• Title/Summary/Keyword: 압력저항계수

Search Result 84, Processing Time 0.026 seconds

Flow Rate Prediction of Pneumatic Pipe System Using Concept of Conductance (컨덕턴스의 개념을 사용한 공압관 시스템의 유량 예측)

  • Kim, Jin-Hyeon;Deng, Ruoyu;Kim, Heuy-Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.5
    • /
    • pp.431-436
    • /
    • 2014
  • Conductance is a concept contrary to flow resistance and is extensively used as a flow index on how easily fluid is transported through a pneumatic pipe or fluid device. However, research on flow conductance is very rare to date, and a systematic investigation is needed for the standardization of pneumatic devices. In the present study, a computational fluid dynamics method was applied to solve the compressible Navier-Stokes equations with two-equation turbulence models. The present CFD results were validated with existing experimental data. The conductance values and friction factors at the inlet and outlet of a pneumatic pipe were used to assess the flow rates. The present results showed that the conductance depends on the pressure ratio at the inlet and outlet of a pipe.

Effect of Measuring Method on the Evaluation of Piezoelectric and Dielectric Properties of PMN-PT Single Crystal (PMN-PT 단결정의 압전 및 유전 특성 평가에 미치는 측정 방법의 영향)

  • Kim, Yong Soo;Park, Jae Hwan;Lee, Jeongho;Lee, Sang Goo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.4
    • /
    • pp.69-74
    • /
    • 2019
  • The influence of measuring fixtures on the measurement of dielectric and piezoelectric properties of PMN-PT single crystal specimens was investigated. As the pressure of the jig pin which applied the AC electrical signal to the sample decreased, the lower resonance resistance was measured and the higher mechanical quality factor was calculated. The mechanical quality factor was 418 when the spring tension of the jig pin was 20grf, and the value of the quality factor was reduced by half when the spring tension was 200grf. The 4-probe fixture method is unsuitable for measuring piezoelectric properties, but it was suitable for the measurement of dielectric loss. In order to accurately evaluate the piezoelectric properties of PMN-PT, it is necessary to lower the spring tension of the jig pin as much as possible.

RF Magnetron Sputter로 증착 한 HfN 박막의 Plasma Power 변화에 따른 Nano-electroribology 특성 변화 연구

  • Park, Myeong-Jun;Kim, Seong-Jun;Kim, Su-In;Lee, Chang-U
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.354.2-354.2
    • /
    • 2014
  • 최근 반도체 산업의 발전에 따라 반도체 소자 내 배선재료로 사용되던 Aluminium (Al)의 대체물로 Copper (Cu)가 사용되고 있다. Cu는 Al보다 우수한 전도성과 비용이 저렴하다는 장점이 있으나 반도체 기판과의 확산으로 이를 해결해야만 하는 문제점이 있다. 이는 Si와 Cu사이에 확산방지막을 사용하여 해결할 수 있는데 Hafnium Nitride (HfN) 박막은 다른 물질과 비교해 고온에서의 안정성과 낮은 비저항을 가지고 있어 주목을 받고 있다. 본 연구에서는 rf magnetron sputter 방법으로 박막 증착 시에 인가하는 rf power가 박막의 표면 특성에 어떠한 영향을 미치는지 nano-indenter를 사용해 surface hardness와 elastic modulus의 변화를 중심으로 알아보았다. 시료는 rf magnetron sputter로 증착 시 인가하는 plasma power를 60W와 80W로 달리하여 증착하였다. 증착가스는 Ar과 $N_2$를 조절하여 사용하였고 총 유량을 40 sccm 으로 고정하였으며, 이 때 압력은 3mTorr로 유지하였다. 실험결과 plasma power를 80W로 인가하여 증착한 시료의 surface hardness (18.48 GPa)가 60W로 증착한 시료의 surface hardness (12.03 GPa)보다 큰 값을 나타내었다. 이와 마찬가지로 80W로 증착한 시료의 elastic modulus(187.16 GPa)도 60W로 증착한 시료의 탄성계수 (141.15 GPa)보다 큰 값을 나타내었다. 이는 증착 시 인가하는 plasma power의 크기가 증가하면 박막표면에 compressive stress가 생성되어 박막의 surface hardness와 elastic modulus가 상대적으로 높게 측정되는 것으로 생각된다.

