• Title/Summary/Keyword: 압하

Search Result 7,227, Processing Time 0.033 seconds

Geologic, Fluid Inclusion, and Sulfur Isotopic Studies of Hydrothermal Deposit in the Tanggueng District, West Java, Indonesia (인도네시아 서부자바 땅긍(Tanggueng)지역 열수광상의 지질, 유체포유물 및 황동위원소 연구)

  • Jae-Ho Lee;In-Joon Kim
    • Economic and Environmental Geology
    • /
    • v.36 no.5
    • /
    • pp.321-328
    • /
    • 2003
  • The epithermal gold and base metal deposit of the Tanggeung district of West Java consists of four major veins(Celak, Cigodobras, Cilangkap and Pasirbedil) with NS to N10$^{\circ}$∼20$^{\circ}$E and N75$^{\circ}$W strikes. The veins occur within fractures cutting the crystal and lithic tuff of Jampang Formation(Oligo-Miocene) in and around the Mt. Subang of the western Java, Indonesia. The ore mineralization is characterized by the occurrence of pyrite, sphalerite, galena, chalcopyrite, and small amounts of bornite and Fe-oxides. Hydrothermal alteration, associated with the mineralization, was dominantly silicified and enveloped by the phyllitic(sericitic), argillic and propylitic alteration containing the disseminated pyrite. Gangue minerals consist of interstratified smectite-illite, chlorite, sericite, and minor kaolinite. The presence of vapor-rich fluid inclusions in quartz veins suggests that boiling occurred locally throughout ore deposition. Fluid inclusion studies suggest that the ore fluid evolved from initial high temperatures(〓34$0^{\circ}C$) to later lower temperatures(〓19$0^{\circ}C$). Salinities range from 0.0 to 8.3 wt percent NaCl equiv. The relatively high increase in salinity(up to 8.3 wt percent NaCl equiv) might be explained by a local boiling and by a participation of magmatic fluids, supported by the sulfur isotope results. Evidence of fluid boiling suggests that the pressure decreased from 200 bars to 120 bars. This corresponds to the depths of approximately 750 to 1,200 m in a hydrothermal system that changed from lithostatic to hydrostatic conditions. Using homogenization temperatures and paragenetic constraints, the calculated $\delta$$^{34}$ S values of $H_2S$ in ore fluid are -0.2 to 1.8 permil close to the 0 permil isotopic value of magmatic sulfur.

Study on the Consequence Effect Analysis & Process Hazard Review at Gas Release from Hydrogen Fluoride Storage Tank (최근 불산 저장탱크에서의 가스 누출시 공정위험 및 결과영향 분석)

  • Ko, JaeSun
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.449-461
    • /
    • 2013
  • As the hydrofluoric acid leak in Gumi-si, Gyeongsangbuk-do or hydrochloric acid leak in Ulsan, Gyeongsangnam-do demonstrated, chemical related accidents are mostly caused by large amounts of volatile toxic substances leaking due to the damages of storage tank or pipe lines of transporter. Safety assessment is the most important concern because such toxic material accidents cause human and material damages to the environment and atmosphere of the surrounding area. Therefore, in this study, a hydrofluoric acid leaked from a storage tank was selected as the study example to simulate the leaked substance diffusing into the atmosphere and result analysis was performed through the numerical Analysis and diffusion simulation of ALOHA(Areal Location of Hazardous Atmospheres). the results of a qualitative evaluation of HAZOP (Hazard Operability)was looked at to find that the flange leak, operation delay due to leakage of the valve and the hose, and toxic gas leak were danger factors. Possibility of fire from temperature, pressure and corrosion, nitrogen supply overpressure and toxic leak from internal corrosion of tank or pipe joints were also found to be high. ALOHA resulting effects were a little different depending on the input data of Dense Gas Model, however, the wind direction and speed, rather than atmospheric stability, played bigger role. Higher wind speed affected the diffusion of contaminant. In term of the diffusion concentration, both liquid and gas leaks resulted in almost the same $LC_{50}$ and ALOHA AEGL-3(Acute Exposure Guidline Level) values. Each scenarios showed almost identical results in ALOHA model. Therefore, a buffer distance of toxic gas can be determined by comparing the numerical analysis and the diffusion concentration to the IDLH(Immediately Dangerous to Life and Health). Such study will help perform the risk assessment of toxic leak more efficiently and be utilized in establishing community emergency response system properly.

