• Title/Summary/Keyword: 압력 신호

Search Result 347, Processing Time 0.021 seconds

Properties of Smart Vapor Self-Releasing Composite Films to Microwave Packaging (증기 자가방출 스마트 전자레인지 포장재 적용을 위한 복합필름 특성연구)

  • Wooseok, Song;Hojun, Shin;Jongchul, Seo
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.3
    • /
    • pp.157-163
    • /
    • 2022
  • The demands for Home Meal Replacement (HMR) products are continuously increasing owing to the convenience of instant food and online food delivery. Ready-to-heat (RTH) products have received massive attention in the HMR industry because these products can be easily warmed using a microwave oven. However, the conventional microwave packaging should be opened before microwave heating to prevent bursting or food loss owing to the steam-pressure build-up inside the package. Open packaging might lead to non-uniform food heating and cross-contamination. Therefore, packaging materials that are able to release steam without opening are of interest to the HMR industry. In this study, polylactic acid(PLA)/polyethylene glycol(PEG)/nanoclay composite films were manufactured using an extrusion method as packaging materials with a smart steam-releasing function. The introduction of PEG to the PLA imparted a steam self-releasing feature to the composite films owing to the morphology change of composite films during microwave heating. Further, PEG increased the ductility of PLA, which in turn prevented bursting caused due to the steam-pressure build-up. The uniform dispersion of nanoclay obtained by a twin-screw extrusion led to stronger mechanical properties. Therefore, the smart composite films developed here can be applied as microwave packaging materials with a self-releasing function.

Study on the Plan to Reduce the EVENT of the Gas Regulator (정압기 EVENT 감소방안 연구)

  • Kang-ok Yun;Tae-jun Eom;Ki-beom Kim;Yong-woo Lee;Hyoung-Min Lee;Byeong-Geun Gong
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.1
    • /
    • pp.57-62
    • /
    • 2023
  • The Gas Regulator EVENT is a signal sent by the Remote Terminal Unit(RTU) installed in each local gas regulator (hereinafter referred to as "regulator"), and is an abnormal alarm that can be intuitively checked in our client server. This is an important data that enables immediate dispatch order and initial action in the situation room when a regolator abnormality occurs, and can analyze the cause of the regulator abnormality. Looking at the trend of EVENT data for regulator over the past three years, there is a clear trend of increasing unchecked EVENT data. The increase in non-checking event (actual abnormality or noise event) may mean that firstly, mechanical or pressure abnormality occurs in the actual regulator, and secondly, there is no abnormality in the actual regulator, but communication error occurred in the RTU, reset. EVENT Data may be formed as if an abnormality occurred in the static voltage due to an error, sensor error, power failure (instantaneous power failure), etc. Among them, this study analyzed the recently generated unchecked EVENT data to identify critical noise events among RTU errors, which are noise events, and reviewed ways to increase the reliability of Regulator EVENTs by reducing them.

Finite element analysis for acoustic and temperature characteristics of a piezoelectric HIFU transducer at 10 MHz (10 MHz용 압전 HIFU 트랜스듀서의 음향 및 온도 특성에 대한 유한요소해석)

  • Jong-Ho Kim;Il-Gok Hong;Ho-Yong Shin;Hyo-Jun Ahn;Jong-In Im
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.33 no.3
    • /
    • pp.116-123
    • /
    • 2023
  • A high intensity focuses ultrasound (HIFU) is one of the emerging technologies in the biomedical field. The piezoelectric HIFU transducer is a device that utilizes the thermal energy generated by high ultrasound energy. Recently an operating frequency of the HIFU transducer is to expand above a 7 MHz. In this study, the acoustic pressures and temperature distributions in the tissue that generated by the HIFU transducer at 10 MHz were calculated with the finite element method. In addition, the pressure focusing characteristics of the device were analyzed. The geometrical variables are the piezomaterial thickness, lens shape, water height, and film thickness. The results shown that the acoustic pressure increased and saturated gradually when the height/radius (HL/RL) ratio of the lens increased. Moreover, the focal area was gradually decreases with HL/RL ratio of the lens. In case of the optimized HIFU transducer, the maximum pressure and temperature were analyzed about 19 MPa and 65℃ respectively. And the -3 dB focused distances in the axial and lateral direction are around 2.3 mm and 0.23 mm respectively.

