• Title/Summary/Keyword: 액위

Search Result 24, Processing Time 0.026 seconds

Development of an Assembly-type Liquid Level Control Experimental Equipment and a Hands-on Activity Task for Vocational High School 'Chemical Process Maintenance Operation' Subject (특성화고 '화학공정유지운영' 교과를 위한 조립형 액위제어 실험장치 및 체험활동과제 개발)

  • Jung, Eun-Suk;Lee, Kyung Taek
    • 대한공업교육학회지
    • /
    • v.45 no.2
    • /
    • pp.1-20
    • /
    • 2020
  • The purpose of this study is to develop an assembly-type liquid level control experimental equipment and a hands-on activity task that can be applied to the class so that students studying the chemical industry can easily understand the liquid level control. For this purpose, the content elements related to liquid level control in the chemical industry practice course of the 2015 revised curriculum was analyzed, a hands-on activity task with an assembly-type liquid level control experimental equipment was and developed. And then, expert verification was also performed and the hands-on activity task was applied to 19 students of S meister high school. The results obtained through this are as follows. First, the existing completion-type liquid level control experimental equipment was explored, and based on this, a new assembly-type liquid level control experimental equipment that can be assembled by students and used for practices was designed and manufactured. Second. by analyzing the contents of the NCS-based 'Chemical Process Maintenance Operation' practical course of the 2015 revised curriculum, learning contents related to level control were extracted. Among the contents related to the level control, the practice with understanding the process flow chart, manufacturing the level control experimental equipment, measuring the flow rate, and checking the level control phenomenon were conducted with the assembly-type liquid level control experimental equipment to systematically learn the level control.

Effect of heat treatment and sintered microstructure on electrical properties of Mn-Co-Ni oxide NTC thermistor for fuel level sensor (연료액위센서용 Mn-Co-Ni 산화물계 서미스터의 전기적 특성에 미치는 열처리 및 소결미세구조에 관한 연구)

  • 나은상;백운규;최성철
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.13 no.2
    • /
    • pp.88-92
    • /
    • 2003
  • The correlationship between heat treatment condition and electrical properties of the Mn-Co-Ni oxide NTC thermistor for fuel level sensor was investigated by the X-ray diffractometry, density measurement, and electrical properties measurement such as resistivity, B constant, and thermal dissipation constant. It was shown that the heat treatment of NTC thermistor was responsible for sinterability of Mn-Co-Ni oxide. The highest density of 5.10 g/㎤ was obtained at $1250^{\circ}C$, 2 hours, at which the densification was almost completed. This is also manifested from the microstructural observation. It is found that the electrical resistivity and B constant are increased at the elevated sintering temperatures. The NTC specimens prepared in this study showed the conventional decrease of resistance with the measured temperature and the linear behavior of output voltage with fuel levels. Therefore, the electrical properties of thermistor were closely correlated with sintering condition. and the Mn-Co-Ni oxide thermistor prepared in this study has a great possibility enough to apply for an automobile fuel level sensor.

Liquid Level System Realizing Van de Vusse Reactor Dynamics and its Control Experiments (Van de Vusse 반응기 동특성을 구현하는 액위시스템 및 제어 실험)

  • Lee, Jietae
    • Korean Chemical Engineering Research
    • /
    • v.58 no.2
    • /
    • pp.184-189
    • /
    • 2020
  • Van de Vusse reactors show the maximum points in input-output steady state maps and dramatic changes in their dynamic characteristics around those maximum points. According to their operating regions, there appear sign changes in steady state gains and nonlinear characteristics such as non-minimum phase dynamics which cause difficulties in applying controllers. Many nonlinear controllers that are available and newly designed are applied to these Van de Vusse reactor processes and their performances are tested. Reactor examples with real reactions have been reported. However, due to difficulties in constructing and operating chemical reactor systems, they are not adequate to be used for real applications of control experiments and hence most of results are based on simulations studies. Here, we propose a liquid level system that realizes most of the steady state and dynamic characteristics of Van de Vusse reactor, and two nonlinear control methods that can be used as base methods to compare nonlinear controllers newly designed. Liquid level experimental system and two nonlinear control methods are very simple and can be used to test performances of nonlinear controllers in practice.

Liquid level control in a spherical tank by microcomputer (마이크로 컴퓨터를 이용한 구형 탱크의 액위 제어)

  • Kang, Won-Young;Oh, Min;Lee, Tae-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.459-462
    • /
    • 1986
  • The liquid level in a spherical tank was controlled with a micro-computer and the dynamic behavior of this non-linear system due to the variation of set point was studied. The adaptive control theory was used and the real values of controlled variables were compared with the theoretical values from a mathematical model.

  • PDF

Adaptive predictive level control of waste heat steam boiler based on bilinear model (쌍일차 모델을 이용한 폐열 스팀 보일러의 액위 적응 예측 제어)

  • Oh, Sea-Cheon;Yeo, Yeong-Koo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.2 no.4
    • /
    • pp.344-350
    • /
    • 1996
  • An adaptive predictive level control of waste heat steam boiler was studied by using mathematical models considering the inverse response. The simulation experiments of the model identification were performed by using linear and bilinear models. From the results of simulations it was found that the bilinear model represented the actual dynamic behavior of steam boiler very well. ARMA model was used in the model identification and the adaptive predictive controller. To verify the performance and effectiveness of the adaptive predictive controller used in this study the simulation results of the adaptive predictive level control for waste heat steam boiler based on bilinear model were compared to those of P, PI and PID controller. The results of simulations showed that the adaptive predictive controller provides the fast arrival to setpoint of liquid level.

