• 제목/요약/키워드: 압축 및 휨강도

Search Result 553, Processing Time 0.028 seconds

Mechanical Properties of Green Strain-Hardening Cement-based Composites with Recycled Materials (순환재료를 사용한 그린 변형 경화형 시멘트 복합체의 역학적 특성)

  • Yun, Hyun-Do;Kim, Sun-Woo;Lee, Young-Oh;Nam, Sang-Hyun;Cha, Jun-Ho;Kim, Yun-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.399-400
    • /
    • 2010
  • This paper presents results of an experimental program for evaluating the mechanical properties of green strain-hardening cementitious composite (SHCC) using recycled material. Recycled poly ethylene terephthalate (PET) fiber, fly ash, and recycled sand from waste concrete are used as materials for green SHCC. Test results indicated that average tensile strength of five dumbbell-shaped specimen is 4.76MPa and average compressive and flexural strength of three specimens are 38MPa and 7.40MPa, respectively.

  • PDF

A study on evaluation of flexural toughness of synthetic fiber reinforced shotcrete (구조용 합성섬유 보강 숏크리트 휨인성 평가에 관한 연구)

  • Moon, Kyoung-Sun;Kim, Seog-Jin;Kim, Yeon-Deok;Min, Byeong-Heon;Kim, Sang-Hwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.3
    • /
    • pp.433-452
    • /
    • 2019
  • This study deals with shotcrete reinforcing performance according to the amount of synthetic fiber (PP fiber) and proper evaluation method. The shotcrete compressive strength, flexural strength and flexural toughness were tested by setting the mixing amounts of steel fiber ($37.0kg/m^3$) and synthetic fiber (PP fiber) as parameters ($5.0kg/m^3$, $7.0kg/m^3$ and $9.0kg/m^3$). Particularly, circular panel flexural toughness test (Road and Traffic Authority, RTA) was performed to evaluate the shotcrete energy absorption capacity. As a result, the compressive strength and the bending strength of the steel fiber reinforced shotcrete were large, but the flexural toughness of the synthetic fibe (PP fiber) reinforced shotcrete was large. Therefore, synthetic fiber (PP fiber) reinforced shotcrete is considered to have a reinforcing effect comparable to that of steel fiber reinforced shotcrete. Analysis of the relationship between the flexural toughness and the energy absorption capacity of synthetic fiber (PP fiber) reinforced shotcrete revealed that the energy absorbing ability is exhibited at a flexural toughness lower than the allowable standard (3.0 MPa). (Class A: 2.55 MPa = 202J, Class B: 2.72 MPa = 282J, Class C: 3.07 MPa = 403J). As a result of this study, it can be concluded that the actual shotcrete support performance can be evaluated by evaluating the support performance of the shotcrete measured at less than the allowable standard (3.0 MPa) at the actual tunnel site.

Comparative Study on Test Methods for Mechanical Properties of Structural Adhesives Used in FRP Strengthening (구조보강용 FRP 함침·접착수지의 역학적 특성 분석을 위한 시험방법 비교 연구)

  • You, Young Chan;Choi, Ki Sun;Kim, Keung Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.2
    • /
    • pp.103-112
    • /
    • 2008
  • Pull-off test is generally used to evaluate bond strength of FRP composite with concrete at job site. However, some damages on FRP composites can not be avoided during pull-off test and moreover test range of pull-off strength is limited by maximum tensile strength of concrete. Accordingly, it is required to set-up a test method that can evaluate mechanical properties of structural adhesive indirectly prior to pull-off test. In this study, the standard test methods for structural adhesive which can simply evaluate mechanical performance of adhesive were suggested through comparative experiments from each different standard in various countries. Particularly, gluing thickness of adhesive in tensile lap-shear tests, the section dimension of compression and bending test specimens become unified, and standard test specimen size is achieved by test results.

