• Title/Summary/Keyword: 야간 기온

Search Result 98, Processing Time 0.036 seconds

A Numerical Study on the Effects of Urban Forest and Street Tree on Air Flow and Temperature (도시숲과 가로수가 대기 흐름과 기온에 미치는 영향에 관한 수치 연구)

  • Kang, Geon;Choi, Wonsik;Kim, Jae-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1395-1406
    • /
    • 2022
  • This study investigated the effects of the urban forest and street trees on flow and temperature distribution in the Daegu National Debt Redemption Movement Memorial Park. For this, we implemented tree-drag and tree-cooling parameterization schemes in a computational fluid dynamics (CFD) model and validated the simulated wind speeds, wind directions, and air temperatures against the measured ones. We used the wind speeds, wind directions, air temperatures predicted by the local data assimilation and prediction system (LDAPS) as the inflow boundary conditions. To investigate the flow and thermal characteristics in the presence of trees in the target area, we conducted numerical experiments in the absence and presence of trees. In the absence of trees, strong winds and monotonous flows were formed inside the park, because there were no obstacles inducing friction. The temperature was inversely proportional to the wind speed. In the presence of trees, the wind speeds(temperatures) were reduced by more than 40 (5)% inside the park with a high planting density due to the tree drag (cooling) effect, and those also affected the wind speeds and temperatures outside the park. Even near the roadside, the wind speeds and temperatures were generally reduced by the trees, but the wind speeds and air temperatures increased partly due to the change in the flow pattern caused by tree drag.

A Study on Predicting North Korea's Electricity Generation Using Satellite Nighttime Light Data (위성 야간광 자료를 이용한 북한의 발전량 예측 연구)

  • Bong Chan Kim;Seulki Lee;Chang-Wook Lee
    • Korean Journal of Remote Sensing
    • /
    • v.40 no.1
    • /
    • pp.81-91
    • /
    • 2024
  • Electrical energy is a key source of energy for modern civilization, and changes in electricity generation and consumption are closely related to industry and life in general. In this study, we identified the correlation between electricity generation and nighttime light values in South Korea and used it to predict monthly electricity generation trends in North Korea. The results of the study showed a low Pearson correlation coefficient of 0.34 between nighttime light and electricity generation in Seoul, but a high Pearson correlation coefficient of 0.79 between weighting for Seoul case nighttime light values and electricity generation using monthly average temperature. Using nighttime light values weighting for Seoul case by the average monthly temperature in Pyongyang to predict the monthly power generation trend in North Korea, we found that the month-on-month power generation increase in December 2022 was about 60% higher than the month-on-month power generation increase in December 2020 and 2021. The results of this study are expected to help predict monthly electricity generation trends in regions where monthly electricity generation data does not exist, making it difficult to identify timely industry trends.

Comparison of Thermal Effects of Different School Ground Surface Materials - A Case of Yooljeon Elementary School- (학교운동장 피복물질 간의 온열효과 비교 - 율전초등학교를 대상으로 -)

  • LIM, Joong-Bin;YU, Jinhang;LEE, Ju-Yeol;LEE, Kyoo-Seock
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.18 no.2
    • /
    • pp.28-44
    • /
    • 2015
  • Granite soil has been used traditionally as a school playground surface. Natural turf has also been used in some schools. Recently artificial turf has come into common use instead of granite soil or natural turf. Artificial turf playgrounds are used at 174 schools in Seoul, Korea. More than 3,500 artificial turf fields are installed in the United States. Because of the increase of artificial turf usage, there are many studies about the estimation of artificial turf effects to environment. Compared with artificial turf material effects such as characterization of substances released from material, and recognition of volatility of heavy metal into the surrounding environment - air or the percolating rainwater -, less studies for thermal effects of artificial turf playground have been done. Especially, the corresponding studies in Korea are few. Thus, the purpose of this research is to compare the thermal effects of artificial turf on school playground between natural turf and granite soil. In this study, air temperature and Predicted Mean Vote (PMV) were compared in three scenarios by Computational Fluid Dynamics (CFD) model. Additionally, the results were validated through a field measurement. Air temperature decreasing effects by natural turf are greater than those by artificial turf and granite soil at 14:30 on 20th, July 2011. It shows the same decreasing effects at 23:30. However, the difference is less than that of daytime. PMV differences between natural turf and the other two surface covers are large at daytime while those are much less at nighttime. Consequently, air temperature and PMV of artificial turf are the highest among three school playground surface pavements.

