• Title/Summary/Keyword: 압력손실도

Search Result 858, Processing Time 0.032 seconds

Development and Application of Siphon Breaker Simulation Program (사이펀 차단기 시뮬레이션 프로그램의 개발 및 활용)

  • Lee, Kwon-Yeong;Kim, Wan-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.346-353
    • /
    • 2016
  • In the design conditions of some research reactors, the siphon phenomenon can cause continuous efflux of water during pipe rupture. A siphon breaker is a safety device that can prevent water efflux effectively. However, the analysis of the siphon breaking is complicated because many variables must be included in the calculation process. For this reason, a simulation program was developed with a user-friendly GUI to analyze the siphon breaking easily. The program was developed by MFC programming using Visual Studio 2012 in Windows 8. After saving the input parameters from a user, the program proceeds with three steps of calculation using fluid mechanics formulas. Bernoulli's equation is used to calculate the velocity, quantity, water level, undershooting, pressure, loss coefficient, and factors related to the two-phase flow. The Chisholm model is used to predict the results from a real-scale experiment. The simulation results are shown in a graph, through which a user can examine the total breaking situation. It is also possible to save all of the resulting data. The program allows a user to easily confirm the status of the siphon breaking and would be helpful in the design of siphon breakers.

Numerical study on flow characteristics at dividing open-channel with changing bifurcation angle using TELEMAC-2D (TELEMAC-2D모형을 이용한 분류각 변화에 따른 개수로 흐름특성변화 수치모의 연구)

  • Jung, Daejin;Jang, Chang-Lae;Jung, Kwansue
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.8
    • /
    • pp.617-626
    • /
    • 2020
  • This study investigates changes of bifurcation discharge ratio, flow velocity distributions and characteristics of separation zone due to variation of bifurcation angle by using TELEMAC-2D model. When the bifurcation angle is reduced from 90° to 45° without changing the boundary conditions, the bifurcation discharge ratio increased by 1.5 times from 0.523 to 0.785 because of increasing the radius of curvatures, the inertia force of the downstream flow, and the pressure gradient by the downstream boundary conditions. The bifurcation discharge ratio increases non-linearly whenever the bifurcation angle decreases by 15° intervals from 90° to 45° in flow with the upstream Froude number of 0.45 to 0.74. In flow with a maximum Froude number of 0.74, the rate of increase for bifurcation discharge ratio is 31.1% and the minimum value. When the Froude number is 0.58, the bifurcation discharge ratio is 0.7 or less, and the maximum rate of increase for that ratio is 53.5%. As the upstream Froude number decreases less than 0.58, the bifurcation discharge ratio exceeds 0.7, and the rate of increase decreases. When the upstream Froude number is 0.4 higher, the dimensionless width and length changing ratio of the separation zone are about 2.56 and 5.5 times higher than in 0.4 or less.