Pressor Action of Intracerebroventricular Nicotine and Muscarine in the Rabbit (가토 측뇌실내 Nicotine 및 Muscarine의 혈압상승작용에 관하여)

  • Lee, Choong-Kyoung
    • The Korean Journal of Pharmacology
    • /
    • v.27 no.1
    • /
    • pp.21-31
    • /
    • 1991
  • When administered intracerebroventricularly (icv), cholinergic nicotinic agents, nicotine and DMPP, as well as cholinergic muscarinic agents, muscarine and bethanechol, produced pressor responses in urethane-anesthetized vagotomized rabbits. The response patterns to nicotine and to DMPP were similar, while the bethanechol response resembled the muscarine pattern. The pressor response to nicotine and DMPP was markedly inhibited by icv mecamylamine but not by icv pirenzepine, whereas the response to muscarine and bethanechol was inhibited by icv pirenzepine but not by icv mecamylamine, suggesting that both nicotinic and muscarinic receptors in the brain are involved in the action. Intravenous pretreatments of animals with regitine, reserpine, enalapril, saralasin, both regitine and enalapril, both regitine and saralasin, SK&F-100273 did not prevent the pressor response to nicotine and muscarine. Iv pretreatments with both regitine and SK&F-100273 inhibited the nicotine response without affecting the muscarine response, whereas pretreatments with three agents, regitine, enalapril and SK&F-100273, inhibited the muscarine response. The nicotine-induced elevated blood pressure as well as the muscarine-induced were lowered by regitine but not by enalapril or by SK&F-100273. Enalapril was without effect on the nicotine hypertension in rabbits treated with regitine or both regitine and SK&F-100273, whereas SK&F-100273 lowered the nicotine hypertension in regitine-treated animals. Enalapril did not enhance the lowering effect of SK&F-100273 in regitine-treated ones, nor did it cause a fall of the muscarine hypertension induced in regitine-treated rabbits, but it did lower the blood pressure in animals treated with both regitine and SK&F-100273. Likewise, SK&F-100273 did not cause a fall of the muscarine hypertension induced in regitine-treated rabbits, but it did lower the blood pressure in animals treated with both regitine and enalapril. These data suggest that the nicotine-induced hypertensive state is related to at least two systems in the periphery-sympathetic and vasopressin, whereas in the muscarine-induced hypertensive state three systems in the periphery are involved, i.e., the sympathetic, vasopressin and angiotensin system. The hypotensive effect of regitine on basal arterial blood pressure levels of rabbits was not influenced by pretreatment with either of enalapril or SK&F-100273, but significantly potentiated by treating with both enalapril and SK&F-100273, suggesting participation of the sympathetic and the renin-angiotensin system as well as the vasopressin system in maintenance of arterial blood pressure.

  • PDF

Preliminary Study for Development of Low Dose Radiation Shielding Material Using Liquid Silicon and Metalic Compound (액상 실리콘과 금속화합물을 융합한 저선량 방사선 차폐 소재 개발을 위한 사전연구)

  • Jang, Seo Goo;Han, Su Chul;Kang, Sung Jin;Lim, sung wook;Lee, Sung Soo
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.461-468
    • /
    • 2017
  • This study measured and compared the protective clothing using Pb used for shielding in a diagnostic X-ray energy range, and the shielding rates of X-ray fusion shielding materials using Si and $TiO_2$. For the experiment, a pad type shielding with a thickness of 1 mm was prepared by mixing $Si-TiO_2$, and the X-ray shielding rate was compared with 0.5 mmPb plate of The shielding rate of shielding of 0.5 mmPb plate 95.92%, 85.26 % based on the case of no shielding under each 60 kVp, 100 kVp tube voltage condition. When the shielding of $Si-TiO_2$ pad was applied, the shielding rate equal to or greater than 0.5 mmPb plate was obtained at a thickness of 11 mm or more, and the shielding rate of 100% or more was confirmed at a thickness of 13 mm in 60 kVp condition. When the shielding of $Si-TiO_2$ pad was applied, the shielding rate equal to or greater than 0.5 mmPb plate was obtained at a thickness of 17 mm or more, and a shielding rate of 0.5 mmPb plate was observed at a thickness of 23 mm in 100 kVp condition. Through the results of this study, We could confirm the possibility of manufacturing radiation protective materials that does not contain lead hazard using various metalic compound and liquid Si. This study shows that possibility of liquid Si and other metalic compound can harmonize easily. Beside, It is flexible and strong to physical stress than Pb obtained radiation protective closthes. But additional studies are needed to increase the shielding rate and reduce the weight.