The Variation of Air Temperature and Humidity of Rock Bed Storage for Solar-Heated Greenhouse in Summer Season (여름철 자갈축열 태양열 온실의 축열층 온.습도 변화)

  • 이석건;이종원;이현우;김길동
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2000.10b
    • /
    • pp.128-131
    • /
    • 2000
  • 자갈축열 태양열 온실에 있어 여름철 냉방에너지의 효과적인 절감 방안을 모색하고자 축열 및 배기시스템의 작동방식을 다르게 하여 주ㆍ야간 축열과 방열시 자갈축열층의 온습도환경을 분석한 결과를 요약하면 다음과 같다. 1. 주간에 외기온이 28.5$^{\circ}C$-35.3$^{\circ}C$범위에서 변화할 때 자갈축열층내로 유입되는 공기의 온도는 30.5$^{\circ}C$-36.2$^{\circ}C$, 자갈축열층에서 온실내부로 유출되는 공기의 온도는 28.2$^{\circ}C$-30.1$^{\circ}C$, 축열층 내부온도는 27.4$^{\circ}C$-35.9$^{\circ}C$ 범위였다. 또한, 10시간 축열시 자갈축열층 내부온도는 측점에 따라 1.7$^{\circ}C$-7.$0^{\circ}C$의 온도상승이 있었으며 유입구에서 멀어질수록 축열층 온도는 낮게 나타났으며 온도상승 속도 또한 감소하는 경향으로 나타났다. 그리고, 야간에 축열시스템을 작동하지 않고 배기팬만을 작동하였을 경우, 외기온이 27.4$^{\circ}C$-34.4$^{\circ}C$범위일 때 자갈축열층 내부온도는 29.7$^{\circ}C$-34.9$^{\circ}C$(평균 31.4$^{\circ}C$)범위였으며 온실외부에 설치되어 있는 배기구와 배기팬의 영향으로 축열층 내부온도는 시간이 경과함에 따라 감소하는 경향으로 나타났으며 측점에 따라 2.2$^{\circ}C$-5.1$^{\circ}C$(평균 2.8$^{\circ}C$)의 온도하강 효과가 있는 것으로 나타났다. 2. 여름철 주간에 10시간 축열시 자갈축열층 내부습도는 측점에 따라 8.1%-26.3%의 감소현상이 있었다. 또한, 유입구에서 멀어질수록 축열층 습도는 높게 나타났으며 습도하강속도 또한 감소하는 경향으로 나타나 유입구에서 멀어질수록 외부습도의 영향을 적게 받는 것으로 분석되었다. 하지만, 야간에는 배기시스템의 영향으로 자갈축열층의 습도는 외기의 영향을 많이 받는 것으로 나타났다.

  • PDF

Spatial Distribution of Temperature in and around Urban Parks- A Case Study of around Changkyeong Palace, Changdeok Palace and Jongmyo in Seoul- (도시 녹지와 그 주변 기온의 공간적 분포- 서울시 종로구 창경궁, 창덕궁, 종묘 주변을 사례로-)

  • 권영아;이현영
    • Journal of the Korean Geographical Society
    • /
    • v.36 no.2
    • /
    • pp.126-140
    • /
    • 2001
  • The influence of small urban parks(green ratio is 100%) on the temperature pattern over the urban and its surrounding area was examined by analyzing the case of in and around Changkyeong palace, Changdeok plalace and Jongmyo, Jongro-gu, Seoul. The pattern of temperature over urban parks and their surrounding built-up area was analyzed from September to November 2000, measuring maximum and minimum temperatures with fixed sensors(maximum and minimum thermometer)and real-time temperature depends largely on both the land-use type and the distance from the park border. In the case of maximum temperature, the lowest value appeared on the green area within parks and the highest value on the built-up area far from the green area. The maximum temperature difference between parks and built-up areas was up to $7.3^{\circ}C$. In the built-up area, the maximum temperature of commercial areas was higher than residential areas. In the night time, not only land-use type but also topography is important for the spatial distributlon of temperature because of the cold airflow from adjacet hills. The horizontal temperature profile by mobile measurement is also related to land-use type and to the distance from the park borders. There is a magnitude of $1^{\circ}C$ temperture difference over a distance of 200m and $3~4^{\circ}C$ over a distance of 400m from the park borders.