Flexural Characteristics of Reinforced Polymer Concrete T-Beams Strengthened with GFRP (GFRP 보강 철근 폴리머 콘크리트 T형 보의 휨 특성)

  • Jin, Nan-Ji;Hwang, Hae-Geun;Yeon, Jung-Heum
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.5
    • /
    • pp.585-596
    • /
    • 2012
  • In this study, the flexural characteristics of reinforced polymer concrete T-beams strengthened with GFRP, typically used for bridges and parking structures, are investigated. A method to determine the flexural failure mode of reinforced polymer concrete T-beams comprised of compression failure (CF), tension failure (TF), and fiber sheet failure (FF) for different levels of GFRP strengthening is proposed. Moreover, the present study provides a formula to calculate the design flexural strength for each failure mode. In reinforced polymer concrete T-beams strengthened with GFRP, an ideal failure mode can be achieved when the failure occurs in the following order: 1) yield of steel reinforcement, 2) failure of GFRP, and 3) compression failure of concrete. In the case of FF mode, due to GFRP failure before the polymer concrete crushing in compression region, a concept of equivalent rectangular block based on the ultimate limit state of concrete should not be used. Thus, this study suggests an idealized stress-strain curve for polymer concrete and finds parameters for stress block, ${\alpha}$ and ${\beta}$ based on the strain distribution in polymer concrete. Furthermore, the present study suggests an aspect ratio of 2.5 by examining the compressive stress distribution and design flexural strength characteristics for different aspect ratio of T-beams. This study also provides a design flexural strength formula, and validates its acceptability based on experiment and theoretical analysis.

Resistance of Freeze-Thaw and Strength Development of Recycled Concrete (재생콘크리트의 강도발현 및 동결융해 저항성 특성)

  • 이진용;이인대;김광우;배성용
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.4
    • /
    • pp.163-169
    • /
    • 1998
  • The strength and freeze-thaw test were carried out in order to use recycled aggregate as crushed aggregate in concrete. The recycled concrete had a lower flexture and compressive strengths than ordinary concrete, but the inclusion of fly ash shows similar results in both concretes. The resistance of freeze-thaw was strongly influenced by W/C ratio, content of recycled aggregate and fly ash, and it was also found that the resistance was higher when W/C ratio and fly ash content was lower. and was superior when replacement level of recycled aggregate reached to 80%.

A Study on the Engineering Characteristics of High Strength Concrete used by high Calcium Sulfate Cement (고황산염 시멘트를 이용한 고강도콘크리트의 공학적 특성에 관한 연구)

  • 박승범;임창덕
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.10a
    • /
    • pp.11-18
    • /
    • 1992
  • 프리텐션방식 원심력 고강도콘크리트 말뚝(KS F4306) 콘크리트의 압축강도가 800kg/$\textrm{cm}^2$이상인 고강도콘크리트를 요구하고 있으나 국내에서는 500kg/$\textrm{cm}^2$ 이상의 콘크리트 말뚝제조가 불가한 실정이므로 본 연구에서는 고황산염시멘트를 이용한 고강도콘크리트 말뚝제조에 관한 공학적 특성 연구의 일환으로써 고황산염시멘트의 수화특성 및 고강도 발현기구 구명과 공학적 특성중에서 압축.휨강도의 내동해성, 건조수축 특성 및 화학저항성등을 비교 고찰하여 보통 시멘트보다 품질 특성이 우수함을 확인하였다. 또한 고강도 콘크리트 말뚝의 시제품 제조를 위하여 2개 공장에서 현장 실험한 결과 94.7kg/$\textrm{cm}^2$의 양호한고강도콘크리트를 얻었다. 향후 고강도콘크리트 말뚝 제조의 공업화 및 양산회가 기대된다.

