• Title/Summary/Keyword: 압력저감

Search Result 346, Processing Time 0.029 seconds

An Investigation on the Effect of Fuel Stratification of DME/n-Butane mixture on Reduction of Pressure Rise-Rate in HCCI Combustion (DME/n-Butane 혼합 연료의 농도 성층화에 의한 HCCI엔진연소의 압력 상승률 저감에 관한 연구)

  • Lim, Ock-Taeck;Park, Kyu-Yeol
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.3
    • /
    • pp.39-46
    • /
    • 2011
  • This study investigates the effects of the DME and n-Butane mixture and of the stratification on combustion characteristics of HCCI engine by chemical reaction calculation. First, the existing DME reaction scheme and n-Butane is combined to make new chemical reaction model, then validating the effectiveness of new scheme. Furthermore, this study verify the HCCI combustion characteristics according to the changes of DME and n-Butane mixture ratio, which shows different auto ignition characteristics. Finally, it confirms the effects of stratification of mixture fuel on the reduction of pressure rise rate.

Study on the Characteristics of Control by High Frequency ECU for Braking System (제동 시스템을 위한 고주파수 ECU의 제어 특성 연구)

  • Yeon, Kyu-Bong;Chong, Jong-Wha
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2428-2434
    • /
    • 2012
  • This paper describes the control of a solenoid valve of ESC(Electronic Stability Control) with hydraulic modulator in braking system. ESC ECU(Electronic Control Unit) to control the high-frequency control and slope control method was applied, the surge pressure and EMI(electromagnetic interference) reduction characteristics were studied. The stage of ECU output was added the slope shaping function to reduce electromagnetic emission at higher frequencies. Measurements show that this high frequency ECU manages to reduce the surge pressure and electromagnetic emission by the control of solenoid valve. In conclusion, by using the results of this study for the high frequency ECU control, we could expect enhancement of braking system performance.

The Reasonable SIL Determination by LOPA for HIPS Design of Flare Stack (LOPA분석에 의한 Flare Stack용 HIPS의 합리적 SIL결정)

  • Park, Jinhyung;Park, Kyoshik
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.221-221
    • /
    • 2023
  • 1969년에 발간된 API521 1st edition에서는 Flare Load 저감용으로 적용되는 HIPS (High Integrity Protection System)는 모두 Pressure Safety Valve의 고장확률보다 낮은 SIL 3 (Safety Integrity Level)등급을 적용할 것을 요구하고 있다. Flare Stack 저감용 HIPS는 주로 압축기 출력압력상승, Reboiler Steam 과다주입, 전력공급중단냉각펌프고장 등에 의한 Flare 발생을 예방하기 위한 기능을 가진 SIF (Safety Instrumented Function)로 구성된다. 하지만 2007년도 발간된 API521 5th edition에서는 LOPA (Layer Of Protection Analysis) 분석을 통해 Target SIL을 도출하는 것으로 요구사항을 변경했다. 이에 따라 이번 연구에서는 Flare Load에 가장 큰 영향을 미치는 시나리오 중 대표적인 시나리오를 대상으로 HAZOP(Hazard and Operability Study)과 LOPA분석을 실시해서 Target SIL이 어떻게 도출되는지를 연구했다. Flare Stack에서 Flare를 발생시키는 대표적인 시나리오들에 대해 LOPA분석을 실시한 결과 압축기 출력압력상승은 SIL 2, Reboiler Steam 과다주입은 SIL 3, 전력공급중단은 SIL 0, 냉각펌프고장은 SIL 0로 모두가 SIL 3 가 나오지는 않았다. SIF 설계 시 Target SIL을 만족시키는 것도 중요하지만 운전 시 SIL 등급이 계속 유지되게 하지 위해 인적오류, 시스템적 고장, 하드웨어고장 등에 의해 SIF 기능불능화가 되는 것을 예방하기 위한 기능안전관리시스템 (FSMS)를 적용하는 것도 중요하다.