The Evaluation of Meteorological Inputs retrieved from MODIS for Estimation of Gross Primary Productivity in the US Corn Belt Region (MODIS 위성 영상 기반의 일차생산성 알고리즘 입력 기상 자료의 신뢰도 평가: 미국 Corn Belt 지역을 중심으로)

  • Lee, Ji-Hye;Kang, Sin-Kyu;Jang, Keun-Chang;Ko, Jong-Han;Hong, Suk-Young
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.4
    • /
    • pp.481-494
    • /
    • 2011
  • Investigation of the $CO_2$ exchange between biosphere and atmosphere at regional, continental, and global scales can be directed to combining remote sensing with carbon cycle process to estimate vegetation productivity. NASA Earth Observing System (EOS) currently produces a regular global estimate of gross primary productivity (GPP) and annual net primary productivity (NPP) of the entire terrestrial earth surface at 1 km spatial resolution. While the MODIS GPP algorithm uses meteorological data provided by the NASA Data Assimilation Office (DAO), the sub-pixel heterogeneity or complex terrain are generally reflected due to coarse spatial resolutions of the DAO data (a resolution of $1{\circ}\;{\times}\;1.25{\circ}$). In this study, we estimated inputs retrieved from MODIS products of the AQUA and TERRA satellites with 5 km spatial resolution for the purpose of finer GPP and/or NPP determinations. The derivatives included temperature, VPD, and solar radiation. Seven AmeriFlux data located in the Corn Belt region were obtained to use for evaluation of the input data from MODIS. MODIS-derived air temperature values showed a good agreement with ground-based observations. The mean error (ME) and coefficient of correlation (R) ranged from $-0.9^{\circ}C$ to $+5.2^{\circ}C$ and from 0.83 to 0.98, respectively. VPD somewhat coarsely agreed with tower observations (ME = -183.8 Pa ~ +382.1 Pa; R = 0.51 ~ 0.92). While MODIS-derived shortwave radiation showed a good correlation with observations, it was slightly overestimated (ME = -0.4 MJ $day^{-1}$ ~ +7.9 MJ $day^{-1}$; R = 0.67 ~ 0.97). Our results indicate that the use of inputs derived MODIS atmosphere and land products can provide a useful tool for estimating crop GPP.

The Study of Affecting Image Quality according to forward Scattering Dose used Additional Filter in Diagnostic Imaging System (부가필터 사용 시 전방 산란선량에 따른 화질 영향에 대한 연구)

  • Choi, Il-Hong;Kim, Kyo-Tae;Heo, Ye-Ji;Park, Hyong-Hu;Kang, Sang-Sik;Noh, Si-Cheol;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.597-602
    • /
    • 2016
  • Recent clinical field utilizes the aluminium filter in order to reduce the low-energy photons. However, the usage of the filter can cause adverse effect on the image quality because of the scattered dose that is generated by X-ray hardening phenomenon. Further, usage of filter with improper thickness can be a reason of dose creep phenomenon where unnecessary exposure is generated towards the patient. In this study, the author evaluated the RMS and the RSD analysis in order to have a quantitative evaluation for the effect of forward scattering dose by the filter on the image. as a result of the study, the FSR and the RSD was increased together with the increasing of thickness of the filter. In this study the RSD means the standard deviation of the mean value is relatively size. It can be understood that the signal-to-noise ratio decreases when the average value is taken as a signal and the standard deviation is judged as a noise. The signal-to-noise ratio can understanding as index of resolution at image. Based on these findings, it was quantitatively verified that there is a correlation of the image quality with the FSR by using an additional filter. The results, a 2.5 mmAl which is as recommended by NCRP in the tube voltage of 70 kVp or more showed the 14.6% on the RSD when the filter was not in used. these results are considered able to be utilized as basic data for the study about the filter to improve the quality of the image.

Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols (64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소)

  • Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  • PDF

Repair of Acute Aortic Arch Dissection with Hypothermic Circulatory Arrest and Retrograde Cerebral Perfusion (저체온순환정지와 역행성 뇌관류에 의한 대동맥궁을 침범한 급성 대동맥 박리증의 수술결과)

  • 이삼윤
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.43-49
    • /
    • 2004
  • Background: Acute thoracic aortic dissections involving the aortic arch differ in diagnosis, surgical procedures, and operative results compared to those that do not involve the aortic arch. In general cerebral perfusion under deep hypothermic circulatory arrest (HCA) is performed during the repair of the aortic arch dissection. Here, we report our surgical results of the aortic arch dissection repair using retrograde cerebral perfusion (RCP) and its safety. Material and Method: Between January 1996 and June 2002, 22 consecutive patients with aortic arch dissection underwent aortic arch repair. In 20 of them RCP was performed under HCA. RCP was done through superior vena cava in 19 patients and by systemic retrograde venous perfusion in 1, in whom it was difficult to reach the SVC. When the patient's rectal temperature reached 16 to 18$^{\circ}C$, systemic circulation was arrested, and the amount of RCP amount was 481.1 $\pm$292.9 $m\ell$/min with perfusion pressure of 20∼30 mmHg. Result: There were two in-hospital deaths (4.5%) and one late death (9.1%). Mean circulatory arrest time (RCP time) was 54.0$\pm$ 13.4 minutes (range, 7 to 145 minutes). RCP time has no correlation with the appearance of consciousness, recovery of orientation, or ventilator weaning time (p=0.35, 0.86, and 0.92, respectively). Ventilator weaning was faster in patients with earlier recovery of consciousness and orientation (r=0.850, r=926; p=0.000, respectively). RCP of more than 70 minutes did not affect the appearance of consciousness, recovery of orientation, ventilator weaning time, exercise time, or hospital stay (p=0.42, 0.57, 0.60, 0.83, and 0.51, respectively). Conclusion: Retrograde cerebral perfusion time under hypothermic circulatory arrest during repair of aortic arch dissection may not affect recovery of orientation, ventilator weaning time, neurologic complications, and postoperative recovery.

