• Title/Summary/Keyword: 액체 질소(liquid nitrogen)

Search Result 245, Processing Time 0.027 seconds

Cryogenic Performance Test of LOX Turbopump in Liquid Nitrogen (액체질소를 이용한 산화제펌프의 극저온 성능시험)

  • Kim, Jin-Sun;Hong, Soon-Sam;Kim, Dae-Jin;Choi, Chang-Ho;Kim, Jin-Han
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.4
    • /
    • pp.391-397
    • /
    • 2010
  • Performance tests of a liquid-oxygen pump were carried out using liquid nitrogen (LN2) as a working fluid in a cryogenic turbopump test facility in Korea Aerospace Research Institute (KARI). The tests were performed at 30-55% of the design rotational speed, and the results were compared with those from a water test. The experimental results confirmed the similarity of the hydraulic performance, which allows the prediction of the pump performance at a design rotational speed of 20,000 rpm. The overall cavitation performance of the pump in the cryogenic environment was better than that in the water environment for all ranges of flow rates and rotational speeds. Critical cavitation number at the design flow rate was determined as 0.012 from the cryogenic test, and as 0.024 from the water test. The improved cavitation performance is due to the thermodynamic effect in cryogenic fluids.

Temperature Distribution of Liquid Nitrogen Jet at Sub- and Supercritical States (아임계 및 초임계에서 액체 질소 분류의 온도 분포)

  • Lee, Hyunchang;Kim, Haisol;Cho, Seongho;Sung, Hong-Gye;Yoon, Youngbin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.1
    • /
    • pp.1-6
    • /
    • 2018
  • Temperatures of cryogenic nitrogen jet inside an injector and at three different downstream positions (0.9, 10.6, and 28.1d) were measured with thermocouples in sub- and supercritical states. The jet temperature decreased while cooling the supply line and injector. The jet experienced from flash boiling, boiling and then no boiling according to decreasing temperature. As an analogy to flash-boiling at the subcritical state, pseudo-flash boiling has been assumed considering the existence of pseudo-boiling at the supercritical state. By showing an area where the temperature did not increase downstream, the plausibility of pseudo-flash boiling is proposed.

적외선 검출기를 위한 액체 질소 온도 동작 밴드갭 기준회로의 설계

  • Kim, Youn-Kyu
    • Aerospace Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.251-256
    • /
    • 2004
  • A stable reference voltage generator is necessary to the infrared image signal readout circuit(ROIC) to improve noise characteristics in comparison with signals originated from infrared devices, that is, to gain good images. In this study, bandgap reference circuit operating at cryogenic temperature of 77K for Infrared image ROIC(readout integrated circuit) was propose. Most of bandgap reference circuits which are presented so far operate at room temperature, and they are not suitable for infrared image ROIC operating at liquid nitrogen temperature, 77K. To design bandgap reference circuit operating at cryogenic temperature, the parameter characteristics of used devices as temperature change are seen, and then bandgap reference circuit is proposed with considering such characteristics. It demonstrates practical use possibility through taking measurements and estimations.

  • PDF

Cryogenic Jet Injection Test Using Liquid Nitrogen (액체 질소를 이용한 극저온 단일 제트 분사 시험)

  • Cho, Seong-Ho;Khil, Tae-Ock;Park, Gu-Jeong;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.597-600
    • /
    • 2010
  • Cold flow injection test was conducted to investigate the characteristics of cryogenic liquid nitrogen jet at sub to supercritical condition. Single jet injector element was installed in high pressure chamber to investigate the effect of ambient pressure around the jet, injector geometry and flow conditions. Experimental results showed obvious differences between jet characteristics under subcritical and supercritical condition. Effect of injector inlet shape also was investigated.

  • PDF

Backlight image of liquid nitrogen jet at supercritical state (초임계에서 액체 질소 분류의 역광 사진)

  • Lee, Hyunchang;Yoon, Youngbin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.709-712
    • /
    • 2017
  • Liquid nitrogen jet has been imaged by using backlight method. In addition to the images, simultaneously measured temperature by thermocouples has been used to investigate the role of 'Pseudo-flash-boiling' in breakup of the supercritical jet. The backlight image can provide qualitative appearance of the jet, but not the density profile for the high density of injected fluid.