  • PDF

A Study on Physicochemical Characteristics of Hydrogen Gas Explosion (수소가스 폭발의 물리화학적 특성 연구)

  • Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.1
    • /
    • pp.8-14
    • /
    • 2012
  • Hydrogen is considered to be the most important future energy carrier in many applications reducing significantly greenhouse gas emissions, but the explosion safety issues associated with hydrogen applications need to be investigated and fully understood to be applicable as the carrier. The risk associated with a explosion depends on an understanding of the impacts of the explosion, particularly the pressure-time history during the explosion. This work provides the effects of explosion parameters, such as specific heat ratio of burned and unburned gas, equilibrium maximum explosion pressure, and burning velocity, on the pressure-time history with flame growth model. The pressure-time history is dominantly depending on the burning velocity and equilibrium maximum explosion pressure of hydrogen-air mixture. The pressure rise rate increase with the burning velocity and equilibrium maximum explosion pressure. The specific heat ratio of unburned gas has more effect on the final explosion pressure increase rate than initial explosion pressure increase rate. However, the specific heat ratio of burned gas has more influence on initial explosion pressure increase rate. The flame speeds are obtained by fitting the experimental data sets. The flame speeds for hydrogen in air based on our experimental data is very low, making a transition from deflagration to detonation in a confined space unlikely under these conditions.

A study on the use of fire hydrants as a heat wave reduction facility through hydraulic analysis of water supply network (상수관망 수리해석을 통한 폭염 저감 시설로써의 소화전 활용방안연구)

  • Hong, Sung Jin;Choi, Doo Yong;Yoo, Do Guen
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.12
    • /
    • pp.1215-1222
    • /
    • 2021
  • In this study, a study on how to use a fire hydrant as a heat wave reduction facility through hydraulic analysis of the water supply pipe network was conducted. Assuming that the fire hydrant installation point is open for heat wave reduction, the water pressure at each point was derived. And the reduction rate of the temperature according to the hydrant watering was compared with the watering area according to the operation of the watering truck. The watering area according to the opening of the fire hydrant was calculated by deriving the pressure value at the node where the fire hydrant was installed through hydraulic analysis of the water pipe network, and then using the watering radius relational expression according to the pressure value. As a result of applying the proposed methodology to two real city areas, the temperature reduction effect of the watering method by a fire hydrant can be derived lower than the watering method by a watering truck according to the difference in the absolute watering area. However, unlike a watering truck, a fire hydrant does not have a relative restriction on the amount of water supply and is expected to allows continuous divided spraying of the same area.

A Study on Reduction Method of Stack Effect at Stairwell of High-Rise Building (고층건물 피난계단에서의 연돌효과 저감방안 연구)

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.14-20
    • /
    • 2011
  • As the height of the building increases, the stack effect in stairwell that is main facilities for evacuation becomes stronger. While the pressure rise in stairwell causes difficulties on opening the door for evacuation and has effect on smoke control system, reduction of stack effect will be necessary for providing more safe evacuation environment. The field experiments on pressure field in high-rise building are carried out to present reduction method of stack effect and the numerical analyses using network model are proceeded to design quantitatively the reduction method. As the air flow supplied from outside in lower stair and exhausted to outside in upper stair is formed in stairwell, the stack effect in stairwell is expected to be decreased.

크라이오 펌프 및 G-M 극저온 냉동기의 진동 저감을 위한 부품 설계 변경 및 해석에 따른 연구

  • Lee, Jae-Yong;Lee, Dong-Ju;Han, Myeong-Hui;Lee, Dae-Hui;Han, Min-Seop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.98.1-98.1
    • /
    • 2015
  • G-M극저온냉동기의 구동으로 인해 발생되는 크라이오 펌프의 진동 저감을 위해 각 요소에 해당하는 부품의 소재 및 모델 변경으로 설계에 반영하고자 한다. G-M극저온냉동기는 헬륨냉매를 사용하여 2개의 정압과정과 2개의 정적과정으로 구성되는 냉동사이클을 구성하는데, 구조적 특성상 내부 왕복기의 운동과 고저압변환에 따른 압력차이가 냉동기의 진동을 유발하므로 진공성능에 영향을 줄 수 있으므로, 이를 최소화하는 기술 개발이 필요하다. 헬륨냉매의 고압 유동에 따른 관로 압력증가로 인한 유동소음이 발생하는데, 이로 인한 소음을 줄이기 위해 관로의 최적화 설계/방진구조반영(DAMPER)으로 진동 안정화(Vibration Stabilization)설계를 수행 하고자 하며, 이에 따른 최적화 연구을 수행하고자 한다. 일차적으로, 기존 시스템의 진동측정을 통해 진동의 가진원을 밝히고 진동 전달경로를 파악하고자한다. 진동 가진원의 가진 최소화, 진동전달경로의 전달률 최소화, 고압유동에 따른 관로 설계 최적화를 진동해석, 탄성체 동역학해석, 그리고 유동해석을 통해 진동 및 소음의 최소화 방안을 도출하고자 한다. 해석결과를 토대로 진동가진원의 최소화를 위한 제품설계변경과 진동전달경로에 대한 방진을 위한 dmper 적용(전달률 최소화) 및 유동소음 최소화를 위한 damper나 관로 최적화 설계를 수행한다. 상기 기존시스템 측정/분석, CAE해석을 통한 진동/소음의 최적화방안도출 및 실제품 적용기술은 저진동 크라이오펌프 개발을 위한 기반 기술 확립에 크게 기여할것이며, 향후 크라이오펌프 고도화 및 최신 기술 제품 개발에 큰 기여가 기대된다.

