• Title/Summary/Keyword: 압력측정 지그

Search Result 9, Processing Time 0.02 seconds

Effectiveness Evaluation of Displacement Accommodatable Pressure Measuring Jig for Quality Assessment of Pressure Application Device (압력 인가 장치의 품질관리를 위한 변위 수용이 가능한 압력 측정용 지그의 유효성 평가)

  • Mun, Chang-Su;Jun, Sung-Chul;Noh, Si-Cheol
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.2
    • /
    • pp.61-66
    • /
    • 2020
  • Recently, a variety of electric anesthetics devices have been developed and used in clinical practice to reduce the fatigue of the operator during local anesthesia for dental procedures and to compensate for the disadvantages of manual anesthesia device. In this electric anesthesia injection device, the accurate and constant delivery of pressure for drug infusion is a very important performance factor. In order to evaluate the accuracy of the transfer pressure, a small pressure gauge using a load cell is often used, but since the elastic body inside the load cell may not be able to accommodate a sufficient displacement, an error may occur when evaluating pressure performance. For these reasons, in this study, we proposed and evaluated a silicon-chrome steel (Si-Cr steel) spring jig that can accommodate relatively large displacements that can be used when evaluating the performance of a pressure-controlled pressure application device using a load cell type pressure gauge. As a result of the pressure transmissibility test and repeated measurement results using a commercial dental anesthesia injection device, a more stable result was obtained when using a spring jig, and it was confirmed that the frequency of abnormally high measurement was reduced.

Development of a Test Jig for Examination of Radial Pulse Waveform Variations at Different Hold-down Pressures (가압에 따른 요골동맥 맥파 변동 측정을 위한 테스트 지그 개발)

  • Lee, Jeon;Woo, Young-Jae;Jeon, Young-Ju;Lee, Yu-Jung;Kim, Jong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.203-204
    • /
    • 2008
  • 한의학 진단의 중요 요소인 맥진을 자동화한 맥진기에서뿐만 아니라 비관혈적 심혈관 기능 평가를 위해서 요골동맥 맥파 측정이 널리 활용되고 있다. 요골동맥 맥파는 피험자의 생리적, 병리적 원인을 통제하더라도 가압력이 변함에 따라 형태가 달라지며, 어느 시점 맥파를 피험자의 상태를 대표하는 맥파로 해야 할지에 대한 명확한 기준이 없어 맥압이 최대가 되는 시점의 맥파를 사용하고 있다. 그러나, 맥파가 측정되는 가압력 범위뿐만 아니라 맥압이 최대가 되는 시점이 피험자마다 다르기 때문에 정확한 대표 맥파를 획득하기 위해서는 보다 가압력 단계를 늘려야 하며, 결과적으로 측정시간이 보다 길어지게 될 것이다. 본 논문에서는 최소한의 가압단계로도 보다 정확히 대표 맥파를 획득할 수 있는 방법을 개발할 수 있도록, 정밀 제어가 가능한 가압 로봇 축, 가압에 의해 눌리는 피부이동 거리 측정을 위한 레이저 센서, 가압에 따른 피부 반발력과 맥파를 측정할 수 있는 압력 센서로 구성된 테스트 지그를 개발하였다. 이를 통해 모터 이동 스텝 수에 따른 피부 이동 거리 특성, 피부 이동 거리에 따른 맥파 변화 특성 등을 관찰할 수 있었으며, 향후 효과적인 대표 맥파 획득 방법을 개발할 수 있을 것으로 기대한다.

  • PDF

Effect of Measuring Method on the Evaluation of Piezoelectric and Dielectric Properties of PMN-PT Single Crystal (PMN-PT 단결정의 압전 및 유전 특성 평가에 미치는 측정 방법의 영향)

  • Kim, Yong Soo;Park, Jae Hwan;Lee, Jeongho;Lee, Sang Goo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.4
    • /
    • pp.69-74
    • /
    • 2019
  • The influence of measuring fixtures on the measurement of dielectric and piezoelectric properties of PMN-PT single crystal specimens was investigated. As the pressure of the jig pin which applied the AC electrical signal to the sample decreased, the lower resonance resistance was measured and the higher mechanical quality factor was calculated. The mechanical quality factor was 418 when the spring tension of the jig pin was 20grf, and the value of the quality factor was reduced by half when the spring tension was 200grf. The 4-probe fixture method is unsuitable for measuring piezoelectric properties, but it was suitable for the measurement of dielectric loss. In order to accurately evaluate the piezoelectric properties of PMN-PT, it is necessary to lower the spring tension of the jig pin as much as possible.