Thickness Determination of Ultrathin Gate Oxide Grown by Wet Oxidation

  • 장효식;황현상;이확주;조현모;김현경;문대원
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.107-107
    • /
    • 2000
  • 최근 반도체 소자의 고집적화 및 대용량화의 경향에 다라 MOSFET 소자 제작에 이동되는 게이트 산화막의 두께가 수 nm 정도까지 점점 얇아지는 추세이고 Giga-DRAM급 차세대 UNSI소자를 제작하기 위해 5nm이하의 게이트 절연막이 요구된다. 이런 절연막의 두께감소는 게이트 정전용량을 증가시켜 트랜지스터의 속도를 빠르게 하며, 동시에 저전압동작을 가능하게 하기 때문에 게이트 산화막의 두께는 MOS공정세대가 진행되어감에 따라 계속 감소할 것이다. 따라서 절연막 두께는 소자의 동작 특성을 결정하는 중요한 요소이므로 이에 대한 정확한 평가 방법의 확보는 공정 control 측면에서 필수적이다. 그러나, 절연막의 두께가 작아지면서 게이트 산화막과 crystalline siliconrksm이 계면효과가 박막의 두께에 심각한 영향을 주기 때문에 정확한 두께 계측이 어렵고 계측방법에 따라서 두께 계측의 차이가 난다. 따라서 차세대 반도체 소자의 개발 및 양산 체계를 확립하기 위해서는 산화막의 두께가 10nm보다 작은 1nm-5nm 수준의 박막 시료에 대한 두께 계측 방법이 확립이 되어야 한다. 따라서, 본 연구에서는 습식 산화 공정으로 제작된 3nm-7nm 의 게이트 절연막을 현재까지 알려진 다양한 두께 평가방법을 비교 연구하였다. 절연막을 MEIS (Medim Energy Ion Scattering), 0.015nm의 고감도를 가지는 SE (Spectroscopic Ellipsometry), XPS, 고분해능 전자현미경 (TEM)을 이용하여 측정 비교하였다. 또한 polysilicon gate를 가지는 MOS capacitor를 제작하여 소자의 Capacitance-Voltage 및 Current-Voltage를 측정하여 절연막 두께를 계산하여 가장 좋은 두께 계측 방법을 찾고자 한다.다. 마이크로스트립 링 공진기는 링의 원주길이가 전자기파 파장길이의 정수배가 되면 공진이 일어나는 구조이다. Fused quartz를 기판으로 하여 증착압력을 변수로 하여 TiO2 박막을 증착하였다. 그리고 그 위에 은 (silver)을 사용하여 링 패턴을 형성하였다. 이와 같이 공진기를 제작하여 network analyzer (HP 8510C)로 마이크로파 대역에서의 공진특서을 측정하였다. 공진특성으로부터 전체 품질계수와 유효유전율, 그리고 TiO2 박막의 품질계수를 얻어내었다. 측정결과 rutile에서 anatase로 박막의 상이 변할수록 유전율은 감소하고 유전손실은 증가하는 결과를 나타내었다.의 성장률이 둔화됨을 볼 수 있다. 또한 Silane 가스량이 적어지는 영역에서는 가스량의 감소에 의해 성장속도가 둔화됨을 볼 수 있다. 또한 Silane 가스량이 적어지는 영역에서는 가스량의 감소에 의해 성장속도가 줄어들어 성장률이 Silane가스량에 의해 지배됨을 볼 수 있다. UV-VIS spectrophotometer에 의한 비정질 SiC 박막의 투과도와 파장과의 관계에 있어 유리를 기판으로 사용했으므로 유리의투과도를 감안했으며, 유리에 대한 상대적인 비율 관계로 투과도를 나타냈었다. 또한 비저질 SiC 박막의 흡수계수는 Ellipsometry에 의해 측정된 Δ과 Ψ값을 이용하여 시뮬레이션한 결과로 비정질 SiC 박막의 두께를 이용하여 구하였다. 또한 Tauc Plot을 통해 박막의 optical band gap을 2.6~3.7eV로 조절할 수 있었다. 20$0^{\circ}C$이상으로 증가시켜도 광투과율은 큰 변화를 나타내지 않았다.부터 전분-지질복합제의 형성 촉진이 시사되었다.이것으로 인하여 호화억제에 의한 노화 방지효과가 기대되었지만 실제로 빵의 노화는 현저히 진행되었다