  • PDF

The Performance Characteristics of Anti-Surge Devices for High Head Cooling Water Systems in 1,000 MW Thermal Power plants (고수두 1,000 MW 석탄화력발전소 냉각수계통 수격방지장치의 성능특성)

  • Kim, Keun-Pil;Yoo, Hoseon
    • Plant Journal
    • /
    • v.15 no.4
    • /
    • pp.36-42
    • /
    • 2019
  • In recent, according to the tightening of environment regulation policy, the height of the site of the power plant is increased and the length of the cooling water pipe is increased. This has a serious impact on the stability of the plant. This study analyzes the transient phenomenon using LIQT 7.2, an unsteady state one-dimensional analysis software, to secure the stability of 1,000 MW high-capacity coal-fired power plant cooling water system with high head. To prevent water hammer, The effects on performance characteristics were predicted by individual and combination application. The surge pressure of the cooling water which occurs when the pump was stopped without installing the anti-surge devices was the largest at the pump outlet side. The most effective and simple way to reduce surge pressure in these cooling water systems is to combine a vacuum breaker with a hydraulic non-return valve, which is an essential device for pump protection.

Applicability examinations of induced drainage system for reduction of uplift pressure in underpass structures: Numerical study (지하차도 부력저감을 위한 유도배수공법의 적용성 검토: 수치해석적 연구)

  • Jo, Seon-Ah;Jin, Gyu-Nam;Sim, Young-Jong;Cho, Gye-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.2
    • /
    • pp.123-134
    • /
    • 2013
  • Urban underground structures at low ground elevations (i.e. shallow substructures) unlike typical tunnel structures are subjected to low overburden and high water pressures. This often causes the underground structures to become damaged. Various conventional methods for the urban underpass structures such as dead weight increasement, round anchors, and tension piles, are significantly conservative and provok concerns about the costly, time-consuming installation process. Recently, permanent drainage system becomes to widely use for supplementing the conventional method's shortcomings, but, it is applied without the considerations for ground conditions and water table. In this study, therefore, numerical analyses are performed with various parameters such as groundwater level, wall height, and ground conditions in order to establish design guidelines for induced drainage system which is a kind of the permanent drainage method constructed at the Y-area. According to the numerical results, the induced drainage system is very effective in reducing the uplift pressure that acts on the base of underpass structures.

A Study on the Reduction of the Vibration in PKM Using a Propeller Damper (프로펠러 감쇄기를 이용한 고속정 진동 감소방안 연구)

  • Kim, Hye-Jin;Lee, Heun-Hwa;Seong, Woo-Jae;Pyo, Sang-Woo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.3
    • /
    • pp.103-110
    • /
    • 2008
  • Strategically, the Patrol Killer Medium (PKM) ought to run at high speed that produces largely vibration by propeller, in a consequence, the vibration gradually deterioratescrews' working condition and increases the possibility of SONAR detection. In this paper, we propose the propeller damper, which is one of waysto reduce the vibration induced by the propeller, and simulate the ability of the damper numerically. The propeller damper was designed to apply to an isolated plate at the bottom flat board of ship which is directly affected by the fluctuating pressure. The dynamic pressure for the stern part of the PKM is calculated by using the DnV rule and the numerical analysis when the propeller damper applied or not, is performed with ANSYS at the isolated plate that simplified. From the analysis, the damping effect of the proposed propeller damper is confirmed and the reduction ratio for each compartment is estimated based on the experimental data in the PKM.