A development of the Automatic Measuring System for internal pressure of the artillery (화포 내부 압력의 자동 측정시스템 개발)

  • Lee, Jeong-Ho;Kim, Dong-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.766-773
    • /
    • 2021
  • Chemicals, such as ammunition, are disposable items that cannot be reused because of their operational characteristics. The reliability of the test process and test results are important factors in evaluating the performance of guns and ammunition. The pressure after firing is a crucial value in an acceptance test of guns and ammunition performance; hence, accurate measurements are required. The pressure in the artillery is measured using the copper crusher gauge. The compression amount of copper is converted into a pressure by either a length-pressure conversion table or conversion formula. Therefore, the exact measurement of the squeeze of the copper crusher is related directly to the correct estimate of the pressure. Currently, the pressure is measured manually by the operator, which always includes some human error. In this study, the cause of the measurement error was analyzed, and the automatic measuring system for copper crusher deformation was developed to minimize the error elements. A copper crusher could be measured using the probe sensor and CCD camera, and the Jig for stable positioning was also designed. A designated SW was also developed for the system operating and measurement-analysis. This measuring system through this study may be used for an ammunition stockpile reliability test and gun/ammunition acceptance test.

Effect of Measuring Parameters of Tensile Strength of Fiber-reinforced Composite Materials (섬유강화 복합재료의 인장강도 측정변수에 따른 영향)

  • Lee, Jae-Dong;Jin, Young-Ho;Kim, Min-Seok;Son, Hyun-Sik;Kwon, Dong-Jun
    • Journal of Adhesion and Interface
    • /
    • v.22 no.3
    • /
    • pp.85-90
    • /
    • 2021
  • Generally, the tensile strength of carbon fiber reinforced composite (CFRP) should be determined to produce this material. The tensile strength was performed based on ASTM D3039, and this test could cause the error by specimens and human. In this research, the CFRP tensile test was performed with different thickness of specimens and tap, adhesive for attaching tap, and pressure of jig to hold the specimens, while the test was performed based on ASTM D3039. The tensile stress and modulus exhibited differently with different specimen thicknesses, and the 1~1.5 mm thickness of the specimen was optimized. In the case of 0.28 MPa jig pressure, the slip or fracture at the clamping area of the specimen has not occurred, and specimens were fractured to the center section of the specimen. The adhesive to attach jig on specimen should be used to exhibit high adhesive stress. Experimental parameters could cause errors. It is expected to achieve an accurate tensile property evaluation of composite materials via improvements in adhesives, tabs, and jigs.

Design and Implementation of Factory Equipment Monitoring System using Grid-based Key Pre-Distribution (그리드 기반 키 선분배 방식을 사용하는 공장 설비 모니터링 시스템 설계 및 구현)

  • CHO, YANGHUI;PARK, JAEPYO;YANG, SEUNGMIN
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.51-56
    • /
    • 2016
  • In this paper, we propose an Arduino-based plant monitoring system. The proposed system is based on the Arduino platform, using an environmental sensor and a pressure sensor for measuring temperature, humidity and illuminance in order to monitor the state of the environment and the facilities of the plant. Monitoring data are transmitted to a ZigBee coordinator connected to a server through a radio frequency transceiver. When using a pressure sensor and the environment sensor data stored on the host server, checking the pressure in the environment of the plant and equipment is intended to report any alarm status to the administrator. Using a grid line-based key distribution scheme, the authentication node dynamically generates a data key to protect the monitoring information. Applying a ZigBee wireless sensor network does not require additional wiring for the actual implementation of a plant monitoring system. Possible working-environment monitoring of an efficient plant can help analyze the cause of any failure by backtracking the working environment when a failure occurs. In addition, it is easy to expand or add a sensor function using the Arduino platform and an expansion board.

Core Technology Development of Low Temperature Fluidity Test System with Composited Fuel Filter (통합연료필터의 저온유동성 시험장치 핵심기술개발)

  • Yun, Suck-Chang;Zhao, Xiang;Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.18 no.3
    • /
    • pp.420-426
    • /
    • 2014
  • In this paper, we have implemented the low temperature fluidity test system with the composited fuel filter and heater, which has tested the low temperature fluidity of gasoline, an engine start time, the consumption of electricity and power to evaluate the system performance. The test condition have used the diesel fuel, the normal temperature, the diesel fuel supply pressure $3.4kgf/cm^2$ at $-20{\sim}-30^{\circ}C$, the fuel supply quantization 60 l/H, the setting current 30 A and the voltage $13V_{dc}$. In order to simulate the operation of diesel fuel filter, we will establish the composited fuel filter into test jig, and be filled with chamber tank and filter by a constant flow quantization and pressure. After these, it shall be cold for setting time. And then we have measured the consumption current and power of heater, an operating time and pressure of filter.