  • PDF

Fretting Corrosion Behavior of Silver-Plated Electric Connectors with Constant Displacement Amplitude (일정 변위 진폭조건에서의 은도금한 커넥터의 미동마멸부식 거동)

  • Oh, Man-Jin;Kim, Min-Jung;Kim, Taek-Young;Kang, Se-Hyung;Kim, Ho-Kyung
    • Tribology and Lubricants
    • /
    • v.30 no.2
    • /
    • pp.99-107
    • /
    • 2014
  • Fretting corrosion tests are conducted with a constant displacement amplitude using silver-plated brass coupons to investigate the effect of contact pressure on fretting corrosion. Three behaviors are identified based on the change in electric resistance and friction coefficient during the fretting test period, and the identified behaviors are dependent on the magnitude of the applied load. The failure cycle ($N_f$) with an electric resistance of 0.1 D cannot be achieved due to the adhesion behavior of the metal and metal contact under the higher applied load of 0.45 N. This suggests that an average contact pressure higher than 159 MPa for the silver-coated connector is desirable to gain an almost infinite lifetime. The relationship between the electric contact resistance (R) and the average contact pressure (p) can be written as $p=106.2{\times}{\Omega}^{-1.5}$.

A Study on the Pressure Loss in Helically Coiled Tubes (나선코일 튜브 내에서의 압력손실에 관한 연구)

  • Han, K.I.;Bark, J.U.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.155-165
    • /
    • 1998
  • The resistance coefficient and heat transfer performance are studied for the turbulent water flow in a smooth coiled tube having variable curvature ratios and a corrugated-coiled tube having a ratio of coil to tube diameter of 22. Experiments are carried out for the fully developed turbulent flow of water in tube coils on the uniform wall temperature condition. This work is limited to tube coils of R/a between 22 and 60 and Reynolds numbers from 13000 to 53000. The tube having a ratio of coil to tube diameter of 27 among the 3 smooth tube coils shows the best heat transfer performance. A corrugated-coiled tube(R/a=60) shows more excellent performance than a smooth coiled tub (R/a=60) at a similar curvature ratio. The friction factor f is sensitive to changes in the velocity profile caused by a temperature gradient. Allowance was made for the pressure loss in the short inlet and outlet lengths and due to the presence of the thermocouple inlet and outlet as a result of separate experimental on a straight tube. It is to be expected that the allowance at the exit will be somewhat too low because of secondary flow effects carried over from the coil.

  • PDF

A Study on the Assembly Process and Reliability of COF (Chip-On-Flex) Using ACFs (Anisotropic Conductive Films) for CCM (Compact Camera Module) (ACF를 이용한 CCM (Compact Camera Module)용 COF(Chip-On-Flex) 실장 기술 및 신뢰성 연구)

  • Chung, Chang-Kyu;Paik, Kyung-Wook
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.2
    • /
    • pp.7-15
    • /
    • 2008
  • In this paper, the Chip-On-Flex (COF) assembly process using anisotropic conductive films (ACFs) was investigated and the reliability of COF assemblies using ACFs was evaluated. Thermo-mechanical properties of ACFs such as coefficient of thermal expansion (CTE), storage modulus (E'), and glass transition temperature $(T_g)$ were measured to investigate the effects of ACF material properties on the reliability of COF assemblies using ACFs. In addition, the bonding conditions for COF assemblies using ACFs such as time, temperature, and pressure were optimized. After the COF assemblies using ACFs were fabricated with optimized bonding conditions, reliability tests were then carried out. According to the reliability test results, COF assemblies using the ACF which had lower CTE and higher $T_g$ showed better thermal cycling reliability. Consequently, thermo-mechanical properties of ACFs, especially $T_g$, should be improved for high thermal cycling reliability of COF assemblies using ACFs for compact camera module (CCM) applications.

