74
    • /
    • 2019
  • In this paper the response factor is investigated for middle and small size-RC slab aged bridges. The response factor consists of static and dynamic response factors and is a main parameter in the frequency based-bridge load carrying capacity prediction model. Static and dynamic response factors are determined based on the frequency variation and the impact factor variation respectively between current and previous (or design) states of bridges. Here, the impact factor variation is figured out using the impact factor response spectrum which provides the impact factor according to the natural frequency of bridges. In this study, four actual RC slab bridges aged over 30 years after construction are considered and their span length is 12m. The dynamic loading test in field using a dump truck and eigenvalue analysis with FE models are conducted to identify the current and previous (or design) state-natural frequencies of the bridges, respectively. For more realistic considerations in the moving loading situation, the impact factor response spectrum is developed based on tri-axle moving loads representing the dump truck load distribution and various supporting conditions such as simply supported and both ends fixed conditions. From the results, the response factor is widely ranged from 0.21to 0.91, showing that the static response factor contributes significantly on the results while the dynamic response factor has a small effect on the result. Compared to the results obtained from the impact factor response spectrum based on the single axle-simply supported condition, the maximum percentage difference of the response factors is below 3.2% only.