  • PDF

Wide Bandgap 박막 태양전지 제작을 위한 P-type a-$SiO_x$:H layer 최적화에 관한 연구

  • Yun, Gi-Chan;Kim, Yeong-Guk;Park, Seung-Man;Park, Jin-Ju;Lee, Seon-Hwa;An, Si-Hyeon;Lee, Jun-Sin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.153-153
    • /
    • 2010
  • p-i-n 형 비정질 실리콘 박막 태양전지에서 p층은 창물질(window material)로서 전기 전도도가 크고, 빛 흡수가 적어야한다. p층의 두께가 얇으면 p층 전체가 depletion layer가 되고 충분한 diffusion potential을 얻을 수 없어 open-circuit voltage ($V_{oc}$)가 작아진다. 반대로 p층 두께가 두꺼워지면 빛 흡수가 증가하고, 표면 재결합이 문제가 되어 변환효율이 감소한다. 밴드갭이 큰 물질로 창층을 제작하게 되면 보다 짧은 파장의 입사광이 직접 i층을 비추므로 Short-circuit current ($I_{sc}$) 와 fill factor를 증가시킬 수 있다. 하여 본 연구에서는 기존의 창층으로 사용되는 Boron을 doping한 p-type a-Si:H 대신에 $N_2O$를 첨가한 p-type a-$SiO_x$:H의 $N_2O$ flow rate에 따른 밴드갭의 변화에 관한 연구를 수행하였다. p-type a-$SiO_x$:H Layer는 $SiH_4$, $H_2$, $N_2O$, $B_2H_6$ 가스를 혼합하여 증착하게 되는데 $SiH_4$, 가스와 $H_2$ 가스의 혼합비는 1:20, $B_2H_6$ 농도는 0.5%로 고정 하였으며 $N_2O$의 flow rate을 가변하며 증착하였다. $N_2O$의 가변조건은 5에서 50sccm으로 가변하여 증착하며 일반적으로 사용되는 RF-PECVD (13.56MHz)를 이용하였고 증착 온도는 175도, 전극간의 거리는 40mm, 파워와 압력은 30W, 700mTorr로 고정하여 진행하였다. 전기적 특성을 알아보기 위해 eagle 2000 Glass를 사용하였고 구조적 특성은 p-type wafer를 사용하여 각각 대략 200nm의 두께로 증착하였다. 증착 두께는 Ellipsometry를 이용하였으며 전기 전도도는 Agilent사의 4156c를 구조적특성은 FT-IR을 사용하여 측정하였다. Conductivity(${\sigma}_d$)는 $N_2O$가 증가함에 따라 $8.73\;{\times}\;10^{-6}$에서 $5.06\;{\times}\;10^{-7}$으로 감소하였고 optical bandgap ($E_{opt}$)은 1.71eV에서 2.0eV로 증가함을 알 수 있었다. 또한 reflective index(n)의 경우는 4.32에서 3.52로 감소함을 나타내었다. 기존의 p-type a-Si:H에 비해 상당한 $E_{opt}$을 가지므로 빛 흡수에 의한 손실을 줄임으로서 $V_oc$를 향상 시킬 수 있으며 동시에 짧은 파장에서의 입사광이 직접 i층을 비추므로 $I_{sc}$와 FF를 향상 시킬 수 있으리라 예상된다. 다소 낮은 전도도만 개선한다면 고효율의 박막 태양전지를 제작 할 수 있을 것으로 기대된다.

  • PDF

An Experimental Study for the Effect of Operating Condition of the Air Handling Unit on the Performance of Humidifying Elements (공조기 운전 조건이 가습 소자의 성능에 미치는 영향에 대한 실험 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.326-331
    • /
    • 2018
  • Evaporative humidification using a humidifying element is used widely for the humidification of a building or a data center. The performance of a humidifying element is commonly expressed as the humidification efficiency, which is assumed to be independent of the air temperature or humidity. To verify this assumption, a series of tests were conducted under two air conditions - data center ($25^{\circ}C$ DBT, $15^{\circ}C$ WBT) and commercial building ($35^{\circ}C$ DBT, $21^{\circ}C$ WBT) - using humidifying elements made from cellulose/PET and changing the frontal air velocity from 1.0 m/s to 4.5 m/s. Three samples having a 100 mm, 200 mm, or 300 mm depth were tested. The results showed that the humidification efficiency is dependent on the air condition. Indeed, even dehumidification occurred at the inlet of the humidifying element at the air condition of commercial building. This suggests that a proper thermal model should account for the inlet area, where the amount of moisture transfer may be different from the other part of the humidification element. As the depth of the element increased from 100 mm to 200 mm, the humidification efficiency increased by 29%. With further increases to 300 mm, it increased by 42%. On the other hand, the pressure drop also increased by 47% and 86%.