  • PDF

Effect of Emulsified Refine Cooking Oil and Expandable Microsphere on Durability of High-Volume Blast Furnace Slag Concrete (정제유지류 및 팽창성 인공 기포 조합이 고로슬래그 다량치환 콘크리트의 내구성 및 미시적 특성에 미치는 영향)

  • Han, Min-Cheol;Han, Dongyeop;Lee, Myung-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.2
    • /
    • pp.201-207
    • /
    • 2015
  • In this paper, a series of experiments was conducted to evaluate the resistibility of carbonation and freeze-thawing damage of the high-volume blast furnace slag concrete using expancel, the expandable microsphere, and ERCO, emulsified refine cooking oil. The concrete mixture of 0.45 water-to-binder ratio with 60% of blast furnace slag was evaluated for carbonation, freeze-thawing resistibility, SEM, and porosity. According to the previous research, replacing ERCO contributes on improving carbonation resistibility with capillary pore filling effect by soap foaming reaction of ERCO while significantly decreased freeze-thawing resistibility. To improve this decreased freeze-thawing resistibility, expancel was used, and thus freeze-thawing resistibility was improved as the replacement ratio of expancel was increased. It is considered that the selective volume shrunken effect of expancel due to the external pressure and decreased air void spacing factor due to expancel.

Measurements of Turbulent Flow In a$6\times{6}$ Rod Bundle with Spacer Grids (지지격자를 갖는 $6\times{6}$ 봉다발에서의 난류유동 측정)

  • Yang, Sun-Kyu;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.162-174
    • /
    • 1996
  • The local hydraulic characteristics in a single phase flow of a 6$\times$6 rod bundle with neighboring different spacer grids were measured by using a LDV(Laser Doppler Velocimeter) system. 6$\times$6 rod bundle is formed by two 3$\times$6 rod bundles with different spacer grids. The objective of this study in a rod bundle is to investigate the thermal-hydraulic interactions between different spacer grids with different configurations and resistance. By using a LDV system, the velocity and turbulent intensity in axial and horizontal directions ore measured. Pressure drop measurements ore also performed to evaluate the loss coefficient for the spacer grid and the friction factor for rod bundles. Implications concerning thermal mining due to spacer grids were investigated based on the hydraulic test results. Swirl factor, which is assumed as a qualitative criteria for DNB(departure from nucleate boiling), was defined and estimated from the horizontal velocity result.

  • PDF

The Effect of Turbulence Promoters on the Mass Transfer in Ultrafiltration (한외여과에서의 물질전달에 대한 난류촉진물체의 영향)

  • Oh, Won-Suhk;Park, Ham-Yong;Lim, Gio-Bin;Kim, Woo-Sik
    • Membrane Journal
    • /
    • v.4 no.4
    • /
    • pp.221-231
    • /
    • 1994
  • The GR51PP(MWCO 50,000) and GR40PP(MWCO 100,000) membranes manufactured by DDS were used in ultrafiltration of dextran(Mw. : 500,000) solution in flat plate ultrafiltration cell filled with various types of turbulence promoters. The flux improvement by using turbulence promoter was higher in laminar flow region than in turbulent flow region. The maximum improvements of permeate flux were foud as 112% and 50% I laminar flow region and turbulent flow region, respectively. Also, the solute rejection of the ultrafiltration membrane was improved by turbulence promoters and its effect was significant in the high transmembrane pressure and laminar flow region. The smaller the spacer mesh size was used, the higher the flux improved, but the pressure drop in ultrafiltration cell also increased. In laminar flow region, pressure drop by the spacer was negligible, but in turbulent flow region it changed significantly depending upon the mesh size of the spacer and therefore, its mesh size must be baken into account in the design of the process. The predicted results of the modified mass transfer correlation had better agreement with experimental results than those of unmodified one, The modified mass transfer correlations for laminar and turbulent flow region are shown as follow. $N_{sh}=0.151(N_{Re})^{0.199}(N_{Sc})^{0.22}(N_{Scm})^{0.197}\;(625 $N_{sh}=0.0165(N_{Re})^{0.428}(N_{Sc})^{0.33}(N_{Scm})^{0.223}\;(5015