The Effect of Contamination of Ion Source on Ionic Current of Quadrupole Mass Spectrometer (사중극 질량 분석기의 이온소스 오염이 이온전류에 미치는 영향)

  • Lee, K.C.;Park, C.J.;Kim, J.T.;Oh, E.S.;Hong, K.S.;Hong, S.S.;Lim, I.T.;Yun, J.Y.;Kang, S.W.;Shin, Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.3
    • /
    • pp.197-202
    • /
    • 2009
  • The long term stability of ion current of QMS has been one of key parameters for monitoring gas process in vacuum. The time dependence of ionic current was monitored while the pressure of nitrogen gas was kept at a fixed pressure by introducing the gas into vacuum chamber. The chamber was evacuated to ${\sim}3{\times}10^{-9}\;Torr$ to reduce background signals before the measurement. Two ion sources were tested; one had brownish or black color due to gas contamination and the other one was new, i.e. cleaner. At a nitrogen pressure of $1{\times}10^{-5}\;Torr$, the ionic currents measured by the contaminated ion source decreased faster with time. The decrease rate was respectively ${\sim}46%$ for cleaner one and ${\sim}84%$ for contaminated one after ${\sim}5.5%$ hours. In order to test the effect of filament material on the ion current decrease, we fabricated a tungsten(W) filament which consisted of two parts; one half was made of W and the other was coated with yttria. The similar decrease of ionic currents were shown for the two types of filaments, indicating that slight change of temperature of filament due to material difference i.e. baking effect could not improve the origin of ionic current decrease. Overall the decreasing rate of ionic current is more closely associated with contaminated ion source of QMS rather than its filament materials.

The Application of Impulse Oscillometry(IOS) in the Detection of Smoking Induced Early Airway Obstruction (Impulse Oscillometry(IOS)를 이용한 흡연자에서의 조기 기도폐쇄의 연구)

  • Kim, Youn-Seup;Kweon, Suk-Hoe;Song, Mi-Young;Yoo, Sun-Mi;Park, Jae-Seuk;Jee, Young-Koo;Lee, Kye-Young;Kim, Keun-Youl
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1030-1039
    • /
    • 1997
  • Background : Impulse Oscillometry is a noninvasive and effort-independent test used to characterize the mechanical impedance of the respiratory system. The clinical potential of the IOS is rapid and demands only passive cooperation which makes it especially appealing for children, for epidemiologic surveys and for conditions in which quiet breathig instead of forced expiratory maneuvers are preferred. However, several studies have shown conflicting results that the role of IOS about detection of smoking induced small airway diseases or early airway obstruction Methods : Study was to evaluate the clinical ability of the IOS to detect about smoking induced early airway obstruction in persons with normal spirometry test. Respiratory asymptomatic study groups were formed that one is non-smoking group, another is smoking group. Results : The parameters of spirometry were not significantly differences between non-smoking group and smoking group. Among the parameters of IOS, total resistance(non-smoking group : smoking group=$2.22{\pm}1.20$ : $2.58{\pm}1.71$), peripheral resistance($1.25{\pm}0.62$ : $1.47{\pm}0.10$), bronchial compliance($0.44{\pm}0.12$ : $0.47{\pm}0.16$) were not statistically significant different (p<0.05), but central resistance and lung compliance were not statistically significant different (unit ; resistance=hPa/l/s, compliance=l/hPa). Resistance(Rrs) was not statistically significant different with changes of frequences(5, 10, 15, 20, 25, 30, 35Hz), but Reactance(Xrs) was statistically significant different with low frequences that X5(non-smoking group : smoking group=$-0.62{\pm}0.28$ : $-0.76{\pm}0.48$, p<0.001) and X10($-0.06{\pm}0.19$ : $-0.15{\pm}0.33$, p<0.013) (unit; hPall/s, $hPa{\cong}cmH_2O$). Conclusion : Impulse oocillometer(IOS) is clinically available method to detect about smoking induced early airway obstruction. And clinically potential parameters of IOS were considers that total resistance, peripheral resistance, bronchial resistance, and reactance of low frequency at 5Hz, 10Hz.