Comparison of the Low Potassium Dextran Solution and ET-Kyoto Solution in Rabbit Lung (토끼 폐장 분리관류 모형을 이용한 LPD 폐보존액과 ET-Kyoto 폐보존액의 비교)

  • Lim, Cheong;Kim, Kyung-Hwan;Kim, Young-Tae;Sung, Sook-Whan;Kim, Joo-Hyun
    • Journal of Chest Surgery
    • /
    • v.30 no.12
    • /
    • pp.1159-1166
    • /
    • 1997
  • For Improvement of lung preservation, many tripes of preservation solution were developed and tested. The aim of this study was to compare the effect of the most frequently used extracellular type pieservation solution (Low Potassium Dextran, LPD) with a newly developed trehalose containing extracellular type preservation solution(ET-Kyoto, ETK) on postischemic lung function. Twelve New-Zealand white rabbit lungs were harvested and studied on an isolated, blood-perfused model of lung function after 4 hours of cold ischemia at $10^{\circ}C$ In group I (n=6), lungs were preserved with 100 mL/kg of LPD solution; in group II(n=6), lungs were preserved with 100 mL/kg of ETK solution. A few minutes before flushing with preservation solutions, 20$\mu\textrm{g}$ of PGEI were injected into main pulmonary artery. Functions of the preserved lung were compared with PO2, PA pressure, t acheal air pressure, and drylwet ratio. The pulmonary efferent blood oxygen tension at the end of the 60-minute reperfusion period was higher in group II compacted with group I(486.5 $\pm$ 80.3 mmHg versus $432.5\pm82.9$ mmHg at FiO2 1.0, p-value = NS). The mean pulmonary arterial pressure was similar in both $groups.(33.7\pm2.2$ mmHg versus $35.5\pm2.0$ mmHg, p-value : NS). The peak inspiratory airway pressure was significantly lower in group 11(8.010.6 mmHg versus 11.8 $\pm$ 1.4 mmHg, p-value=0.02) The water content of the lung was lower in group II $(70.2\pm6.9%$ versus 78.5 $\pm6.1%),$ but not significant. These data demonstrate that a newly-developed trehalose-containing ET-Kyoto solution yield equal or slightly superior lung function after reperfusion compared with LPD solution.

  • PDF

Development and Validation of an Analytical Method for Ametoctradin Residue Determination in Domestic Agricultural Commodities by HPLC-PDA (HPLC-PDA를 이용한 국내 유통 농산물 중 ametoctradin 잔류량 분석법 개발 및 검증)

  • Do, Jung-Ah;Kwon, Ji-Eun;Lee, Eun-Mi;Kim, Mi-Ra;Kuk, Ju-Hee;Cho, Yoon-Jae;Kang, Il-Hyun;Kim, Hyung-Su;Kwon, Kisung;Oh, Jae-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.3
    • /
    • pp.285-292
    • /
    • 2013
  • This study was carried out to validate the safety of ametoctradin residues in agricultural commodities by developing an official analysis method. An analytical method was developed and validated using HPLC-PDA detectors. The samples were extracted with methanol, subsequently partitioned with dichloromethane and purified with florisil column chromatograph using acetone/hexane (30/70, v/v) as solvent. The method was validated by using grape, hulled rice, mandarin, and potato spiked with ametoctradin at 0.05 and 5.0 mg/kg, and pepper at 0.05 and 2.0 mg/kg. Average recoveries were 76-114.8% with relative standard deviation less than 10%, and the limit of detection and limit of quantification were 0.0125 and 0.05 mg/kg, respectively. The result of recoveries and overall coefficient of variation of the laboratory results from Gwangju regional Food and Drug Administration (FDA) and Daejeon regional FDA was accorded with Codex Alimentarius Commission Guideline (CAC/GL 40). Based on these results, this method was found to be appropriate for ametoctradin residue determination and can be used as the official method of analysis.