Characteristics of Large-area PTFE Filter Coated with PTFE Nanofiber Fabricated by Roll-to-roll Equipment (Roll-to-roll 공정으로 제조한 나노섬유가 코팅된 대면적 PTFE 필터 특성)

  • Ahn, Seunghwan;Lee, Woo Jin;Kim, Yeonsang;Shim, Euijin;Eom, Hyeonjin
    • Applied Chemistry for Engineering
    • /
    • v.33 no.6
    • /
    • pp.613-617
    • /
    • 2022
  • The equipment for fabricating the large-area PTFE nanofiber coated-PTFE foam filter for use as filtration parts of the baghouse that removes particulate matter (PM) in industrial sites was designed and manufactured in this study. The PTFE nanofiber was coated on a commercial PTFE foam filter to increase its PM collection efficiency. The equipment and fabrication processes using a roll-to-roll system were proposed to continuously coat PTFE nanofibers on the surface of the PTFE foam filter. The electrospinning and annealing parts were designed and made by optimizing the equipment for the roll-to-roll system. The surface morphology, composition, and filtration characteristics of the large-area filter fabricated by this equipment were confirmed. PTFE nanofibers were uniformly coated on the large-area filter, and the PTFE nanofiber coated-PTFE foam filter showed PM2.5 collection efficiency of 91.79% and an appropriate pressure drop of 62 Pa with a face velocity of 1 m/min at 280 ℃.

Evaluation of Water Quality Change by Membrane Damage to Pretreatment Process on SDI in Wastewater Reuse (하수재이용에서 전처리 막 손상에 의한 수질변화가 SDI에 미치는 영향평가)

  • Lee, Min Soo;Seo, Dongjoo;Lee, Yong-Soo;Chung, Kun Yong
    • Membrane Journal
    • /
    • v.32 no.4
    • /
    • pp.253-263
    • /
    • 2022
  • This study suggests a guideline for designing unit process of wastewater reuse in terms of a maintenance of the process based on critical parameters to draw a high quality performance of RO unit. Defining the parameters was done by applying membrane integrity test (MIT) in pretreatment process utilizing lab-scale MF. SDI is utilized for judging whether permeate is suitable to RO unit. However, result said TOC concentration matching with particle count analysis is better for judging the permeate condition. When membrane test pressure (Ptest) was measured to derive log removal value in PDT, virgin state of membrane fiber was used to measure dynamic contact angle utilizing surface tension of the membrane fiber. Actually, foulant affects to the state of membrane surface, and it decreases the Ptest value along with time elapsed. Consequently, LRVDIT is also affected by Ptest value. Thus, sensitivity of direct integrity test descends with result of Ptest value change, so Ptest value should be considered not the virgin state of the membrane but its current state. Overall, this study focuses on defining design parameters suitable to MF pretreatment for RO process in wastewater reuse by assessing its impact. Therefore, utilities can acknowledge that the membrane surface condition must be considered when users conduct the direct integrity test so that Ptest and other relative parameter used to calculate LRVDIT are adequately measured.

Study on the Application of Casting Flow Simulation with Cut Cell Method by the Casting process (Cut Cell 방법을 활용한 공정별 주조유동해석 적용 연구)

  • Young-Sim Choi
    • Journal of Korea Foundry Society
    • /
    • v.43 no.6
    • /
    • pp.302-309
    • /
    • 2023
  • In general, castings often have complex shapes and significant variations in thickness within a single product, making grid generation for simulations challenging. Casting flows involve multiphase flows, requiring the tracking of the boundary between air and molten metal. Additionally, considerable time is spent calculating pressure fields due to density differences in a numerical analysis. For these reasons, the Cartesian grid system has traditionally been used in mold filling simulations. However, orthogonal grids fail to represent shapes accurately, leading to a momentum loss caused by the stair-like grid patterns on curved and sloped surfaces. This can alter the flow of molten metals and result in incorrect casting process designs. To address this issue, simulations in the Cartesian grid system involve creating a large number of grids to represent shapes more accurately. Alternatively, the Cut Cell method can be applied to address the problems arising from the Cartesian grid system. In this study, analysis results based on the number of grid in the Cartesian grid system for a casting flow analysis were compared with results obtained using the Cut Cell method. Casting flow simulations of actual products during various casting processes were also conducted, and these results were analyzed with and without applying the Cut Cell method.