Characteristics Analysis of 2-pin Sensor Composited Fuel Heater using the Low Temperature Fluidity (저온유동성시험기를 이용한 2-핀용 센서통합연료히터의 특성연구)

  • Xiang, Zhao;Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1230-1235
    • /
    • 2019
  • In this paper, we have developed sensor composited heater of 2-pin, and unified the fuel filter. In order to evaluate the performance of the 2-pin sensor composited fuel heater, we have make of the low temperature fluidity system. The one measure and analysis the electrical and oil flow quantity characteristics at an input and out port of 2-pin sensor composited fuel heater. Especially, in the characteristics verification elements of the proposed goods, we use the test chamber for the temperature variable and oil flow quantity test, and designed an embedded system for interfacing an engine. By interfacing both user and the system, it support an experimental and date gathering function in 2-pin sensor composited fuel filter. And then test the temperature, oil pressure, electrical characteristics and oil flow quantity in variable status from - 30 ℃ to + 80 ℃. These can help us to determine the quality and performance of elementary goods.

A study on the residual stress at the weld joint of 2.25Cr-1.6W heat resistant steel (보일러용 배관재 2.25Cr-1.6W계 내열강의 용접부 응력 해석)

  • Lee, Y.S.;Lee, K.W.;Lee, J.B.;Kim, Y.D.;Kong, B.W.;Ryu, S.H.;Kim, J.T.;Kim, B.S.;Jang, J.C.
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.62-62
    • /
    • 2009
  • 석탄화력발전소의 CO2배출량 감소와 고효율, 대용량화로 인해 초초임계압(USC:Ultra Super Critical) 화력발전소의 건설이 증가하고 있다. USC 발전소는 효율향상을 위한 증기온도와 압력의 상승 때문에 보일러 고온고압부에 기존의 소재에 비해 고온강도와 내산화성의 재료물성이 향상된 신소재 적용이 불가피하다. 특히 사용된 신소재 중에서 보일러 본체를 구성하는 수냉벽관(Water wall), 과열기와, 재열기용 튜브 및 후육부인 헤더와 배관재로 기존의 2.25Cr-1Mo강을 개량한 2.25Cr-1.6W계 내열강이 적용되고 있다. 2.25Cr-1.6W강은 SMI와 MHI가 공동개발한 소재로 1995년 튜브제품이, 1999년에 단조, 파이프재, 플레이트제품이 ASME code case로 등재되었고, 2009년 ASME code case 2199-4로 개정되어 사용 중이다. 이 소재는 2.25Cr-1Mo강에 고온강도 개선을 위해 석출강화효과가 있는 V과 Nb을 첨가하였고, 탄화물의 열적안정성과 고용강화효과 증대를 위해 W을 첨가하였다. 그리고 제작성과 용접성 및 재료의 인성 향상을 위해 B첨가와 C함량을 낮추었다. 합금성분의 첨가와 조정에 의해 고온강도는 개선되었지만, 보일러 설치 및 보수를 위한 용접과정에서 용접금속과 CGHAZ(Coarse Grain HAZ)에서 용접균열이 발생하였다. 대부분의 용접균열은 용접결함이나 고온 혹은 저온균열이 아닌 2.25Cr-1.6W계강의 강도 개선을 위해 첨가한 V과 Nb이 용접후열처리 도중 입내에 MX형태의 미세석출로 입내를 강화시킴으로서 발생한 재열균열 민감성 증대에 기인된 것으로 판단된다. 이에 본 연구에서 용접 및 후열처리 과정에서 용접금속과 HAZ에서 발생하는 용접금속의 응력분포를 전산해석을 통해 확인하고 실제 후육파이프 용접부에서 잔류응력을 측정해 비교하였다. 용접부 응력분포는 SYSWELD 프로그램을 사용해 해석을 수행하였고, 발전소 실배관재의 용접부 응력측정은 수평부 측정이 용이하도록 지그를 부착한 Potable 잔류응력측정기를 사용해 Hole Drilling Method(HDM)를 적용하여 잔류응력을 측정하였다. 해석 결과 CGHAZ부위의 잔류응력이 용접금속과 기타 부위에 비해 높은 응력분포를 나타냈으며, 이는 CGHAZ와 용접용융선 부근에서 균열이 발생하는 실제값과 일치하는 결과를 보였다. 실제 배관재 용접부에서 측정한 잔류응력값은 항복응력의 약 50% 이하 응력값을 나타냈다. 배관 구조에 기인한 시스템응력의 영향을 제거하기 위해 배관재 용접부를 중심으로 양끝단을 절단 후 용접부에서 측정한 응력은 항복응력 대비 25%수준의 낮은값을 보였다. 그러나 배관재가 장기간 고온환경에 노출되었고 용접금속 내부의 균열이 발생한 상태에서 측정하였기 때문에 용접잔류응력은 상당부분 해소되어 상대적으로 낮은 응력값이 얻어진 것으로 판단된다.

  • PDF