  • PDF

Piezoelectric Properties of Lead-free $Ba(Ti_{0.8}Zr_{0.2})O_3-(Ba_{0.7}Ca_{0.3})TiO_3$ Ceramics for Haptic piezoelectric Actuator (햅틱 압전 액츄에이터용 $Ba(Ti_{0.8}Zr_{0.2})O_3-(Ba_{0.7}Ca_{0.3})TiO_3$ 무면 세라믹스의 압전특성)

  • Park, Min-Ho;Lee, Kab-Soo;Yoo, Ju-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.304-304
    • /
    • 2010
  • 최근 생활에 편리하며 휴대하기 좋은 전자기기들이 개발되고 있다. 휴대폰이나 MP3와 같은 전자기기들은 거의 필수품이라고 할 정도로 우리의 일상생활에 근접하여 있다. 그 종 대표적으로 휴대폰의 종류로 스마트폰과 같은 터치스크린을 이용한 사례는 점차 상승하고 있으며 시간이 지날수록 그 수요는 더욱 많아지고 있다. 때문에 몰입감 제공을 위하여 햅틱장치의 채용이 일반화 되고 있다. 햅틱장치란 가상환경이나 원거리에 있는 환경과 사용자가 상호 작용할 때 사용자에게 촉감이나 힘의 정보를 전달하여 주는 장치로 진동 및 회동 저항에 의해 사용자로 하여금 촉감들 느낄 수 있도록 하는 장치를 뜻한다. 즉, 현실감을 전달을 중점으로 하는 햅틱장치는 빠른 응답 속도와, 진동의 주파수와 크기는 독립적으로 제어가 가능해야 하며 기계적 수용기들을 직접적으로 자극할 수 있어야 한다. 하지만 모바일 햅틱장치의 경우 크기 및 소비전력의 문제로 모든 스펙을 만족하기에는 어려워 좀 더 한정적인 느낌을 제공할 수 없다. 현재까지 모바일 장치에서 햅틱 피드백을 위하여 진동모터나, 솔레노이드, 압전 액츄에이터 등이 많이 사용되어 지고 있다. 그 중 압전 액츄에이터는 입력에너지를 기계적 출력에너지로 변환되는 효과를 이용 한 것으로 압력 센서, 초음파 센서 등 많은 분야에서 응용되고 있으며 변위 범위는 작지만, 크기가 매우 작고 변위 정밀도가 높으며 발생력과 응답속도가 빠르다는 장점이 존재한다. 이를 이용한 햅틱 압전 엑츄에이터의 제작에 사용되는 압전 세라믹스는 높은 전기적 특성을 가질수록 더 졸은 효율을 가지며 이로 인하여 보다 좋은 전기적 특성을 가지는 압전 세라믹스를 필요로 한다. 현재 많이 사용되는 PZT계 세라믹스는 우수한 전기적 특성으로 많이 사용되고 있지만 Pb의 유독성으로 인한 환경문제로 Pb가 포함된 제품을 제한하고 있어 현재 Lead-free의 연구가 이루어지고 있다. Lead-free중 Ba$(Ti_{0.8}Zr_{0.2})O_3$(BZT)는 PZT계 세라믹스를 대체할 차세대 압전 재료로 주목받고 있다. 일반적으로 Lead-free의 압전계수($d_{33}$=100~300pC/N)는 비교적 낮은 값을 보이지만 BZT의 압전계수(BZT $d_{33}$~620pC/N)는 PZT계 세라믹스의 압전계수($d_{33}$=500~600pC/N)와 비교하여 부족하지 않은 압전계수를 보여주며 PZT를 대체할 재료로 주목받고 있다. 본 실험은 햅틱 압전 엑츄에이터용 무연 압전세라믹스의 제작을 위하여 Ba$(Ti_{0.8}Zr_{0.2})O_3-(Ba_{0.7}Ca_{0.3})-TiO_3$(BZT -BCT)의 조성으로 유전 및 압전 특성을 조사하였다.

  • PDF