• Title/Summary/Keyword: 액체 질소(liquid nitrogen)

Search Result 245, Processing Time 0.027 seconds

A study on the characteristics of arc discharge and radiated electromagnetic wave in liquid nitrogen (액체질소중에 있어서 아크방전 및 방사 전자파의 특성에 관한 연구)

  • Shin, Dong-Hwa;Park, Kwang-Seo;Ju, Jae-Hyun;Choi, Byung-Ju;Kim, Ki-Chai;Lee, Kwang-Sik;Lee, Dong-In
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1669-1671
    • /
    • 1997
  • Liquid nitrogen has many adventages. It is cheaper than other cooling medium. It is easy to obtain high purity. It's utilized with easy. In future, liquid nitrogen is able to be accepted cooling medium for the superconducting and cryogenic applicated equipments. Cryogenic liquid may be atmospheric pressure state because thermoinsulation is ineffective, airtight decreasing by long time using and bubble occured by flowing current. If it is to be atmospheric pressure state, the electrical insulation strength is dropped and processed partial discharge, finally breakdown. Processing of breakdown has anticipated by measuring radiated-electromagnetic wave which is happened in time of breakdown. There is a measurement of radiated electromagnetic wave as a method that proceeding breakdown is anticipated. In this paper, radiated electromagnetic wave was measured in arc discharge by above conditions as a basic experiment.

  • PDF

Development of analysis method for high purity nitrogen using GC-FID/Methanizer (GC-FID/Methanizer를 이용한 고순도 질소의 순도분석법 개발)

  • Jei, You;Jin Bok, Lee;Jin Seog, Kim;Woonjung, Kim;Kiryong, Hong
    • Analytical Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.249-255
    • /
    • 2022
  • In this study, a new method for the analysis of high-purity nitrogen was developed. A gas chromatography-flame ionization detector (GC-FID) was used for purity analysis. Certified reference materials (CRMs) at a level of 3 µmol/mol of carbon monoxide (CO), carbon dioxide (CO2), and methane (CH4), which may exist in high-purity nitrogen, were prepared using the gravimetric method, and these CRMs were used for purity analysis. In this new method, ultra-high-purity and high-purity nitrogen were used as carrier gases. The impurities in high-purity nitrogen were quantitatively analyzed by comparing the differences in the area values of the GC chromatograms of the prepared CRMs. We purchased liquid nitrogen and three bottles of nitrogen gas, which were produced by three different manufacturers, using high-purity nitrogen. Furthermore, to validate the developed purity analysis method, the fraction of impurities in high-purity nitrogen was compared with the results of the typical purity analysis method. The comparison results were consistent within the expanded uncertainties (k = 2).

Experiment of Natural Circulation Loop Using a Cryocooler (극저온냉동기를 이용한 자연순환 루프의 실험)

  • Kim, M.J.;Chang, H.M.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2194-2199
    • /
    • 2007
  • An experimental study is performed to investigate the thermal and flow characteristics of subcooled liquid nitrogen in a natural circulation loop. Experimental apparatus is designed and constructed such that a closed loop is cooled at the top by a cryocooler and heated nearly at the bottom by cartridge heaters. Steady state is obtained by controlling the heating power to the cartridge heaters and a thin-film heater to reduce the cooling power of the cryocooler. Temperature is measured at several locations of the loop and the mass flow rate through the loop is estimated from the energy balance in terms of the measured temperatures. Experiment is repeated for various values of the vertical height between the cooling and heating parts. The results show that the heat transfer capability of the loop has a maximum at a certain value of height. The optimal height to maximize the heat transfer is in a good agreement with analytical prediction to take into account the buoyancy and viscous forces in the loop.

  • PDF

The Characteristics of Tracking Phenomena and Surface Discharge Using Various Types of Electrode Arrangement in $LN_{2}$ at the Atmospheric Pressure (대기압하의 액체질소중 전극배치에 따른 고체유전체 표면의 연면방전 및 Tracking현상)

  • 박경태;신호영;박광서;최병주;이광식;이동인
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.114-118
    • /
    • 2002
  • This paper were investigated discharge characteristics in the Liquid Nitrogen($LN_{2}$) noticed as a cooling medium of high temperature superconductor, and the characteristics of surface discharge and tracking phenomena on the solid insulators of cryocable. In order to investigate the bubbles which have much influence on electric surface discharge in Liquid Nitrogen, knife type electrode and plane electrode was formed oppositely with mode A and B, C configuration. It is considered that these result are fundamental data for electric insulation design of superconductivity and cryogenic application machinery which will be studied and developed in the future.

  • PDF

Studies on Simplified Procedures for Freezing and Thawing of Bovine Embryos VI. Effects of freezing procedures in a liquid nitrogen container on the survival rate of mouse embryos (육우수정란 간역동결 및 융해방법에 관한 연구 제육보. 내동제에 Sucrose 첨가에 따른 액체질소에 미치는 영향)

  • 이중계;이규훈;강만종;김영훈;문성호;김승호
    • Korean Journal of Animal Reproduction
    • /
    • v.12 no.2
    • /
    • pp.77-83
    • /
    • 1988
  • This study was done with mouse embryo to assess effects of freezing media containing sucrose, freezing metods(1-F, 0.3$^{\circ}C$/min;2-F, 3-5$^{\circ}C$/min;3-F, 15$^{\circ}C$min;4-F, LN2 vapour) and cell freezers on the embryo survival determined using the FDA test. The results are summarized as follows. 1. The FDA score obtained with 1, 2, 3 and 4-F was 3.8, 3.6, 3.2 and 3.2, respectively. There was a significant difference(P<0.05) between 1-F, 3-F and 2-F, 4-F. 2. The score at the morular stage(3.8) higher(P<0.005) than the blastocyst stage of embryos(3.2). 3. No difference (P>0.05) was found between the score obtained with a automatic embryo freezer(4.0) and a liquid nitrogen container(3.7).