  • PDF

A Study on the Effects of the Institutional Pressure on the Process of Implementation and Appropriation of System: M-EMRS in Hospital Organization (시스템의 도입과 전유 과정에 영향을 미치는 제도적 압력에 관한 연구: 병원조직의 모바일 전자의무기록 시스템을 대상으로)

  • Lee, Zoon-Ky;Shin, Ho-Kyoung;Choi, Hee-Jae
    • Asia pacific journal of information systems
    • /
    • v.19 no.2
    • /
    • pp.95-116
    • /
    • 2009
  • Increasingly the institutional theory has been an important theoretical view of decision making process and IT adoption in many academic researches. This study used the institutional theory as a lens through which we can understand the factors that enable the effective appropriation of advanced information technology. It posits that mimetic, coercive, and normative pressures existing in an institutionalized environment could influence the participation of top managers or decision makers and the involvement of users toward an effective use of IT in their tasks. Since the introduction of IT, organizational members have been using IT in their daily tasks, creating and recreating rules and resources according to their own methods and needs. That is to say, the adaptation process of the IT and outcomes are different among organizations. The previous studies on a diverse use of IT refer to the appropriation of technology from the social technology view. Users appropriate IT through not only technology itself, but also in terms of how they use it or how they make the social practice in their use of it. In this study, the concepts of institutional pressure, appropriation, participation of decision makers, and involvement of users toward the appropriation are explored in the context of the appropriation of the mobile electronic medical record system (M-EMRS) in particularly a hospital setting. Based on the conceptual definition of institutional pressure, participation and involvement, operational measures are reconstructed. Furthermore, the concept of appropriation is measured in the aspect of three sub-constructs-consensus on appropriation, faithful appropriation, and attitude of use. Grounded in the relevant theories to appropriation of IT, we developed a research framework in which the effects of institutional pressure, participation and involvement on the appropriation of IT are analyzed. Within this theoretical framework, we formulated several hypotheses. We developed a second order institutional pressure and appropriation construct. After establishing its validity and reliability, we tested the hypotheses with empirical data from 101 users in 3 hospitals which had adopted and used the M-EMRS. We examined the mediating effect of the participation of decision makers and the involvement of users on the appropriation and empirically validated their relationships. The results show that the mimetic, coercive, and normative institutional pressure has an effect on the participation of decision makers and the involvement of users in the appropriation of IT while the participation of decision makers and the involvement of users have an effect on the appropriation of IT. The results also suggest that the institutional pressure and the participation of decision makers influence the involvement of users toward an appropriation of IT. Our results emphasize the mediating effect of the institutional pressure on the appropriation of IT. Namely, the higher degree of the participation of decision makers and the involvement of users, the more effective appropriation users will represent. These results provide strong support for institutional-based variables as predictors of appropriation. These findings also indicate that organizations should focus on the role of participation of decision makers and the involvement of users for the purpose of effective appropriation, and these are the practical implications of our study. The theoretical contribution of this study is lies in the integrated model of the effect of institutional pressure on the appropriation of IT. The results are consistent with the institutional theory and support previous studies on adaptive structuration theory.

4D Printing Materials for Soft Robots (소프트 로봇용 4D 프린팅 소재)

  • Sunhee Lee
    • Fashion & Textile Research Journal
    • /
    • v.24 no.6
    • /
    • pp.667-685
    • /
    • 2022
  • This paper aims to investigate 4D printing materials for soft robots. 4D printing is a targeted evolution of the 3D printed structure in shape, property, and functionality. It is capable of self-assembly, multi-functionality, and self-repair. In addition, it is time-dependent, printer-independent, and predictable. The shape-shifting behaviors considered in 4D printing include folding, bending, twisting, linear or nonlinear expansion/contraction, surface curling, and generating surface topographical features. The shapes can shift from 1D to 1D, 1D to 2D, 2D to 2D, 1D to 3D, 2D to 3D, and 3D to 3D. In the 4D printing auxetic structure, the kinetiX is a cellular-based material design composed of rigid plates and elastic hinges. In pneumatic auxetics based on the kirigami structure, an inverse optimization method for designing and fabricating morphs three-dimensional shapes out of patterns laid out flat. When 4D printing material is molded into a deformable 3D structure, it can be applied to the exoskeleton material of soft robots such as upper and lower limbs, fingers, hands, toes, and feet. Research on 4D printing materials for soft robots is essential in developing smart clothing for healthcare in the textile and fashion industry.