  • PDF

Effect of Heat Conservation for the Double Covered Vinyl House (이중(二重)비닐하우스이 보온효과(保溫效果))

  • Lee, Suk Gun;Baek, Cheol Man
    • Current Research on Agriculture and Life Sciences
    • /
    • v.2
    • /
    • pp.91-97
    • /
    • 1984
  • This study was performed to suggest the basic information for the development of covering method for increasing the effect of heat conservation in the unheated vinyl houses. Double and single covered vinyl houses were constructed and the inside temperature variation of the double covered vinyl house was compared to the single covered vinyl house. The results obtained for the vinyl houses were summarized as follows ; 1. With the outside temperature of $-1.0^{\circ}C{\sim}7.5^{\circ}C$ and the solar radiation of maximum $1.02MJ/m^2$, the double covered vinyl house was shown $1.2^{\circ}C$ higher than the single covered vinyl house in the daily mean of inside temperature. 2. The inside temperature of the double covered vinyl house was $2.3^{\circ}C$ higher in the daytime and $1.2^{\circ}C$ higher in the nighttime than that of the single covered vinyl house. 3. The inside temperature of the vinyl house were expressed by the formular (1)-(6) with the outside temperature and by the formular (7)-(10) with the solar radiation. 4. In the effect of heat conservation based on the outside temperature, the double covered vinyl house was 1.2 times in the daytime and 1.76 times in the nighttime in comparison with the single covered vinyl house.

  • PDF

Influences of DIF on Growth and Development of Plug Seedlings of Lycopersicon esculentum before and after Transplanting (주야간 온도차(DIF)에 따른 토마토 플러그묘의 생장과 정직후 생육)

  • 임기병;손기철;정재동
    • Journal of Bio-Environment Control
    • /
    • v.6 no.1
    • /
    • pp.34-42
    • /
    • 1997
  • Effects of DIF on stem elongation in plug seedlings of mini tomato ‘Mini Carol’ and on the growth and flowering after transplanting were investigated. Stem elongation of seedlings was mainly influenced by day temperature rather than night temperature. When the effect of +DIF was compared to that of -DIF under the same average daily temperature(ADT), day temperature had greater impact on internode elongation than night temperature. On the other hand, leaf unfolding rate increased and compactness decreased as ADT in creased. Differences in internode length affected by DIF during seedlings stage DIF progressively diminished during growth period after transplanting. Node position at which first flower was initiated was lowered as ADT decreased. It was concluded that DIF treatment was an applicable tool for control of stem elongation, particularly to reduce stem length without a noticeably adverse effect on the growth and development of plant after transplanting.

  • PDF

Structure and Experimental Results of Automatic Insulation Greenhouse (자동단열온실의 구조 및 운전특성)

  • 이종원;이석건;이현우
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1994.05a
    • /
    • pp.88-91
    • /
    • 1994
  • 최근 국내에서도 시설원예가 급격하게 보급되고 있는 실정이다. 하지만, 시설원예가 에너지 소비형의 농경방식이라 지적되고 있는바 에너지절약형 온실의 개발이 필요할 것으로 판단되어, 본 실험실에서는 본 연구와 관련하여 비닐하우스의 벽체를 이중으로 하여 이중벽사이에 단열입자를 송풍기의 케이싱내로 직접 통하게하는 직송방식으로 충전ㆍ회수하는 실험을 실시한 바가 있으며, 그 결과 외기온의 평균이 -4.9$^{\circ}C$인 겨울철 야간에 입자를 충전한 이중비닐 하우스의 내부온도는 평균 9.8$^{\circ}C$로 단열성이 우수함을 알 수 있었다.(중략)

  • PDF

The Quantitative Analysis of Cooling Effect by Urban Forests in Summer (여름철 도시 인근 산림에 의한 냉각효과의 정량화에 대한 연구)