  • PDF

Mechanical Behavior and Optimum Mix Design of High Strength Concrete with Condensed Silica Fume Admixtures (실리카 흄을 사용한 고강도 콘크리트의 역학적 특성과 최적배합연구)

  • 오병환;엄주용
    • Magazine of the Korea Concrete Institute
    • /
    • v.1 no.1
    • /
    • pp.75-86
    • /
    • 1989
  • 본 본문에서는 실리카 흄을 사용한 고강도 콘크리트의 제조와 역학적 특성 및 최적 배합에 대한 실험적 연구를 수행하였다. 본 본문에서는 주요 실험변수를 물-시멘트비와 혼화재인 실리카 흄의 혼입량으로 정하였으며, 압축강도 및 휨강도와 합렬인장강도 특성을 분석하였다. 실리카흄의 혼입으로 강도가 증가함을 발견하였으나 어느 범위이상의 과도한 혼입은 오히려 강도를 저해하는 것으로 나타났다. 물-시멘트비 0.28에서는 실리카 흄 혼입량이 5%일 때 최대의 강도가 나타났고, 물-시멘트비 0.40에서는 15%, 물-시멘트비 0.55에서는 20%혼입에서 가장 큰 강도가 나타났다. 또한 본 연구에서는 압축강도와 물-시멘트비 및 실리카 흄량 사이의 관계를 도출하여 그 관게식을 제시하였으며, 이 식으로부터 소요강도를 위한 본 배합변수를 유추할 수 있다. 본 연구결과 물-시멘트비 효과와 실리카 흄의 효과가 상쇄되는 구간이 존재하며, 따라서 이들 효과를 함께 고려한 최적배합을 도출하여 제시하고 있다.

The Evaluation of Mechanical Properties of Ultra High Performance Concrete with Using Steel Fiber of Wave Type (물결형 강섬유를 이용한 초고성능 콘크리트의 역학적 특성 평가)

  • Ryu, Gum-Sung;Koh, Kyung-Taek;Kang, Su-Tae;Park, Jung-Jun;Kim, Sung-Wook
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.353-356
    • /
    • 2008
  • UHPC which was a structural material exhibiting very remarkable mechanical performances with compressive strength, tensile strength and flexural strength rising up to 200MPa, 15MPa and 35MPa, respectively. In addition, this material presents exceptional durability regard to the very low diffusion and penetration speeds of noxious substances like chloride ions This study was carry out to evaluate the effect of flexural behavior according to steel fiber type in UHPC. The results is showing that the steel fiber type have remarkable influence flexural strength Addition to it is showing that steel fiber type made little difference in the first cracking strength but considerable gap in the ultimate flexural strength to use the steel fiber of wave type.

  • PDF

An Evaluation of Axial Compressive Strength in Steel Stud (스틸스터드의 압축내력 평가)

  • Shin, TaeSong
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.4 s.37
    • /
    • pp.677-689
    • /
    • 1998
  • In relation to concentrically loaded compression, this research is to describe, analyze, and evaluate the design strength in steel stud. The similarity and difference among load and resistance factor design specification for cold-formed steel structural members (AISI), cold-formed thin gauge members and sheeting (EC3 part 1.3), and German draft (DASt-Richtlinie 016) are introduced, discussed, and systematically evaluated. Especially, the effective width and global instability problems (flexural buckling and torsional flexural buckling) are here implied in this research. The design axial strength by dual standards (AISI and EC3) is calculated and compared using the example.

  • PDF

Effect of Volume Fraction of Fibers on the Mechanical Properties of a Lightweight Aggregate Concrete Reinforced with Polypropylene Fibers (섬유 혼입률에 따른 섬유보강 경량골재 콘크리트의 역학적 특성)

  • Lee, Haeng-Ki;Song, Su-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.6 s.96
    • /
    • pp.743-748
    • /
    • 2006
  • This paper presents results of an experimental study conducted to investigate the effect of volume fraction of fibers on the mechanical properties of a fiber-reinforced, lightweight aggregate concrete(FRLAC) that was produced without an autoclave process. The FRLAC enhanced the strength of lightweight, cellular concrete by adding polypropylene fibers and lightweight aggregates. To investigate the effect of volume fraction of fibers on the mechanical behavior of FRLAC and to determine the optimal volume fraction of fibers, a series of compression and flexural strength tests on FRLAC specimens with various fiber volume fractions(0%, 0.10%, 0.25%, 0.50%) were conducted. It was observed from the tests that a 0.25% volume fraction of fibers maximized the increase in the strength of FRLAC and the fibers controlled cracking in FRLAC.