Comparison of the Uniaxial Tensile Strength, Elasticity and Thermal Stability between Glutaraldehyde and Glutaraldehyde with Solvent Fixation in Xenograft Cardiovascular Tissue (이종심혈관 조직에 대한 글루타알데하이드 및 용매를 첨가한 고정방법에 따른 장력, 탄력도 및 열성 안정성 비교연구)

  • Cho, Sung-Kyu;Kim, Yong-Jin;Kim, Soo-Hwan;Park, Ji-Eun;Kim, Wong-Han
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.165-174
    • /
    • 2009
  • Background: With the advances of cardiac surgery, the demand for an artificial prosthesis has increased, and this has led to the development and utilization of diverse alternative materials. We conducted this research to improve an artificial prosthesis by examining the changes of the physical qualities, the pressure related tensile strength, the change in elasticity and the thermostability of a xenograft valve (porcine) and pericardium (bovine, porcine) based on the type of fixation liquid we used. Material and Method: The xenograft valves and pericardium were assigned into three groups: the untreated group, the fixed with glutaraldehyde (GA) group and the glutaraldehyde with GA+solvent such as ethanol etc. group. The surgeons carried out each group's physical activities. Each group's uniaxial tension and elasticity was measured and compared. Thermostability testing was conducted and compared between the bovine and porcine pericardium fixed with GA group and the GA+solvent group. Result: On the physical activity test in the surgeon's hand, no significant difference between the groups was sensed on palpation. For suture and tension, the GA+solvent group was slightly firmer than the low GA concentration group. In general, the circumferential uniaxial tension and elasticity of the porcine aortic and pulmonary valves were better in the fixed groups than that in the untreated group. There was no significant difference between the GA and GA+solvent groups (p>0.05). Bovine and porcine pericardium also showed no significant difference between the GA group and the GA+solvent group (p>0.05). When comparing between the groups for each experiment, the elasticity tended to be stronger in most of the higher GA concentration group (porcine pulmonary valve, porcine pericardium). On the thermostability testing of the bovine and porcine pericardium, the GA group and the G+solvent group both had a sudden shrinking point at $80^{\circ}C$ that showed no difference (bovine pericardium: p=0.057, porcine pericardium: p=0.227). Conclusion: When fixing xenograft prosthetic devices with GA, adding a solvent did not cause a loss in pressure-tension, tension-elasticity and thermostability. In addition, more functional solvents or cleansers should be developed for developing better xenografts.

Evaluation of Dark Spots Formated on the High Temperature Metal Filter Elements (고온 금속필터 element 표면에 생성된 반점에 대한 평가)

  • Park, Seung-Chul;Hwang, Tae-Won;Moon, Chan-Kook
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.3
    • /
    • pp.171-178
    • /
    • 2008
  • Metal filter elements were newly introduced to the high temperature filter(HTF) system in the low- and intermediate-level radioactive waste vitrification plant. In order to evaluate the performance of various metal materials as filter media, elements made of AISI 316L, AISI 904L, and Inconel 600 were included to the test set of filter elements. At the visual inspection to the elements performed after completion of each test, a few dark spots were observed on the surface of some elements. Especially they were found much more at the AISI 316L elements than others. To check the dark spots are the corrosion phenomena or not, two kinds of analyses were performed to the tested filter elements. Firstly, the surfaces or the cross sections of filter specimens cut out from both normal area and dark spot area of elements were analyzed by SEM/EDS. The results showed that the dark spots were not evidences of corrosion but the deposition of sodium, sulfur and silica compounds volatilized from waste or molten glass. Secondly, the ring tensile strength were analyzed for the ring-shape filter specimens cut out from each kind of element. The result obtained from the strength tested showed no evidence of corrosion as well. Conclusionally, depending on the two kinds of analysis, no evidences of corrosion were found at the tested metal filter elements. But the dark spots formed on the surface could reduce the effective filtering area and increase the overall pressure drop of HTF system. Thus, continuous heating inside filter housing up to dew point will be required normally. And a few long-period test should be followed for the exact evaluation of corrosion of the metal filter elements.

  • PDF