  • PDF

Transient State Theory of Significant Liquid Structure Applied to Nitrogen Oxides (액체 구조의 천이상태이론의 질소산화물들에 대한 적용)

  • Kim, Sang-Hyung;Pak, Hyung-Suk;Kim, Kak-Choong;Chang, Sei-Hun
    • Journal of the Korean Chemical Society
    • /
    • v.11 no.3
    • /
    • pp.105-110
    • /
    • 1967
  • The transient state theory of significant liquid structure is applied to nitrous oxide and nitrogen tetroxide. The partition functions for the two liquids are derived according to the transient state theory. The various thermodynamic properties; such as, molar volumes, vapor pressures, entropies of vaporization, and critical point properties agree well with the experimental values.

  • PDF

Dynamic Electrical Breakdown Characteristics of Cryogenic Liquid (극저온 액체의 동적 절연파괴 특성)

  • 김상현;김현희;김영석;정종만;정순용
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.4
    • /
    • pp.321-326
    • /
    • 1998
  • Electrical breakdown characteristics of liquid nitrogen($LN_2$) taking into consideration for application of high $T_c$ superconductor is very important. Also $LN_2$ will be used as both coolant and insulator in superconducting generator. In this paper, we investigated ac breakdown characteristics of cryogenic nitrogen gas above a $LN_2$ for rod-to plane electrode configuration. As result the breakdown mechanism of $LN_2$is dependence on bubble effect. And breakdown voltage is a ratio on bubble s size but electrodes arrangement is to make no difference. The breakdown voltage decreases slightly with increasing flow velocity, it again decreases abruptly with increasing flow velocity. These results were interpreted as the within pressure of rod electrode and Maxwell force.

  • PDF

Evaporation Heat Transfer Characteristics of Liquid Nitrogen in Horizontal Plain Tubes with Wire Coil Inserts (평활관 및 열전달촉진관에서 액체질소의 관내 증발열전달 특성에 대한 연구)

  • Hwang, Jee-Sang;Chung, Jin-Taek;Yun, Rin;Kim, Yong-Chan;Moon, Young-June;Kim, Dong-Hyuk
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1359-1364
    • /
    • 2004
  • An experiment was performed to study the evaporation heat transfer and the pressure drop characteristics of liquid nitrogen in a horizontal stainless steel tube with wire coil inserts. The inner diameter of test tube is 4.3mm and the length is 1.5m. Four wire coils having different pitch and thickness were inserted into the plain test tube. The wire coil length is 1.5m and the diameter is 3.65mm with thickness of 0.5mm and 0.9mm. Experiments were conducted at saturation temperature of $-191^{\circ}C$ mass flux from 200 to 370 $kg/m^{2}s$ and heat flux of 62 $kW/m^{2}$. Direct heating method was used to apply heat to the test section. Boiling heat transfer coefficients of both the plain and the enhanced tubes were calculated. Pressure drops between inlet and outlet side of test section were also measured, and they are used to estimate EPR(Enhancement Performance Ratio).

  • PDF

A study on the characteristics of surfase flashover in the liquid nitrogen for crylogenic cable (극저온 전력케이블용 냉매(액체질소)에 대한 연면방전특성)

  • 신동화;박광서;주재현;최병주;김기채;박원주;이광식;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.63-66
    • /
    • 1997
  • 본 논문은 초전도 및 극저온 케이블의 냉매와 전기절연으로 사용되고 있는 액체질소의 연면방전특성에 관하여 연구하였다. 기포효과를 고려하여 대기압하에서의 정극성 및 부극성 직류고전압을 사용하였고, 연면방전시 방사되는 방사전자파의 스펙트럼 분포 특성을 관측하였다.

  • PDF

Studies of application of artificial ground freezing for a subsea tunnel under high water pressure - focused on case histories - (고수압 해저터널 건설을 위한 동결공법 적용성에 관한 연구 - 사례를 중심으로 -)

  • Son, Young-Jin;Lee, Kyu-Won;Ko, Tae Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.5
    • /
    • pp.431-443
    • /
    • 2014
  • In this paper case studies of artificial ground freezing, which have not been applied in Korea, have been investigated for the water cut-off in a subsea tunnel under high water pressure and the most commonly used cooling mediums of brine and liquid nitrogen are examined. Since sea water with pressure has the lower freezing point than pure water, the lower temperature cooling medium is required in the application of subsea tunnel. Also, the cooling medium must have refrigeration safety and is able to reduce executing time. Brine freezing system can reuse cooling medium and is safer than liquid nitrogen freezing. But it takes more time to freeze ground and needs complex circulation plants. On the other hand, liquid nitrogen freezing system can't recycle cooling medium and may cause breathing problems or asphyxiation through oxygen deficiency. But, freezing with liquid nitrogen is fast and requires simple refrigeration equipment. Principal elements of design for ground freezing in subsea tunnel have been extracted and these elements are needed further research.