• Title/Summary/Keyword: 암모니아 흡수기

Search Result 54, Processing Time 0.028 seconds

Operating Characteristics of Ammonia-Water Absorber Heat Exchange Cycle (암모니아-물 흡수식 열교환 사이클의 운전 특성)

  • 강인석;김남진;김종보
    • Journal of Energy Engineering
    • /
    • v.10 no.4
    • /
    • pp.357-362
    • /
    • 2001
  • A bench type ammonia-water absorber heat exchange cycle was tested by varying the system charging concentration, refrigerating valve opening and weak solution flow rate. It was observed that the cooling capacity was increased as the system charging concentration was increased. Optimum system charging concentration was found for the coolong capacity of the system. The opening rate of refrigerant expansion valve had a direct influence on the refrigerant sub-cooling at the condenser outlet. Optimum sub-cooling was found to be 0~4$^{\circ}C$. As the weak solution flow rate increased the concentration of strong solution and the evaporating pressure decreased. There existed a optimum weak solution flow rate which maximized the cooling capacity and COP.

  • PDF

Reaction Characteristics of Simultaneous Removal of $SO_{x}/NO_{x}$ from flue gas with $CuO/{\gamma}-Al_2O_3$ sorbent/catalyst (산화구리가 담지된 알루미나 흡수제/촉매를 이용한 배연 탈황/탈질 동시제거 반응특성)

  • 유경선;김상돈
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1994.11a
    • /
    • pp.97-100
    • /
    • 1994
  • 산화구리가 담지된 알루미나 흡수제/촉매를 이용하여 유황산화물과 질소산화물의 제거반응 특성을 고정층 반응기를 이용하여 고찰하였다. 반응온도가 증가할 수록 $350^{\circ}C$까지 탈질 효율이 증가하였으며 그 이상의 온도에서는 암모니아의 산화에 의하여 탈질효율이 감소하였다. 암모니아의 $NO_{x}$ 선택성은 $SO_{x}$ 가 존재하지 않는 경우에 $NH_3/NO_{x}$mole 비 1.0 까지 유지되었으나 $SO_{x}$ 가 존재하면 선택성은 매우 감소하였다. 동시제거 반응의 경우 $400^{\circ}C$ 이상에서 효과적이었으며 $350^{\circ}C$ 이하에서는 암모늄 염의 생성으로 인하여 탈질효율의 감소가 반응시간이 증가함에 따라서 감소하였다.

  • PDF

The Characteristics of Heating Performance on Small Sized Ammonia Absorption System (소형 암모니아 흡수식 냉난방기의 난방성능 특성)

  • Jin, Byoung-Ju;Oh, Seung-Taek;Yoon, Jung-In;Hwang, Jun-Hyeon;Jin, Sim-Won
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.120-123
    • /
    • 2008
  • Refrigeration plants using absorption principles have been around for many years with initial development taking place over 100 years ago. Although the majority of absorption cycles are based on water-LiBr cycle, many applications exist where ammonia-water can be used, especially where lower temperatures are desirable. In both systems water is used as working fluid, but in quite different ways: as a solvent for the ammonia system, and as refrigerant for the lithium bromide system. This explains that the lithium bromide absorption system is strictly limited to evaporation temperatures above $0^{\circ}C$. The main industrial applications for refrigeration are in the temperature range below $0^{\circ}C$, the field for the binary system ammonia-water.

  • PDF

The Characteristics of Heating Performance on Small Sized Ammonia Absorption System (소형 암모니아 흡수식 냉난방기의 냉방성능 특성)

  • Jin, Byoung-Ju;Oh, Seung-Taek;Yoon, Jung-In;Hwang, Jun-Hyeon;Jin, Sim-Won;Kyung, Ick-Soo;Erickson, Donald C
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.198-202
    • /
    • 2008
  • Refrigeration plants using absorption principles have been around for many years with initial development taking place over 100 years ago. Although the majority of absorption cycles are based on water-LiBr cycle, many applications exist where ammonia-water can be used, especially where lower temperatures are desirable. In both systems water is used as working fluid, but in quite different ways: as a solvent for the ammonia system, and as refrigerant for the lithium bromide system. This explains that the lithium bromide absorption system is strictly limited to evaporation temperatures above $0^{\circ}C$. The main industrial applications for refrigeration are in the temperature range below $0^{\circ}C$, the field for the binary system ammonia-water.