  • Lee, Hojin;Cho, Seongsik;Kang, Minseok;Kim, Joon;Lee, Hoontaek;Lee, Minsu;Jeon, Jihyeon;Yi, Chaeyeon;Janicke, Britta;Cho, Changbeom;Kim, Kyu Rang;Kim, Baekjo;Kim, Hyunseok
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.20 no.1
    • /
    • pp.73-87
    • /
    • 2018
  • A variety of micro meteorological variables such as air temperature, wind, solar radiation and latent heat at Gwangneung forests (conifer and broadleaved forests) and AWS (Automated Weather Station) of Pocheon urban area were used to quantify the air temperature reduction effect of forests, which is considered to be an eco-friendly solution for reducing the urban heat island intensity during summer. In June, July and August of 2016 and 2017, the average maximum air temperature differences between above and below canopy of forests, and between the forests and urban areas were $-1.9^{\circ}C$ and $-3.4^{\circ}C$ respectively, and they occurred at 17:00. However, there was no difference between conifer and broadleaved forests. The effect of air temperature reduction by the forests was positively correlated with accumulated evapotranspiration and solar radiation from 14:00 to 17:00 and showed a negative correlation with wind speed. We have developed a model to quantify the effect of air temperature reduction by forests using these variables. The nighttime air temperature reduction effect by forests was due to the generation of cold air from radiative cooling and the air temperature inversion phenomenon that occurs when the generated cold air moves down the side of mountain. The model was evaluated in Seoul by using 28 AWSs. The evaluation shows that the air temperature of each district in Seoul was negatively correlated with the area and size of the surrounding tall vegetation that drives vegetation evapotranspiration during the day. During the night, however, the size of the surrounding tall vegetation and the elevations of nearby mountains were the main influencing factors on the air temperature. Our research emphasizes the importance of the establishment and management of urban forests and the composition of wind roads from mountains for urban air temperature reduction.

Development of a pipe burst detection model using large consumer's smart water meter and pressure data (대수용가 스마트미터와 수압 데이터를 이용한 소블록 내 관 파손사고 감지모델 개발)

  • Kyoung Pil Kim;Wan Sik Yu;Shin Uk Kang;Doo Yong Choi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.521-521
    • /
    • 2023
  • 지방상수도의 관 파손사고 감지 및 누수관리 방법에는 블록시스템 구축을 통한 소블록별 야간최소유량 감시방법이 가장 대표적이다. 야간최소유량은 새벽 2시와 4시 사이의 인구 활동 비율이 가장 낮은 새벽 시간대에 소블록에 공급된 유량을 의미하며, 대부분 유량 성분은 누수량일 것이라는 가정에서 출발한다. 그러나 아파트 중심의 주거 형태를 보이는 도심지의 경우, 새벽 시간대에도 다량의 물수요가 비정기적으로 발생하고 있어 관망의 이상 여부를 감시하기 위한 관리기준으로서 야간최소유량을 이용하기에는 높은 일간 변동성에 따른 한계가 있다고 할 수 있다. 즉, 야간최소유량은 관 파손사고 발생의 감시보다는 관로 연결 또는 급수전 분기 부위에서 발생하는 미량의 누수가 수개월에 걸쳐 누적되는 장기추세를 분석하여 누수탐사반의 투입 시점을 결정하기 위한 근거를 제시하기 위한 목적으로 사용되며, 아직까지 관 파손사고의 발생은 자체적인 감지보다는 민원에 의해 인지되는 경우가 많다. 최근, 스마트관망 구축사업(SWM) 등을 통해 관 파손 및 누수 감지를 위한 청음식 누수감지센서가 소블록 내 도입되고 있으나, 초기 시설투자에 큰 비용이 수반되며 주변 소음과 배터리 전원방식의 한계로 인하여 새벽 시간대에만 분석이 제한적으로 적용되는 경우가 많아 이 역시도 상시적인 관 파손사고의 감시기술이라 보기는 어렵다. 본 연구에서는 소블록 유입점에서의 유량·압력과 소블록 내에 설치된 대수용가 스마트미터, 그리고 사고감지를 위한 수압계 사이의 평상시 수리적 균형을 학습한 DNN(Deep Neural Network) 모델을 이용하여 관 파손사고를 실시간 감지하는 모델 개발연구를 수행하였다. 모델은 관 파손사고 감지를 위한 수압계의 최적 위치와 대수를 결정하기 위한 모듈과 관 파손사고 감지모듈로 구성되며, 1개 소블록 Test-Bed를 구축하여 모델을 생성하고 PDD 관망해석 모델을 통해 생성된 가상의 사고에 대한 감지 여부로서 개발 모델의 감지성능을 평가하였다.

  • PDF