• Title/Summary/Keyword: 압력회수율

Search Result 105, Processing Time 0.019 seconds

Monitoring of Aflatoxins on Commercial Herbal Medicines (유통생약의 아플라톡신 모니터링)

  • Park, Seung-Young;Moon, Hyun-Ju;Cho, Soo-Yeul;Lee, Jun-Gu;Lee, Hwa-Mi;Song, Ji-Young;Cho, Ok-Sun;Cho, Dae-Hyun
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.4
    • /
    • pp.315-321
    • /
    • 2011
  • This study was performed to investigate contamination levels of aflatoxins, the secondary metabolites produced by fungi Aspergillus flavus and A. parasiticus, in herbal medicine. Herbs is susceptible to these fungi infections through its growth harvest, transport and storage. This study determine the aflatoxin $B_1$, $B_2$, $G_1$ and $G_2$ levels by HPLC-florescence detector coupled with photochemical enhancement in 558 samples herbal medicine distributed in Korea and China. Also, We checked a transfer ratio of aflatoxins from raw herbal medicines to herbal medicine extract. Hot water extraction of herbal medicines was prepared by air pressure and high pressure condition. The analytical method for aflatoxins was validated in this method. In results recoveries of the analytical method were ranged from 67.4% to 96.2% and, limits of detection and quantitation for aflatoxins were $0.015{\sim}0.138\;{\mu}g/kg$ and $0.046{\sim}0.418\;{\mu}g/kg$, respectively. According to the results of monitoring on aflatoxins in herbal medicine, aflatoxins 1.7 ug/kg $B_1$ and 0.9 ug/kg $G_1$ were detected in only one sample of Strychni Ignatii Semen, and 0.8 ug/kg $G_1$ in Strychni Semen. About 13.6~51.3% of aflatoxins were transferred to hot water extract. Although the detected levels are under the permitted levels for aflatoxins in herbal medicine, these amounts should be considered in regard to overall daily exposure to mycotoxins.

Characteristics of Wheat Germ Oil during Enzymatic Ethanolysis in Supercritical Carbon Dioxide (초임계 이산화탄소에서 밀배아유의 효소적 에탄올화 반응 특성)

  • Back, Sung-Sin;Kwon, Kyung-Tae;Jung, Go-Woon;Ahn, Hyaung-Min;Sim, Jeong-Eun;Kang, Hee-Moon;Chun, Byung-Soo
    • Korean Chemical Engineering Research
    • /
    • v.47 no.5
    • /
    • pp.546-552
    • /
    • 2009
  • Enzymatic ethanolysis of wheat germ oil with immobilized lipase was investigated for enhancing the function of wheat germ oil. Ethanolysis reactions were carried out in two different systems; non-pressurized and pressurized system. In non-pressurized system, the enzymatic ethanolysis was carried out in an erlenmeyer flask(25 ml) containing a mixture of wheat germ oil and 99.90% ethanol using 1~5 wt% immobilized lipase as Lipozyme TL-IM and Lipozyme RM-IM and the reaction mixtures were incubated at $40{\sim}70^{\circ}C$ with 120 rpm shaking. In pressurized system, the enzymatic ethanolysis was carried out at various condition; immobilized lipase concentration(2 wt%), reaction time(24 h), reaction temperature($40{\sim}60^{\circ}C$) and reaction pressure(75, 100, 150, 200 bars). The samples obtained from each fraction were analyzed by HPLC for analysing contents of monoglyceride, diglyceride, and triglyceride. The conversion of wheat germ oil relied on the reaction temperature and the concentration of immobilized lipase. The optimum condition of enzymatic ethanolysis in non-pressurized and pressurized systems was at $50^{\circ}C$ and 100 bar.

Development of Portable Preconcentration-Gas Chromatography System for Fast Analysis of Trace Benzene, Toluene and Xylene in Air (대기 중 극미량의 벤젠, 톨루엔 및 자일렌의 신속한 분석을 위한 휴대용 농축-기체 크로마토크래피 시스템 개발)

  • Jung, Young-Rim;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.432-441
    • /
    • 2001
  • An automated on-line portable preconcentration-short column gas chromatograph was developed, which used preconcentrator using adsorption tube with Tenax-GR and Curie-point heating. The developed system operated with 3 steps of processing, preconcentration, thermal desorption, and analysis and cleaning, and could continued operating within 1~2 min cycle. The recoveries of preconcentrator for toluene was ranged between $94.7{\pm}6.6%$ and $103.8{\pm}3.1%$ with less than 7% of RSD. For benzene, toluene and xylene(BTX) standard gas test, IDL was 41, 49, $472ng/m^3$ benzene, toluene and o-xylene, respectively. The BTX mixture was analyzed within 30 sec with baseline separation by the system equipped with 4 m long capillary column. The deficiency of separation power caused by short column was solved by the control of sample injection volume and inlet/outlet pressure ratio. The automated portable preconcentration-short column gas chromatograph system was found to be useful for the continuous air monitoring of BTX at ppb levels in ambient air.

  • PDF

Development of $O_2$ Purifier by Pressure Swing Adsorption Process (고순도 산소 생산을 위한 산소 정제 PSA 공정 개발)

  • Lee Chang-Ha;Jee Jeong-Geun;Lee Sang-Jin;Moon Heung-Man;Lee Sang-Hoon
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.1 s.22
    • /
    • pp.37-47
    • /
    • 2004
  • Pressure swing adsorption (PSA) process using CMS as an oxygen purifier was developed to produce high purity oxygen over $99\%$ with high productivity. The cyclic performances such as purity, recovery, and productivity of PSA process were compared experimentally and theoretically under the non-isothermal condition. A binary ($O_2$/Ar 95:5 vol.$\%$) and two kinds of ternary ($O_2/Ar/N_2$ 95:4:1 and 90:4:6 vol.$\%$) mixtures were used as feed gases. The developed process with the consecutive two blowdown steps produced the oxygen with $99.8\%$ purity and $56\%$ recovery from $95\%$ oxygen containing feed. However, in the feed with $90\%$ oxygen, the $O_2$ Purity was decreased up to $97.3\%$. In addition, because the cyclic performances of the suggested process was significantly affected by the diffusion rate, the non-isothermal model with the the modified LDF model was applied for the process simulation. The concentration-dependent rate parameter of the applied rate model was incorporated with the Langmuir isotherm.

  • PDF

Determination of fluoride in fluorite mine wastewater by ion chromatography with post-wash technique (후세척-이온크로마토그래피를 이용한 형석 광산 폐수 중 플루오라이드 정량)

  • Song, Kyung-Sun;Eum, Chul-Hun;Kim, Sang-Yeon
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.383-388
    • /
    • 2006
  • Simple post-wash method by ion chromatography (IC) was established for the rapid and precise determination of fluoride ion in wastewater from mine in fluorite mineralized area. High sulfate in sample was retained in a pre-column and less strongly held fluoride ion was transferred to the principal separation system using modified conventional IC with switching technique. An analytical column with high capacity (AS 9 HC) was used as a pre-column to retain the amount of high sulfate. A guard column (AG 14) as a separation column was used to increase the response of fluoride and reduce the system pressure. According to the recovery of fluoride ion with one detector and the observation of sulfate peak with another conductivity detector, the optimum switching time of 10-port chromatographic injector was 4.3 min. The limit of detection (S/N = 3) of fluoride in synthetic solution containing $500mg\;L^{-1}$ sulfate was $2.4{\mu}g/L$, with $25{\mu}L$ sample volume.