  • PDF

Evaluation of Dispersion Stability and Absorption Performance Enhancement of Binary Nanoemulsion Fluids (이성분 나노에멀전 유체의 분산안정성 및 흡수성능 촉진실험)

  • Lee, Jin-Ki;Kim, Young-Jin;Shin, Myung-Chul;Kim, Se-Won;Kang, Yong-Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.9
    • /
    • pp.895-900
    • /
    • 2012
  • This paper aims to examine the effect of nanodroplets on pool-type absorption heat transfer enhancement and to find the relationship between the dispersion stability and the absorption performance. The concentrations of oil and surfactant are considered as the key parameters. $C_{12}E_4$ and Tween20 are used as the surfactants and N-decane oil is added to the $NH_3/H_2O$ solution to make the binary nanoemulsion fluids. Binary nanoemulsion fluids are dispersed by the ultrasonic vibrator and the stirrer under specific conditions. The dispersion stability of binary nanoemulsion fluids for each oil concentrations is evaluated from the droplet size and Tyndall effect analysis. The absorption performance of binary nanoemulsion fluids is compared with the result of dispersion stability. In addition, it is found that the binary nanoemulsion fluid is a strong candidate as a new working fluid for absorption applications.

A Thermodynamic Study on Suction Cooling-Steam Injected Gas Turbine Cycle (吸氣冷却-蒸氣噴射 가스터빈 사이클에 관한 열역학적 연구)

  • 박종구;양옥룡
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.77-86
    • /
    • 1992
  • This paper discusses the thermodynamic study on the suction cooling-steam injected gas turbine cycle. The aim of this study is to improve the thermal efficiency and the specific output by steam injection produced by the waste heat from the waste heat recovery boiler and by cooling compressor inlet air by an ammonia absorption-type suction cooling system. The operating region of this newly devised cycle depends upon the pinch point limit and the outlet temperature of refrigerator. The higher steam injection ratio and the lower the evaporating temperature of refrigerant allow the higher thermal efficiency and the specific output. The optimum pressure ratios and the steam injection ratios for the maximum thermal efficiency and the specific output can be found. It is evident that this cycle considered as one of the most effective methods which can obtain the higher thermal efficiency and the specific output comparing with the conventional simple cycle and steam injected gas turbine cycle.

Electromagnetic Interference Shielding Efficiency Characteristics of Ammonia-treated Graphene Oxide (암모니아수 처리된 그래핀 옥사이드의 전자파 차폐효율 특성)

  • Park, Mi-Seon;Yun, Kug Jin;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.25 no.6
    • /
    • pp.613-618
    • /
    • 2014
  • In this study, nitrogen doped graphene oxide (GO) was prepared using liquid phase ammonia treatment to improve its electrical properties. Also, the aminated GO was manufactured into a film format and the electromagnetic interference (EMI) shielding efficiency was measured to evaluate its electrical properties. The XPS result showed that the increase of liquid phase ammonia treatment concentration led to the increased nitrogen functional group on the GO surface. The measurement of EMI shielding efficiency reveals that EMI shielding efficiency of the liquid phase ammonia treated GO was better than that of non-treated GO. When GO was treated using the ammonia solution of 21% concentration, the EMI shielding efficiency increased by -5 dB at higher than 2950 MHz. These results were maybe due to the fact that nitrogen functional groups on GO help to improve the absorbance of electromagnetic waves via facile electron transfer.

Rectification Characteristic of Packing Materials in the Packed-type Rectifier of $NH_3/H_2O$ Absorption Heat Pump (암모니아 흡수식 열펌프 충전식 정류기의 정류 특성에 관한 연구)

  • 김돈수;윤상국
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.10
    • /
    • pp.775-780
    • /
    • 2002
  • An experimental study on the characteristics of several kinds of packing materials was carried out in order to get the optimum design data for the packed-type rectification system of an NH$_3$/$H_2O$ GAX absorption heat pump. Several suitable packing materials were examined and the bulk of steel wire was shown as the most effective packing material in rectifier. The optimum volumetric ratio of packed steel wire in rectifier was obtained as around 36%. The performance results can be adapted in rectifier design of absorption heat pump.

Next generation absorption technologies in USA and Japan(2) - Next generations technologies in Japan - (미국 및 일본의 차세대 홉수식 열펌프 기술(2) - 일본의 차세대 흡수식 연구동향 -)

  • 강용태
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.28 no.4
    • /
    • pp.300-314
    • /
    • 1999
  • 가스구동 흡수식 시스템은 인류와 환경에 여러 가지 유익을 가져다준다. 첫째, 시스템의 고효율에 따른 매력적인 경제성을 제공하고, 둘째 천연가스의 사용으로 인하여 여름철 피크 전력소요(peak electric demand)를 완화하고, 셋째 이산화탄소 ($CO_2$)의 발생을 감소시킴으로써 지구 온난화 현상을 완화한다 실제로 가스구동 흡수식 시스템으로부터의 $CO_2$발생량은 증기보일러를 사용하는 전기구동 냉동기에 비하여 85% 수준인 것으로 보고되었다(Suzuki 등). 넷째로 암모니아 및 물과 같은 환경 친화적인 냉매들을 사용함으로서 오존층을 파괴하는 Chlorofluorocarbon(CFC) 및 Hydrochlorofluorocarbon(FCFC)계 냉매들을 대체할 수 있는 이점이 있다.

  • PDF