  • PDF

Analytical and Experimental studies on Dielectric Characteristics of High Voltage Superconducting Machines in Liquid Nitrogen (액체질소를 사용하는 초전도 고전압 전력기기의 절연 특성 연구)

  • Na, J.B.;Ko, T.K.;Kang, H.;Seok, B.Y.;Kim, T.J.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.1
    • /
    • pp.46-50
    • /
    • 2011
  • The electrical insulation design of high voltage superconducting fault current limiters (SFCLs) should be confirmed to be applied for the stabilization of the power grid. This paper describes numerical analysis and AC dielectric experiments for developing high voltage SFCLs. The electric field distributions between applied high voltage part and ground were calculated by finite element method (FEM) simulation tool and AC criterion of liquid nitrogen at 200 kPa was calculated from correlation between the field utilization factor and FEM simulation results. This paper deals with ceonceptual insulation design of a 154 kV class single-phase no-inductively wound solenoid type SFCL which was focused on gap distance between the cryostat and superconducting coils. Furthermore, the shield ring effect was confirmed to reduce maximum electric field at applied high voltage part.

A Relationship between Partial Discharge and Radiated Electromagnetic Waves in Liquid Nitrogen (대기압하의 액체질소중 부분방전과 방사전자파의 상호관계)

  • Park, Kwang-Seo;Shin, Ho-Young;Kim, Chung-Nying;Kim, Ki-Chai;Park, Won-Zoo;Lee, Kwang-Sik;Lee, Dong-In
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.956-958
    • /
    • 1998
  • In this study, a relationship between partial discharge and the radiated electromagnetic waves is investigated by measuring electromagnetic waves using a biconical antenna and a spectrum analyzer. The patterns of frequency spectrum of radiated electromagnetic waves measured at the atmospheric pressure in Liquid Nitrogen($LN_2$) during the partial discharges in nonuniform electric field depend on positive DC power. From these points of view. it is considered that these results obtained from this investigation may be used as fundamental data for diagnosis and prediction of insulation on the equipments of superconducting and cryogenic applications.

  • PDF

Breakdown and Surface Flashover Characteristics of FRP in $LN_2$ (액체질소 중 FRP의 절연파괴 및 연면방전 특성 연구)

  • 정종만;백승명;김상현
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.119-123
    • /
    • 2002
  • In this study, we discussed the characteristics of breakdown and surface flashover of FRP in L$N_2$ for applying it to spacer of a superconducting power equipment. Fiberglass reinforced plastic(FRP) has high breakdown puncture strength and has high mechanical strength. So the research of its dielectric properties have been conducted in liquid nitrogen($LN_2$). We measured breakdown voltage of FRP and distinguished four types of surface flashover along solid insulator with arrangement of electrodes and measured the surface flashover voltages of each types of electrode arrangement. The type of a electrode set at the back of the insulator showed the worst dielectric property. The property of surface flashover depending on pressure was tested.

Characteristics of Dielectric Breakdown in Liquid Nitrogen (액체질소의 절연파괴특성)

  • 추영배;류경우;류강식;김상현
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.12
    • /
    • pp.872-878
    • /
    • 1988
  • During the past few years, a great deal of attention has been directed to the application of superconductivity to the electrical systems such as superconducting power transmission lines, superconducting magnet energy storage and so on. Yet in order to develop the practical model of these electrical equiqments utilizing suprconductivety and other phenomena at cryogenic temperautre, it is necessary to know the dielectric behaviour of insulating materials at cryogenic temperature in view of reliability, safety and economy of these machines. Investigation of dielectric properties of cryogenic liquids is very important due to the dual role of those as the dielectric and cooling medium. In this study, we investigated results measured over several kinds of dielectric characteristics of liquid nitrogen taking into consideration for application of high Tc superconductor. Dependence of breakdown voltage of gap width, polarity and pressure is reported in this paper and time delay characteristics of breakdown is also the subject of this discussion.

  • PDF

Cryogenic Bearing and Seal Test Facility for a Turbopump (터보펌프용 극저을 베어링/실 성능시험설비)

  • Kwak, Hyun-D.;Jeon, Seong-Min;Kim, Jin-Han
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.341-347
    • /
    • 2005
  • To perform a cryogenic development test for Tribo-elements in a turbopump, a cryogenic bearing and seal test facility (BSTF) is designed and currently under construction in KARI. The working fluid is liquid nitrogen operating at a temperature $-197^{\circ}C$. The maximum operating pressure and volume flow rate of BSTF are 100 bar and 10 liters per second, respectively. The development tests of floating ring seals, inter-propellant seals (IPS) and cryogenic ball bearings in a turbopump will be performed using the BSTF. This paper briefly described design requirements and procedures of BSTF.

  • PDF