  • PDF

Development of Thermal Type Fluid Level Transmitter for Water Level Measurement of Containment Building in Nuclear Power Plant (원자력 발전소 격납 건물의 수위 측정을 위한 열식 레벨 측정기 개발)

  • Yoon, Joon-Yong;Seong, Nak-Won;Lee, Chul-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.404-410
    • /
    • 2001
  • A new thermal type fluid level transmitter was designed and tested at the HITROL R&D institute. The relation of heat transfer and electric resistance was adopted as an operation principle. The length of a fabricated level transmitter was two meters and a water under normal temperature was used as a working fluid for the experiment Finally, the new product could have a high precision, acceptable accuracy and reasonable response time. Foreign-made level transmitter of this type is under in use for measuring water level of containment building in nuclear power plants so far. It is expected that new product will substitute it.

  • PDF

Effect of Helical Ribbon Impeller's Center Shaft & Lateral Supporting Struts on Mixing Performance (Helical Ribbon Impeller의 중심축과 스트럿이 혼합성능에 미치는 영향)

  • Koh, Seung-Tae
    • Korean Chemical Engineering Research
    • /
    • v.60 no.3
    • /
    • pp.468-471
    • /
    • 2022
  • The influence of the central axis and the strut supporting the helical ribbon was investigated in a helical ribbon impeller mixing tank through experiments and visualization. As a result, the strut, which is in the transverse direction, turned out to have a significant adverse effect on the mixing performance such as the occurrence of incomplete mixing region from the change of the liquid level. In contrast, the central axis, which in the longitudinal direction, did not show much adverse effects.

Investigation on the Heating Patterns Depending on the Packaging Materials During Microwave Cooking (포장 소재에 따른 전자레인지 가열 조리 패턴 조사)

  • Lee, Hwa Shin;Cho, Ah Reum;Moon, Sang Kwon;Yoon, Chan Suk;Lee, Keun Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.21 no.1
    • /
    • pp.27-34
    • /
    • 2015
  • Heating patterns depending on the packaging materials were examined in order to investigate the causes of thermal deformation of packages used for ready-to-eat foods for microwave heating due to the non-uniformity of microwaves. Physical properties including tensile strength, heat-resistance and elongation of four different CPP grades were compared. High retortable CPP had higher sealing strength and heat resistance compared to the conventional CPPs. All CPP samples tested were proved to have melting temperatures around $160^{\circ}C$. However, they were all thermally deformed by microwave heating due to a limited penetration of microwave and non-uniform heating within the spicy sauce of high viscosity contained high salt, especially on the above the filling line and sealing edge of pouches. When the laminated stand-up pouches composed of G-PET/PET/PET/CPP and G-PET/PET/NY/CPP were retorted and microwaved, significant deformations were noticed in both samples after retorting. Besides, pouches contained titanium dioxide showed more intense thermal deformation than the control. When the $10{\mu}m$ aluminium foil was affixed on the pouch, small thermal deformation was observed only in the bottom layer. More studies are required to prevent the thermal deformation of packaging materials used for RTE foods during microwave heating by developing the technologies to increase the thermal stability of CPP layer and the modification of packaging design to modify the microwave access into the package.

  • PDF

Three-Phase Eulerian Computational Fluid Dynamics (CFD) of Air-Water-Oil Separator with Coalescer (유적 합체기가 포함된 공기-물-기름 분리 공정에 대한 3상 Eulerian 전산유체역학)

  • Lim, Young-Il;Le, Thuy T.;Park, Chi-Kyun;Lee, Byung-Don;Kim, Byung-Gook;Lim, Dong-Ha
    • Korean Chemical Engineering Research
    • /
    • v.55 no.2
    • /
    • pp.201-213
    • /
    • 2017
  • Water is removed from crude oil containing water by using oil separator. This study aims to develop a three-dimensional (3D) Eulerian computational fluid dynamics (CFD) model to predict the separation efficiency of air-water-oil separator. In the incompressible, isothermal and unsteady-state CFD model, air is defined as continuous phase, and water and oil are given as dispersed phase. The momentum equation includes the drag force, lift force and resistance force of porous media. The standard k-${\varepsilon}$ model is used for turbulence flow. The exit pressures of water and oil play an important role in determining the liquid level of the oil separator. The exit pressures were identified to be 6.3 kPa and 5.1 kPa for water and oil, respectively, to keep a liquid level of 25 cm at a normal operating condition. The time evolution of volume fractions of air, water and oil was investigated. The settling velocities of water and oil along the longitudinal separator distance were analyzed, when the oil separator reached a steady-state. The oil separation efficiency obtained from the CFD model was 99.85%, which agreed well with experimental data. The relatively simple CFD model can be used for the modification of oil separator structure and finding optimal operating conditions.